Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProduct Approval (3) MIAMI-DADE 1VIIAMI-DADE COUNTY
o PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 3 3 1 75-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economv
Sun-Tek Manufacturing,Inc.
10303 General Drive
Orlando,FL 32824
SCOPE:
j This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ)
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in .
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane
Zone of the Florida Building Code.
DESCRIPTION: ISFG Skylight System
APPROVAL DOCUMENT: Drawing No. STI-00000298,titled"ISFG", sheet 1 &2 of 2,prepared by Sun-Tek
Manufacturing,Inc., dated August 07,2007, signed and sealed by James D. Wells, Jr.,P.E., on October 06,2017,
bearing the Miami-Dade County Product Control Renewal stamp with the Notice of Acceptance number and the
expiration date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series and the following statement: "Miami-Dade County Product Control Approved", unless otherwise
i
noted herein.
j .RENEWAL of this NOA shall be considered after a.renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA#17-1023.22 and consists of this page 1, evidence submitted pages E-1, E-2, E-3 &E-4,
j as well as approval document mentioned above.
The submitted documentation was reviewed by Helmy A.Makar,P.E.,M.S.
/J if NOA No.18-0716.03
KAMI•DADE COUNTY (✓ Expiration Date: 10/31/2023
�I f o ) f Approval Date: 11/01/2018
/ / Page 1
J�
I
Sun-Tek Manufacturing,Inc.
I
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#07-0425.04
A. DRAWINGS
1. Drawing No. STI-00000298-SHTIISHT2, titled "ISFG", sheet I & 2 of 2, prepared
by Sun-Tek Manufacturing, Inc, dated 06104107 with last revision dated 08107107,
isigned and sealed by James D. Wells, Jr., P.E.
B. TESTS (submitted under NOA# 02-0618.06)
1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per
PA 203 and Uniform Static Air Pressure Test per PA 202 of"Insulated Glass Skylight
with Polycarbonate Inner Liner" prepared by National Certified Testing
I Laboratories, Report No. 210-2760-1, 2 & 3, dated 01122102, signed and sealed by B.
Portnoy, P.E.
C. CALCULATIONS
1. Anchor Calculations for attachment of skylight to curbing and curbing to decking,
dated 08113107, signed and sealed by James D. Wells, Jr., P.E.
jD. MATERIAL CERTIFICATIONS (submitted under NOA#02-0618.06)
1. Test report on Rate of Burning per ASTMD635 of Geon 87416 White 141
I Exterior, 0.137 inch,prepared by Commercial Testing Company, Report No. 01-
11293, dated 11129101, signed by J. Jackson.
2. Test report on Self Ignition Temperature per ASTMD1929 of Geon 87416 White
141 Exterior,prepared by Commercial Testing Company, Report No. 01-11292,
dated 11129101, signed by J. Jackson.
E. STATEMENTS (submitted under NOA#02-0618.06)
1. Code compliance letter issued by Product Technology Corporation. on 09/27102,
signed and sealed by R. J. Quiroga P.E.
F. OTHER
1. NOA renewal request letter issued by Sun-Tek Manufacturing, Inc., dated 08116107,
James Feudner.
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#11-0601.02
A. DRAWINGS
1. Drawing No. STI-00000298-SHTIISHT2, titled "ISFG", sheet 1 & 2 of 2, prepared
by Sun-Tek Manufacturing, Inc, dated August 07, 2007, last revision #A dated
October 14, 2011, signed and sealed by James D. Wells, Jr., P.E.
cl>fle'liny A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No.18-0716.03
Expiration Date: 10/31/2023
Approval Date: 11/01/2018
E-1
l
I
1
i
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS
1. Test Addendum for Test Report NCTL 210-2760-1, prepared by national Certified
Testing Laboratories, dated October 17, 2011, certifying the interlayer thickness,
signed by Mark Bennett, Manager of Testing Services.
C. CALCULATIONS
1. None.
D., QUALITY ASSURANCE
1. By Miami-Dade County Department of Permitting, Environment, and Regulatory
Affairs (PERA).
I E. MATERIAL CERTIFICATIONS
i
1. None.
3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#12-1011.15
A, DRAWINGS
1. Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek
i Manufacturing, Inc, dated August 07, 2007, last revision #A dated May 03, 2012,
signed and sealed by James D. Wells, Jr., P.E.
B. TESTS
i
1. None.
{ C. CALCULATIONS
1. None.
i
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1 1. None.
F. OTHERS
1. A compliance letter, issued by J&L Wells Consulting LLC, dated 0412512012, certify
compliance with FBC 2010 edition, signed&sealed by James D. Wells, Jr., P.E.
2. Verification testing to be performed per letter from National Certified Testing
Laboratories, dated September 18, 2012 signed by Christopher Bennett.
Helmp A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 18-0716.03
Expiration Date: 10/31/2023
Approval Date: 11/01/2018
E-2
Sun-Tek Manufacturine,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
.4. ' EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL# 13-1028.05
A. DRAWINGS
1. Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, last revision #A dated August 15, 2013,
signed and sealed by James D. Wells, Jr., P.E., on February 07, 2014.
I
B. TESTS
1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per
PA 203 and Uniform Static Air Pressure Test per PA 202 of"Insulated Glass Skylight
with Polycarbonate Inner Liner" prepared by National Certified Testing
Laboratories, Report No. 210-3915-01, dated 0812712013, signed and sealed by
Gerard Ferrara, P.E.
C. CALCULATIONS
1. Anchor Calculations for attachment of skylight ?Model ISFG to Decking, dated
1010312013, signed and sealed by James D. Wells, Jr., P.E.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. Bill of Material and Components Die Drawings.
i
5. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL# 15-0513.10
A. DRAWINGS
1. Drawing No. STI-00000298, titled "ISFG", sheet I & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, last revision 4A dated May 04, 2015,
signed and sealed by James D. Wells, Jr., P.E., on May 04, 2015.
I
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
Otle-lmy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 18-0716.03
Expiration Date: 10/31/2023
Approval Date: 11/01/2018
E-3
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
6. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#17-1023.22
A. DRAWINGS
1. Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, signed and sealed by James D. Wells,
Jr., P.E., on October 06, 2018.
B. TESTS
1. None.
C.. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami Dade County Department of Regulatory and Economic Resources.
f
E: MATERIAL CERTIFICATIONS
1. None.
7. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. None.
i
B. TESTS
1. None.
I
C.' CALCULATIONS
1. None.
D. QUALITY ASSURANCE
{ 1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. OTHERS
1. A compliance letter, prepared by J&L Wells Consulting LLQ dated June 20, 2018,
certify compliance with FBC 2017 edition, signed & sealed by James D. Wells, Jr.,
P.E.
C-Relmy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No.18-0716.03
Expiration Date: 10/31/1023
Approval Date: 11/01/2018
E-4
I
i
I
PART NAME:ISFG SKYLIGHT ASSEMBLY FILE NAME:Z1DWGlDWuV\CAD 2000 DRAWINGSIDADE COUNTY ISFG STI-00000298 SHT1 SHEET 1 QF 2 pWS3_NO.STI-00000298 5H"fi
STI-215 DECO COVER 0.075 6063 T6 ALUM — 17132"GLASS BITE
�I 115"OUTBOARD DSB TEMPERED STI-214 DECO RING MITERED AIJD
SILICONE BEDDING(CONTINUOUS) I` �-118"INBOARD GLASS DSB TEMPERED WRAP AROUND 0.050 6063 T6 ALUM.
STI-6 GLASS GASKET EPOM - _
(CONTINUOUS) INSULATED AIR SPACE
- STI-205 CMG FRAME 0.060 MITERED
ARGON GAS FILLED AND WELDED 60M T6 ALUM.
STI-401 WOOD LINER 1.160.935' —�
(CONTINUOUS) sMGGLESPAGLR(0.6 5)
#8-32 PHILLIPS PAN HD SCREW AND HEX NUT
7 PER LONG SIDE 7 PER SHORT SIDE -- '77 POLVCARuoNArE SHEET � \
�—SILICONE SEAL TOP AND BOTTOM
PALRAM PALSUN (CONTINUOUS)
U_a BUTYL 3 RINGS OF SEALANT STI-300 PVC LINER STI-207 HSF SUB-FRAME MITERED AND
0:1BENEATH FLANGE(CONTINUOUS) GEON 87416 WHITE WELDED 0,075 6063 T6 ALUM.
z 00 AROUND PERIMETER OF FLANGE 141 EXTERIOR ,-
w (CONTINUOUS)AND ON TOP OF EACH a<ti ts:e Fl:as:se
z O FLANGE SCREW
w AIR SPACE OR sazhdcR:?
DADE COUNTY APPROVED Z� #8 X 1"PHILLIPS PAN HEAD
EXPANDED POLYSTYRENE INSULATION
In SHINGLES 8x$pl2V+ 011A ,;w )O D SCREW, (9)PER SIDE
(SEE NOTE 1) Tr � I�T
,,>t�i is�rsaar>
ROOF DECK mina"thick
ea
DESIGN PRESSURE RATING+I-80 PSF.�
LARGE MISSILE IMPACT RESISTANCE 1
Engineer of Record
James D.Wells,Jf.,P.E. VOTE: ��' ®" :-f
Professional Engineer No.53616 I A sb� ,�oRj0t- o;
(1)ALL ROOFING DETAILS SHALL COMPLY WITH �"
"HAPTER 15 OF
DISTANCEHEFLORiDA
BUILDING CODE
F j edition
(2)4
J&L Wells Consulting LLCFROM A P TO ROOF
1453 Arbitus Circle SURFACE IS FOR SHINGLE OR B.U.R.WITHOUT _E ��., ,•.y
Oviedo,FI.32765 INSULATION.FOR INSULATION AND TILE ROOF ADD j�
FILE HEIGHT AND INSULATION THICKNESS TO 4". �TL e,NP�s,;; Nit
(407)495-5489 (3)ANCHORS TO BE MADE FROM NON-CORROSIVE MATERIAL 2
'\
Certificate of Authorization
Lra; -} �
COMPATIBLE WITH ALUMINUM. RAFTER OR TRUSS f
No.27162 (4)NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED.
(5)TESTED TO TAS 201,TAS 202 AND TAS 203. _' - _ ic'-0A r
�T n rat ;(. �si.�.,'t��
REVISION' A REVISION' PRODUCT NAME: ISF� SUN—TLK MANUF/�.41,UA�.tNIG, INC.
REVISION MADE 01 SHY 20F 2
SY: ©SQ DATE: uywm7 ev. A,4 �ArE• Sr15r?.o%s DRAWN BY: JWF DATE:08115/201 DWG,NO.STI-0000Q298--SHT1 REV. A 10303 GENERAL DRIVE ORLANDO.FL 32824
PART NAME:ISFG SKYLIGHT PLAN VIEW FILE NAME:Z:\DWG\DWG%CAD 2000 DRAWINGS\DADS COUNTY ISFG STI-00000298-SHT2 SHEET 2 OF 2 DWG.NO.STI-00000298-SHT2
t1yb4.b STI-214 DECO RING MITEREOANDWRAPPED
W64 '.."Ri
tip t0 tip AROUND0.050 6063T6ALUM4.000 5581254•QOD—°" - C) SILICONE BEDDING(CONTINUOUS) -STI-215 DECO COMER0.0756063 T6 ALUM
5.8 25 5 15 •�--'+^' v STI.6GLASSGASKETEPDIA- OUT©OARDOSBTEMPERED
(CONTINUOUS)STI.401 WOOD LINERSWIGGLESPACER(0625")
(CONTINUOUS)
- SULATED AI 5PACU.:• I STI-205 CMG FRAME 0.060 h11TER Ep AND—� ARGON GAS FILLED
, --+- 5•$12�j WELDED CORNERS 606316ALUM ��-
'£ I n N8-32 X.t"PHILLIPS PAN HD SCREW
1 >h '� �; 7* II I AND HEX NUT(7)PER SIDE INBOARD GIAS$DSO TEMPERED
c = FASTENERS SKYLIGHT TOM t ONTiNUNE SEAL US) `-- —
=u TO DECK 118 X 1"(9)PER SIDE n AND BOTTOM(coNiINUOus7
w 'r• n STI-207 HSF SUB-FRAME MITERED .1n POLYrnRea�ATESHECT
. L'[ O PALRAM PALSIN
F- �, AND WELDED CORNERS 0.076
H I- � 6063 T6 ALUM-
. AIR SPACE OR
I ISFG 4949 I I n �0 3 RINGS OF BUTYL SEALANT
iv - - - O .* n W BENEATH FLANGE(CONTINUOUS) �, dDryAgDuEt�CODU APPROVED
I I r r` rD Z a AROUND PERIMETER OF FLANGE tl 4 6 d d 6 N
(CONTINUOUS)AND ON TOP OF EACH °}b �r
, SYtv}E RICAL n O FLANGE SCREW H LSD`
o `v`n SHINGLES
col nLo
(SEE NOTE 11 •'°b'•e1 ,��,'+:% ,,,°gp'_'d°,,n°'
Ica 53616 �.
116 X 1"PHILPS PA ! ddaad9
ire n SCREW 9 P "'�i = U
sm r' '`::t FASTENERS SUB-FRAME TO FRAME ( ) ER SIDE / �r t
r,Ct 2"min.protrusion p (�
a Z:
;; y'fit �?, -'"^mot•',. h ROOF DECK ri"min thickness r„ '4,, ° �� i<a®"+•4,�
(' •' ti^ vx�. �� +aS
,ktXt' •Cxd a°'..� - -- -- -- _ I RAFTERORTRUSS i"�� 4s`J•, r t ,.'li'•�'4,
FASTENER SCHEDULE SKYLIGHT TO @J ME TO FRAME
q"MIIVINUM LIP TO A 08 X 1"PAN HEAD
O ROOF SURFACE SCREWS 178.32 X 314"WITH HEX NUTS
d {? PER PER PER PER
DESIGN PRESSURE RATING+/-80 PSF. O tip to up MODEL
CT RESISTANCE cv LONG SIDE SHORT SIDE LONG SIDE SHORT SIDE
LARGE MISSILE IMPA
Engineer of Record 5a5645 4949 9 9 7 7
NOTE: James D.Wells,Jr.,P.E. 51.5.51.6 4646 6 —" 8 _--i-- 7
Professional Engineer No.53616 3ns,a.5 3349 9 6 7 5
(1)ALL ROOFING DETAILS SHALL COMPLY WITH 3e.sH395 3333 6_ 6 _ 5 5
CHAPTER 15 OF THE FLORIDA BUILDING CODE 2017 edition 35.5[51s 3046 _8 6 7 5
(2)4"MINIMUM DISTANCE FROM ANGLE LIP TO ROOF 35.5.35.5 3030 1 6 6 5 2533 9 � 7 4
-_ 5
SURFACE IS FOR SHINGLE OR B.U.R. D.s[3e.5.R.V ITHOUT AL Wells Consulting LLC 30.5.a.s 2.5_ 5 4
INSULATION.FOR(NSULATION AND TILE ROOF ADD 1453 Arbitus Circle 3D.5[39.5 252.5 5 6 4 4
TILE HEIGHT AND INSULATION THICKNESS TO 4". Oviedo, Fl. 32765 276[61.5 2J.46 8 - 5 7 4(3)ANCHORS TO BE MADE FROM NON-CORROSIVE MATERIAL (407)496-5489 ii.9a55- z23n 3 5 5 _ _ n
COMPATIBLE WITH ALUMINUM. zis.2rs 2222 6 5 _ _ 4
(4)NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED. Certificate of Authorization itsQ95 nas 4 7 3
(5)TESTED TO TAS 201,TAS 202 AND TAS 203. No.27162 3Z5[395 1733 __ 6 a _ 5 3
l5s<st.c 1446 B _ 4 7 3
tes[3,s �^1i43T0 r6 MANUFACTURING,
j��j4� p 5
REVISION REVISION: PRODUCT NAME: ISFG SUN (�, K MANUFACTURING, INC,
6Y Jvff DATE'. oBnDns F. DAYS— DRAWN BY. 1V1rr DATE: 1D/141201 DWG.NO.STI-OOOOD298-SHT2 REV. . A 103D3GENERALDRIVE ORLAND0,FL32624