Miami-Dade County Building
Product Information for N.O.A. 17-1107.04
NOA 17-1107.04 L1_(libraW 0ductc0ntr01/n0a/17110704.p�_
Superseded—By
File Status File Approved
File Classification' High velocity hurricane zone
Category Roofing
Subcategory Ventilation
Material Plastic
Applicant Owens Corning Roofing and Asphalt LLC(op-result detail app.asp?a?a pp alias=100938)
Expiration—Date October/31/2022
Impact Rate Unselected/Unknown
Maximum_Design_Pressure_Positive 0
Maximum_Design_Pressure_Negative 0
Description VentSure Ridge Vent
Green Sustainable Attributes NONE
For a detailed description on the File Status, click the NOA File Status Key_ftuildingft-resulL key_epp.aspj
Page Last Edited:Wed Jan 25,2017 10:40:27 AM
MIAMI.OIADE
LXCUM
http://www.miamidade.gov/building/pc-result app.asp?fldNOA=17-1107.04&...ubcategorylist=0&materiallist=0&impactlist=0&fldMDPP=0.00&fldMDPN=0.00 Page 1 of 1
1
MIMI®1DE
� MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Owens Corning
1 Owens Corning Parkway
Toledo,OH 43659
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: VentSure®Ridge Vent and VentSure®Rigid Roll Ridge Vent
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date,may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA# 13-1010.04 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-1107.04
Muu�anaoe courlrr Expiration Date: 10/31/22
Approval Date: 12/21/17
Page 1 of 5
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Ventilation
Material:' Plastic
Minimum Slope: 3:12
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Product Dimensions Test Product
Specification Description
VentSure®Ridge Vent 11-'/4"wide, TAS 100(A) Ridge ventilation system for asphalt shingle
5/8"high, roofing systems.
lenths of 4' &8'
VentSure®Rigid Roll 11-'/4"wide, TAS 100(A) Ridge ventilation system for asphalt shingle
Ridge Vent 5/8"high, roofing systems.
lenths of 20'&50'
TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS:
Test Product
Product Dimensions Specification Description Manufacturer
Asphalt Roof Cement ASTM D 4586 Asbestos-free,asphalt based Generic
roof cement
Asphalt Primer ASTM D 41 Asphalt Primer Generic
Roofing Nails 2 ''/z"long TAS 114 Corrosion resistant annular ring Generic
shank nails
Roofing Sealant TAS 132 Polyurethane adhesive sealant Generic
MANUFACTURING LOCATION
1. ML#1
EVIDENCE SUBMITTED
Test Asency/Identifier Name Report Date
Architectural Testing Inc. ASTM D 635 C1774.01-109-18 09/06/13
ASTM D 1929 C1774.01-109-18 09/06/13
ASTM D 2843 C1774.01-109-18 09/06/13
TAS 100(A) 01-38660.04 04/25/01
TAS 100(A) 01-38660.05 04/25/01
TAS 100(A) C1774.01-109-18 09/06/13
Underwriters Laboratories,Inc. UL 790 R21038 12/08/03
NOA No.:17-1107.04
Mwhtbowuecour�7Y Expiration Date: 10/31/22
Approval Date: 12/21/17
Page 2 of 5
a
APPROVED APPLICATIONS
Tradename: VentSure®Ridge Vent and VentSure®Rigid Roll Ridge Vent
System Type: Mechanical attachment of ridge vent system over composition shingles.
Cutout:
1. Determine whether the rafters are truss or ridgepole
construction. Cut sheathing 2"(truss)or 3-1/2"(ridge
pole)wide slot(1"truss or 1-3/4"ridge pole on each side)
jof the ridge(s). A minimum of 6"must be left uncut on
j each end of the ridge. Once the slot is cut and any
overlapping shingles covering the ridge are trimmed and
removed,the ridge is ready for vent installation.
Installation:
2. Place the VentSure®Ridge Vent or VentSure®Rigid Roll
Ridge Vent,routed side down along entire length of slot
also covering the 6"minimum uncut ridge on both ends.
Multiple lengths of vent can be joined by butting them
together.
3. Pull apart a 3"or 5-1/4"precut section of the foam endcap.
Using an approved construction adhesive or sealant caulk,
coat both sides of the foam material where it has been cut
back at the end of the vent.Insert the foam end cap with the
cut back foam material between the foam end cap and the
underside of the vent to assure a weather-tight seal.
Approved sealant must be applied to roof shingles before
installing vent.
4. Using four(4)2 '/z"long corrosion resistant ring shank
roofing nails,attach vent to the roof deck by driving a nail
in each of the two corners on both ends of the vent,and a
nail at each side through the foam cap. Use 2 '/2"long
corrosion resistant ring shank roofing nails at 24"on center
across the downslope of the ridge to attach vent.Apply an
approved polyurethane adhesive sealant at the down-slope
leading edges of the ridge vent,at the junction of the
leading edge and asphalt shingles.
MIAMFDADE COUNTY NOA No.: 17-1107.04
Expiration Date: 10/31/22
Approval Date: 12/21/17
Page 3 of 5
5. After vent has been installed,cut ridge shingles,preform,
/. t,•' and install the cap shingles directly to the vent,in
compliance with the shingle manufacturer's Notice of
Acceptance(NOA)and installation instructions.Lap
shingles with a 5"exposure over the ridge vent in a
common overlapping pattern and attach using 2 '/2"long
corrosion resistant ring shank roofing nails through the
ridge vent into the wood deck.
Net Free Area: Refer to manufacturer's published literature.
LIMITATIONS:
1. Refer to applicable Building Code for required ventilation.
2. WntSure®Ridge Vent and VentSure®Rigid Roll Ridge Vent shall comply with the manufacturer's current
published application instructions and the requirements set forth in the applicable Building Code.
3. VentSure®Ridge Vent and VentSure®Rigid Roll Ridge Vent shall not be installed on roof mean heights greater
than 33 feet.
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the
Miami-Dade County Product Control Seal as shown below:
MIAM!•QADE COUNTY
NOA No.: 17-1107.04
MIAMFDA EC
O'rig TY 11 Expiration Date: 10/31/22
Approval Date: 12/21/17
Page 4 of 5
DETAIL DRA�,ING5
NTSU�®EDGE VENT
VE AND VENT
®RIGID ROI'I'RIDGE
VENTSuRE
2 '
.cvisr�s-reaiv �ii- i �r�s"�li:rz-�m
C?Il.3l
825 rrrrrc���ri--------- r�rsrfsc�.rrrsllir�
11.25
OF
I�.IS ACCEpT�CE
END T
xOA No.: 10131122
Expiration Date:
Approval Dat p ge g]of 5
MFo��d-ourrcY