Loading...
HomeMy WebLinkAboutProduct Approval 12/23/2919 Florida Building Code Online BCIS Home ( Log In User Registration Hot Topics Submit Surcharge i Stats&Facts a Publications Contact Us aLIS Site Map'! Links ' Search Fbirida ` C ..y Product Approvalr�s USER:'Public User &V4^.xr°�'g 6fA451 "w97X'�ci'wJ:IIU1 Product Ail XgXW Menu>Product or Agoiication Search>ggolication List>Application Detail FL# FL10674-R15 Application Type Revision Code Version 2017 r Application Status Approved h " f ' .;z Comments M Archived is Product Manufacturer Owens Corning " Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 3= (740)404-7829 _ greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY `v Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative s" Address/Phone/Email Category Roofing Subcategory Asphalt Shingles x; Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M.Nieminen ".` Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies,LLC. Quality Assurance Contract Expiration Date 04/20/2020 1 Validated By John W.Knezevich,PE t Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R15 COI 2019 01 COI NIEMINEN.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D197.0 2015 ASTM D3161 2016 apt: ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By r' Sections from the Code fi https://www.floddabuilding.org/pr/pr app_ g.aspx?param=wGEVXQwtDgtBNbEY5Vm/o2boQTm/o2b6w7ahReglCQ8ucR6ixEDL76gG32Q9MA°/m3d°/m3d 1/2 12/23/2019 Florida Building Code Online A WP ;3 k Product Approval Method Method 1 Option D =:x Date Submitted 08/15/2019 Date Validated 08/15/2019 F� t Date Pending FBC Approval 08/21/2019 Date Approved 10/15/2019 w aad6 � '�"•��� ��� Summa of Products FL,# Model,Number or Name ,; Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter h s g p g and hip&ridge shingles Shingles and Starters ' Limits of Use Installation Instructions > ' Approved for use in HVHZ:No FL10674 R15 II 2019 08 FINAL ER OC ASPHALT vh Approved for use outside HVHZ:Yes SHINGLES F1_10674=R15.12d Impact Resistant:N/A Verified By: Robert 1.M.Nieminen PE-59166 o Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER,Section 5. Evaluation Reports FL10674 R15 AE 2019 08 FINAL ER OC ASPHALT " SHINGLES FL10674-R1S.pdf a Created by Independent Third Party:Yes e MR ME r- _r, r Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 -< The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privag,Statement::AaessibiliV Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to S e w this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an emall address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the i Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. �6 Product Approval Accepts: e 5�y h Credit Card . a Safe 4 https://www.floridabuilding.org/pr/pr app_otl.aspx?param=wGEVXQwtDgtBNbEY5V%2bC)QT%2b6w7ahReglCQ8ucR6ixEDL76gG32Q9MA%3d%3d 2/2 NEW etc. Certificate of Authorization#32455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION Owens Corning Evaluation Report 037940.02.12-1110 One Owens Corning Parkway FL10674-R15 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)464-7829 Revision 10: 08/15/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility location(s). MEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "MEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: ?tip�'`•.���:%-, Robert J.M.Nieminen,P.E. �y�p��.' a:s The facsimile seal appearing was authorized by Robert ...r,S;I y.`u��`� Nieminen,P.E.on 08/15/2019.This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 :1'j electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOIetc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO 1 etc.nor Robert Nieminen,P.E.are,in anyway,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design.guidance unless retained specifically for that purpose. 02018,NEMO ETC,LLC ONW' o etc. ROOFING SYSTEMS EVALUATION: 1. •• Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 61 Edition(2017)Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property _Standard Year 1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various PRI(QUA9110) Quality Control Service Confirmation 04/05/2020 4. PRODUCT 4.1 ACCESSORY STARTERS: 4.1.1 Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 Starter Shingle Roll is a mineral-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen starter strip, nominal 7.2-inch wide x 33-ft 4-inch long roll,for use with asphalt shingles. Meets ASTM D1970. 4.2 ASPHALT SHINGLES: 4.2.1 Classic'and Supreme®are fiberglass reinforced,3-tab asphalt roof shingles.Meets ASTM D3462. 4.2.2 Berkshire®are fiberglass reinforced,4-tab asphalt roof shingles. Meets ASTM D3462. 4.2.3 Duration®,TruDefinition° Duration% Duration'Premium Cool,TruDefinition°Duration®Designer Color Collection, TruDefinition® Oakridge% Oakridge and WeatherGuard° HP are fiberglass reinforced, laminated asphalt roof shingles. Meets ASTM D3462. 4.3 HIP&RIDGE SHINGLES: 4.3.1 Berkshire*Hip&Ridge Shingles with Sealant,DuraRidge®Hip&Ridge Shingles with Sealant,ProEdge®Hip&Ridge Shingles and WeatherGuard"HP Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. Meets ASTM D3462. NEMO ETC,LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION -FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 2 of 10 • 1 OMEMO etc. 5. LIMITATIONS: 5.1 ''This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report'is not for use.in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of'this product. 5.4 Wind Classification: 5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and 11905.2.6A to ASTM D3161,Class F and/or ASTM D7158, Class H,indicating acceptable use in all wind zones UP to Vasa=150 mph(V It=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C,as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.2 . Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating acceptable use in all wind zones up to Vasd=150 mph (Vast=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. INSTALLATION:6. 61_ GENE"' Ct- .6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2- - ACCESSORY STARTERS:' 6.2.1 Installation of Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions,using minimum five(5)nails per strip. Fen undedayment Deck Fek—k4ayment txst WWdhlred eath I v SeU-adhered taWnWyman weathertocke l undedayinent m9 edge ad Drip edge / 9 blew Nails located dad 2-3"from ears T�'tmm cave I�t�SSttrtrtpp Self-seaMOadhosiva FWlfustSnner6ettgFfo S3eot 9.dnewe shingle wnh ;; \ positioned along eave whh 6'—ad -\ P ned gsaro e"removed Starter Strip shingle overhangs eaves and takes lh=YY Start SuipPlusavuhangc eaves andraken tsars• Figure 1:Minimum Nailing,Starter Strip Figure 2:Minimum Nailing,Starter Strip Plus NEW ETC,LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 3 of 10 ONEMO I etc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Deck a� Underlayment Drip edge J £ Z4at Drip edge kf r Starter Shingle Roll adhered directly to underlayment and x primed drip edge " Self-sealing adhesive positioned along eaves Figure 3:Starter Shingle Roll 6.3 ASPHALT SHINGLES:; 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: ➢ Berkshire®shingles require minimum five(5)nails per shingle. ➢ WeatherGuard®HP shingles require minimum six(6)nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Classic®&Supreme: r Normal Mansard or Area pare Normal Mansard or Area pare Wind Areas High Wind deevanes y Wind Areas High Wind deavanes y Area porn vientos normales Areas vientos fuertes Area pare vientos normales Areas vientos Mertes 11" 1' 12 121 . . . . . . . . . . . W Exposure 5 518"Exposure Exposicidn Exposicldn Figure 4:Minimum Nailing,Classic&Supreme Figure 5:Minimum Nailing,Classic&Supreme (Standard Size) (Metric Size) NEMO ETC,LLC Evaluation Report 037940.02.12-1110 Certificate ojAuthorization rY32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 4 of 10 ONEMOjetc. 6.3.1.2 Berkshire®: Seahm strip Sealant Strip ;Laura da'sellador Le tira de Mlador I _ lam%-►°.� t-i �e=-►• •«--►��--.• •«---.�r-�• :8 W.` 9 Yf 9 Yt 8 Yf "8�h" 8 rh" 8 W, 8 W, Figure 6: 5-Nail Pattern,Berkshire Figure 7: 6-Nail Pattern,Berkshire sealant strip. ,W ITra de sellador. `s"Vf' aYT 811E 8:Yt J- 'QsIihAiWln'g ceme Cemenfo de who ait6 Figure 8: Mansard or Steep Slope Pattern,Berkshire NEMO ETC,LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVH2 EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 5 of 10 OMEMO etc. 6.3.1.3 Duration®,TruDefinition®Duration,Duration®Premium Cool&TruDefinition'Duration'Designer Color Collection: 4-Nail Fastening Pattern SureNaft fastening area width Nail,Typical, 12" 1" 'ih+wrs�untryo Swa`:Sn7� .- �•"b�E �'8 ff.+�9 s+�a+w;=''`.<• Ous"s CominoSusNissa'"., .•. �aA Figure 9:Standard 4-Nail Pattern,Duration 6-Nail Fastening Pattern SureNail®fastening area width, Nall;Typical'1" 12" I 12." 1" wenzcn<n3nosv�a • `:ta nse .mo,wm„ •o."nsconnnas�,rsx • Figure 10: 6-Nail Pattern,Duration Fastening for Slopes GreateeThan 21:12 SureNal10 fastening area width Nail,Typical 1" 12" 12" 1" peens[otNnp SveNadL •, •., n•S�Iu�:I�Wa •O„t c+CaNrm.SweliaiL • . 6-1i8" 5 518" �Zn Four 1"Spots of Asphalt Roofing Cement Figure 11: Mansard or Steep Slope Pattern,Duration NEMO ETC,LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 6 of 10 OMEMO etc. 6.3.1.4 TruDefinition®Oakridse®,Oakridse®: A Nail Pattern Esquema con 4 clavos 5 518"Exposure Nails 5 518 Exposure Erposfcl6nde661*pulg. Claws Eopstci6 s66/8pulg.. Figure 12:Standard 4-Nail Pattern,Oakridge .6 Nail Pattern_ Esquema con 6 clavos, r r. 12 5'BAr Exposure; Claws ' '6 5/8"Exposure Erposiddp deb5/8pu1g. FXposwft&.65/8 puig. Figure 13:6-Nail Pattern,Oakridge Fastenhigfor,Slopes Greater Than.21:12 -Su_raNag&fastening area:widW Nell,Typical 1" 12" 12" 1" � -�,cmomusu.w:w .• - wrx �.m ••: cm swu „r.. 6.118. _ j2" Four 1-Spots 61 Asphalt Reefing Cement Figure 14:Mansard or Steep-Slope Pattern,Oakridge I MEMO ETC,LLC Evaluation Report 037940.02.12-1110 Certificate of Authorizationrl32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 7 of 10 ONEMOle-tc. 6.3.1.5 WeatherGuard®HP: I 1 122 i�'-�I I�120g, 1W CAM 5 518'bpost►e 5 5W E�yomre Ev cdn de 5 51890X Expos C*do 5 5iE puSg. Figure 15:6-Nail Pattern,WeatherGuard HP 6 Nail Pattern Esquema con 6 clavos Nail 6118°from bottom of shingle Clove a 6 118 pulg.de la 5 518°Exposure g Fasteners rs pie inferior de la tqa Exposici6n de 5 518 pulg. J IE-- 2- ttpy . . . . ow!t . — t: Four 1°Spots of Asphalt Roof Cement Guatropunfos de cemento de techo de asfafto de f pu{gada Figure 16:Mansard or Steep-Slope Pattern,WeatherGuard HP 6.4 HIR&RIDGE SHINGLES: 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ➢ Berkshire® Hip and Ridge Shingles with Sealant and DuraRidge® Hip & Ridge Shingles with Sealant require minimum two(2)nails per shingle. ➢ WeatherGuard® HP Hip and Ridge Shingles and ProEdge® Hip & Ridge Shingles require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. NEMO ETC,LLC Evaluation Report 037940.02.12-1110 Certificate ojAuthorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-RlS Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 8 of 10 I i ONEMO etc. 6.4.1.1 Berkshire®Hip&Ridge with Sealant and DuraRidge®Hip&Ridge Shingles with Sealant: Fig' A Fig. B Top View Prevailing Wind Direction �— Direccion del viento predominante ' . Vista superior ' Nail 2W, clavo Nails a • OwensComnySigeNaO • Clavos I I 4 I I I I el c �--arExposure �I e - IErposid6n de 8 ping t r • I A 12" Figure 17:Isometric View,Berkshire and DuraRidge Figure 18:Plan View,Berkshire and DuraRidge 6.4.1.2 WeatherGuard®HP Hip&Ridge Shingles: Fig:A, s 4 Fig.C H'ip.&Ridge Sfi'i&Fastening, Prevailing Wind Top V.law' Direction A ' A Nails 4 4 Nails Nails I I T C 1; T �1 Exposure 51, Exposure 1 ' 12ci �. Figure 19:Isometric View,WeatherGuard HP Hip&Ridge Figure 20:Plan View,WeatherGuard HP Hip&Ridge i NEMO ETC,LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization N32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/1S/2019 Page 9 of 10 NNEMOjetc. 6.4.1.3 ProEdge®Hip&Ridge Shingles: Prevailing Standard Wind Direction Fastening Sealant Strip Pattern J� *_ S'Exposure 1n'I �41 ��►I I—1 12" Sealant Fasten 71 7jhf 6"Exposure Cover Exposed Fasteners with 'Roof Cement I-12"—� Figure 21:Isometric View,ProEdge Figure 22: Plan View,ProEdge 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. BUILDING8. • As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. i 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 CA requirements. 10. QUALITY AssURANtE PRI Construction Materials Technologies, LLC—QUA9110; 813 621-5777;bwilson@pricmt.com END OF EVALUATION REPORT- MEMO ETC,LLC Evaluation Report 037940.02.12-1130 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 10 of 10