Loading...
HomeMy WebLinkAboutProduct Approval (4) FLORIDA D*PARTWW OF Business 1 1 Regulation BCIS Home I Lag In I User Registration Hot Topics Submit Surcharge I Stats&Facts I Publications I Contact Us I BCIS Site Map I Links Search doFlorida ri "'i Product Approval IfLe USER:Public User Grz�m�x5�tm � RECEIVED Product Approval Menu>Product or Application Search>Application List IVE FEB1[_� _ 1 �' r`� J Searc Criteria Refine Se�archl ST.Lucie 6unty,P mre mre ming Code Version 2017 FL# 15213 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results=Applications iype Manufacturer Validated By Status FL15213-R3 Revision Plastpro Inc./Nanya Plastics Corp. Ryan J.King, P.E. Approved HistoCategory: Exterior Doors (8 13)767-6555 Subcategory:Swinging Exterior Door Assemblies *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copvriaht 2007-2013 State of Florida.::PrlvaN Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here_. Product Approval Accepts: Credit Card Safe https://www.floridabuilding.org/pr/pr_app_Ist.aspx 2/12/20,4:47 PM Page 1 of 1 ll . Pro '114;10%IMPAMM1110 Of: - � 9 Lim 01 M11V BCIS Home I Login I User Registration 'Hot Topics I Submit Surcharge I Stats&Facts I Publications ContactUs I BCIS Site Map I Links I Search b a n"�Product Approval e' USER:Public User V",�' ^�cp q'e?L• t r.C�JF;YAT. . Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL15213-113 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES,CA 90045 X440)969-9773 Ext 16 rickw@rwbidgco.nsultants.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 X440)969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 16 ronoconnell@plastpro.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J. King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL15213 R3 COI (b)Certificate of Independence.odf Referenced Standard and Year(of Standard) Standard Year 101/I.S.2 1997 101/I.S.2/NAFS 2002 AAMA/W DMA/CSA101/I.S.2/A440 2005 ASTM E1886 2002 ASTM E1996 2002 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV...3yVVKJZ1QRC3FgPGdg9ziGQiYTOxnLFWhLKenbGmCoA%3d%3d 2/12/20,4:48 PM Page 1 of 5 ASTM E330 2002 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15213 R3 Equiv (a) Equivalency of Standards.odf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/20/2017 Date Validated 10/20/2017 Date Pending FBC Approval 10/24/2017 Date Approved 12/12/2017 Summary,of Prod'ucts .-._ _ . . - - ,Go to Page Pagel/2.,0 FL# Model,Number or Name Description. 15213.1 a.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door- Grain/Rustic/Mahogany Series Inswing/Outswing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:No FL15213 R3 Il (a)Inst 15213.1.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.1 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.1.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.2 b.Smooth/Wood Grain/White Wood 6%"Impact"Opaque Fiberglass Single Door with Sidelite . Grain/Rustic/Mahogany Series utilizing"Snap Frame"Glazing-Inswing/Outswing(OX or.XO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15213 R3 II_ )Inst 15213:2.0 Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.2 for Design Pressure Ratings,any EL152 3 R3 AF—(A Eval 152132.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars, 15213.3 c.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing"Snap Frame"Glazing-Inswing/Outswing (OXO- Fiberglass Door Configuration) Limits of Use Installation Instructions - Approved for use in HVHZ: No FL15213 R3 II j)Inst 15213.3.0 Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15213.3 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.3.0 additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.4 d.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing"Lip Lite"Glazing-Inswing/Outswing(OX or XO- Fiberglass Door Configurations) Limits of U'se Installation Instructions Approved.for use in HVHZ:No FL15213 R3 II-(a)Inst 15213.4.p_df Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST•15213.4 for Design Pressure Ratings;any FL15213 R3 E (a)'Eval 15213.4.odf additional use limitations,installation instructions and;product ; Created by Independent Third Party:Yes https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV...3yVVKJZ1QRC3FgPGdg9zlGQiYTOxnLFWhLKenbGmCoA%3d%3d 2/12/20,4:48 PM Page 2 of 5 particulars. 15213.5 e.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing"Lip Lite"Glazing-Inswing/Outswing(OXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FLIS213 R3 II (a)Inst 15213.5, Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:,Yes Design Pressure:N/A Evaluation Reports Other:See INST 15213.5 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.5.0 additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.6 f.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Double Door- Grain/Rustic/Mahogany Series Inswing/Outswing(XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 133 III (a)Inst 15213.6.odf ' - Approved for use outside(HVHZ Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST`15213.6 for Design Pressure Ratings,any _ FL15213 1R3 AE Eva[ 15213.6.E i additional use limitations,installation instructions and product .Created by Independent Third Party:Yes particulars. 15213.7 g.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Double Door with Sidelites Grain/Rustic/Mahogany Series utilizing"Snap Frame"Glazing-Inswing/Outswing(OXXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15213 R3 11 a)Inst 15213.7.0df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15213.7 for Design Pressure Ratings,any FL15213 [U_AE_(a) Eval 15213.7.pddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.8 h.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Double Door with Sidelites Grain/Rustic/Mahogany Series utilizing"Lip Lite"Glazing-Inswing/Outswing(OXXO.- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS213R )Inst 15213.8.odf Approved for use outside HVHZ:.Yes Verified By: Lyndon F-Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15213.8 for Design Pressure Ratings,any FL15213_R3 AF_ ) Eval 15213.8.0df additional use limitations,installation instructions and product. Created by Independent Third Party:Yes particulars. 15213.9 i.Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Single Door utilizing"Snap Grain/Rustic/Mahogany Series Frame"Glazing-Inswing/Outswing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:No FL15213 R3 II (a)Inst 15213.9.p-df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.9 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.9.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.10 j.Smooth/Wood Grain/White Wood 6'8'-'.Non-Impact"Glazed Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series - utilizing"Snap frame'Glazing Inswing/Outswing(OX or;XO- Fiberglass'Door Configurations) Limits of Use Installation Instructions Approved for use.in HVHZ: No FL15213 R3' i- a)Inst 15213.10.0df Approved for use outside HVHZ-Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes, Design Pressure: N/A - Evaluation Reports 'Other:See INST 15213.10 for Design Pressure Ratings,any FL15213 R3 AE Eval 15213.10.0df additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. https://www.floridab6i[ding.org/pr/pr_app_dtl.aspx?param=wGEV...3yVVKJZ1QRC3FgPGdg9z[GQiYTOxnLFWhLKenbGmCoA%3d%3d 2/12/20,4:48 PM Page 3 of 5 15213.11 k.Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing "Snap Frame"Glazing-Inswing/Outswing(OXO- Fiberglass Door Configuration) Limits of Use Installation Instructions - Approved for use in HVHZ:No EL15213 R3 U•( - Inst 15213,11, Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INSTR 15213.11 for Design Pressure Ratings,any FLIS213_ 3_AE_(a) Eval 15213.11.pdf additional.use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.12 I.Smooth/Wood Grain/White•Wood 6'8"Non-Impact"Glazed Fiberglass Double Door utilizing Grain/Rustic/Mahogany Series N "Snap Frame"Glazing-Inswing/Outswing(XX-Configuration) Fiberglass"Door Limits of Use Installation Instructions Approved foruse.'in HVHZ: No FLIV13 R3 11 (a)Inst 15213.12.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure-:N/A Evaluation Reports Other:'See INST 15213.12 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.12.pd additional use limitations,installation instructions and product Created by Independent Third Party:Yes- particulars. 15213.13 m.Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Double Door with Sidelites Grain/Rustic/Mahogany Series N utilizing"Snap Frame"Glazing-Inswing/Outswing (OXXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FLIS213 R3 1(a)Inst 15213.13.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports - Other:See INST 15213.13 for Design Pressure Ratings,any FL15213 R3 AE (a Eval 15213,13.pdf additional use limitations,installation instructions and product Created by Independent Third Party: Yes particulars. 15213.14 n.Smooth/Wood Grain/White Wood 6'8"Ron-Impact"Glazed Fiberglass Single Door utilizing"Lip Grain/Rustic/Mahogany Series A Lite"Glazing Inswing/Outswing(X-Configuration) Fiberglass.Door 'Limits of Use " . Installation Instructions Approved for use in HVHZ:No FL15213 R3 I as Inst 15213.14.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other::See INST 15213.14 for Design Pressure Ratings,any 171-15213 R3 AE_(a) Eval 15213.14:odf, additional use limitations,installation instructions and product 'Created by Independent Third Party:Yes; particulars. 15213.15 0. Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Single Door with,Sidelite Grain/Rustic/Mahogany Series N utilizing"Lip Lite"Glazing-Inswing/Outswing(OX or XO- Fiberglass Door Configurations) - Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3_ Inst 15213.15.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.15 for Design Pressure Ratings,any FL15213 R.3 AE_(a) EvalEval 15213.15,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.16 p.Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series N utilizing":Lip Lite"Glazing-Inswing/Outswing(OXO- Fiberglass Door. Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a)Inst 15213.16.pdf Approved for use outside HVHZ:Yes Verified'By: Lyndon F. Schmidt, P.E.43409 Impact-Resistant:No -Created by Independent Third Party:Yes Dtlesign,Pressure: N/A Evaluation Reports Other:See INST 15213.16 for Design Pressure Ratings,any FLIS213_R33 AE (a)-Eval 15213.16.04 additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.,17 q.Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Double Door utilizing"Lip Grain/Rustic/Mahogany Series N Lite"Glazing-Inswing/Outswing(XX-Configuration) https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEV...3yVVKJZ1QRC3FgPGdg9zlGQiYTOxnLFWhLKenbGmCoA%3d%3d 2/12/20,4:48 PM Page 4 of 5 Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:No FL15213 R3 II (aJ Inst 15213.17.pd Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15213.17 for Design Pressure Ratings,any FL15213 R3 AE (a) Eval 15213.17.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.18 r.Smooth/Wood Grain/White Wood 6'8"Non-Impact"Glazed Fiberglass Double Door with Sidelites Grain/Rustic/Mahogany Series N utilizing"Lip Lite"Glazing-Inswing/Outswing(OXXO Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213.R3 Inst 15213.18.odf Approved.for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:.No Created by Independent Third Partys Yes Design Pressure:N/A Evaluation Reports Other:INST 15213.18 for Design Pressure Ratings,any FL15213 R3_AE_(.a)Eval 15213.18.odf additional-use limitations,installation instructions and product Created by Independent Third Party:Yes cu ars. 15213.19 s.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door- Grain/Rustic/Mahogany Series N Inswing/Outswing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL1521333_11 a)Inst 15213.19.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:INST 15213.19 for Design,Pressure Ratings,any FLIS213 R3 AE (a) Eval 15213.19.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15213.20 t Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series N utilizing"Snap Frame"Glazing.-Inswing/Outswing(OX or XO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3_LL(a)Inst 15213.20.odf _ Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure::N/A Evaluation Reports Other:INST 15213.20 for Design'Pressure Ratings,any FL15213 R3 AE Eval 15213.20.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. ,Go to Page d Page 1/'2 0 0 0 Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.CoRvriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: =- Credit Card. Safe . https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV...3yVVKJZ1QRC3FgPGdg9zlGQiYTOxnLFWhLKenbGmCoA%3d%3d 2/12/20,4:48 PM Page 5 of 5 plastpro =�.: , M ,a.;zL1 =0 to v4=? n 5200 W. CENTURY BLVD. 'ai -T, i om LOS ANGELES, CA 90045 'f,>' .., 5yti� a z ro mf r ' 37.50"MAX.OVERALL !t tit+s o n m z° Smooth J Wood Grain/ White Wood Grain FRAMEWtDTH m O - Rustic/Mahogany ~ a 4 Z �Z. V N u� J., Series � Series N Fiberglass Door Eoz INSWING/OUTSWING a nW "IMPACT" z z yr CDo O �z a o zQ o GENERAL NOTES w m �c E: ¢.0 Q G�N W� 1. This product has been evaluated and is in compliance with the 6th Edition(2017) J J a Florida Building Code(FBC)structural requirements excluding the"High Velocity p c Hurricane Zone"(HVHZ). m o w o p O �� a 2. Product anchors shall be as listed and spaced as shown on details.Anchor S embedment to base material shall be beyond wall dressing or stucco. m 0 3. When used in areas requiring wind bome debris protection this product complies a a With FBC Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in w ASTM Ell 996 and FBC Sections 1609.1.2.2&R301.2.1.2.1. 0 0 ww � 4. For 2x stud framing construction,anchoring of these units shall be the some as that shown for 2x buck masonry construction. N o� ,g 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a,licensed engineer or registered architect. o 0 CL i c TABLE OF CONTENTS � SNEEtt# DESCRlPTtON w i� � m H a 1 3 I Typical elevation,design pressures,&general notes M qX o Cz DESIGN PRESSURE 5 2 o N 2 Door panel detalls FRAME �,. w z oD 3 Horizontoicrosssections SWING DIMENSION POSITIVE NEGATIVE- ons 02�tg�i2 Z 4 Vertical cross sections 5 Buck and frame anchorin 2X buck mason construction INSWING 37.50"x 98.00" + soar N.T.S. o s" g ct 65.0 -70.0 DWG.BY. 2 6 Frame anchoring-1X buck masonry construction 7 1 Bill of materials&components OUTSWING 37.50"x 96.50" +65.0 -65.0 DNN.BY, LF5 3 DRAWING NO.: 'a FL—15213.79 0 ll10!ents\Pl.as'.pra.In.KUM,'N"Niv.-ri-.__._. 95.25"MAX.DOOR PANEL HEIGHT [Ell 0 -0 0 go T =A oa - 0 0011 0 70 mo _T iq. 0 0 0 rr, 1.13" 1.13" en ?L RE G) N r, rn 9 Pc ] 7 rn rn a -4 in 0 M 22 No.4l-'V-- October 19,2017 A T PRODUCT: Doc Propend Documents Schmidt'-%-, Lyndon N. P.E. No ;S PLASTPRO INC. 4,34-09 1�1_10111101mlhl IN Ln 1. z FIBERGLASS DOOR 2 TWF9/17 UPDATE TO 6TH ED. (2U17) FBC PART OR ASSEMBLY. BUILM.-3 001­�ULTAX.7Z, ING. W —1 0-4 2_2�-15—UPDATE TO 5TH EO. (2074)FBC JK Iv 7 DOOR PANEL DETAILS Ylv P.O. Box 230, Valrrco, FL 33595 NO DATE BY Phone No.: 813.659.9197 REVISIONS I FSPE CA No. 91313 Q 2012 R.W.BUILDING CONSULTANTS INC. R\Oientz\r;,;+...,u;,rE:.K.,a._."^J:-F:,�4.F.,x•9__ .;-_._�iFt4.G:1s r;�d _<�.-,-_}..�- �.n.__��rr_D:e_��_ __S;L3;7?_-i:�_'-'='i31._..._ �'++ F A �3 m z W v w� a07_ r — On 23CD O ,o C) y V W o .Oy C, � o Z m 0 lO 4.r Q V W W W N O D Z m A A O ww A N O m m o 0 0 Q A V p W N V W N () N oc0= C Gnu' .� — 0 N p ti V T ° v - 77 O to m3 n -- m G/ No.43409 October 19,2017 PRODUCT: Document.P-p—d ' FYORID�;•�'I7\°��� r m Lyndon F. Schmidt /�•'' ''•••••.. Rc P.E. No. 43409 L4 / II`Fts Io z N FleEss�v '����Alr4l.4 �\ 2 70 79�17 UiwirE TO G r.ER (201ij FGt: L('S :] PART 02 Aas�l ac:: � eu,:�r,s C0lZUL`IA; 3, ILS. jj N fn 1 04 22 15 UPDATE TO 5TH ED. (2074) FBC JK HORIZONTAL CROSS SECTIONS P.O. Box 230, Valrico, FL 33595 V N NO DATE BY Phone No.: 813.659.9197 REVISIONS FBPE CA No. 9813 ®2012 R.W.BU1La1Na CONSULTANTS INC. RAClientANas!r..L...,..,...rNM ,..ti__A; = -"-' Z s-' '_: ::_ -:.-y,- -� is 17; Z _..-..a-Ge:;�3^:•' .--�..�-;�I-,�,tl r.,.._:-•-r_-. _Ire :.�.: -0:.?s -.rLl�'?� 1-1/4"MIN. —'r EMB.(TYR) I T 114IM v a m M a n m A o 0 A-• Om a o 6C ° v 70 0 C) •.�, „ M0 f1 CD 0 Io OAAO 0 H P 7p yN O y 5•y Z z T Z y o ... IM =:1 IM Ot V ' I0 �:a I0 e° p O ° 0.15" C'SINK--I a r p. I-1/4 MIN. EMB.(TYP.) 1-1/4"MIN. rn EMB.(TYP.) a is � ,,•. a W A M O O n v X r T C A AA x �y o --I T T P O N .Z_7 -_q A ' Z rn o 10 . n A U 0 C' p.a lJ T y v NO De Z o p a fZ o 22 1-1/4"MIN. 0 EMB. m ``��tN111lrrrrh/i ��. ..:Sc / No.43405• October 19,2017` y�v x cDFi PRODUCT: Documenta Prepared By: r ,F•, Lyndon F. Schmidt �� �'•..OR..... li' o Z\ FIBERGLASS DOOR P.E. No. 43409 y m 2 to t9 n UPDATE TO 6TH E0. (2017) FBG LFS PART OR ASSEMBLY: BUILDIt:C CO NSULTAt S, INC. IW •T1 � t�\ 1 04 22 15 UPDATE 70 5TH ED. (2014) FBC JK w p-O- Boz 230, Volrieo, FL 33595 � 10 ro NO DATE BY VERTICAL CROSS SECTIONS Phone No.: 813.659.9197 REVISIONS I I FBPE C.A. No. 9813 0201 2 R.W.BUILDING CDNBUL—NTS INC. ��� to t �gv, J"_zv ro oro (,�.0 if * .On �N 7 z° rc:Q`l o m , TYP.HEAD No OUvj zo`` TYP.HEAD& $ &JAMBS JAMBS ° o zc MASONRY N MASONRY mu wOPENING OPENING g a 9 oa n ^; m cram LL J O E oz c 43 2. �5 x 3 N4 2w w to FRAME zv N Z NV • K Erb � zO ?o c O cn 0 2X BUCK-\ wu .fir — ! Z am" a Fn _ zo 2X BUCK o YCXi NEn a a mm o F rT m s �����j•J TYP.Q SILL I' 1 •° a U a o 0 En . w w N ° Ln BUCKANCHORING HINGE JAMB FRAMEANCHORING STRIKEJAMB o 0 CONCRETE ANCHOR NOTES: Masonry 2X buck construction a1.Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjolnts. IL 6 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to n f ` maintain the min.edge distance to moriarjoinfs,additional concrete anchors 9 — w = a may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. M 28 L ^N a 3 Concrete anchor table :MIN'-; MIN CLEARANCE z "ANCHOR ANCHOR MIN o TYPE SIZE EMBEDMEIdi TOMASONRY TOADJACEN7 ' ' ° z o a EDGE.. ANCHOR .. ❑ onrE:02/16/12 i TAPCON® 1/4" 1-1/4" 2" 4" M 2� owc BY..KAM JK ULTRACON m' ELCO ® I/4" 1.1/4" 1" 4" 1 cHx er: LFS 3 a WOOD SCREW INSTALLATION NOTES: oanwwc No.: a 1.Maintain a minimum 5/8"edge distance,I"end distance,&1"o.c.spacing of LATCH&DEADBOLT DETAIL HINGE•DETAIL FL-15213.19 =' wood screws to prevent the splitting of wood. SHEEP S of 7 N .... 1%elk Ln -� -$ 3 g D•J-ci (J TYP.HEAD& �/ll* 11� �`71 IO o a m 0 G " o ❑ r MASONRY J SBS z Z.4cdi 27 OPENING ori a y g 9 o t a b 3 maa� c a `m 9 a N o Z o ~9 LATCH S DEADBOLT DETAIL E O 'u c h1 n° �To: d N FRAME W mo z 9 H o 0 10 p. Z U a w � O 1XBUCKg v. 4 r D= a a F '>m HINGE DETAIL o I TYP.@ SILL LL N N N ' "•' 8 N U1 CONCRETE ANCHOR NOTES: I.Concrete anchor locations at the comers may be adjusted to maintain the min. omo edge distance tomortarjoints. HINGE JAMB FRAMEANCHORING STRIKE JAMB a 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to Masonry 1X buck construction ¢a maintain the min.edge distance to mortarjoints,additional concrete anchors 8 may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. >> ? d 3 Concrete anchor table ° c MIN CLEARANCE 'MIN CLEARANCE a N Q r ¢ ANCHOR ANCHOR M1N TO MASONRY i0 ADJACENT g TYPE 31ZE EMBEDML Ni J L. rz EDGE ANCHOR. N O o :. ITW z TAPCON® 1/4" 1.1/4" 2" 4" �� z a 02 16/12 i ELCO Ste: N.T.S. ° ULTRACONm 1/4" 1.1/4" 1" 4" SCA . JK m' 1TW ® 3/16" 1.1/4° 3° 1.1/2" cHw BY. LFS 3 TAPCON WOOD SCREW INSTALLATION NOTES: rc d DRAWING NO.: 1.Maintain a m(nimum 5/8"edge distance,I"end distance,&1"o.c.spacing of FL-15213.19 N wood screws to prevent the splitting of wood. SHS—L OF 7 w N 4.56' p`: n BILL OF MATERIALS L o =U 3 " * O:Z REM DESCRIPTION MATERIAL v; z r`,i. n A 1X BUCK SG>=0.55 WOODL �i ,�,4)% r �N CO ^ B 2X BUCK SG>=0.55 WOOD �•O,''••.... •• •� v��,> C 1/4"MAX.SHIM SPACE 2.44' Lo)I ��'��rrr*1��� ` L N m z D 1/4!'X 2 3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL ^ a a 0 x z MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI HEAD&SIDE e E m z m°m U E CONCRETE 21 N r c w 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 Poly fiberjamb OS a$g m o Oa. F 114'X 2.3/4"PFH ITW CONCRETE SCREW STEEL m a 'm d a PH 3116'X 3-1/4"PFH ITW CONCRETE SCREW STEEL rn a c i 1/4"x 3-1/4"PFH ITW CONCRETE SCREW STEEL ~ 4.56"�I o T�1/4"X 2-1/4"PFH TTW CONCRETE SCREW STEEL1/4"X 3-3/4"PFH ITW CONCRETE SCREW STEEL #10 X 2-1/2"PFH WOOD SCREW 1.15'MIN.EMBEDMENT STEEL #9 X 2-1/4"PFH WOOD SCREW STEEL FORCE 5 WEATHER STRIPPING BY ENDURA FOAM + pn!!g' '30 o Z 8 COMPRESSION WEATHER STRIP OLON 650 BY SCHLEGEL FOAM o y ¢z 9 4'X 4"BUTT HINGE STEEL 20 HEAD&SIDE pLr" a 10 #9 X 1"PFH WOOD SCREW STEEL Jamb w o0 11 #9 X 3/4"PFH WOOD SCREW STEEL 5.63" ° �Q j"7 17 KWIKSETKEYEDENTRY-SIGNATURESERIES STEEL �I 'm 18 KWIKSETDEADBOLT-SIGNATURESERIES 780 STEEL l 20 FINGER JOINTED PINE FRAME,HEAD&HINGE JAMBS WOOD 21 POLYFIBER JAMB COMP./VINYL a a 27 LATCH STRIKE PLATE STEEL m 28 DEADBOLT PLATE STEEL 0 30 INSWING VINYL DOOR BOTTOM SWEEP BY ENDURA VINYL 31 OUTSWING BUMP THRESHOLD ALUM./WOOD 33 ADJUSTABLE INSWING THRESHOLD 32 VINYL DOOR BOTTOM SWEEP#3628 BY HOLM.IND. VINYL 33 INSWING ADJUSTABLE THRESHOLD BY ENDURA ALUM./WOOD 34 INSWING ADJUSTABLE ALUMINUM THRESHOLD BY DLP ALUM./WOOD4 56 g fv Ln 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS S 41 DOOR SKIN(MIN.0.086"THICK) FIBERGLASS cl R o 0 42 TOP RAIL CELLULAR PVC 43 LATCH&HINGE STILE EDGE CELLULAR PVC o 0 44 LATCH AND HINGE STILE SUPPORT WOOD >Q. z 45 BOTTOM RAIL CELLULAR PVC n ADJUSTABLE INSWING THRESHOLD 46 POLYURETHANE FOAM BY NAN YA POLYURETHANE c N a 47 STILE REINFORCEMENT STEEL 0 g 4.68" rz 48 REINFORCEMENT RETAINING SCREW NYLON p o 0 Z N Z a r7 DAM 02/16/12 z 1 scvE N.T.S. ° DWO.BY: JK m' E I CHK.BY: LFS 3 �1 OUTSWING BUMP THRESHOLD DRAYRNG NO.: FL-75213.19 " a SHEET 7 Of 7 N O 0