Loading...
HomeMy WebLinkAboutProduct Approval - r t En" �.'"".�a.p �'s�s •^*�Er'c�`' �ii�Y ��w$r� +�t r `�" �.+��"U�'G?� �f�.: ++ i •• + - BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Pacts Publications i Contact Us SCIS Site Map i Unks Search I Florida �. :z ProduetApproval Xf USER:Public User d r Product A proval Menu>Product or Aopiicatlon Search>Application List>Applicatlon Detail 4"Fv`tt `� RECEIVED x; FL# FL9777-R11 Application Type Revision FEB ?n„9 Code Version 2017 Application Status Approved ST. Lucie County, Permitting Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler 0.2— 0 greg.keeler@owenscoming.com Technical Representative REVIEWED FOR Address/Phone/Email CODE COMPLIANCE Quality Assurance Representative ST® L U C 1 E COUNTY Address/Phone/Email ®CCt C` reCategory Roofing � le C Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R.Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. { Validation Checklist-Hardcopy Received Certificate of Independence FL9777 R11 COI OCR14002 8a 2017 FBC Evaluation Reoort Weatherlock Non-HVHZ.t�df Referenced Standard and Year(of Standard) Rondard Year ASTM D 1970 2015 ASTM D 226 2009 ASTM G'155 2005 TAS 103 1995 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method I Option D Date Submitted 10/11/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Surnm9ty-of Products FL# Modelt Number or Name Description 9777.1 Weatherlock G Weatherproofing Underlayment Umlts of use Installation Instructions Approved for use In HVHZ:No FL9777 811 11 OM4002.8a 2017 FBC Evaluation R4Ek Approved for use outside HVHZ.-Yes Watheriork Non-HVHZ.pd Impact Resistant., N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 1111 AE'.QCR140Q2,8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ,pd , Created by Independent Third Party:Yes 9777.2 WeatherLock G(High Tear) Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use In HVHZ.No FL9777 R11 II QCR14002.8a 2017 EBC Evaluation Re Approved for use outside HVIiZ-.Yes Votherlock Non-HVH2,p-4 Impact Resistant,N/A Verified By:Zachary R.Priest PE-74021 Design Pressure, N/A Created by Independent Third Party:Yes Other.See evaluation report for limits of use. Evaluation Reports FL9777 R11-AE OC814002.8a 2017 FBC Evaluation Rgport Weatherlock Non-HVHZ.pgf Created by Independent Third Patty:Yes 9777.3 W=eather1ock MAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use In HVHZ.Yes FL9777 R11 II OCRI4002,.8b 2-017 F.8C Evaluation Rep= Approved for use outside HVHZ*No Weatherlock HVHZ.pdf - Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure* N/A Created by Independent Third Party:Yes Other.,See evaluation report for limits of use. Evaluation Reports EL9777 1111 AE-.QCR 14002-8b 2017 FBC Evaluation RepW Val Created by Independent Third Party:Yes 9777.4 --iWeatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ;No FL92Z7 11*11. 11 -OCR14002.8a 2017 FBC Evaluation Report Approved for use outside HVHZ.Yes Weatherlock Non-HVHZ,12 Impact Resistant,N/A Verified By.,Zachary R.Priest 74021 Design Pressure, N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE-OCR14-002.8a 2017 FBC Evaluation Refit. W-gatheriock Non-LiVHZ.pdf Created by Independent Third Party:Yes 9777.5 Weatheriock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ;No FL 1111 11 OCRI4002.8a 2017 E11C Evaluation Rept Approved for use outside HVHZ".Yes Weatherlock Nk3nz-HYJJ7_.p-df Impact Resistant.,N/A Verified By:Zachary R.PrlestPE-74021 Design Pressure.,N/A Created by Independent Third Party:Yes Other;See evaluation report for limits of use. Evaluation Reports FL9777 R11 AF OCRI4002.8sl 2017 FBC Evaluation kepaCt Weatherlock Non:bYbZpAf Created by Independent Third Party:Yes 9777.6 WeatherLock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL9777 Ril 11 0 814002 8b 2017 FBC Evaluation Repo tr Approved for use outside HVHZ:No Weatherlock HVt4Z.pdf Impact Resistante NIA Verified By:Zachary R.Priest PE-74021 Design Pressure.,N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports Fo 77 R11 AE OCRI40018b 2017 FSC Evaluation Reg= Wgatherlock HYHZp-df Party:Yes Endependent Third Pa 9777.7 Weathercock Specialty Tile&Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use In HVHZ:No P0777 Rjj 11 9014002,ft-2017 FBC Evalu Approved for use outside HVHZ*Yes —Weatherlock NoR:ftV—H7.p_4f vm -9T Pries'74021 Party: Zachary R�t Third a .Yes e 140 a E n R rt Z P " - :_a Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure: +0/-142.5 Created by Independent Party;Yes Other.,See evaluation report for limits of use. Evaluation Reports IF 0777 P11 AE OCR1400.8a 2017 FBC Eyoluation Created r t y Third party. ea ad b Independentrd Yes ED ED Contact Us::2601 Blair Stone Road,Tallahassee FI,32399 Phone,850487,-2824 The State of Florida is an WEED employer. tate of Florida.:;Privacy Statement:: Refund Statement Under Florida low,emall addresses are public records.If you do not want your e-map address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487,1395.*Pursuant to Section 455,275(1), Morlda statutes,effective October 1,2012,licensees licensed under chapter 45s.Rs.must provide the Department with an email address if they have one.The arrialls provided may be used for official communication with the licensee,However email addresses are public record.If you do not wish to supply a Personal address,please Provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 45S,FS.,please click h1a, product Approval Accepts: Credit Card Safe i 8 Certificate of Authorization No. 29824 z 17520 Edinburgh Drive CREEK Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480.3421 EVALUATION REPORT FLORIDA BUILDING CODE,C EDITION(2017) Manufacturer. OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2097 1 Owens Corning Parkway Toledo,OH 43657 (800)438-7465 www.owenscorni nq;com Manufacturing Location: Brentwood,NH Houston,TX Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Undedayments Code Sections: 1504.3.1,1507.1.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) NEI-039412-01 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) NEI-042-02-01 REV2 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) NEI-045.02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) NEI-053-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) NEI-053.02-01, ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) NEI-093-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies(TST5878) OGF-237-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-253-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-272-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) OCF-296-02-02 ICC-ES AC 188' 2012 ICC-ES AC 48 2012 PRI Construction Materiels Technologies(TST5878) OCF-297-02-01.1 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-318-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-320-02-01 TAS 103 1995 PRI Construction Materials technologies(TST5878) OCF-320-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) OCF-321-02.01 ASTM D 1623 2009 PRI Construction Materials Technologies(TST5878) OCF-322-02-01 UL 1897 2012 PRi Construction Materials Technologies(TST5878) OCF-355-02-01 UL 1897 2012 'Determined to be equivalent to ASTM D 226-09,Type I and 11 OCR14002.8a FL9777-R11 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-0. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. OWENS CORNING ROOFING AND ASPHALT LLC CREEK Weal erLockO Self-Seating fee&Water Barriers TECHNICAL SERVICES,LLC PRoDucT DEscRIPTION AND LIMITS OF USE WeatherLock@ G WeatherLockS G is an ASTM D 1970 self-adhesive underlayment constructed from SBS (Brentwood,NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq.rolls with nominal dimensions of 3-ft x 66.7-ft. Weatherl-ockO G is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure an the roof deck shall be limited to a maximum 30 days. WeatherLock@ Mat WeatherLockS Mat is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood,NH or SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 11- Houston, 7)Q sq.rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@) Mat Is permitted to be used as prescribed In FBG Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ Metal WeatherLock@)Metal is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood,NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock4l) WeatherLockS Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment Specialty rile&Metal constructed from SBS modified asphalt and surfaced with a non-woven polyester fabric. (Brentwood, IVH or The product is supplied In 2.14 sq.rolls with nominal dimensions of 3 f x 71.3 ft. Houston, 7X) Weatherl-ockS Specialty Tile & Metal is permitted to be used as prescribed in FBC Section 1507.1.1. WeatherLock@) Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP Adhesives and Sealants, Inc.)or TILE BC W'm Roof Tile Adhesive(The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. WeatherLock@ G(High WeatherLock@ G(High Tear)is a self-adhered,underlayment used as an alternative.to Tear) ASTM D 226,Type I or Type II roofing felt and ASTM D 1970 self-adhering polymer (Houston, TX) modified bitumen underlayment. The underlayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product Is supplied with a nominal thickness of 60 mils in 1,95-sq rolls with nominal dimensions of 3-ft x 65-ft. WeatherLockg G (High Tear)'is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. OCRI4002.8a FL9777-R11 Page 2 of 4 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein, OWENS CORNING ROOFING AND ASPHALT LLC CREEK WeaUwrLock@ Self-Sealing Ice&Water Barriers TECHNICAL SERVICER,LLC ~ PROAt)CT APPLICATION Min.Roof Slope: . 2:92 In accordance with the FBC Application: All underlayments shall be installed in accordance with the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the undedayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The undedayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck.The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3"side laps and minimum 6"end laps staggered min.6-it.from preceding course. Additionally,if applying WeatherLock®Specialty Tile & Metal, end laps shall be primed with ASTM D 41 primer or seated with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It Is permissible to back nail the underlayment 12-Inches on-center as needed(nails shall be Installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Additionally;WeatherLockg Specialty Tile& Metal shall be back nailed when installed on roof slopes greater than 3:12. Min.Application 40°F; Contact the manufacturer when installing at temperatures below the minimum Temperature: - application temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Seaton 1.504.9. UnderiMent System No.1-WeatherLock Specialty Tile&Metal Qniv Roof Deck: Min. 15132-inch COX plywood attached to wood supports spaced a maximum 24"o.c. t Underlayment: WeatherLock(& Specialty Tile & Metal shall be applied In accordance with manufacturer's installation Instructions to the fastened deck and backnailed along the selvage with minimum 12ga., 1-114-inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1-518-4nch 0 tin caps spaced '12" o.c. The applied undedayment shall be rolled with a minimum 751b steel roller Immediately following application. Maximum Design -142.5 psf Pressure: OCR14002.8a FL9777-Rl l Page 3 of 4 This evaluation report Is provided for State of Florida product approval under Rule 81G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein.. OWENS CORNING ROOFING AND ASPHALT LLC CREEK Weathedock@ Self-Sealing Ice&Water Barriers TECHNICAL SERVICES, LLC GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation., 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be Installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC:product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the-design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed In this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer., P i� ....4 ' 2017.10.11 No 74021 09:06:29 0. X X -0400 �P_ STATE OF QJ 0 z Zachary R.Priest, P.E. N Florida Registration No.74021 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest In any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest, P.E.does not have,nor will acquire,a financial Interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14002.8a FL9777-R11 -Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 6I020-3. The manufacturer shall notify GREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein.