Loading...
HomeMy WebLinkAboutProduct Approval (2) i 1 4 i - BCIS Home I Log In I User Registration ; Hot Topl6 I Submit Surcharge I Stats 0 Facts I Publications Contact Us BCIS Site Map I Links I Search i Florida Product Approval P� , USER:Public User I ,. Product Approval Menu>Product or Aoollcatlon Search>Application Lis t>Application Detail FL# FL2847-R10 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archlved ❑ Product Manufacturer Lomanco,Inc Address/Phone/Emall 2101 West Main Street Jacksonville,AR 72076 (501)982-6511 acarter@lomanco.com Authorized Signature Andrew Carter acarter@lomanco.com Technical Representative Andrew Carter i Address/Phone/Email 2101 West Main Street Jacksonville,AR 72076 1 (501)982-6511 Ext361 acarter@lomanco.com Quality Assurance Representative Andrew Carter Address/Phone/Email 2101 West Main Street Jacksonville,AR 72078 (501)962-6511 Ext361 acarter@lomanco.com Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System I Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity Miami-Dade BCCO-EVIL Quality Assurance Entity Miami-Dade BCCO-QUA Quality Assurance Contract Expiration Date 08/16/2021 Validated By Miami-Dade BCCO-VAL Certificate of Independence Referenced Standard and Year(of Standard) Standard Year Miami-Dade TAS 100(A) 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option C Date Submitted 0 8/2 712 0 18 Date Validated 09/28/2018 Date Pending FBC Approval Date Approved 10/02/2018 Summary of Products FL# Model,Number or Name Description 2847.1 Lo-OmniRidge LOR9-4 Gun Nailable 4'Ridge Vent for 9"Cap Shingles Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL2847 RIO I1 18061503-Lomanco 1_0119-4 NOA odf Approved for use outside HVHZ:Yes Verified By:Miami-Dade BCCO-EVL Impact Resistant:N/A Created by Independent Third Party: Design Pressure:N/A Evaluation Reports Other:1.Refer to applicable building codes for required FL2847 RIO AE 18061503-Lomanco LOR9-4 NOA.odf ventilation.2.Omni Roll Ridge Vent shall not be installed on roof hips.3.Omni Roll Ridge Vent shall not be connected at ridge Intersection,nor within 12"of any side wall or roof protrusion,with a ventilation slot clearance of 12"from such obstructions.4.Omni Roll Ridge Vent shall not be Installed on roof mean heights greater than 33 feet. 2847.2 Lo-OmniRoll LOR-30 30'Gun Nailable Shingle Over Ridge Vent Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL2847 RIO II 18061504-Lomanco I-OR-30 NOA.Ddf Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO-EVL Impact Resistant:N/A Created by Independent Third Party: Design Pressure:N/A Evaluation Reports Other:1.Refer to applicable building codes for required FL2847 Rio AE 18061504-Lomanco LOR-30 NOA.Ddf ventilation.2.OmniRldge Vent shall not be installed on roof mean heights greater than 33 feet. 2847.3 OmniRidge OR-4 4'Shingle Over Ridge Vent Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL2847 RIO II Lomanco OR-4-NOA 16051027.Ddf Approved for use outside HVHZ:Yes Verified By:Miami-Dade BCCO-EVL Impact Resistant:N/A Created by Independent Third Party: Design Pressure:N/A Evaluation Reports Other:1.Refer to applicable building codes for required FL2847 RIO AE Lomanco OR-4-NOA 16051027.12df ventilation.2.OmniRidge Vent shall not be installed on roof mean heights greater than 33 feet. Back Next I Contact Us::2601 Blair Stone Read.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Couvdaht 2007-2013 State of Florida,::privacy Statement::Accessibility Statement::Refund Statement 4 Under Florida law,email addresses are public records.If you do not want your e-mall address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the of ice by phone or by traditional mall.If you have any questions,please contact 850.487.1395.•Pursuant to section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The mails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ®®®R PMMW I Credit Card Safe i aCIS Home log In j User RegLstratlon i Hot TOPICS Submit surcharge I Stat; Facts I Publications Contact Us eQS Site Map Links seareh ; nwdda 41-N—R: d r Pct Approval it�'j Public User d:•a•�ikr?r ' i Qtoducr Aooroval Menu>ProduCT or AOOlication Search>AD011retlon List>Apptiratlon Detail FL FIS259-R28 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W.Newport Center Drive Deerfield Beach,FL 33442 (954)233-1330 Ext242 melpert@polyglass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative Maury Alpert Address/Phone/Emal! 1111 W.Newport Center Drive Deerfield Beach,FL 33442 (912)429-8610 MAlpert@13o]yglass.com Quality Assurance Representative Arel Lender Address/Phone/Email 1111 W.Newport Center Drive Deerfield Beach,FL 33442 (954)233-1230 iALender@polyglass.com i Category Roofing Subcategory Underlayments jCompliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nleminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/13/2021 Validated By John W.Knezevlch,PE O Validation Checklist-Hardcopy Received Certificate of Independence FL5259 R28 COX 2018 01 COT NIFMINEN,nd Referenced Standard and Year(of Standard) ,Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6164 2011 ASTM D6222 2011 FM 4474 2011 FRSA/TRI April 2012 2012 UL 1897 2012 r Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method'1 Option D Date Submitted 01/24/2016 Date Validated 0112912018 Date Pending FBC Approval 01/30/2018 Date Approved 04/10/2018 summary of Products FL O Model,Number or Name Description 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved for use In HVHZ:No FL5259 R28 II 2018 OS FINAL ER POLYGLASS UNDERLAYMENTS FL5259- Approved for use outside HVHZ:Yes R28.pa Impact Resistant:N/A Verified By:Robert Nieminen PE-59166 Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes Other.1.)The design pressure In this Evaluation Reports application relates to one particular EL5259 R28 AE 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259 underlayment system(over concrete deck) R28.odf for use under foam-on tile systems(where Created by Independent Third Party:Yes the underlayment forms part of the load- path).Refer to ER Section 5.6.4 for other systems,other deck types and associated maximum design pressures.2.)Refer to ER Section 5 for other limits of use. 9a Next Contact Us;;7601 Blair Stone Road.Tallahassee FL U999 phone•850-4$],824 The State of Florida Is an AAjM0 employer.Cooydaht 2007-2013 State of Flndd,),::privacy Statement::Accessibility Statement;t Refund stxtemeo� Under Florida law,email addresses are public records_Ifyou donor want your e-mail address released in response to a publio-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,Please contact 850.497.1395.*Pursuant to Section 455.275(i), Florida Statutes,effecdve October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the 9censee.However email addresses are pubic record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455,F.S.,please cildch re, Product Approval Accept= ®W®R Credit Card Safe li i i i . +i I - I NEMO etc. Certicate ofAuthorizatlon#32455 353 Christian Street,Unit#13 Oxford,CT 06478 lilt (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Polyglass USA,Inc. Evaluation Report P12060.02.09-R24 1111 West Newport Center Drive FL5259-1128 Deerfield Beach,FL 33442 Date of Issuance:02/24/2009 (954)233-1230 Revision 24:01/24/2018 I ' SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, F.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the a Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. (CONTINUED COMPLIANCE: This.Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility lot:ation(s). NEMO Ietc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. i This Evaluation Report consists of pages 1 through 14. Prepared by: Robert J.M.Nieminen,P.E. �'"" �=� `�'w= �`"��� The facsimile seal appearingwas authorized by Robert Nieminen, Florida Registration No.59266,Florida DCA ANF1983 �?;;"s�' �?`<<r;� P.E.on 01/24/2018.This does not serve as an electronically signed document' CERTIFICATION OF INDEPENDENCE: 1. NEMO Ietc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO eta Is not owned,operated or control led by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,A.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert N€eminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc.nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. I I i jONEMO etc. ROOFING COMPONENT EVALUATION: I. SCOPE: Product Category: Roofing Sub-Category: Und erlaym ent Compliance Statement: Roof Undedayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the a Edition(2017)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3A Wind Uplift UL 1897 2012 1507.2.3/1507.1.1 Physical Properties ASTM D226 2009 1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 2507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: I Entitv Examination Reference Date FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000 PRI(TST5878) Physical Properties PRIO1111 04/08/2002 PRI(TST 5878) Physical Properties PUSA-005-02-01 02/31/2002 i PRi(TST5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI(TST5878) Physical Properties PUSA-023-02-02 12/23/2002 PRI(TST5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI(TST5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI(TST5878) Physical Properties PUSA-028-02-02 07/13/2005 PRI(TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI(TST 5878) Physical Properties PUSA 035-02-01 09/29/2006 PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI(TST 5878) Physical Properties PUSA 061-02-02 01/28/2008 PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRi(TST5878) Physical Properties PUSA-093-02-01 04/14/2008 PRI(TST5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI(TST 2508) Physical Properties JX201-17A 04/01/2008 MTI(TST 2508) Physical Properties RX14E8A 01/29/2009 ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) Physical Properties 135110.04.07-1 04/11/2007 ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD(TST 6049) Physical Properties .P23450.08,09 08/13/2009 ERD(TST 6049) Wind Uplift P30540.11,09-R2 12/30/2009 ERD(TST 6049) Physical Properties P11030.11,09-1 11/30/2009 ERD(TST 6049) Wind Uplift P11030.11,09-2 11/30/2009 ERD(TSr 6049) Physical Properties P11030.11.09-3 11/30/2009 ERD(TST 6049) Physical Properties P33360.06,10 06/25/2010 ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011 NEMO ETC,LLC, Evaluation Report P12060.02.09-R24 Certificate o}AuMarimtion#324S5. 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments,(954)233-1230 Revision 24:01/24/2018 Page 2 of 14 ONEMO etc. Enti Examination Reference Date ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD(TST 6049) Physical Properties 13413390.08.12-2 08/07/2012 ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD(TST 6049) Wind Uplift P39680.03.13 03/D4/2013 ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 ERD(TST 6049) Physical Properties P4S270.05.14 05/12/201.4 ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD(TST 6049) Physical Properties 6020.09,14-2 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.143 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015 ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015 ERD(TST 6049) Physical Properties P44360.10.14-111 05/28/2015 ERD(TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2025 ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 ERD(TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016 ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 ERD(TST 6049) Physical Properties PLYG-SC33040.12.16 12/27/2016 ERD(TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017 ERD(TST 6049) Physical Properties PLYG-SC12115.08.17 09/08/2017 )CC-ES(EVL 2396) 1BC Compliance ESR-1697 12/01/2014 Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/28/2009 Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.3.0/05/2018 4. PRODUCT DiiscwpT1ON: 4X MecitanicallyFasfenetl.Unde�laXnierits i 4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen basesheet. 4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet. 4.1.3 Polyglass 62 Base Is a fiberglass-reinforced,asphaltic base sheet. I4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet. 4:2. :Se'if=Adh0 ingUnderl'ayirie!i s: 4.2.1 Polystick MTS or Polystick MTS PWS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass' fiber reinforced,surfaced with polyo(efinic film surface;meets FRSA/TRI April 2012. 4.2:2 Polystick(R-Xe is-4-nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an - aggregate surface;meets ASTM D1970. 4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a polyester fabric surface;meets ASTM D1970 and FRSA/TRl April 2012. NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 EDITION 12017)PBC NON-HVHZ EVALUATION 1:1.5259-1128 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 I Page 3 of 14 I I NEnno)etc. 4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced,with a granular surface;meets FRSA/TRI April 2012. ! 4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface;meets ASTM D1970 and FRSA/TRI April 2012. 4.2.6 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA APP Cap Sheet(FR) are polyester . reinforced,APP modified bitumen cap sheets;meet FRSA/TRI April 2012. 4.2.7 Polystick Dual Pro'" is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyesterfabric surface;meets ASTM D1970. 4.2.8 Polystick Tile ProTM' is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970 and FRSA/MI April 2012. 4.2.9 Polystick MU-X is a nominal 54-mil thick,dual-layer rubberized asphalt waterproofing membrane, fiberglass I reinforced,with a polypropylene film Surface; meets AC188 and physical requirements of ASTM D1970(See Section 5,8). Mechanically Fastened°.antiJot=Bonded Urideflayril 4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand-surfaced SBS i modified bitumen back-side and granule-surfaced APP modified bitumen top-side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M)in the "Single Ply System"from FRSA/TRI April 2012 (04-12)beneath mechanically fastened file roof systems or Hot Asphalt applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems. 4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D6164. Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to"Mineral Surface Roll Roofing" (ASTM D6380, Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet"in the`Two Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is fdr use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied"Cap Sheet'in the"Two Ply System"from FRSA/TRI April 2012 (0442)beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat ! Applied "Cap Sheet" in the`Two Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. i 5. !IMITATIONS: 5.1 This is a building code evaluation. Neither NEW Ietc. nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings ofthis product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product Is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.. NEMO ETC,U.C. Eva[uatlon Report P32050.02.09-1124 j Cerhfxate ofAuthorizatlon#3Z455 6m EDITION(2017)FBC NON-HVHZ EVAWAMQN FL5259-R28 Polyglass Roof Onderlaymeots,(954)233-1230 Revision 24:01/24/2018 Page 4 of 24 I � J . f • � J ONEMOjetc. j5.5 Allowable Roof Covers: .'CABLIc.l:'<ROOF:COVEBQPi 66. Underlayment Asphalt Shingles Nail-On Tile Foam-On 711e Metal Wood Shakes &Shingles Slate Elastobase Yes Yes Yes Yes Yes Yes (Base Sheet In2-plysWem) lease Sheet in 2-ply system) Elastobase P Yes Yes Yes Yes Yes Yes (Base Sheet in 2-ply system) (ease Sheet in 2-ply system) Polyglass G2 Base No Yes Yes No No No (Base Sheet In 2-ply system) (Base Sheet In 2-plysystem) Polyglass APP Base No Yes Yes No No No (Base Sheet In 2-ply system) (awe Sheet In 2-ply system) Polystick MTS or NITS PLUS Yes Yes No Yes Yes Yes Polyst)ck IR-Xe Yes No No No Yes Yes PolystickTUP No Yes Yes(See 5.5.1) No No No Polystick TU Plus Yes Yes Yes(See 5.5.1) Yes Yes Yes PoiystfckTUMax No Yes' Yes(See 5.5.1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Yes Yes Yes(See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes ElastaRex 56 G Yes Yes Yes(See 5.5.1) No Yes Yes Elastoflex 56 G FR Yes Yes No No Yes Yes Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G Yes Yes Yes(See 5.5.1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes(See 5.5.1) No Yes Yes Mule-Hide SA-APP Cap Sheet orSA-APP Cap Sheet(FR) yes Yes Yes(See 5S.1) No Yes Yes 5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underiayment combinations. TABi 1 1A:ALLOWA�LETILE ADIESIVE UNDERIAI(MI7QT;COIgIBINAT10N5 "' Adhesive Florida Product Approval Underlayments DAP Foam Touch'n Seal StormBond Roof Tile Adhesive FL14506 Polystick TU Plus,Polystick TU Max DowTiileBond— FL22525 Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro I Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro, ICP Adhesives Polyset°AH-160 FL6332 Elastaflex G TU,Elastoflex S6 G,Polyflex G,Polyflex:SAP,Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) Polystick TU P,Polystick TU Pius,Polystick TU Max,Polystick Tile Pro, ICP Adhesives Polyset°RTA-1 FL6276 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Palyflex SAP,Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA APP Cap Sheet(FR) I 1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida ProductApprova/far Overturning Moment Resistance Performance. II NEMO ETc,I.I.C. Evaluation Report P32060.02.09-R24 Cert7Rcate ofAuthar&aMm#32455 6Te EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlaymerts;(954)2331230 Revision 24:01/24/2018 Page 5 of 14 I 1 ONEMO.etc. 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Polystick(all variations),Dual Pro,Tile Pro,Polyflex SAP or SAP FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)self-adhered to: ➢ New untreated plywood;ASTM D41 primed new untreated plywood;Existing plywood;ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine, ASTM D41 primed Southern.Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note;Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should he cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch-applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond-to-Insulation: Polystick(all variations),Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)self-adhered to; ➢ ASTM C1289, Type 11, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard;Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. I Polyflex G or Palyflex G FR torch-applied to: ➢ ASTM D41 primed structural concrete;Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on file systems,insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlaymentsystem in accordance with FBCSection 1504.3.1. 5.6.3 Bond to Mechanically Attached Base Laver: Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)Dual Pro or j Tile Pro self-adhered to: ➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P or Mule-Hide Nail Base. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226,Type I or II felt,Elastobase;Elastobase P,Mule-Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch-applied to: ➢ Elastobase;Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04-12),Appendix A,Table 1,or as listed in Section 5.6.4 herein,or as tested in accordance with FBC Section 1504.3.1. I ' I i NEMO ETC,U.C. Evaluation Report P12060.02.09-R24 Certificate ofAuthorization#32455 6TM EDITION 12017)FBC NON-HVHZ EVALUA-noN FL5259•R28 Polyglass Roof Underlayments;(954)233-2230 Revlslon 24:01/24/2018 + Page 6 of 14 i I i i i ONEMOletc. i 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer to FRSA/TRI April 2012(04- 12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-AP P Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #2 Maximum Design Pressure=-97.5 psf: Deck: Min.15/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure=-105 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x IN"ring shank nails through 32 ga.,1-5/8"diametertin caps spaced 12-inch o.c. #4 Maximum Design Pressure=-135 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #5 Maximum Design Pressure=-315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Tile Pro,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #6 Maximum Design Pressure=-622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #7 Maximum Design Pressure=-30.0 psf*: Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga,x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certhcate ofAuthodzation#32455 67H EDITION(2017)FBC NON-HVH2 EVALUATION FL5259-R28 Potygiaw Roof Underlayments,(954)233-2230 Revision 24:01/24/2018 Page 7 of 14 NNEMO etc. #8 Maximum Design Pressure=-37.5 psf*: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 34nch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #9 Maximum Design Pressure=-37.5 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having.lurisdiction. Base Sheet: One(1)ortwo(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hat asphalt. #10 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)layer ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-ad hering underlayment only)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt. #11 Maximum Design Pressure=-45 psf*: Deck: Min.19/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. . Base Sheet: Two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt #12 Maximum Design Pressure=-45 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.attwo(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #13 Maximum Design Pressure=-52.5 psi Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.atthe 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #14 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c,at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certificate afAutharization#32455 6TM EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 8 of 14 1 ONEMOJeft. #15 Maximum Design Pressure=-52.5 Dsf: Deck: Min.35/32-Inch plywood to meet project requirements to satisfactlon of Authority Having jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-Inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #16 Maximum Design Pressure=-60 Dsf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch ox.at the 4-inch wide side laps and 8-Inch ox.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #17 Maximum Design Pressure=-60 Dsf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c.at the 4-Inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. + Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #18 Maximum Design Pressure=-67 5 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base{requires use of torch-applied underlayment) Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch mc-at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch- applied. #19 Maximum Design Pressure=-75 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied Underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c.atthe 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch- applied. #20 Maximum Design Pressure=-90 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXI(Cap Fasteners Spacing: 64nch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #21 Maximum Design Pressure=-90 nsf: Deck: Min,25/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.atthe 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #22 Maximum Design Pressure=-90 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt NEMO ETC,I.I.C. Evaluation Report P12060.02.09-1124 Certificate ofAutharizoVon N32455 6r EDITION(2017)P$C NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof URderlayments;(954)233-1230 Revision 24:01/24/2018 Page 9 of 14 i i ONEMOletc. #23 Maximum Design Pressure=-90 psi Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underloyment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch- applied. #24 Maximum Design Pressure=-97.5 asf: Deck: Min.19/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 44nch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #25 Maximum Design Pressure=-105 psi: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-a pplied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-Inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or ElastaflexS6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #26 Maximum Design Pressure=-112.5 psi Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c,at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin-caps Base Ply: Polystick MTS or Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #27 Maximum Design Pressure=-120 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Rocfgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #28 Maximum Design Pressure=-120 asf Deck: Min.15/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing. 6-inch o.c.at the 4-inch wide side laps and 6-Inch o.c.at five(5)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.1 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on file systems carry a Maximum Design Pressure of-45 psf. i NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 C&Wcate ofAudwrization#32455 6�v EDITION(2017)FBC NON-HVHZ EVALUATION Ft5259-R28 j Polyglass Roof Underlayments,(954)233-1230 Revision 24:01/24/2018 Page 10 of 14 l OMEMO I etc. 5.6.4.2, For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case,Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk's carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016)for Zone 2/3 enhancements. i5.7 Exposure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe or Polystick MU X shall not be left exposed for longer than 90-days after installation. Polystick MTS, MTS PLUS,TU P,TU Plus,TU Max, Dual Pro,Tile Pro or Elastoflex G TU shall not be left exposed for longer than 180-days after installation. Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30 days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. f 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller,as set forth in Section 4.3,Note 1 ofASTM D7970-15,should be established as to slip resistance. 5.9 Tile Slipoatte Limitations(FRSA/TRI April 2012(04-12))• When loading roof tiles on the•underlayment in direct-deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. �XABLEZ::TILE.StiPBAC,E+1:IM17A710NSF.Ori;DiBE6TrD_EGKTILE�NSTALI9TIONS. _ Underlayment Tile Profile Staging Method Maximum Slopet Elastoflex G TU Flat 10-tile stack 7:12 Lugged 8-tile stack(6 over 2) 6:12 Elastoflex S6 G or S6 G FR Flat or Lugged &tile stack(4 over 2) 4:12 Polystick MTS or MTS PLUS Flat 6-tile stack(4 over 2) 5:12 Lugged 6-tile stack(4 over 2) 4:12 Polystick Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12 Flat 6-tile stack(4 over 2)or 10-tile stack 7:12 Polystick TU Max Lugged 6-tile stack(4 over 2) 7:22 Lugged 10-tile stack 6.12 PolystickTU P Flat 6-tile stack(4 over 2) 6:12 Lugged 6-tile stack(4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6-tile stack(4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack.(4 over 2) 4:12 NEMO ETC,I.I.C. Evaluatlon Report P12060.02.09-R24 Certificate ofAuthorizWon#32455 6r"EDITION(2027)FBC NON-HVHZ EVALUATION FL5259-R28 Poiyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 11 of 14 I ONEMOJetc. 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). e Elastobase P of Mule=Hide 6.3 Elastobas 6.3.1 Non-Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226,Type 11 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase,Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick,Polyflex SAP,Polyflex SA P FR, Mule-Hide SA APP Cap Sheet or SA-APP Cap Sheet (FR), self-adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are those associated with the top-layer underlayment,as set forth in Table 1 6.3.2 Tile Applications: Elastobase,Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the"fwo Ply System"from FRSA/TRI April 2012(04-12). Reference is made to Table 1 and Section S.6.4 herein,coupled with FRSA/TRI April 2012(04-12)installation Manual. 6.4. Pol ick• ."i T'PLUS-1R= e .LU;P TU`P.IuS TU Max Daa1<P o%Tire,Piro.d.Vi =1(or:Poljjfleic SAP,•;PolyfleX•S"F } :S: Mule-Hide SA:J4PP'6a 'Shee%or'.iVl(ule;TiideSA:APPCa e, 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970(except Polystick TU P)underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers: All self-adhering materials,with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule- Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter metal disk or Simplex-type metal cap nail,at a minimum rate of 12"o.c. Pollystick TU Plus should be back- nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back-nailed. All seal-lap seams (selvage laps) must be s firmly rolled with a minimum 28 lb. hand F roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). J View of Ovelap Seam of Dual Pro and Tile Pro All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. 1 Polystick TU Plus,Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys, or exposed roof to wall details NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certificate ofAethoraaVan#32455 6 EDITION(2017)FBC NON44VHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments,(934)233-1230 Revision 24:01/24/2018 Page 12 of 14 I I ONEMOletc. Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass P13500 Modified Cement to the area in need of repair,followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled In place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-ib weighted-roller or,on steep slopes,use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches,laps(mina 28 lb roller)or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 • Tile Applications(not allowed for Polystick Dual Pro IR Xe or Egh%ick MU Xl Reference is made to FRSA/TRI April 20IZ (04-12) installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened file roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s),Base Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1. For adhesive-set tile applications,refer to Section 5.6.4 herein. 6.4.4 . Two(2)Ply Underlayment Systems: Polystick MTS or MTS PLUS followed by Polystick MTS,MTS PLUS,TU P,TU Plus,TU Max,Tile Pro,MU-X or Polyflex SAP is allowable for use under mechanicallv attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired. Polystick MTS or MTS PLUS followed by Polystick TU P,TU Plus,TU Max,Tile Pro or Polyflex SAP is allowable for use under foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. st ft `G1'll'' i" e>r .G•o' 1 6.5.1•. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G PR shall be installed in with current Polyglass published installation requirements. For use in file applications: ✓ Elastoflex G TU is for use as an alternate to"Mineral Surface Roll Roofing'(ASTM D6380,Class M)in the"Single Ply System"from FRSA/TRI April 2022(04-12)beneath mechanically fastened the roof systems or the Hot Asphalt applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered the roof systems. ✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(AS M1 D6380,Class M)in the"Single Ply system"from FRSA/TRi April 2012 (04-12)beneath mechanically fastened tile roof systems or the Hot Asphalt applied"Cap Sheet"in the'Two Ply System"from FRSA/TRI April 2022(04-12)beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to"Mineral Surface Roll Roofing'(ASTM D6380,Class M)in the"Single Ply System"from FRSA/TRi April 2012(04-12)beneath mechanically fastened the roof systems or the Hot Asphalt applied"Cap Sheet"in the`Two Ply System"from FRSA/TRi April 2012(04-12)beneath mechanically fastened tile roof systems. 6.5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt=applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. :;,•,: :: .-.:n .;.>`>' sitar 6.6 ex:G:or•Po ex G-:Fife: -'-' '_''' Y� hid - 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use as an alternate to the Heat Applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered the roof systems(Base Sheet Limited per 5.6.3). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet"In the"rwo Ply System"from FRSA/TRI April 2012(04-22)beneath mechanically fastened the roof systems(Base Sheet Limited per 5,6.3). NEMO ETC,LLC. Evaluation Report P12060.02.09•R24 Certffkate ofAuthorizath:n#32455 6T"EDITION(2027)F13C NON-1iVH2 EVALUATIoN FL5259-R28 Polyglass Roof Underiayments;(9641233-1Z30 Revision 24:01/24/2018 Page 13 of 14 ONEMOjetc. 6.6.2 Polyflex G or Polyflex G FR shall be fully torch-applied to the substrates noted in Section B.G. Side laps shall be minimum 3-inch and end-laps minimum 6-Inch wide, off-set minimum 3 feet from course to course. Side and end laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Staeina: 6.7.1 Tile shall be loaded and staged In a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein,and Polyglass published requirements for the staging. 6.7.2 Battens and/or Counter-battens,as required by the the manufacturer and FRSA/TRI April 2012(04-12)must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail- boards,to prevent file sliding and/or damage to the underlayment during the loading process. 6.7.3 Polyglass specifies the minimum cure time after Installation of self-adhering membranes and before loading of roofing tiles is forty-eight(48)hours. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C.61620-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. j :Plant i So'eeification< _ :'.k; ], Fernley,NV,Hazleton,PA&Winter Haven,FL a ASTM D1970 Polystick MU-X Hazleton,PA M-D 13-0004. Elastoflex G TU ASTM D1970 Polystick IR-Xe Hazleton,PA&Winter Haven,FL ASTM D1970&FRSA/TRI April 2012 Polystick TU Plus ASTM D1970&FRSA/TRI April 2012 PolystickTU Max Tuscaloosa,AL ASTM D4601,Type II Polyglass G2 Base ASTM D226(physicals) Elastobase,Elastobase P ASTM D6509 Polyglass APP Base FRSA/rRI April 2012 Polystick MTS,Polystick MTS PLUS FRSA/TRI April 2012 Polystick TU P Winter Haven,Fl. FRSA/TRI Aprll 2012 Polyflex SAP,Polyflex SA P FR ASTM D1970 Polystick Dual Pro ASTM D1970&FRSA/TRI April 2012 Polystick Tile Pro ASTM D6164 Elastoflex S6,Elastoflex S6 G FR ASTM D6222 Polyflex G,Polyflex G FR 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com END OF EVAWATION REPORT- NEMO ETC,LLC. Evaluation Report P32060.02.09-R24 j Certificate afAutharizatian#32455 Ern EDITION(2017)FBC NON-HVHZ EVALUATION F1.5259-1128 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 14 of 14 I