HomeMy WebLinkAboutProduct Approval 3
BCiS Home Log In i User Registration Hot Topics € Submit Surcharge I Stats&Facts Publications i FBC Stag BCIS Site Map Unks i Search
€ Product Approval
r - USER:Public User
Product ApMrva[Menu>Product or Aoalicatibn Search>Apphcatian Us >Application Detail
ONYt
x„ FL. FL17443-R1
Application Type Revision
Code Version 2017
Application Status Approved
i
Comments
Archived
Product Manufacturer I A TAYLOR ROOFING
Address/Phone/Email 302 Melton Drive
FT PIERCE,FL 34982
(772)466-4040
kyiewhite228@aoi.com
Authorized Signature Kyle Taylor File Copy
kylewhite228@aol.com A*AW)�&3SI
Technical Representative �Address/Phone/Email REVIEWED BODE COMPLIANCE
OR
Quality Assurance Representative ��a � CIE
� ��U ��
Address/Phone/Email
i Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect,Name who developed the Locke Bowden
Evaluation Report
Florida License PE-49704
Quality Assurance Entity PRI Construction Materials Technologies,LLC
Quality Assurance Contract Expiration Date 01/23/2023
Validated'By Zachary R.Priest,P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL17442 R1 COI FL 17443 1 A Taylor 2017 Code Evai Report with Details
RSSS.pgf
Referenced Standard and Year(ar"Standard) Standard Year
TAS 125 2003
UL 1897
� 2012
UL580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method i Option D
Date Submitted 01/24/2018
Date Validated 02/14/2018
Date Pending FBC Approval 02/17/2018
Date Approved 04/10/2018
Summary of Products
�. ----------
FL# Model,Number or Name ;`Description
._... --..v_�._ _._ ......
�435 V Crimp 26GA 1/2"rib height over 15/32"APA plywood
f.Use `Installation Instructions
Approved for use in HVHZ:No FL17443 Ri II FL 17443 3 A Taylor 2017 Code Eval Repo
Approved for use,outside HVHZ:Yes wi h Details RSSS.}
Impact Resistant:N/A Verified By: Locke Bowden,P.E.49704
j Design:Pressure: +N/A/-129.25 Created by Independent Third Party:Yes
Other:-129.25 @ 6"o.c.-69.25 @16"o.c.margin of safety Evaluation.Reports
:2;1 with 24"max.coverage install per manufacturers detail. EL I7443 RI AE EL 17443 3 A Tayigr 0(7val ReRoLt
j Not for use.in HVHZ. with Details RSSS.pdf
Created by Independent Third Party:Yes
1 17443.2 VICTORIAN CRIMP SHINGLE 26GA 1/2"RIB-PANELS LOCK INTO PREVIOUS PANELS,OVER
CDX/APA 15/32 PLYWOOD
Limits of.Use Installation Instructions
Approved for use in HVHZ:No 171_17443 R3 II FL 174431 A Taylor 2017 Code Eval Repor
Approved.for use outside HVHZ:Yes with Details RSSS,p.,Lif
Impact Resistant:N/A Verified By: Locke Bowden,P.E.49704
Design Pressure +N/A/-105 Created by Independent Third Party:Yes
Other:-105PSF margin of safety 2:1.Install per Evaluation Reports.
manufacturer's details and in compliance with FBC 2017 6th !!!. FL17443 RI AE FL 17443 1 A Taylor 2017 Code Eyal Reggrt
ed. Not for use in HVHZ. with Details 9SSS.pdf
Created by Independent Third Party:Yes
�ae!r '�exH
Contact Us::2601 Blair Stone Road.Tallahassee EL 32399 Phoner 850-487-1824
The.State of Florida is an AAIEEO employer.,fgQynght 2007.2013 State of Fiori ::p iv Statement Accessibility Statemee*::$� r acv Refund Statement
Under Florida law,email addresses are public records.if you do not want your e-mail address released in response to a pub lic-recotds request,do not send electronic
mail to this entity.instead,contact the office by phone or by traditional mail,if you have anyquestions,please contact.856.487.1395,*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter455,F.S.must provide the Department with an email address if they have
one:The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter455,F,S.,
please-dick here.,
Product Approval Accepts:
®99
Credit Card
Safe
i
• • . e11 N
I MIRa • gib
302 Milton Drive
Fort Pierce,FL 34962
(772)466-4040
e. a . r. t e . e a r e s ffi.... • e e e
Compliant with Florida Building Code 2017(61h ed.)
Compliant:with Florida Product Approval Rule#61G20-3
Compliant.Quality Assurance Program:PRi CONSTRUCTION MATERIALS TECHNOLOGY
FBC Sections:1504.3.2,1507
•• • . .,• •
5V Crimp thru fastened W"rib at each panel edge.and 1 fastener in the center of the panel,24"net coverage,,26GA ASTM
A792,6-50,AZ55,.018,50ksl min.over min.15/32"thick COX plywood deck. Corrosion Resistant fastener#9-15 HWH with
seating washers,metal to wood connections with fastener length to penetrate,5/16"thru.substrate. Fasten along the crown
of the rib in the center of panel,and along the lap.First fastener to be within 3 of panel edges,, Min.8Dx2"annular ring shank
nails spaced 6"O.C.reroofing,with less than 19/32"plywood'(min.15/32"),this attachment is to be used in.addition to.
existing attachment. Deck slope 2:12 or greater and shall be compliant with FBC 2017 6T"ed.Underlayment:See FBC 2017 61"
ed.,Sec..IS07 Table 1507.1.1 "Design Pressure: Spacing:
-69.25 PSF 16,'.O.C.
-129.25 PSF 6"O.C.
26GA.ASTM A792,G-50,A255,.018,50ksi Victorian Crimp Shingle over 15/32"COX/APA Plywood-attached to roof trusses.
Corrosion Resistant Fastener#10 x r Zinc plated,MTW Pancake Head,installed at 2 per panel into lock seam. Panels applied
with 12"exposure,adjacent shingles inserted into lock seam of previous shingle.Deck slope 2:12 or greater and.shall be
I compiiantwith FBC 2017 6m ed,Underlayment:See FBC 2017 67"ed.,Sec.1507 Table 1507.1.1
j "Design Pressure:
-105 PSF
"DESIGN PRESSURE INCLUDES A SAFETY MARGIN OF 2:2
Reference Data:
TEST REPORTS
Hurricane Test Laboratory.(TST-1527) #0224-0501-06 TAS 125(UL 580-941)
PRI Construction Materials Technologies(TST 5878) #FAE-023-02-01 UL 580.06/ULL1897-04z
I.UL 580-941est standards are equivalent to UL 580-06 test standards.
2. UL 1897-04 test standards ore equivalent to UL 1897-12 test standards.
Limitations:
1. Underlayment to be compliance with current Florida Building Cade(FBC)2017 61 ed..see Chart 1507.1.1
2. Minimum slope to be compliant with Florida Building Code 2017 6'ed.,and per with.Manufacturer's installation reference.
3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered
engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are.outside this report.
6. Support framing incompliance w/FBC2017 601 ed.,Chapter 22 Steel,Chapter 23 Wood and Chapter16 Structural Loading.
7. This report does not imply warranty,installation,recommended product use outside of this report.
Certificate of Independence:
Locke Bowden,P.E.does not have,not will acquire a fPrianciatinterest in any company manufacturen�,1� T61,11%1puting products
under this evaluation.. $0 W(!rt,,rr,
Locke Bowden,P.E.is not owned,operated,or controlled by any company,manufacturer,or I ma ro 19;j r this
report. .�` �� E. •�
seal W.
9 fl4
` �� pyi`�•to = .
-�E
.. SSA :�'•'
P
%,'Val . ",.
. tj�,•
'�r,;�SS 00) �,v
5 V Crimp
Fastener-49-15 corrosion resistant w/sealing washers
24"coverage
I
I
I
Fastener:#9 x 15 corrosion resistant with sealing washers.
in Compliance with 2017 Florida Building Code, Section 1507
Perimeter fastening: 6"o.c.
Main Field fasteninglTo:c.
Panel.Width: 26"
Panel Coverage: 24"maximum
26 GA Architectural Metal Roof panel
MINIMUM 2 FASTENERS Fastener.•#10x l"
tt AT LOCK SEAM Zinc Plated,MTW
Pancake Head
FIELD CUT 112 SHINGLE
TO CREATE STAGGERED
j PATTERN
I
l� . r VICTORIAN CRIMP
SHINGLES
i
I
i
I '
k
t :
VICTORIAN CRIMP SHINGLE
D
LOCK SEAM,- s p
x
i w
I
9"EXPOSURE