HomeMy WebLinkAboutProduct Approval (2) 1/29/2019 Florida Building Code Online Business Professional Regulation BCIS Home I Log In I User Registration I Hot Topics i Submit Surcharge I Stats&Fads I Publications I Contact Us BCIS Site Map I Links ( Search I Florida a�. �;6 Product Approval g USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail • FL# FL5259-R28 Application Type Revision Code Version 2017 Application Status Approved Comments KF"VIEWED Fun ' � /� Archived COF7 Cf.' /�IPLIiANCE Product Manufacturer POLYGLASS USA T. �."C- "'>®UNTY Address/Phone/Email . 1111 W.Newport Center Drive Deerfield Beach,FL 33442 " (954)233-1330 Ext242 -malpert@polyglass:cem Authorized Signature Maury Alpert malpert@polygiass.com Technical Representative Maury Alpert 'Me ie CODY Address/Phone/Email 1111 W.Newport Center Drive Deerfield Beach,FL 33442 (912)429-8610 MAIpert@polyglass.com Quality Assurance Representative Ariel Lender Address/Phone/Email 1111 W.Newport:Center Drive Deerfield Beach, FL 33442 (954)233-1230 ALender@polyglass:com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 1:1 Evaluation Report-Hardcopy Received i Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/13/2021 Validated By John W.Knezevich,PE d Validation Checklist-Hardcopy Received Certificate of Independence FL5259 R28 COI 2018 01 COI NIEMINEN.pdf Referenced Standard ancf-Year(of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6164 2011 ASTM D6222 2011 FM 4474 2011 FRSAf W Aprit ZOfZ -MfZ https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2fegOlipJYmiSimlPV6uypRuxszPog%3d°/p3d .1/2 1/29/2019 Florida Building Code Online UL 1897 2012 -Equivalence of Product Standards eeitifietf-By.- Sections from the Code Product Approval Method Method 1 Option d Date Submitted 01/24/2018 Date Validated 01/23/2(118 Date Pending FBC Approval 01/30/2018 Date Approved 04/10/2018 Summary of Products. FL# Model,Number or Name Description, 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved.for use in HVHZ:No FL5259 R28 II 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- Approved for use outside HVHZ:Yes R28.pdf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes Other: 1.)The design pressure in this Evaluation Reports application relates to one particular -FL5259 R28 AE 2018 01 FINAL ER POLYGLASS-UNDERLAYMENTS FL5259- undedayment system(over concrete deck)for R22 .pig use under foam-on tile systems(where the Created by Independent Third Party:Yes underlayment forms part of the load-path). Refer to ER Section 5.6.4 for other.systems, other deck types and associated maximum design pressures.2.)Refer to ER Section 5 for other limits of use. Back Next Contact Us;;2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of-Florida.::Privacy Statement::Accessibility Statement::Refund Statement. Under Florida law,email addresses are public records.If you do not want your e-mail address,released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions;please contact 850.487.1395.*Pursuant to Section 455.275(1), - Florida Statutes,emcbive October I,2w,licensees licensed under Chapter 455 F.S.must provide the Department with an email address irthey have one.The emails provided.may,be used for official.communication.with the licensee,,However email addresses are public record.,If you do not wish.to.supply a.personal address,,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: - Credit Card Safe` https:/Avww.floridabuilding.org/pr/pr app dtl.aspx?param--wGEVXQwtDgvbSgAaZp3Crk2vS%2fegOlipJYmiSimlPV6uypRtiXszPog%3d%3d 212 NEMG etc.. Certificate of Authorization N32455 353 Christian Street, Unit#13 Oxford, CT 06478 (203) 262-9245 ENGINEER' EVAtUATE TEST CONSULT CERTIFY EVALUATION REPORT - - --------- - --- ------------------- ------ --------- --------- — - - -- ----------- ------------- -- --------- -------- ---- ----- Polyglass.USA,.t= Evaluation.Report P12060.M 09-1124 1111 West Newport Center Drive F1.5259-1128 Deerfield Beach;FL 33442 Date of'lssuance:02/24/2009 (954)233-1230 Revision 24:01/24/2018 SCOPE: This Evaluation:Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of . . - construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the a Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. Ca�triawED COWUANCE: This Evaluation Report is valid until such time as the named product(s.1 changes, the referenced. Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOjetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be-displayed in advertising-literature. If any portion of the Evaluation Report is displayed,then it-shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: Robert 1.1%.Nieminen P.E. •.:�, .: -:orr-r The facsimile seal appearing was authorized by Robert Nieminen, Florida Registration No.59166,Florida DCA ANE1983 '': '" `�' •'� S�•�••• P.E.on 01/24/2018.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOketc. does not have, nor does it intent to acquire or wit it acquire, a financial interest in any company manufacturing Or distributing products it evaluates. 2. NEMO I etc.is.not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. :Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in anyway,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOJetc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 6!h Edition(2017)-Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2.' STANDARDS, Section Pro a Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind UpMi (it 1897 2022 1507.2.3/1507.1.1 Physical Properties ASTM D226 2009 1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI Aprif 201Z 2012 1507.11.2 Physical Properties ASTM D6164 2011 1507.111 Physical Properties ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Enti Examination Reference hate FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000 PRI(TST 5878) Physical Properties PRIO1111 04/08/2002 PRI(TST 5878) _ Physical Properties PUSA-005-02-01 0113112002 PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRY W59M Physical Properties PUSA 0i3-02-03 12/2312aa2 PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI(TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI(TSTSM Physical Properties PUSA-033-02-01 01/12/2006 PRI(TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI(TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI(TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI(TST5879). PhymcalPropert'ies PUSA-088-02-01 07/29/2009 MTI(TST 2508) Physical Properties JX20H7A 04/01/2008 MTI(TST 2508) Physical Properties RX14E8A 01/29/2009 ERD(TST6049) Physical Properties 11M.09.99-1 02/08/2000 ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 M(TST 6049) Physical Properties 02200.07.03 W14/2003 ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD(TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD(TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 _ERD(TST 6049) Physical Properties P11030.]1.09-1 11130/2009 ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009, ERD(TST 6049) Physical Properties P11030.11.09-3 11/30/2009 ERD(TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011 NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6 EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments,(954)233-1230 Revision 24:01/24/2018 Page 2 of 14 ONEMOjetc. Enti Examination Reference gate ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD(TST 6049) Physical'Properties C41420.09.12-3 00111/2012 ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD(TM048) Wind Uplift P1738.02.07--112 04/29/2013 ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD(TST 6049) Wind Uplift P11751.05.03-RI 11/26/2013 ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD Mr6049) Physical Properties 6020.0714-1 09/D8/2014 ERD(TST 6046) Physical Properties 6020.09.14-2 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014 'ERD(TST 00491 Physical Properties 6020.09.14-4 09109/2014 ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD M 6D49) Physical Properties P46520.10.14 M/03/2014 ERD(TST 6049). Physical Properties P43290.10.14 10/17/2014 ERD(TST 6049) Physical Properties PLYG-SC7550.03.15. 03/24/2015 ERD(TST 60491 Physical Properties P40390.04.15 04/03/201S ERD(TST 6049) Physical Properties P44360.10.14-R1 05/18/2015 ERD(TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015 ERD M60491 WrndUp6ft PLYG-SC8905.05.16-1 05T17/2016 ERD(TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016 ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 ER15(TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016 ERD(TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017 ERD(TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017 ICC-ES(EVL 2396) IBC Cempriance ESR-1697 11/01/2014 Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL,U.C.(QUA9625) Quality Control Service Confirmation Exp.10/05/2018 4s' PRODUCT©ESCRIPTIQIW. 4 2 Mec a'hicallyFastened U her layments 4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester-reinforced,SBS modified'bitumen base sheet. 4.1.3 Polyglass G2 Base is a fiberglass-reinforced,asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet. 4 2 Self=Adhering Underiayments 4.2.1 Polystick MTS.or Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane,.glass fiber reinforced,surfaced with polyolefinic film surface;meets FRSA/TRI April 2012. 4.2.2 Polystick-lR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an aggregate surface;meets ASTM D1970. 4.2.3 Polystick TU Pius is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a polyester fabric surface;meets ASTM D1970 and FRSA/TRI April 2012. NEMb ETC,I.I.C. Evaluation Report 1512060.02.09-1124 Certificate of Authorization#32455 EP EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 3 of 14 ONEMOletc. 4-2-4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced,with a granular surface;meets FRSA/TRI April 2012. 4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/M2 polyester fabric surface;meets ASTM 61970 and FRSA/TRI April 2012. 4.2.6 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester reinforced,APP modified bitumen cap sheets;meet FRSA/TRI April 2012. 4.27 Polystick Dual Pro"" is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970. 4.2.8 ,Polystick Tile Pro"' is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970 and,FRSA/TRI April 2012. 4.2.9 Polystick MU-X is a nominal 54-mil thick dual-layer 'rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section 4 3 Mechanically Fastened and/or Bonded tlnderlayments y _ F 2 e 4 S 4.3.1 - Elastoflex 1G TU is a polyester reinforced, modified bitumen the underbyment composed of a sand-surfaced SRS' ;modified bitumen back-side and granule-surfaced APP modified bitumen top-side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012(04-12) beneath mechanically.fastened tile roof systems or Hot Asphalt applied "Cap Sheet." in the "Two-Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems. . 4.3.2 Elastoflex S6 G.and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D6164. Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to"Mineral Surface Roll Roofing" (ASTM f)63811 Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet"in the'Two Ply System"from FRSA/TRI April 2612 (04-12}beneath mechanically fastened or adhered the roof systems. Elastoflex S6 G FR is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12)-beneath mechanically fastened tile roof systems. 4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM €36222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the'Two Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat Applied "Cap Sheet" in the `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMCr(etc. not Robert Nieminen,P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting.data for the prepared roof covering. NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R24 Certificate ofAuthorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION - FL5259-R28 Polyglass Roof Underlayments,(954)233-1230 Revision 24:01/24/2018 Page 4 of 14 ONEMOletc. 1 5.5 Allowable Roof Covers: Ji TABLE 1 R006 COVER OPTIONS' a Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal Wood Shakes>� Slate Shingles Elastobase Yes Yes Yes Yes Yes Yes (Base Sheet in 2-ply system) (Base Sheet in 2-ply system) Yes Yes ElastobaseP Yes (Base Sheetirn2j*system) (Basesheetn2-plysystem1 Yes Yes Yes Polyglass G2 Base No Yes Yes No No No (Base Sheet in 2-ply system) (BaseSheet in 2-ply system) Polyglass APP Base No Yes Yes No No No (Base Sheet in 2-ply system) (Base Sheet in 2-ply system) Polystick hM or MTS PLUS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU P No Yes Yes (See 5.5.1) No No No Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick TU Max No Yes Yes (See 5.5.1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes Elastoflex.G TU Yes Yes Yes (See 5.5.1) Na Yes Yes Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes -Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule-Hide SA-APP Cap Sheet Yes Yes Yes (See 5.5.1) No Yes Yes or SA-APP Cap Sheet(FR) 5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations. TABLE 1A AuO1NABLE TILE ADHESIVE j UNDERLAYMENT COMBINAT10N51 Adhesive Florida Product Underlayments Approval DAP Foam Touch'n Seal Storm Bond Roof FL14506 Polystick TU Plus,Polystick TU Max Tile Adhesive Dow TileBond' FL22525 Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro, ICP Adhesives Polyset®AH-160 :FL6332 Elastoflex G TU,Elastoflex56 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro, ICP Adhesives Polyset®RTA-1 FL6276 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) I Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,U.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 5 of 14 nN WNEMOletc. 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Polystick(all variations),Dual Pro,Tile Pro,Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)self-adhered to: ➢ New untreated plywood;ASTM D41 primed new untreated plywood, Existing plywood;ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow.Pine; ASTM D41 primed Southern Yellow Pine;. ASTM D41 primed structural concrete; Hubei Engineered Woods "Z1P System" Panels (designed and installed to meet wind loads for project). Note:Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes- Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. PolyflexG or PolyflexG FR torch-applied to: ,➢ ASTM D41 primed structural concrete. 5.6.2 Bond-to-insulation: Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)self-adhered- to: ➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard;Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board- Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ .Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. . Polyflex.G or Polyflex G FR torch-applied to: ➢ ASTM D41 primed structural concrete;Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on the systems, insulation-attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanically Attached Base laver: Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) Dual Pro or Tile Pro self-adhered to: ➢ ASTM.D226,Type L or ll felt;Elastobase;Elastobase P or Mule-Hide Nail Base. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P,Mule-Hide Nail Base or Polyglass G2 Base. PolyflexG or Polyflex.G FR torch-applied to: ➢ Elastobase;Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile-systems, base layer'shall be attached per minimum ;requirements of FRSA/TRI April 2012(04-12),Appendix A,Table 1,or as listed in Section 5.6.4 herein,or as tested in 'accordance with FBC Section 1504.3.1. NEMO ETC,U.C. Evaluation Report 1312060.02.09-1124 Certificate of AuffiDrization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 6 of 14 ONEMOletc. 5.6.4 Wind Resistance for Underlayment Systems in Foam-0n Tile Applications: FRSA/TRI April 2012 (04-12} does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on the applications. Maximum Design Pressure,is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04- 12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood-to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional)Pofystfck MTS or Polystick MTS PLUS,seff-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #2 Maximum Design Pressure=-97.5 psf- Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Pry: (Optional)Polysfick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1W ring shank nailsthrough 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure=-105 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base-Pry: (Optional)Polystick WITS or Polystick MTS PLUS,serf-adhered. Underlayment:Polystick TU P;Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1W ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced'12-inch o.c. #4 Maximum Design Pressure=-135 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)PG100 or ASW 041 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment:.Polystick TU P,Polystick TU Plus;Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #5 Maximum Design Pressure—-315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Tile Pro;Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #6 Maximum Design Pressure=-622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #7 Maximum Design Pressure=-30.0 psf*: Deck:. Min.15/32-inch OSB to meet.project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) 1=asteners: 11 ga.x 1.25-frith long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R24 Cettificateof Authorization,#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954).233-1230 Revision 24:01/14/2018 Page 7 of 14 ONEMOletc. #8 IVlaximum Design Pressure=-37.5 psf*: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: i1 ga.x 1.25-'inch Tong x 1-'inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #9 Maximum Design Pressure=-37.5 psf*: Deck: Miin.19/324nch plywood to meet project requirements to satisfaction of Authority Having Juriisc ctiori. Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch a c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #10 Maximum Design Pressure=-45 psf*: Deck: Min.19/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)layer ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 44rich o.c.at the 2-'inch wide side laps and 4-inch o.c,at two(21 equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS or Polystick MTS PLUS,self-adhered: Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex O TU,applied in full mopping of hot asphalt. #11 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two(2)layers ASTM 0226,Type It felt' ,Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (OptfonA for use with serf-adhering underrayrnent only)Polystick MTS or Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #12 Maximum Design Pressure=-45 psf: Deck: Min.15/32-inch.plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. base Sheet: Elastobase(sanded top surface for hot-asphaft or torch-applied cap or poly-film surface for torch-applied capJ Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in fell mopping of hot asphalt or Polyflex G;torch-applied. #13 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 12=inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #14 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Efastobase or Mure-Wide Nail Base(poly-fTm top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6 EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 8 of 14 ONEMO etc. #15 Maximum Design Pressure=-5Z.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hat-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #16 Maximum Design Pressure=-60 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5J8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #17 Maximum Design Pressure=-60 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #19 Maximum Design Pressure=-67.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment) 'Fasteners: 12 ga.x 1.25=inch long x 3/84nch head diameter annufar'ring shank roofing nails at 1=5/84nch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch- applied. #19 Maximum Design Pressure=-75 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: , 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch- applied. #20 Maximum Design Pressure=90 psf: Deck:. Min:15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base.Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners. Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #21 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. ;Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal' Plates .Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. 'Underlayment: Elastoflex G TU or Elastoflex SIS G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #22 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. NEMO ETC,-LLC. Evaluation Report P32060.02.09-1124 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 9 of 14 ONEMOletc. ##23 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates, OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners. Spacing: 94rich o.c.at the 44nch wide side laps and9-Tnch o.c.at four(41 equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch- applied. #24 Maximum Design Pressure=-97.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-Tndi head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus;Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #25 Maximum Design Pressure=_-105 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o c.at the 2-Inch wide side laps-and 6-inch o.c.at three j3)equally spaced staggered center rows: Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 426 Maximum Design Pressure=-112.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 64rich O.C.at the 44nch wide side Taps and 5-inch o.c.at four(4)equally spaced staggered center.rows. Primer: PG100 or ASTM D41 primer at all tin-caps, Base Ply: Polystick MTS or Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mfule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #27 Maximum Design Pressure=-120'psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates. Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows: Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #28 Maximum Des1gn_Pressure.=.-n0_psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. .Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.1 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum Design Pressure of-45 psf. NEMO ETC,LLC. - Evaluation Report P12060.02.09-R24 Certifkate of Authorization#32455 a EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 10 of 14 ONEMOjetc. 5.6 4.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or"exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shaN employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 3G-days after installation. Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation. Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro,Tile Pro or Elastoflex G TU shall not be left exposed for longer than 180=days after installation. Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30 days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex.G only), in which ease the maximum exposure is 180 days. 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition,tested at standard laboratory conditions. Agreement between.purchaser and seller,as set forth in Section 4.3,Note 1 of ASTM D1970-15,should be established.as to slip resistance. 5.9 Tile Slippage Limitations(FRSA/TRI April 2012(04-12)): When loading roof tiles on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as- follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. �.,.. - ,r.;TaeLii2t'[luf�s�r?Ac�Wwnt�a'noti►s>oR�ISEa D �llySTau�nolus _ w ,_,.� Underlayment Tile Profile Staging Method Maximum Slope Elastoflex G TU Flat 10-tile stack 7:12 Lugged 8-tile stack(6 over 2) 6:12 Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polystick MTS or MTS PLUS Flat 6-tile stack(4 over 2) 5:12 Lugged 6-tile stack(4 over 2) 4:12 Polystick Tile Pro Flat or Lugged, 6-tile stack(4 over 2) 7:12 Flat 6-tile stack(4 over 2)or 10-tile stack 7:12 Polystick TU Max Lugged 6-tile stack(4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat 6-tile stack(4 over 2) 6:12 Lugged 6-tile stack(4 over 2) 4:12 Flat or Lugged 6-tile stack(4 over 21 7:12 ' Polystick TU Plus Flat or Lugged 10-tile stack 6:12 Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile.stack(4 over 2) 4.12 NEMO ETC,U.C. Evaluation Report P12060.02.09-1124 Certificate of Authorization#32455 6TM EDITION(2017)FBC NON-HVH2 EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2015 Page 11 of 14 i ONEMOletc. 6.: INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). '6 3 Elastobase,Elastobase P or Mule Htde NaIF Base f � - 6.3.1 Non-Tile Applications: Shag be installed in compliance with the codified requirements for ASTM D226, Type It underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase,Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick,Polyflex SAP, Polyflex SA P FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FRI, self-adhered, Elastoflex G TU, Elastoflex SI-s, G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are those associated with the top-layer underlayment,as set forth in Table 1. 6.3.2 Tile Appttcations. Elastobase,Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the"Two Ply System"from FRSA/TRI April 2012(04-12). Reference is made to Table 1 and Section 5.6.4 herein,coupled with FRSA/TRI April 2012(04-12)Installation Manual. 6 4 Polystick MT$,MTS PLUS,IR-Xe,TUaP,TU Plus,TU Max,Dual Pro,Tile Pro'or MU X or Polyflex SAP,Potyflex SAP FR;`_ Mule Hide SA APP Cap Sheet or Mule-Hide SA APP Cap Sheet(FR) . 6A.1 Shall be installed in compliance with the codified requirements for ASTM D1970(except Polystick TU P)underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers: Alt self-adhering materials,with the exception of Polystick TU Phis, Polyflex SAP or SAP FR and Mule-Hide SA-APP ,Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule- Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter metal disk or Simplex-type metal cap riait,at a minimum rate o€12"o.c. Polystick TU Pius should be back- nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back-nailed. All seal-lap seams (selvage laps) must be r . firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of 7 t the top sheet to the end of the glue pattern (.the sheet will overlap the fabric). View of Ovelap Seam of Dual P[o aadTde Pro All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus,Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys, or exposed roofto wall details NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6TM EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments,(954)233-1230 Revision 24:01/24/2018 Page 12 of 14 ONEMOletc. Repair of Polystick membranes is to be accomplished by applying Polgplus 50 Premium Modified Wet/Dry Cement or Polyglass PGS00 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch.patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted-roller or,on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches,laps(min.28 lb roller)or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 'Tile Applications(not allowed for Polystick Dual Pro,IR Xe or Polystick MU X): Reference is made to]FRSA/TRI April 2022 (9412) lnsWation Manual and Table 1 herein, using the instructions 'noted above as a guideline. For mechanically fastened tile roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s),Base Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1. For adhesive-set tile applications,refer to Section 5.6.4 herein. 6.4.4 Two(2)_Ply Underlayment Systems: Polystick NITS or MTS PLUS followed by Polystick MTS,MTS PLUS,TU P,TU Plus,TU Max,Tile Pro,ML14 or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired. Polystick MTS or MTS PLUS followed by Polystick TU P,TU Plus,TU Max,Tile Pro or Polyflex SAP is allowable for use `under foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. ;b 5 Elastoflex G TU,Elastoflex S6 G or Efastoflex°S6 G Fit > w 6.5.1 Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to"Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the"Single Ply System"from FRSA/TRI April 2022(04-22)beneath mechanically fastened tile roof systems or the Hot Asphalt applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2022(04-3.2)beneath mechanically fastened.or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System" from FRSA/TRI April 2022 (0-12)beneath mechanically fastened tile roof systems or the Hot Asphalt applied"Cap Sheet'In the"Two Ply System"from FRSA/TRI April 2012(04-22)beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 6 FR is for use as an alternate to Wineral Surface Roll Roofing"(ASTM D6380,Class My in the"Single Ply-System"from FRSA/TRI April 2022(04-22)beneath mechanically fastened tile roof systems or the Hot Asphalt applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2022(04-22)beneath mechanically fastened tile roof systems. 6.5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt-applied to the ,substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6 6 f Polyflex G or Polyflex G FR 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use as an alternate to the Heat Applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012(04-22)beneath mechanically fastened or adhered tile roof systems(Base Sheet Limited per 5.6.3). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2022(04-22)beneath mechanically fastened tile roof systems(Base Sheet Limited per 5.6.3). NEIVIO ETC,I.I.C. Evaluation Report 1312060.02.09-1124 Certificate of Authorization#32455 a EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 13 of 14 ONEMOjetc. 6.6.2 PoWlex G or Polyflex G FR shall- be fuNy torch-applied to the substrates noted in Section 5.6. Side laps shalt be minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Stal(ng: 6.7-1 ;Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment Refer to Table 2 herein,and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter-battens,as required by the tile manufacturer and FRSA/TRI April 2012(04-12)must be used on all roof slopes greater than 7j2- `Precautions should be taken as needed, such as the use of battens or nait- boards,to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 Polyglass specifies the.minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-eight(48)hours. 7. BUILDING PERMIT REQUIREMENTS: As required by-the Building.Official or Authority Having Jurisdiction in order to properly evaluate the installation-of this product. S. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C.61G20-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. Plant `Saeccatlon Product s_. Fernley;NV,Hazleton,PA&Winter Haven,FL ASTM D197G Polystick MU=X Hazleton,PA . M-D 13-0004 Elastoflex G TU ASTM D1970 Polystick IRXe Hazleton,PA&Winter Haven,FL ASTM D1970&FRSA/TRI April 2012 Polystick TU Plus ASTM D1970&FRSA/TRI April 2012 Polystick TU Max. Tuscaloosa,AL ASTM D4601,Type II Polyglass G2 Base ASTM D226(physicals) Elastobase,Elastobase P ASTM D6509 Polyglass APP Base FRSA/TRI April 2012 Polystick MTS,Polystick MTS PLUS FRSA/TRI April 2012 Polystick TU P Winter Haven,FL FRSA/TRI April 2012 Polyflex SAP,Polyflex SA P FR ASTM D1970 Polystick Dual Pro ASTM D1970&FRSA/TRI April 2012 Polystick Tile Pro ASTM D6164 Elastoflex S6,Elastoflex S6 G FR ASTM D6222 I Polyflex G,Polyflex G FR 9.- QUALITY ASSURANCE ENTITY: UL,LLC-QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 14 of 14