HomeMy WebLinkAboutProduct Approval (2) {
sa�F•
BCiS Home ( Log In ; User Registration j. Hot Topics Submit Surcharge Slats&Facts ! Publications F5C Staff 4 SOS Site Map Links . Search
I a
Y x Product Approval
USER:Public User
Product Aoomval Menu>Product nr Aonlicatinn.Search>.Aoalication List>Application Detail
i- FL# FL9777-R1I
Application Type Revision
Code.Version 2017
Application Status Approved
Comments
Archived r
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
:Toledo,QH 43659
(740)404-7829
9reg.keeler@owenscorning.com �(,
Authorized Signature - Greg Keeler X��� � R1�
Oreg.keeler@owenscoming.com
Technical Representative
Address/Phone/Email REVIEWER FOR
Quality Assurance Representative ®E COMPLIANCE
Address/Phone/Email STo L U C I E COUNTY
Category Roofing BOCC
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R.Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
Validation Checklist-Hardcopy Received
Certificate of Independence FL9777 R11 COI OCR14002 8a 2017 FBC Evaluation Report Weatherlock
Non-HVHZ.pdf
Referenced Standard and Year(of Standard) Standard near
ASTM D 1970 .2015
'ASTM D 226 2009
ASTM G 155 2005
TAS 103 1995
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/11/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/12/2017
Summarir of Products"
FL# Modeli Number or Name Description -
9777.1 Weatherlock G Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9777 1111 II OCR14002 8a 2017 FBC Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.gdf
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Report
eatherlock Non-HVHZ Ddf
Created by Independent Third Party:Yes
9777.2 Weatherlock G(High Tear) Weatherproofing Underlayment
Limits of Use _ Installation Instructions
Approved for use in HVHZ:No FL9777 R41 Ii OCR14002 8a 2017 FBC EvaluationQe1LQrt
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.Ddf
Impact Resistant:N/A Verified By:Zachary R. Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 1111 AE OCR14002,8a 2017 FBC Evaluation Report
2Lgatherlock Non-HVHZ.pdf
Created by Independent Third Party:Yes
9777.3 Weatherlock MAT Waterproofing Underlayment m-
Limits of Use
Installation Instructions
Approved for use in HVHZ:Yes FL9777 1111,11 OCR14002.8b 2017 FBC Evaluation Report
j Approved for use outside HVHZ:No -Weatherlock HVHZ;ndf
Impact Resistant:N/A Verified By: Zachary R, Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R11 AE OCR14002 8b 2017 FBC Evaluation Report
Weatherlock HVHZ.12d
Created by Independent Third Party:Yes
9777.4 Weatherlock MAT Waterproofing Underlayment
Limits of Use Installation Instructions
Approved.for use in HVHZ:No FL9777 1111 II O R inn 2 8a 2017 FDL Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.pdf
impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure;N/A Created by Independent Third Party:Yes
! Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ Ddf
Created by Independent Third Party:Yes
9777,5 Weatherlock Metal Weatherproofing Underlayment
Limits of Use Installation Instructions,
Approved for use In HVHZ:No FL9777 1111 II oc1114062 R 2017 FBC Eval LaEion Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ,pdf
Impact Resistant:N/A Verified:By: Zacharyl R. Priest PE-74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 1111 AE OCRI4002 8a 2017 FRr'Evaluation Report
Weatherlock Non_HVHZ.pdf
Created by Independent Third Party:Yes
.9777.6 Weatherlock Metal Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes EL9777 R11 II OCR14002 8b 2017 FBC Evaluation Report
'Approved for use outside.HVHZ:No Weatherlock HVHZ:Ddf
Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use, Evaluation Reports
FL9777 R11.AE OCR14002.8b 2917 FBC Evaluation Report
Weatherlock HVHZ,Ddf
Created by Independent Third Party:Yes
77'.7 WeatherLock Specialty Tile&Metal Weatherproofing Underlayment ~
its of Use ---- Installatlort Instructions
Approved for use in HVHZ:No FL9777 R11 II OCR14002.8a 2017 FBC:Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.odF
impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure: +0/-142.5 Created by Independent Third Party Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R11 AE OCR14002.8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.odf
Created by Independent Third Party:,Yes
back ti�*xf
i
Contact Us c:2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an.AA/EEO employer.Copyright 2007 2013 State of Florida:::Privary Statement::AccesslbilitV Statement;:Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850,487.1395,'Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a,personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please dick here.
Product Approval Accepts:
ME ®91E
i
i
I
i
Certificate of Authorization No.29824
CREEK 17520 Edinburgh Drive
Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,C EDITION(2017)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017
1 Owens Coming Parkway
Toledo,OH 43657
(800)438-7465
www owenscornina.com
Manufacturing Location: Brentwood,NH
Houston,TX
i
i
Quality Assurance: UL LLC(QUA9625)
i
SCOPE
Category: Roofing
Subcategory: Undedayments
Code Sections: 1504.3.1, 1507.1.1
Properties: Physical properties
REFERENCES
Enti Report No. Standard Year
PRI Construction Materials Technologies(TST5878) NEI-039-02 01 ASTM D 1970 2015
PRI Construction Materials.Technologies(TST5878) NEI-I)42-02-01REV2 ASTM'D 1970 2015
PRI Constriction Materials Technologies(TST5878) NEI-045-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST5878) NEI-045-02-01 ASTM G 155 2005a
j PRI Construction Materials Technologies(TST5878) NEI=053-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST5878) NEI-053-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST5878) NEI-093-02-02 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-213-02-01 ASTM.D 1623 2009
PRI'Construcfion•Matedals Technologies(TST5878) OCF-237-02-01 UL 1897 2012
1 PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 4798 2001
PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-253-02=02 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-272-02-01 TAS 103 1995
! PRI Construction Materials Technologies(TST5878) . OCF-296-02-02 ICC-ES AC 18W 2012
[CC-ES AC 48 2012
PRI Construction.Materials Technologies(TST5878) OCF-297-02-01.1 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-318-02-01 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-320-02-01 TAS 103 1995
PRI.Construction Materials Technologies(TST5878) OCF-320-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST5878) OCF-321-02-01 ASTM D 1623 2009
PRI,Construction Materials Technologies(TST5878) OCF-322-02-01 UL 1897 2012
PRI Construction Materials Technologies(TST5878) OCF-355-02-01 UL 1897 2012
'Determined to be equivalent to ASTM D 226-09,Type i and 11
i
0CR14002.8a 171.9777-R11 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
OWENS.CORNING ROOFING AND ASPHALT LLC
CREEK i Weatherl-ockV.Self-Sealing Ice&Water Barriers
TECHNICAL SERVICES,LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock@ G WeatherLock@)G is an ASTM D 1970 self-adhesive underlayment constructed from SBS
(Brentwood,NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq.rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock® G is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
max_imum 30 days.
i _
WeatherLock@)Mat WeatherLockO Mat is an ASTM D 1970 self-adhesive underlayment-constructed from
(Brentwood,NH or SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
Houston, M sq.rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq.rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock@ Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
j mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
i
WeatherLock®Metal WeatherLock@ Metal is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood,NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq.rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock@ Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLock@) WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tile&Metal constructed from SBS modified asphalt and surfaced with,a.non-woven polyester fabric.
(Brentwood;NH or The product is supplied in 2.14 sq.rolls.with nominal dimensions of 3-ft x 71.3-ft.
Houston, 7?C
WeatherLock@ Specialty Tile & Metal is permitted to be.used as_prescribed in FBC
Section 1507.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be used with
adhered clay or concrete tile roofing.using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.)or TILE BONDTm Roof Tile Adhesive.(The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
I The maximum roof slope shall be 6:12 when•used with clay or concrete the installations
without battens. Tile shall be-stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLockg)G(High WeatherLock@ G(High Tear)is a self-adhered,underlayment used as an alternative to
Tear) ASTM D 226,Type I or Type II roofing felt and ASTM D 1970 self-adhering polymer
(Houston, 7X) modified bitumen underlayment. The underlayment is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1;95-sq rolls with nominal
i
dimensions of 3-ft x 65-ft.
WeatherLock@ G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roofcoverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
OCR14002.8a FL9777-Rl l Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for rwhich'this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock®Self-Sealing Ice&Water Barriers
TECHNICAL.SERVICES,LLC
PRODUCT APPUCAT ON
Min.Roof Slope: 2:12 in accordance with the FBC
Application: All undedayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked forprotrusion and corrected prior to underlayment
application. Prior to beginning installation, the underlayment shall be unrolled and
i
allowed to relax fora minimum.of 3-5 minutes.
The underlayment shall be installed with the.release backer removed and pressed firmly
into place to ensure complete contact with the deck.The underlayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum;3"side
laps and minimum 6"end laps staggered min.6-ft.from preceding course. Additionally,if
applying WeatherLock®Specialty Tile & Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a,minimum of 3-4 inches across the width
of the lap.
It is permissible to back nail the underlayment 12-inches on-center as needed(nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally, WeatherLock®Specialty Tile& Metal shall be back nailed'
when installed on roof slopes greater than 3:12.
j Min.Application 40°F;Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
j The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC-Section 1504.9.
Undedaymeni System No:1 WeatherLock Specialty Tile 8 Metal Only
Roof Deck: Min. 15132-inch CDX plywood attached to wood supports spaced a maximum 24"o.c.
Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-518-inch 0 tin caps spaced 12" o.c. The applied
underayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.8a FL9777-Rl l Page 3 of 4
This evaluation report is provided'for State.of Florida product approval under Rule 61:G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended,use,or other product attributes that are not
specifically addressed herein.
' OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLockO Self-Sealing Ice&Water Barriers
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
1) This evaluation report is not use in the_HVHZ.
.2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction..
5) The space under the deck,area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap;seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others,in accordance with FBC requirements to resist the design wind
load pressures for components and'cladding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with.
Rule 61 G20-3.
C COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 6"'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
p��.
sic E Ns '�s . 2017.1 a.11
�• 09:06:29
No 74021 % (.,
. * ?.ixwwesmn »d
1 1
-13
STATE OF 441.
i,(��'•�c1 .0 Q ;`,� �` Zachary R.Priest,P.E.
���`S••., O R t• � Flodda,Registration No.74021
Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical,Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC.is not owned,operated,or controlled by any-company manufacturing.or distributing products under
this evaluation.
Zachary R.Priest,P.E. does not have,nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,RE;does not-have,nor will.acquire;a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR14002.8a FL9777-R11 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify,CREEK
Technical Services,LLC of any pr'oduct.changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty;installation,recommended use, or other product attributes that are not
specifically addressed herein.