HomeMy WebLinkAboutProduct Approval 7/30/2019 Florida Building Code Online
lit
y
SCIS Home I Login ' User Registration I Hot Topics j Submit Surcharge Stats&Facts Publications Contact Us ( BCIS Site Map I Links Search
a Al
uim
Product Approval
USER:Public User
dbpr RECEIVED
Product Approval Menu>Product or Application Search>Allication List>Application Detail
$ FL# F11-1654-1124 FEB 10 �0?0
Application Type Revision
Code Version 2017 ST. Lude County, Permitting
Application Status Approved
Comments
Archived t
Product Manufacturer 0LYGLASS USA
Address/Phone/Email 111 W.New Ft'Center Drive
Dee le each,FL 33442
(954)233-1330 Ext 242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative Maury Alpert
Address/Phone/Email 1111 W.Newport Center Drive
Deerfield Beach,FL 33442
(912)429-8610
MAlpert@polyglass.com
aa
Quality Assurance Representative Y Address/Phone/Email `! L$J
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 09/13/2021
Validated By John W.Knezevich,PE
i ' Validation Checklist-Hardcopy Received
Certificate of Independence FL1654 R24 COI 2019 01 COI NIEMINEN.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D6162 2008
ASTM D6163 2008
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2009
FM 4470 2012
FM 4474 2011
OL1897 2012
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvgqu2w°/a2bnFgUPv2pw6pKxAh9p/a2fJTtiNgcLHGg1ZFglMqIAp/o3d°/p3d 1/2
, 9
7/30/2019 Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/12/2019
Date Validated 04/14/2019
Date Pending FBC Approval 04/19/2019
Date Approved 06/18/2019
Summary of Products
FL# Model,Number or Name Description
1654.1 Polyglass SBS and APP Modified SBS and APP modified bitumen roof systems
Bitumen Roof Systems
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL1654 R24 II 2019 04 FINAL Al ER POLYGLASS MODBIT FL16 4-
Approved for use outside HVHZ:Yes R24.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes
Other: 1.)The design pressure in this application Evaluation Reports
relates to one particular assembly over concrete deck. FL1654 R24 AE 2019 04 FINAL ER POLYGLASS MODBIT FL1654-
Refer to the ER Appendix for other systems and deck R24.Off
types.2.)Refer to ER,Section 5 for other Limits of Created by Independent Third Party:Yes
Use.
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy,Statement::Accessibility,Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
W731 li�
MR M
Credit Card
Safe
hftps://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKxAh9%2fJTtiNgcLHGglZFglMqIA%3d%3d 2/2
(19NEMOjetc.
APPENDIX 1:ATTACHMENT RUIUIREIVIENTS FOR WIND UPLIFT RESISTANCE
TABLE DECK APPLICATION TYPE DESCRIPTION PAGE
1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 5
1B Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5-9
1C Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 10-11
1D Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 12
1E Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 12-14
1F Wood New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 15-18
1G Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 18-22
1H Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 23-28
11 Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 29
2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover •30-32
2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 33-37
2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-1 Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 38-39
2D Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-2 Insulated,Mech.Attached Velociflex,Bonded Roof Cover 40-41
3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 42-50
3B Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 50
4A Lightweight concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 51-53
413 Lightweight concrete New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 54
4C Lightweight concrete New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 55-58
5A Cementitious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 59
5B Cementitious wood fiber New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 60
5C Cementitious wood fiber New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 61
SD Cementitious wood fiber New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 61
5E Cementitious wood fiber New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 61
6A Existing gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 62-64
6B Existing gypsum Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 64
6C Existing gypsum Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 64
6D Existing gypsum Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 64
7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 65-69
78 I Various Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover 69
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement:
➢Wood: Minimum 0.75-inch penetration.
➢Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
NEMO ETC,LLC Evaluation Report P9290.02.08-R22 for FL1654-R24
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 22:04/11/2019
Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 1 of 69
OMEMO I etc.
3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanurate,polystyrene,wood fiberboard,perlite,gypsum-based roof board or mineral-wool roof board that meets the QA requirements
of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover.
4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base sheet
fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural
members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval
documentation.
5. Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016).
6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions.
➢ Hot asphalt(HA): Full coverage at 25-30 lbs/square.
➢ Dow INSTA STIK Quik Set Insulation Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.
➢ Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c.
➢ Millennium PG-1 Pump Grade Adhesive(M-PG1): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c.
➢OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.(PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced.
➢OlyBond Classic(OB Classic): Full coverage at 1 gal/square.
➢ ICP Adhesive&Sealants Polyset CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c.
➢Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered.
➢Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the
thinner board listed below maybe used as a drop-in for the equivalent thicker material listed in the table:
➢ Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick)
➢ Millennium PG-1 Pump Grade Adhesive(M-PGI): MDP -157.5 psf (Min.0.5-inch thick)
➢OMG OlyBond 500(OBS00): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3)
➢OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GL)
➢OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch thick ENRGY 3)
➢OMG OlyBond 500(OB500): MDP -487.5 psf (Min.0.5-inch thick ACFoam II)
➢ ICP Adhesives&Sealants Polyset CR-20: MDP -117.5 psf (Min.1.0-inch thick)
8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention
Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk'carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data
Sheet 1-29(January 2016)for Zone 2/3 enhancements.
10. For fully bonded assemblies,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted.
11. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing
roof system(for recover)shall be capable of resisting project design pressures on Its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with
ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D,the Insulation is optional;however,the existing roof system shall be suitable for a recover application.
NEMO ETC,LLC Evaluation Report P9290.02.08-R22 for FL3654-R24
Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION Revision 22:04/11/2019
Prepared by: Robert Nleminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 2 of 69
OMEMO I etc,
14. Lightweight Insulating Concrete(LWC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced,refer to current LWC
Product Approval for specific deck construction and limitations. Unless otherwise noted,for systems where specific LWC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat
thickness is 2-inches. For LWC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent"LWC references,listings were established through testing over lightweight concrete cast
using only foaming agent(ASTM C896),water and Portland cement(ASTM C150),with no proprietary additives,in accordance with procedures adopted by Miami-Dade BCCO(FBC CER1592). Unless otherwise noted,
use of these listings in new construction or re-roof(tear-off)applications is at the discretion of the Designer or Record and Authority Having Jurisdiction.
15. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications.
POLYGLAss ROOF COVERS
REFERENCE LAYER MATERIAL APPLICATION
BP-AA Base Ply One or more plies Polyglass G2 Base,FBC Approved ASTM D4601,Type II Hot Asphalt at 20-40
(Base and Ply sheets, Ply One or more plies Polyglass Ply IV,Polyglass Ply VI,FBC Approved ASTM D2178,Type IV or VI lbs/square
Asphalt-Applied) Note: Asphalt-applied sheets or insulation shall not be applied to poly film surfaced membranes.
Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 HP,Elastoshield HT PG350 at 1.5-2.0
SBS-CA1 Cap Ply Elastoflex V G,Elastoflex V G FR,Elastoflex S6,Elastoflex S6 HP,Elastoflex S6 G,Elastoflex 56 G FR,Elastoshield TS G,Elastoshield TS gal/square
G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed)
Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 HP Polyplus 35 at 1.5-2.0
SBS-CA2 Cap Ply Elastoflex V G,Elastoflex V G FR,Elastoflex S6,Elastoflex S6 HP,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS G,Elastoshield TS gal/square
G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed)
Base Ply or Ply One or more plies Elastobase(sand/sand or poly/sand),Elastobase P(sand/sand or poly/sand),Elastoflex V,Elastoflex S6,Elastoflex
56 HP,Elastoshield HT
SBS-AA Elastoflex V,Elastoflex V G,Elastoflex V G FR,Elastoflex S6,Elastoflex S6 HP,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS G, Hot Asphalt at 20-40
(SBS,Asphalt Applied) Cap Ply Elastoshield TS G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) lbs/square
Note: Asphalt-applied sheets or Jnsulation shall not be applied to poly film surfaced membranes.
SBS-TA Base Ply or Ply One or more plies Elastobase(sand/poly),Elastobase(poly/poly),Elastoflex V,Elastoflex S6,Elastoflex S6 HP,Elastoshield HT
(SBS,Torch-Applied) Cap Ply Elastoflex V,Elastoflex V G,Elastoflex V G FR,Elastoflex S6,Elastoflex 56 HP,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS G, Torch-Applied
Elastoshield TS G FR,Polyfresko G SBS(poly-film backed),Polyfresko G SBS FR(poly-film backed)
Base Ply One or more plies Elastoflex SA V,Elastoflex SA V FR,Elastoflex SA V Plus,Elastoflex SA V Plus FR
SBS-SA Cap Ply Elastoflex SA P,Elastoflex SA P FR,Polyreflect Self-Adhering
(SBS,Self-Adhering) Note: Unless otherwise noted,permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein,
Elastobase(poly/sand)or Elastobase(poly/poly).
APP-CA1 Cap Ply Polyflex G FR PG350 at 1.5-2.0
gal/square
APP-TA Base Ply or Ply One or more plies Polyglass Base,Polyflex,Polybond Torch-Applied
(APP,Torch-Applied) Cap Ply Polyflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FR
APP-SA Cap Ply Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polykool
(APP,Self-Adhering)
Note: Unless otherwise noted,permissible membrane substrates for APP-SA are limited to the SBS-SA Base Ply options herein, Self-Adhering
Elastobase(poly/sand)or Elastobase(poly/poly).
NEMO ETC,LLC Evaluation Report P9290.02.08-R22 for FL1654-R24
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 22:04/11/2019
Prepared by: Robert Nleminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 3 of 69
ON EMO I etc.
16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure(MDP)limitations. The lesser of the MDP listings below vs.those in Table 3A
applies:
VAPOR BARRIER OPTIONS; . DECK;
OPTION PRIMER VAPOR BARRIER
` INSULATION ADHESIVE MDP(PSF)
# TYPE ATTACH
VB-1. PG100 Elastoflex SA V Plus Self-Adhering Inta-Stik or CR-20,12-inch o.c. -60.0
VB-2. PG100 Polyglass Base Torch-applied Inta-Stik or CR-20,12-inch o.c. -75.0
VB-3. PG100 Elastoflex SA P Self-Adhering Insta-Stik,12-inch D.C. -75.0
VB-4. PG100 Elastoflex SA P Self-Adhering Millennium One Step Foamable Adhesive,12-inch o.c. -157.5
VB-5. PG100 Elastoflex SA P Self-Adhering CR-20,12-inch D.C. -270.0
VB-6. PG100 Elastoflex SA V,Elastoflex SA V FR,Elastoflex SA V Self-Adhering Millennium One Step Foamable Adhesive,Millennium PG-1 Pump Grade -290.0
Plus,Elastoflex SA V Plus FR Adhesive,OlyBond 500 or CR-20,12-inch o.c.
17. The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings for
application limitations and a Roofing Materials Directory for fire ratings associated with coating usage.
SURFACING OPTIONS FOR OOLYGLASS MODIFIED BITUMEN ROOF SYSTEMS
Option# Surfacing Florida Product Approval
SURF-1. PG300 Fibered Roof Coating FL10291
SURF-2. PG600 Non-Fibered Aluminum Roof Coating FL10291
SURF-3. PG650 Fibered Aluminum Roof Coating FL10291
SURF-4. PG700 High Quality Elastomeric Roof Coating FL10291
SURF-5. PG700QS(Quick Set)High Quality Elastomeric Roof Coating FL10291
SURF-6. PG800 Asphalt Emulsion Roof Coating FL10291
SURF-7. Polyplus 60 Premium Non-Fibered Aluminum Roof Coating FL10291
SURF-8. Polyplus 65 Premium Fibered Aluminum Roof Coating FL10291
SURF-9. Polybrite 70 Premium Grade Elastomeric Roof Coating FL10291
SURF-10. Polybrite 70QS(Quick Set)Premium Grade Elastomeric Roof Coating FL10291
SURF-11. Polybrite 71 HS FL10291
SURF-12. Polybrite 90 High Solids Silicone Roof Coating FL10291
SURF-13. Polybrite 95 Silicone Roof Coating FL10291
SURF-14. KM Acryl 15 FL27409
SURF-15. KM Acryl 15 QS FL27409
SURF-16. KM Acryl 25 FL27409
SURF-17. KM Acryl 25 QS FL27409
SURF-18. KM Acryl 40 HS FL27409
SURF-19. KM Acryl 85 FL27409
SURF-20. KM PS#250 FL27409
SURF-21. KM PS#220 FL27409
18. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads.
NEMO ETC,LLC Evaluation Report P9290.02.08-R22 for FL3654-R24
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 22:04/11/2019
Prepared by: Robert Nleminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 4 of 69
MEMO etc.
TABLE IA: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE A-1:BONDED INSULATION BONDEDROOFCOVER
System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) MDP
No. (Note 1) Type Attach I
Type Attach Base Ply Ply Cap Ply (Psf)
SELF-ADHERING BASE PLY:
Min.15/32- Min.1.5-inch Polytherm,ACFoam II,Polytherm G,
W-1 ACFoam III,ENRGY-3,Polytherm H,H-Shield,H- OB5,0 or CR-, (Optional)additional D-ISOB5 0 or CR-, (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA,
inch plywood y 08500 or CR-2D layers(s)of base insulation OB500 or CR-20 SBS-SA APP-TA SBS-TA,APP-TA 52.5
Shield CG,Multi-Max 1A3
Min.15/32- Min.1.5-inch Polytherm,ACFoam II,Polytherm G,
W-2 D-IS,M-OSFA,ACFoam III,ENRGY-3,Polytherm H,H-Shield,H- (Optional)additional D-IS,M-OSFA, Polyflex SA (Optional)APP-TA APP-TA 52.5
inch plywood Shield CG,Multi-Max FA3 OB50D or CR-20 layers(s)of base insulation OB500 or CR-20 Base
ANCHOR:1 TABLE 1B: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEMTYPEA-2: MECHANICALLY ATTACHED SHEET,BONDED'INSULATION,BONDED ROOF COVER
=No. (Note
Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15)
MDP
Type Fasten Attach Type Attach Type Attach BPas Ply Cap Ply (psf)
ASPHALT=APPLIED OR TORCH APPLIED BASE PLY:
9-inch D.C.at min.2-
inch lap and 18-inch (Optional)Min.1.5-inch Min.0.75-inch Fesco
Min. Elastobase, Polytherm,ACFoam II, Board(homogeneous)or BP-AA (Optional) SBS-AA,
Simplex MAXX o.c.at two(2), ENRGY-3,Polytherm H, Hot asphalt min.0.5-inch Structodek Hot or SBS- BP-AA or SBS-TA, -45.0
W-3 15/32-inch Elastobase P Cap equally spaced, `
plywood (sanded-top) H-Shield,H-Shield CG, High Density Fiberboard asphaltAA SBS-AA APP-TA
staggered center
rows Multi-Max FA3 Roof Insulation
9-inch o.c.at min.2- (Optional)Min.1.5-inch
0
inch lap and 18-inch Min.0.25-inch Dens BP-AA, (Optional) S
W-4 15/32-inch Elastobase P Simplex MAXX o.c.at two(2), De
Min. Elastobase, Polytherm,ACFoam II, ( P BS-AA,
ck,Dens Deck Prime, Hot SBS-AA, BP-AA,SBS-
ENRGY-3,Polytherm H, Hot asphalt SBS-TA, -45.0'
Cap equally spacedSECUROCK Gypsum-Fiber asphalt SBS-TA, AA,SBS-TA, APP-TA
plywood (sanded-top) ,staggered center MulH-Sti-Max
H-Shield CG, Roof Board YP P APP-TA APP-TA
rows
Multi-Max FA3
cp c.and 12-inch at min.2-
inchlap a (Optional)Min.1.5-inch Min.0.75-inch Fesco
inch l
Min. Elastobase, Hot Simplex MAXX o.c.at two(2), Polytherm,ACFoam II, Board(homogeneous)or BP-AA (Optional) SBS-AA,
W-5 15/32-inch Elastobase P ruc
ENRGY-3,Polytherm H, Hot asphalt min.0.5-Inch Sttodek or SBS- BP-AA or SBS-TA, -52.5
sanded-to Cap equally spaced, asphalt
plywood ( P) staggered center H-Shield,H-Shield CG, High Density Fiberboard AA SBS-AA APP-TA
rows
Multi-Max FA3 Roof Insulation
9-inch o.c.at min.2- (Optional)MinAC am 11ch (Optional)
inch lap and 12-inch Min.0.25-inch Dens BP-AA,
Min. Elastobase, Polytherm,ACFoam II, SBS-AA,
Simplex MAXX o.c.at two(2), Deck,Dens Deck Prime, Hot SBS-AA, BP-AA,SBS-
W-6 15/32-inch Elastobase P ENRGY-3,Polytherm H, Hot asphalt SBS-TA, -52.5
Cap equally spaced, SECUROCK Gypsum-Fiber asphalt SBS-TA, AA,SBS-TA, APP-TA
plywood (sanded-top) staggered center H-Shield,H-Shield CG, Roof Board y P APP-TA APP-TA
Multi-Max FA3
rows
NEMO ETC,LLC Evaluation Report P9290.02.08-1122 for FL3654-R24
Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION Revision 22:04/11/2019
Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 5 of 69
OA'
MEMO etc.
TABLE M: WOOD DECKS-NEW CONSTRUCTION ort REROOF(TEAR-OFF)
SYSTEM,TYPE F: i ► BONDED i iCOVER
System Roof Cover(Note 15)
No. Deck(Note 1) Primer Joint Treatment Base Ply Pty Cap Ply MDP(psf)
APA rated,7/16 OSB joints are covered with 4-inch wide strips of Elastoflex SA V,rolled into place to Elastoflex SA V Plus or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS-
W-182 CAT,0,418 in., None create continuous bond. Elastoflex SA V Plus FR TA,APP-TA TA,APP-TA -52.5
Exposure 1 OSB
Min.15/32-inch (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS-
W-183 plywood Nane None SBS-SA TA,APP-TA TA,APP-TA 90.0
—MiK15/324RH
W184_._ a (Optional)'PGI00`"-None PolyFlezSA Base (Optional)APPTA APf P=TA X90_0
plywood` _ ..__ I_ L
Min.15/32-inch (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS-
W-185 PG100 None SBS-SA 97.5
plywood TA,APP-TA TA,APP-TA
W-186 Min.15/3-2-inch (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- -97.5
plywood place to create continuous bond. Elastoflex SA V FR TA,APP-TA TA,APP-TA
Min.15/32-inch POLYBRITE 74S or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS-
W-187 plywood WB3000 None SBS SA TA,APP-TA TA,APP-TA 105.0
W-188
Min.15/32-inch (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Plus or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- -135.0
plywood place to create continuous bond. Elastoflex SA V Plus FR TA,APP-TA TA,APP-TA
W-189 Min.15/32-inch (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Polyflex SA Base (Optional)APF-TA APP-TA -135.0
plywood place to create continuous band.
NEMO ETC,LLC Evaluation Report P9290.02.08-R22 for FL1654-R24
Certificate of Authorization#F32455 6-EDITION(2017)FBC NON-HVH2 EVALUATION Revision 22:04/11/2019
Prepared by: Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 29 of 69