Loading...
HomeMy WebLinkAboutProduct Approval i iulsutzuia Florida Building Code Online Business & Professional Regulation User Registration I Hot Su It Surcharge Stats&,Facts PuM tlbM. Cotits�t Uf;I SCIS Site Map Bt75 Nome Log In � links� 5l+tdi.I L'Pirnd�iict;Appra..►a1. ,1lSER bitiiicltmr• Product Aoomval Menu>Product or Aoolicntion search:,Aoolication List Application Dotaa FL# FL30674-Ri5 Application type Revision Code Version 2017 Application Status Approved Comments Archived i-4 Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant r H 4365 Address/Phone/Email 1 Owens Corning PKWY T419 0oled ,3706-8360 9 mel.sancrant@owenscomig.com Quality Assurance Representative ey—m Address/Phone/Email Category Roofing .24 tla.- og37 Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M.Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies,LLC. Quality Assurance Contract Expiration Date 04/20/2020 Validated By John W.Knezevich,PE. Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R15 COI 2019 01 COI NIEMINEN.p_df Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code httpsJ/Noridabuilding.orgfpr/pr app dti.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahRegiCQ8ucR6ixEDL76gG32Q9MA%3d%3d 1/2 F � NEMO etc. Certificate of Authorization#32455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION Owens Corning Evaluation Report 037940 02.12-1110 One Owens Coming Parkway FL10674-RlS Toledo,OH 43659 Date of Issuance:02/06/2012 (740)4047829 Revision 10: 08/15/2019 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described herein have been evaluated for compliance with the 60'Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: .Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/1190S.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility location(s). NEMOI.etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: 4 Owe. �t ti Robert J.M.Nieminen,P.E. - %��.A, •' :tip '•'•= The facsimile seal appearing was authorized by Robert 4� �.r�•yams `,• Nieminen,P.E.on 08/15/2019.This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 "..���M;.:����' Pip dronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO Ietc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company.manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building.code evaluation. Neither NEMO I etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018,NEW ETC,LLC MEMO etc. ROOFING SYSTEMS EVAWATION: s• Product Category: Roofsng Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6th Edition(2017)Florida Building Code and Florida Building Code,Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations J Conditions of Use set forth herein. STANDARDS:2. aar ` ��G '+:zu_n�d8td,�. .. x 1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5,R905.2A Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161. 2016 15072.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI(TST5818) ASTM D2970 OCF-382-02-01 10/24/2017 UL LLC(CER9626) Physicals&Wind Resistance . File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various PRI(QUA9110) Quality Control Service Confirmation 04/05/2020 4. PRODUCT DESCRIPTION: I z 41= ActEssoRtr=STAItsERs 4.1.1 Starter.Strip Shingle,Starter Strip Plus and SRS TopSh`leld Starter are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 Starter Shingle Roll is a mineral-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen starter strip, nominal 7.2-inch wide x 33-ft 4-inch long roll,for use with asphalt shingles. Meets ASTM D1970. 4.2 :ASPHALT SHINGLES `_• 4.2.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.Meets ASTM D3462. 4.2.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. Meets ASTM D3462. 4.2.3 Duration j TruDefinition' Duration%Duration Premium Cool,TruDefinition' Duration'Designer Color Collection, TruDefinition' Oakridge', Oakridge* and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles.Meets ASTM D3462. 4.3 FIIP&RIDGE SHINGLES: 4.3.1 Berkshire Hip&Ridge Shingles with Sealant,DuraRidgelb Hip&Ridge Shingles with Sealant,ProEdge6 Hip&Ridge Shingles and WeatherGuard'HP Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. Meets ASTM D3462. NEMO ETC,LLC Evaluation Report 037940.02.12-R10 Cerd}kvte of AuthortzoHon#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R35 Owens Corning Asphalt Roof Shingles Revlsion 10:08/15/2019 Page 2 of 10 I "NEM0 etc. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in anyway,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. S.4 Wind.-Classification. 5.4.1 The Owens Coming asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and 11905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H;indicating acceptable use in all wind zones up to V.,d=150 mph Vit=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note:Classification by ASTM D7158 applies only to exposure category B or C,as defined in FBC 1609.4.3,and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.2 Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating acceptable use in all wind zones up to Vaw=150 mph(V„It=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. 61 GENERAL INSTALLATION: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / 11905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 611320-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC. 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof(tear-ofd or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2- ACCESSORY STARTERS: - 6.2.1 Installation of Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions,using minimum five(5)nails per strip. hNnawaff'.W Deck —ow 6464.09Wc4w _ s.ttw,r.a `remM i �y i l W"dwi w ma.4pn.N •aw , Ne1b bated Y=Tknmeew aV•1�n taemsac oe40skQh.onmw Styter StlIP�Yb onhenpeeevae end rakes 1t=Yi katter WlprWa.r.MM.�n eeduhe Utti]7P Figure 1:Minimum Nailing,Starter Strip Figure 2:Minimum Nailing,Starter Strip Plus NEMO ETC,LLC Evaluation Report 037940.02.12-RSO Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-RlS Owens Corning Asphalt Roof Shingles Revision 10:08/iS/2019 Page 3 of 10 '-NEnne etc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Coming current published instructions. Deck .Undettayment Drip edge .'. Starter Shingle Roll adhered dirediy to undedayment and ,. primed drip edge -Self-sealing adhesive Positioned along eaves Figure 3:Starter Shingle Rall 6 3 . ASPHALT SHINGLES; � _- - - 6.3.1 Installation of-asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: Berkshire'shingles require minimum five(5)nails per shingle. WeatherGuard'HP shingles require minimum six(6)nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Classic--&Supreme: Normal Mansard or Area para Normal Mansardor Area para Wind Arasa High Wind dowenes y Wind Areas Nigh Wind dasranes.ir Area i7w►t vie�rtoa normafea. Areas visntos lmertes Area pan vientos normaW Ares vientos fuartos (A) _ .._ �" �• z• IB 2• s" �" IAL �• 2 . Z• r f • IBI 9'Exposure 6 sdr Exposure Fx"sicide Eaposieldn Figure 4:Minimum Nailing,Classic&Supreme Figure S:Minimum Nailing,Classic&Supreme (Standard Size) (Metric Size) NEMO ETC,LLC Evaluation Report 037940.02.12-1130 Certificate of Auth.orization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FU0674-RIS Owens Coming Asphalt Roof Shingles Revision 10:08/15/2019 Page 4 of 10 i _ NEMO etc. 6.3.1.2 Berkshires Sem4nt`.aAr s�alants}rlp ::♦:ilritdps fidgr LA1*s WbdiW FF 6 9Yt' 91Y Lj - '`r.!Btu' ate- aVF asy-�. �• Figure 6: S-Nail Pattern,Berkshire Figure 7: 6-Nail Pattern,Berkshire Spabdtstrip r;a8radetetha6r «-tee a-i i e�---►• ---------Wo '`r s yr svr s.vr s rr ,..= � Asphatt�ioofiegeement ' CanpOtadata&*bM0 Figure 8: Mansard or Steep Slope Pattern,Berkshire NEW ETC,LLC Evaluation Report 037940.02.12-R10 Certificate Of Authorization#32455 0 EDITION(2017)FSC NON-HVHZ EVALUATION FL10674-RIS Owens Coming Asphalt Roof Shingles Revision 10:08/15/2019 Page 5 of 10 ONEMOjetc. 6.3.1.3 Durations:TruDeflnition•Duration,Duration*Premium Cool&TruDeftnition-Duration Designer Color Collection: 44bilPastening Pattem ;`-' 9irieNa9� arsa'�Itllh maii,.'1)rpiw Figure 9:Standard 4-Nall Pattern,Duration ".9,1l fastening PatWn SunNaWfA0.019m x"taid1h NA Typical. - i rm-1: Figure 10: 6-Nail Pattern,Duration Fastening for Sloes Greater T!"1112 Sun4fieil®hstening Brea width NaILTypIcal € iC # ff • Four l"Spots of :-'-ilt Roofing Comets Figure 11: Mansard or Steep Slope Pattern,Duration NEMO ETC,LLC Evaluation Report 037940.02.12-R10 Certificate of Authorization#32455 6TM EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 6 of 20 NEMO etc. 6.3.1.4 TruDeflnition'Oakridtie'.Oakridgeo:. 4.Natl:Pattan BquiWi6xi 4 dams err " 6618"FippaureAll6 Ei/g"6x6osttA estof6e de 66/Bp4fg giros Exposfof dr 6WB prtt� ' Figure 12:Standard 4-Nail Pattern,Oakridge fi�Nag Patton . Esq vm-eon 6 dms 1 lY.i 6 618"Ekposure Mvw 6..618"Eiglosa�ie Eiporstaf6n deF6/8pvlg Ezpdsloidiidf 56/8prt1� Figure 13:6-Nail Pattern,Oakridge -FioteningforSlgmGfcaterTh®n2t:12 .-sunNdof�hntnpm■wulei fU147ypk. r :.{3a.Mab �,-?'.?•:�IOPrI � fYlj - _=�VW�l`ttiC.W► . . Fg FourIll Spm otA■pra!Rooflnp C=m Figure 14:Mansard or Steep-Slope Pattern,Oakridge MEMO ETC,LLC Evaluation Report 037940.02.12-1110 Cerd trate ofAuthorizotion#31455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-RIS Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 7 of 10 ONEMO-Jetc. 6.3.1.5 WeatherGuard•HP: �P 1 . <PK� Ihi OLa� 5E�eiaddtd sop* �fi��ua Figure IS:6-Nall Pattern,WeatherGuard HP =4Nown eoarnn 6 dam Nell 6118'frombbi am of*4e 5 ON Expoare perste irdtrad8al'wur8de te.te�ah 8 Festenas Elio"de 5 518 plrg. 8=ujetadares. -I Four 1'Spats of Asphalt hoof Cement Co0apuma de came M de ted_ de&*&ds 1 p owk Figure 16:Mansard or Steep-Slope Pattern,Weatherduard HP HIP Bit RIDGE sH1NylF3. 6.4.1 Installation of asphalt shingies shall comply with the Owens Corning current published instructions. ➢ Berkshire' Hip and Ridge Shingles with Sealant and Durallidge® Hip & Ridge Shingles with Sealant require minimum two(2)nails per shingle. ➢ WeatherGuard' HP Hip and Ridge Shingles and ProEdge® Hip & Ridge Shingles require minimum four(4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations.. NEMO ETC,LLC Evaluation Report 037940.02.12-1110 CertiflcateofAuthorization'#32455 0 EDITION(2017)FRC NON-HVHZ EVAWATION FL10674-R35 Owens Coming Asphalt Roof Shingles Revision 10:08/15/2019 Page 8 of 10 "NEMo etc. 6.4.1.1 Berksh(re'!M10&Ridge-with Sealant and Dgga ljgem Hia&Ridge Shieftles with Sealant: Fig.A Prevailing Wind Direction Fig. B Top View Dir 6n ilei vieeto predontinante A Vista superior � 2% Claw Malls, Clams - I I I I A: I I I` I Ir z l m did oar �1Q A 12° ___._ Figure 17:Isometric View,Berkshire and DuraRidge Figure 18:Plan View,Berkshire and DuraRidge 6.4.1.2 WeatherGuardP.HP.Hl0.&Rids e.Shinkles: Fig.A 4 4 Fig G Hip.&Ridge Shingle Fastening �_PrGweln9 Wild TopVgw - . Dliodbn - p - .. I 2"11 ' i w _ 8' EI[posure lit Figure 19:Isometric View,WeatherGuard HP Hip&Ridge Figure 20:Plan View,WeatherGuard HP Hip&Ridge NEMO ETC,LLC Evaluation Report 037940.02.12-R10 Certlficote of Authorizadon#32455 6-EDITION(2017)FBC NON-HVH2 EVAWATION FL10674-RIS Owens Coming Asphalt Roof Shingles Revision 10:08/15/2019 Page 9 of 10 NEMO etc. 6.4.1.3 ProEdKe!Hio&Ridge ShIrikles: Pnvang- - Standard r--�f■-- iWitd D'Reetian � P Patt"Fastening 6■FJIPBSWo ■ Flift Vhd Th■ 8F Exposm CswFjqpsW ,.F w10 - -- — Figure 21:Isometric View,ProEdge Figure 22: Plan View,ProEdge 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FEIC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product PLANTS:9. MANUFACTURING Contact the named QA entity for information on which plants produce products covered by I-lorida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies,LLC-QUA9110; 813 621-5777;bwilson@pricmt.com END OF EVALUATION REPORT- NEW ETC,LLC Evaluation Report 037940.02.12-R30 Certiftcate ofAutharizotion#32455 6-EDITION(2017)F8C NOM-HVHZ EVALUATION F1.10674-1135 Owens Corning Asphalt Roof Shingles Revision 10:08/35/2019 Page 10 of 10