Loading...
HomeMy WebLinkAboutRevisions OFFICE USE ONLY: DATE FILED: PERMIT# REVISION FEE: RECEIPT# PLANNING& DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE,FL 34982-5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 2 aaS S34k 51- DETAILED DESCRIPTION OF PROJECT REVISIONS: I Addin k�e Covou(AA yaoJ I "J i CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #: BUSINESS NAME: r QUALIFIERS NAME: ADDRESS: �1 S of 1 1�, uu S - CITYJ G� STATE: �=�o� d� ZIP: 3y 5 PHONE(DAYTIME): 7�� -3� o g y, 6 FAX: OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE(DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE(DAYTIME): FAX: �`�'`4� ►�� ae SLCCC: 9123109 Revised 06/30/17 REVISION i Rusmess ' f e a e BCIS.Home 1 Log In f Use Registration ; Hot Topic � Submit Surcharge � Stats&Facts Publications Contact Us ,•BCIS Site Map' Unks Search- Pro. �. f duct Approval j' poritl } i i• us E .Public User v47!S'rSry" Lr�•.:::eirl:a Product Anaroval Menu>Product or Application search>Application List>Application betail p FL# FL20484-R1 !' ^� Application Type. Revision �• Code Version 2017 Application Status Approved — Comments 6 5 f� / t ' Archived 0 REVIEWED FOR Product Manufacturer UNION CORRUGA 6JJVAddress/Phone/Email COMPLIANCE701S . FAYETT(910 483Io 79Nc ERM. L.UCIE COUNTY jstieby@unioncormgating.corb Authorized Signature John S@unl ' jstieby@unioneorruga t BOCC`4ffting.com \//y I Technical Representative Address/Phone/Email i l! Quality Assurance Representative Address/Phone/Email Category' Roofing File Co Subcategory Metal Roofing i Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received f i , Florida Engineer.or Architect Name who developed Bala Sockaiingam the Evaluatior Report r Florida License PE-62240 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 09/07/2027; Validated By Yoosef Levi,;P.E. 21 Validation Checklist-Hardcopy Received 4 Certificate of Independence FL20484 R3 COI Certificatelndeoend nce odf I Referenced Standard and Year(of Standard) Standard Year FM 4470 2012 TAS 125 2003 UL 1897 2012 UL 580 2006 i Equivalence of Product Standards j Certified By Sections from the Code https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgX... 10/12/2019 Florida Binldmg Uode UnIme 1 Product Approval Method Method i Opdon D I Date Submitted 08/23/2017 Date Validated 08/28/2017' Date Pending FBC Approval 09/01/2017 Date Approved 12/12/2017 ' I r Sumrnary of Products FL# Model,Number or Name Description 20484.1 5V Min 26 ga.,24"wide through fastened panel over 15/32" thl`ck plywood Limits-of'Use Installation Instructions Approved for use in HVHZ:No FL20484 R1 II EvaluationReportC2175 i odF Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam,P.E.62240 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-169 Evaluation Reports Other:Uplift load of 71.0 psi @ fastener spacing of 24"o.c, FL20484 R1 AE EyaluationReportC2175 1 odf ' &169.0 psf @ fastener spacing of 6"o.c. Created by Independent Third Party:Yes {k 20484.2 Advantage-Lok II Min 26 ga. 16"wide concealed fastened panel over 7/16" I thick OSB&15/32"&thick plywood Limits of:Use Installation Instructions Approved for use in HVHZ:No FL20484'RI II EvaluationReoortC2175 2 odf Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam P.E.62240 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-116 Evaluation Reports Other:Maximum uplift load of I16.0 psf @ seam fastener FL20484 R1 AE EvaluationReoortC2175 2 odf spacing of 4-5/8"o.c.along seam Into min. 15/32"thick APA Created by Independent Third Party:Yes rated plywood with retainer strap. 20484.3 Aluminum Advantage-Lok II Max 16.375"wide,nom 0.032"thick(min.)aluminum 1 concealed fastener roof panel over min 15/32"thick plywood deck or 7/16"thick 0S8. " Limits of Use Installation Instructions Approved for use in HVHZ:No h20484 RI II Evalua6onReoortC2175 3 odf Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam P.E.62240 Impact Resistant:N/A Created by,Independent Third Party:Yes Design Pressure:+N/A/-93.5_ Evaluation Reports Other:Uplift load of 22.5 psf at fastener spacing of 18,5" F1_20484 R1 AE EvaluationReoort 2175 3 ndf ox..and 86.0 psf at fastener spacing of 4.63"o.c.in 15/32" Created by Independent Third Party:Yes plywood or 7/16"OSS.Uplift load of 93.5 psf at fastener spacing of4.63"o.c.with structural sealant in 15/32" plywood. 20484.4 Aluminum SL150 Max 16"wide,nom 0.032'.'thick'(min.)aluminum snap-lock standing seam metal panel over min 15/32"thick plywood_ deck or 7/16"thick OSB. Limits of use Installation Instructions j Approved for use in HVHZ:No F1,20484 RI II EvaluationReoortC2175 4 pdf Approved forXe outside HVHZ:yes Verified By:Bala Sockalingam P.E.62240' Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-86 Evaluation Reports Other:,-Uplift load of 45.0 psf at clip spacing of 24"o.c..and h20484 R1 AE EvaluationReoortC2175 4 odf 78.5 psf at clip spacing of 6"o.c.in 15/32"plywood or 7/16" Created by Independent Third Party:-Yes i OSB.Uplift load of 86.0 psf at clip spacing of 6"o.c.with structural sealant in 15/32"plywood. 20484.5 MasterRib Min 29 ga'.,36"wide through fastened panel over 15/32" thick plywood or 7/16"thick OSB Limits of Use Installation instructions Approved for use-in HVHZ:No FL20484 R1 II EvatuationReoortC2175 5 odf I Approved for useutside HVHZ:Yes Verified By:Bala Sockalingam,P.E.62240 Impact Resistant:outside Created by Independent Third Party:Yes Design Pressure:+N/A/-124 [evaluation Reports Other:Uplift load of 56.0 psf @ fastener spacing of 24"-o.c. F00484 RI AE EvaluationRePortC2175 5 adF &124.0 psf @ fastener spacing of,6"o.c. Created-by Independent Third Party:Yes 20484.'6 MasterRib Min 29 ga.,36"wide.through fastened panel over 15/32" thick-plywood Limits of Use Installation Instructions r Approved.fo use in HVHZ:No FL20484 R1 II Eva luatlonReoortC2175 6 odf Approved for use outside.HVHZ:Yes Verified By:Bala Sockalingam,P.E.62240 Impact Resistant:N/A ;Created by Independent Third Party:Yes Design Pressure:+N/A/=88:5 Evaluation Reports Other:Uplift load of 56 psf for Fastening System 1.Uplift 'FL26484 R1 .AE EyaluatlonReoortC2175 b odf load of BB.5 psf for Fastening System 2_ Created by Independent Third Party:Yes i h s;//www.floridabuild n .or r/ i a dtl.as x? aram=wGEVX wtD sJ9a49YA nP g �P P PP.. P P Q q gX... 10/12/2019 I I ! Florida"Building Code Online Page 3 of 3 i 20484.7 ML150 Max 16.5"wide,min 24 ga.steel standing seam panel over 15/.32"thick plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL20484 RI II EvaluationRe0ortC2175 7 odf j Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam,P.E.62240 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-124 Evaluation Reports Other:Maximum uplift load of 124 psF @ clip spacing of 6" FL20484 R1 AE EvaluationReoortC2175 7 odf t i o.c.with 180 seam,self-adhering membrane and fixed clip. Created by Independent Third.Party:Yes l 20484.8 PBR or R Panel Min 26 ga.,36"wide through fastened panel over 15/32' I thick plywood Limits of Use. Instaliation.Instructions Approved for use in HVHZ:No F1'20484 R1 II'EvaluationReportC2175 8 odf Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam P:E.62240 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/461.5 Evaluation Reports Other:Uplift load.of 30.0 psf at fastener spacing of 48"o.c. FLZ0484 R1 AE EvaluationReoortC2175 8 odf and 161.5'psfat fastener spacing of 6"o.c. Created by,Independent Third Party:Yes 20484.9 SL175 Max 18"wide,min 24 ga.,snap-lock standing seam metal panel over,15/32"thick plywood Limits of Use Installation Instructions Approved for-use in HVHZ:No Fb13484 R3 II EvaluatiOnReportC2175 9.odf Approved for use outside HVHZ:Yes, Verified By:Bala Sockalingam,P.E.62240 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-93.5 Etialuation Reports Other:Uplift load of 39.8 psf @ clip spacing of 36"o.c.and FL20484 R1 AE EvatuationReoortC2175 9 odf 78.6 psf @ clip spacing of 8"o.c with felt.Uplift load of 93.5 Cleated by Independent Third Party.:Yes psf @ clip�spacing of 12"o.c.with self-adhering membrane. I , I 8adc Nrext Contact Us 2601 Blair Stone Road.Tallahassee FL 32399 Phone;850,487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-013 SO of Florida -:Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail'address released in response to a public-records request,do not send electronic mail to this'entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida statutes,effective October 1,2012,licensees licensed under Chapter 455,'F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the,Oepattment with an ematfaddress which can be made available to the public.To determine If you are a licensee under.Chapter 455,F.S.,please click here. i Product Approval Accepts: M = ® ar«_ E I Credit Card Safe I i i I https://www.floridabuilding-or.g/pr/pr app dtl.aspx?param iwGEVXQwtDgsJ9a49YAgX... 10/12/2019 EVALUATION REPORT OF UNION CORRUGATING COMPANY j 126 GA.5V PANEL'- , FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 20484.1-R1 ! ROOFING METAL ROOFING f 'Prepared For: Union Corrugating Company 701 S.King St. Fayetteville,NC 28301 Telephone: (910)483-0479 Fax: (910)483-1091 i Prepared By-: ]Bala.Sockatingam,P1i.D:,P.& Florida Professional Engineer#62240 1216 N Lansing Ave.,Suite C Tulsa, OK'74106 i Telephone: (918)492-5992 i FAX: (866)366-1543 This report consists of Evaluation Report(3 Pages.including cover) installation Details (1 Page) 6��®ge��} Gags®a®� ! Load-Span Table.(1 IPlkge) w�� G� AV s��T a 2 co ' d �0 6 V a � o Y OF e ! LU Report No. C2175=1 d =�' '�� •C, '' Date: 8.23.2017 , s� .o°••• F 0 i y FL 20484.1-RI . C2175-1 8.23.2017 Page Z of 3 I ; Manufacturer' Union Corrugating Company Product Name: 5V Panel Panel.Description: 24"wide.coverage with(5)1/2"high ribs } Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). i Deck Description: Min. 1.5/32" thick APA rated plywood or min. 3%4' thick wood plank I (min SG of 0.42) for- new and existing constructions. Designed by others and installed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction. I Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt. For reroofing ! (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2 Design Uplift Pressure: 71.0 psf @ fastener spacing of 24" o.c. (Factor of Safety=2) 169.0 psf @ fastener spacing of 6" o.c. Panel Attacl-nnent: #10=15 x 2" long wood screw with washer At interior @ max 12" o.c. across panel width through panel rib i At panel ends @ max 6" o.c. across panel width through panel flat and rib Test Standards: Roof assembly tested in accordance-with ULS80-06 `Uplift Resistance j of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering Systems'. Test Equivalency: The test procedures in UL 1997-04 comply with test procedures prescribed in UL 1897-12. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design.. The maximum fastener spacing listed herein shall not be exceeded.. The design pressure for_reduced fastener spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Union load span table. This evaluation report is 4 I FL 20484.1-R1 C2175-1 8.23.2017 Page 3.of 3 I not applicable in High Velocity Hurricane Zone.Refer to current NOA i for use of this product in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials , directory or ASTM E108AM7910 report from an'accredited laboratory for fire ratings of this product.. I Supporting Documents: UL580 &UL1897 Test Reports1i j Farabaugh Engineering and:Testing Inc. Project No.T197-16,Reporting{IDate 5/12/16 i i i I I r i i unnxrron aim m: PANEL OVERLAP as NEW UNDERLAYMENT - - - PANEL:FASTENER ROOF PANEL � SEE DETAIL 2 SEE DETAIL I SPACING-PER-ALLOWABLE~ .— UPLIFT LOAD TABLE - { B . .u� \ ..✓ \ .�' EXISTING`UNDERLAYMENT EXISTING SHINGLES, DECK'ATTACHMENT AND PLYWOOD (OPTIONAL) (OPTIONAL) SUPPORTS MUST BE 15/32"`THICK (MIN.) DESIGNED AND INSTALLED BY OTHERS MIN. 2X WOOD RAFTER/JOIST/ TRUSS FT MAX. 24" O.C. TYPICAL PANEL INSTALLATION X—SECTION � Lino C9'WN N. #10-15-X 2" LONG WOOD No SCREW WITH WASHER < z z»a Ix Y� O � I MIN 26 GA. PANEL o g o NEW UNDERLAYMENT EXISTING SHINGLES' (OPTIONAL)' I EXISTING UNDERLAYMENTS_ (OPTIONAL) PLYWOOD THICK (MIN.) z . IL DETAIL 1 Z a GENERAL NOTES- > z Q 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE #10-15 X 2" LONG WOOD FLORIDA BUILDING CODE (FBC), o I SCREW WITH WASHER 2. ROOF PANELS SHALL BE MINIMUM 26 GA. EFFECTIVE COVERING WIDTH OF PANEL - 24". - 3, THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS g o NEW UNDERLAYMENT MIN 26 GA. PANEL SPECIFIED ON THIS DRAWING, 4. REQUIRED DESIGN WIND LOADS SHALL BE`DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT, BE INSTALLED WHEN THE REQUIRED DESIGN WIND,LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE. 5. ALL FASTENERS MUST BE IN.ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM EXISTING SHINGLES REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. (OPTIONAL)' 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION,AND ARE THE RESPONSIBILITY OF OTHERS. EXISTING;UNDERLAYMENT _�!PLYWOOD (OPTIONAL) DETAIL 2 15/32"THICK (MIN.) C21 75-1 lv- sr+Er ea. OF I UNION CORRUGATING COMPANY � 5V Panel Uplift Loads (Min 26 ga.) 1 Description- Fastener Spacing. F Allowable Uplift along Panel Length Load is (in) j (psf) Coverage width: 24" 6 ! 169.0 8 i 158.1 Panel Fasteners _ -__----_ -- 10 _ _ 147.2__ -_- -�--_ #10-15 hex head screws with — ~12^ 136.3 sealed washer -----._- 14 -.---- - _--- ------'121.7---------_ � 16 106.5 Panel fasteners'spaced at 12" 18 94.7 o.c. across panel width -- - --�� -� ~85.2 — -- i through ribs. - - — 2_ ---- ----- -_ 77.5 Notes: 1. The bold numbers indicate design loads calculated from test data with safety factorof 2. 2. Panels must be installed as per Evaluation Report FL 20484.1 and Union current installation procedure. i i i ' 46�,a9�HH8�aB�� 50 °... S ° �'<s Q V 6 n O m L CO G e a i W OF elm 1216 N Lansing Ave:,Suite G �� �L.�,•�9.,�t 1�,- Bala Sockalingam,Ph.D.,P.E. Tulsa,Ok 74106 -�''— FL 62240 918 492'5992 � t IvAi_ i METAL ROORNO SUPPLY".° Knois ledge—Service-,Seleetiona` ShIce 1998. 1-17-2020 To whom it may concern, lit Coast Metal Roofing Supply Florida product.approval km section 5 paragraph 2 references ' re-roofing applications shall be inst€tlled in.a6i ordi6ce with the 2017 Florida Building Codes Section 1507.4& 1511..for.the re-covering over existing ro66.We apprgye^our product over existing roof and th 'use of'`Ultia HT`V ind&::Water Seal"^under the roof covering system (optional Whex there is Secon water barrier existui ). Sincerely,"E., Customer,Service , gggS e I e £ I - 1 i 1 : qqE :,�, �, MEN E.&� �,d w WIN } f