Loading...
HomeMy WebLinkAboutProduct Approval (2) BCIS Home Log In ! User Registration Hot Topic Submit Surcharge Stats&Facts ' PublicationsG Contact Us SCIS Site Map ' Links i Search i F! rich Product Approval rL4'r USER:Public User �i Product Approval Menu>Product or Application Search>ggplicatlon List>Application Detail s, RECEIVE® g u FL# FL17678-R6 : -;' 4w, Application Type Revision FEB 10 9 Code Version 2017 Application Status Approved ST, Lum c13wntyj Permitting Comments Archived Product Manufacturer Drexel Metals,Inc. Address/Phone/Email 204 Railroad Drive I502)3,PA 511 REVIEWED FOR (502)303-1511 jshumate@drexmet DE COMPLIANCE Authorized Signature Jason Shumate ID 1�s1� jshumate@drexmetc§m�° LUC° ��eeOUNTY BOCC Technical Representative Address/Phone/Emali Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R.Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity Architectural Testing,Inc.,an Intertek Company Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL17678 R6 C07 DRX15001.6 2017 FBC Evaluation Report NonHVHZ Referenced Standard and Year(of Standard) Standard Year ASTM B117 2016 ASTM G 155 2005 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 580 2006 UL1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method I Option D Date Submitted 10/09/2018 Date Validated 10/09/2018 Date Pending FBC Approval 10/21/2018 Date Approved I2/11/2018 Summary of Products FL# Model,Number or Name Description 17678.1 Drexel Metal Roofing Systems DMC 100N5,DMC 15051,DMC 15OSS,DMC 1755,DMC 200S, DMC 450,DMC SV&DMC Corrugated Limits of Use Installation Instructions Approved for use In HVHZ:No F1767 R6 II DRX15001,6 2017 FBC Evaluation Repad Approved for use outside HVHZ,Yes NonHY-H-Z final.pdf Impact Resistant:N/A Verified By: Zachary R.Priest PE-74021 Design Pressure:+0/-180 Created by Independent Third Party:Yes Other.See evaluation report for limits of use Evaluation Reports FL17678 R6 AF DRX15091-6 2017 FBC Evaluation Regart NonHVHZ finalpdf Created by independent Third Party:Yes COntaLl Us 2601Blair Stone Roo The State or Florida Is an AA/EEG employer..Cc ght.-WQ2013 State Of Mrida.::EdW_SjgWj=1;ACCessIbliny Statemrnt::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a publIL-records,request do not Send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.if you have any questions,please contact 850.487,1399.*Pursuant to Section 455,275(1), Florida Statutes,effective October 1,2012,licensees licensed under chapter 455,F.s.must provide the Department with an email address If they have one.The ernalls provided may be used for official communication with the license*.However email addresses are public record.If you do not wish to supply a personal address,please .provide the Department with an email address which can be made available to the public To determine If you are a licensee under Chapter 455,ES,please click DW—. Product Approval Accepts: Credit Card Safe Certificate of Authorization No.29824 CREEK 17520 Edinburgh Dr Tampa,FL 33647 TECHNICAL SERvicEs, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6'EDITION(2017) Manufacturer. DREXEL METALS,INC, issued October 9,2098 1234 Gardiner Lane Louisville, KY40213 (502)716-7143 www.drexmet.com Manufacturing: Drexel Metals Association of Regional Manufacturers(DM-ARM) Quality Assurance: Architectural Testing,[no,(QUA1844) SCOPE Category. Roofing Subcategory. Metal Roofing Code Sections: 1604.3 Properties: Wind Resistance REFERENCES Enti Report No. Standard Year Architectural Testing(TST1558) 66840,02-122-18 TAS 100 1995 Architectural Testing(TST1558) 68389.01-122-44 UL 560 2006 Architectural Testing(TST1558) 58459,01-122-44 UL 580 2006 Architectural Testing(TST1558) 58461.01-122-44 TAS 125 2003 Architectural Testing(TST1558) 82776.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing(TST1558) 82784.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing(TSTI 558) 83296.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing,Inc(an Intertek Company)(TST1527) H3245.01-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) H9058.02-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) 1-1905&01-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) 13391.01-450-44 UL 680 2006 Force Engineering&Testing(TST5328) 178-0054T-12 UL 580 2006 UL 2012 Force Engineering&Testing(TST5328) 178-0055T-12 UL 5801897 2006 UL 1897 2012 Hurricane Test Laboratory(TST1527) 0287-0209-07 TAS 125 2003 Hurricane Test Laboratory(TST1 627) 0287-0308-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0311-07 TAS 125 2003 Hurricane Test Laboratory(TST1 627) 0287-0313-07 TAS 1215 2003 Hurricane Test Laboratory(TST1527) 0287-0512-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0706-07 TAS 125 2003 PRI Construction Materials Technologies(TST5878) VLS-005-02-DI ASTM B 117 2016 TAS 110 2000 PRI Construction Materials Technologies(TST5878) VLS-004-02-DI ASTM G 155 2005a • PRI Construction Materials Technologies(TST5878) DMC-004-02-01 TAS110 2000 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-005-02-01 TAS 125 2003 PRi Construction Materials Technologies(TST5878) DMC-006-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-007-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-008-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-009-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-014-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-016-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-017-02-01 Rev 1 UL 580 2006 UL 1897 2012 DRX15001.6 FL17678-R6 Page i of 5 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty,installation,recommended use,or other product attributes that are not specifically addressed heroin. i CREEKDREXEL METALS,INC. j� Metal Roofing TECHNICAL SERVICES,LLC ti Regort NoStandard Year PRI Construction Matelots Technologies(TST5878) DMC-018-02-01 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-024-02-01 UL 580 2006 UL 1897_ 2012 PRF Construction Materials Technologies(TST5878) DMC-033-02-01.1 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-037-02-01 UL 580 2006 UL 1897 2012 PRt Construction Materials Technologies(TST5878) DMC-037-02-02 UL 580 2006 UL 1897. 2012 PRI Construction Materials Technologies(TST5878) DMC-036.02-01 UL 580 2006 UL 1897 2012 PRODUCT DEsCRIOTION DMC 100NS Profile: 1 in.sna tock seam;Max.16 in.coverage Description: Non-structural,snap lock standing seam roof panel with Integral perorated nail Material: Min,24 ga.Fluropon@ coated ASTM A792 AZ50,or ASTM A653 G90;FY in.50 ksi; Shall conform wifh FBC Section 1507.4.3 ,C DMC 150SL Profile: 1.5 in.snap Lock seam;Max.16 in.cov®rage Description: Non-structural,snap lock standing seam roof panel Material: Min.24 ga.FluroponO coated ASTM A792 AZ50,or ASTM A653 G90;Fermin.50 ksi; Shall conform with FBC Section 1507.4.3 _ T^ 4 DRX15001.6 FL17678-R6 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20a The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. DREXEL METALS,INC. CREEK Metal Roofing TECHNICAL SERVICES,LLC DMC 15OSS Profile: 1.5 in.mechanical seam;Max 16 in.coverage Description: Non-structural,mechanical lock standing seam roof panel Material: Min.6.032 in.Fluropon@ coated ASTM B209 aluminum;Fy=min. 16 ksi; Shall conform with FBC Section 1507.4.3 Min.24 ga.Fluropon@ coated ASTM A792 AZ50,or ASTM A653 G90;Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 1" 3. 2F a —7 A& -T Material: Min.0.027 in.Zinc;Fy=min. 16 hall conform with FBC Section 1507,43 16.7" DMC 175S Profile: 1.75 in.snap look seam;Max. 18 in.coverage Description: Non-structural,snap lock ttand!aseam roof panel Material: Min.0,032 in.Fluropon@ coated ASTM B209 aluminum;Fy=min.24 ksi; Shall conform with FBC Section 1507.4.3 Min.0.0404nch FluroponS coated ASTM 8209 aluminum(Fy=min.20 ksi); Shall conform with FBC Section 1507.4.3 Min.24 ga.Fluropon@ coated ASTM A792 AZ50,or ASTM A653 G90;FY=min.50 ksi; Shall conform with FBC Section 1507.4.3 1r DMC 2005 Profile: 2 in.mechanical seam;Max.16 in,coverage Description: Non-structural,mechanical lock standing seam roof-panel Material; Min.0.040 in.Fluropon@ coated ASTM B209 aluminum;Fy=min.20 ksi; Shall conform with FBC Section 1507.4.3 Min.24 ga, Fluropon@ coated ASTM A792 AZ50, ASTM A653 G90;Fes,=min.50 ksi; Shall conform with FBC Section 1507.4.3 -T 2" 16" DRX15001.6 FL17678-R6 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid, This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. C. y' DREEL METALS,INCREEK Metal Roofing TECHNICAL SERVICES,LLC DMC 450 Profile: 1.5 in.snap lock seam;Max.16 in.coverage Description: Non-structural,snap look standing se_a_m roof panel with concealed clip Material: Min.24 ga.ASTM A792 or ASTM A653; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 Min.0.032 in.Fluropon®coated ASTM B209 aluminum;Fy=min.24 ksi; Shall conform with FBC Section 1507.4.3 1 z" 18" DMC 5V Profile: 318 in.ribs; Min.21 in.,Max.24 in.coverage _ Description: Non-structural,through fastened roof panel Material: Min.26 ga.Fluropon®coated ASTM A792 or ASTM A653 G90;Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 Min.0.032 in.Fluropon®coated ASTM 8209 aluminum;Fy=min.23 ksi; Shall conform with FBC Section 1507.4.3___ 21'up to 24"Coverage _l. 8� DMC Profile: _ 112 in.corrugation;21 in.coverage Corrugated Description: Non-structural,through fastened roof panel Material: Min.26 ga.Fluropon®coated ASTM A792 or ASTM A653 G90; Fy=min.40 ksi; Shall conform with_FBC Section 1507.4.3 Min.0.032 in.Fluropon®dated ASTM 8209 aluminum',Fy=min. 19 ksi; Shall conform with FBC Section 1507.4,3 h ++ 1 7 z'- DRX15001.6 FL17678-R6 Page 4 of 5 This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. METALS,INC. CREEK DREXEL Metal Roofing TF-CH' SF-Rvilms,LLC UwATioNs 1. Fire classification is not within the scope of this evaluation. 2. This report Is not for use in the HVHZ. 3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4. Roof slope shall be in accordance with FBC Section 1507.4.2. 5. Reroofing shall be in accordance with FBG Section 1511. 6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant Installation detail shall prevail. 7. All products listed in this report shall be manufactured under a quality assurance program In compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. R P 9.. 2018.10.09 11 :21 :46 No 74021 -0 -0400 ►';0 STATE OF 40 0. 0-AN 40 Zachary R.Priest,P.E. Florida RegistratNo. AL O 'WN illI11100" Organizaton No.ion ANE964174021 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will It acquire,a financial Interest in any company manufacturing or distributing products under this evaluation.. GREEK Technical Services,LLC Is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest, P.E.does not have,nor will acquire,a financial Interest In any company manufacturing or distributing products under this evaluation. Zachary R;Priest,P.E.does not have,nor will acquire,a financial Interest In any other entity Involved in the approval process of the product. APPENDICES 1) APPENDIX A—Installation(12 pages) 2) APPENDIX B—Approved Roof Systems(8 pages) 3) APPENDIX C—Design Wind Loads(4 pages) DRX15001.6 FL17678-R6 Page 5 of 5 This evaluation report Is provided for State of Florida product approval under Rule 6IG20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid, This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein, METALS,INC. CREEK DREXEL Metal Roofing TFECHNICAL SERVICes,LLC APPENDIX A INSTALLATION Note-Refer to the APPROVED RoOF SYsrgms section of this report for specific installation details of a selected system.' Unless otherwise specified In this report the following installation details shall be met for the named products: Component Product Installation Detail 0-15 HWH wood screw with sealing washer, #10-14 HWH wood screw with sealing washer Shall penetrate through the sheathing a minimum 318 In. Must be corrosion #10-15 HWH wood resistant In accordance with FBC section 1507.4.4. Fasteners screws with dual threads and sealing washer #10-13 PH wood screw #10-16 DP3 PH self- dd Iling screw Shall penetrate through the top rib of the steel deck a minimum 3/4 In. Must be #14-13 DPI PH self- corrosion resistant In accordance With FBC section 1507.4.4. drilling screw 3" Bearing Plates- Is ga.Bearing Plate 24 ga.In-seam clip V\ DMC I 50SL Clip Clips 24 ga.SS In-seam clip t24 ga.DMC 15OSS Clip 2" DRX15001.6 FL17678-R6 Page 1 of 12 This evaluation report is provided for State of Florida product approval under Rule 61620-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty. Installation,recommended use,or other product attributes that are not specifically addressed herein. METALS CREEK DREXEL Metaloofing TECHNICAL SERVICES,LLC APPENDIX A Component Product, Installation Detail 24 ga.in-seam clip. 1 24 ga.DMC 150SS Fixed T Clip 0 o z it 26 ga.in-seam clip 26 ga.DMC 150SS Fixed clip , —J • 22 ga.SS In-seam clip 22 ga.DMC 150SS Clip -—T Clips(CoM'd} 0 P O ' 22 ga.in-seam clip 4R 1�4 22 ga.DMC 15OSS Fixed Clip 0 P O 22 ga,bass;24 ga.butterfly In-seam clip h� 'pts DMC 150SS Butterfly Clip '—` 41- DRX15001.6 FL17676-R6 Page 2 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shah notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,Installation, recommended use,or-other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. C ![1 j. Metal Roofing TECHNICAL SERVICE=S,LLC APPENDIX A Component Product. Installation betail 22 ga.base,24 ga.butterfly In-seam clip DMC 150SS Continuous Butterfly Clip i 26 ga.In-seam clip •---� 1,! x.4'1 1 �--..... _ DMC 150SS Utility Floating Clip t '�J Clips(Cont'd) ?`f 18 ga.In-seam clip DMC 1755 UL Clip 1 �. 22 ga.SS In-seam clip 8n , DMC 2005 Clip ." T pn DRX15001.6 FL17678-R6 Page 3 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i CREEK DREXEL METALS,ting Metal Roofing TI CHNICAL SERVICES,LLC APPENDIX A Component Product Installation Detail 18 ga.base;22 ga.butterfly In-seam clip;4.5 in.length DMC 2005 Butterfly Clip 18 ga.base;22 ga.butterfly in-seam clip;120 in.length;top slider 12 In.o.c. DMC 2005 Continuous f .; ... Butterfly Clip Clips(Cont'd) t t + 24 ga.in-seam clip DMC 450 Clip 24 ga.SS In-seam clip DMC 450SS Clip Sealants BosUk 70-05A Shall be applied In continuous beads along the seam Bostik Chem-Calk 915 Fastening Details Nomenclature Attachment LLMC 1OONS PANEL DMC 70otus Standard , DRX15001.6 FL17678-R6 Page 4 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. a^ CREEK DRIXELMing. MetaletalRoofing TECHNICAL S>~Rvilms,LLC APPENDIX A Component Product Installation Detail DMC'100NS PANE. BOSTIK 70-05A(2 -3/16" BEADS) -#10 - 13 PHW DMC 10ONS Enhanced OMC 15GSL PANEL - DIVIC I50SLCLIP #10-13 PHW(2 Per Clip) UNDERLAYMENT DMC 150SL Standard DMC 15OSS PANEL DMC 15088 CONTINUOUS BUTTERFLY CLIP- (2)#10-13 PHW UNDERLAYMENT' DMC 15OSS Continuous SUBSTRATE Butterfly 4 4 C DMC 150SS PANEL DMC 15OSS BUTTERFLY CLIP (2)#10-13 PHW UNDERLAYMENT---� DMC 15OSS Butterfly SUBSTRATE 1 4 + i i DRX15001.6 FL17678-R6 Page 5 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LSC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing Y TECHNICAL SERVICEs,LLC APPENDIX A Component Product Installation Detail DMC 15DSS PANEL. RMC 15DSS BUTTERFLY CLIP t\� (2)_#14-13 PHDD— ,t DERLAYMENT -,\ 3x3-16GA BEARING PLATE—11�``�`ti ISC3METALDECK DMC 150SS#14 Butterfly 3a1::l: DMC 15OSS PANEL--.---,--.— 24 GA DMC 15OSS FIXED CLIP (2)#10-13 PHW~--- UNDERLAYMENT_ t SUBSTRATE DMC 150SS Fixed-90 it J - 7i!`BFJID OOSriK CNEYItALN SiS ^'APPIJEO m Dos»auIE6 OF cuP ._.....OW 16M PANU .._, 24UAM154MIXED CLIP _ 11V sun B03rit NEM*"A' i �.APPtlED7V 607H=E OF CLIP DMC 15OSS#14 Fixed- 90 i I , 2 #14.13 DPi PH Screws per clip;Clip Installed over 183 ga.bearing late DMC 15OSS PANEL 1 24 GA DMC 16OSS CLIP------� (2)#10-13 PHW UNDERLAYMENT 1 DMC 150SS Standard(Al) SUBSTRATE ? ty ll li 'C DRX15001.6 FL17676-R6 Page 6 of 12 This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. jCREEK DREXEL METALS,INC. Metal Roofing TzcHNICAL SERVICES,LLC APPENDIX A Component Product Installation.Detail 114"BEAD BOSTIK 70-Q5A DMC 15OSS PANEL 22 GA DMC 15088 FIXED CLIP—, `.. DMC 150SS Fixed (2)910-13 PHW-•---•--- -} Enhanced-90 UNDERLAYMENT— 1 SUBSTRATE--� l DMC 15OSS PANEL`-----" \ 22 GA DMC 15OSS FIXED CLIP (2)#10-13 PHW UNDERLAYMENT--- DMC 15OSS Fixed SUBSTRATE .Enhanced-180 1 s G _ r 1W BEAD BOSTIK 70-05A- DMC 15OSS. PANEL —� 22 GA DMC 15088 CLIP (2)1510-13 PHW---� DMC 15OSS Enhanced(AO UNDERLAYMENT i SUBSTRATE i a DRX15001.6 FL17678-R6 Page 7 of 12 This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK . Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. r w [)REXEL METALS, Metal Roofing CREEK TECHNICAL SrRvICES,LLC APPENDIX A Component . Product Installation Detail DMC 1509S PANEL DMC 150SS CLIP (2)#10-13 PH Screws UNDERLAYMENT --;t DMc Boss Zinc SUBSTRATE— DMC G DMC 1755 Panal— DMC 175S UL ChP---••-may'` MO-13 PN Screw • l2l Der olip \\ DMC 1755#10 Standard DMC 175S PAA#I �,., OMC 1753 UL Ciip 410.13 PH Screw--•—.; '• Rloercllp Ur BEAD BMW CHEM-CALK • � . 915 MALE LEG AND BOTH WDES i •', OF CLIP IM"BEADBOMCHSMALK DMC 175S#10 Enhanced 815 ON FEWLE LEG 1 t. DRX15001.6 FL17678-R6 Page 8 of 12 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,t.I_C of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. A.. . _ pREXEL METALS,IN GREEK Metal Rooting TECHNICAL SgRviczs,LLC APPENDIX A Component ProdJU T Installation.Detail DMC 1755 PANEL— DMC 1755 UL CLIP 014-1S DPI PHDD(2 Per Ob) --1 W-MA BEARING PLATE-'-1 METAL DECKS IBD INSULATION 1 \ DMC 175S#14-Standard DMC 2005 PANEL-__....-.._-........._. DMC 200S BUTTERFLY CLIP UNDERLAYMENT -} SUBSTRATE-•- 4 4 DMC 200S Butterfly 1 j I ;1 ' r– DMC 200S PANEL--N DMC 200S BUTTERFLY CLIP--r #10-16 DP3 PHD UNDERLAYMENT- METAL DECK---\A DMC 200S Butterfly(Steel) ��� Use 18 ga.bearing plate over polylsocyanurate insulation DRX15001.6 FL17678-R6 Page 9 of 12 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any,product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. i :;. CREEK .+`R E E K DREXEL Metal Roi 9 TECHNICAL SERVICES}LLC APPENDIX A Component J .Product Installation Detail DMC ZOOS PANEL DMC 2005 CONTINOUS BUTTERLY CLIP #10 A 6 DP3 PHD 7� UNDERLAYMENT METAL DECK,--,- DMC 200S ContinuousButterfly(Sleet) Use 16 ga.beating late over polylsoryanurate insulation DMC 2005 PANEL-- ---. DMC 200S CLIP (2)#10-13 PNW_......---_<.._.W..� UNDERLAYMENT! s SUBSTRATE--t 1 DMC 2005 Fixed 4 l r f 114"BEAD BOSTiK 70415A DMC 200S PANEL. DMC 2005 CLIP DMC 2005 Fixed (2)010-13 PHW —i Enhanced UNDERLAYMENT SUBSTRATE �( 1 4 DRX15001.6 FL17678-R6 Page 10 of 12 This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. i Y GREEK DREXEL Metal LS,Roofing fing Metal Roofing `r'ECHNICAL SERVICES, LLC APPENDIX A Component Product Installation Detail DMC 450 DMC 450 450 CLIP---------` #10-13 PHW(2 Per Clip)---\ DMC 450 Standard i DMC 450 PANEL DMC 450 SS CLIP— #10-13 PHW(2 Per Clip) DMC 45OSS Standard x9,9.19 WM WOOD 3CREW WITH SEALING WASHER DMC 5V Standard #1 b-14 DREXMET WOODSCREW.-------\ DMC 5V PANEL- -- -\ METSHIELD HT UNDERLAYMENT----� \ \` �1 DMC 5V#10 Standard PLYWOOD----` , \ 1 ` t t 5 DRX15001.6 FL17678-R6 Page 11 of 12 This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, Installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL,SERVICES,LLC APPENDIX A Component Product Installation Detail DMC 5V PANEL *10-14 DREXI&T WOODSCREW UNDERLAYMENT DMC 5V Pan Fastening ONLY REQUIRED AT PANEL ENDS IF —9" COVERAGE ;c-15 kwtt w000scre>tiv(DUAL tr"'> 12"o.c. tc 36'o,c. WJf. ROW SPACING DMC Corrugated ---uNpERLArfdEtiT --15/52- U.N. PLYWOOD DRX15001.6 FL17678-R6 Page 12 of 12 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i i CREEK DREXEL METALS,INC. Metal Roofing_ TECHNICAL SERVICES,LLC APPENDIX B APPROVED ROOF SYSTEMS ' The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressure(MDP)was calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s)below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on-center(o.o.)spacing given is the maximum allowable attachment spacing for the rated system. 5. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga(Fy=min.33 ksi)Wide Rib Deck(Type WR) conforming to ANSUSDI-RD1.0&FBC_ S. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/324nch thick APA Span-Rated plywood sheathing at maximum 244nch span. -- Roof System Numbers and Definitions 10ONS-W# DMC 10ONS over Wood Deck(New or Existing) 150SL-W# DMC 150SL over Wood Deck New or Existing) 150SS_S# DMC 15OSS over Steel Deck New or Existing) 150SS-W# DMC 150SS over Wood Deck New or Existing) 175S-S# DMC 1755 over Steel Deck New or Existing) 175S- # DMC 1755 over Wood Deck new or E)dstln 200S-S# DMC 200S over Steel Deck New or Existing) 200S-W# DMC 200S over Wood Deck New or Existing) 450-W# DMC 450 over Wood Deck(New or Exlstl 5V-W# DMC 5V over Wood Deck New or Existing) COR-W# DMC Corrugated over Wood Deck New or Existing) Approved Systems for DMC 100NS over Wood Deck(Newor.Existing) SystemDeck Fire Barrier Underla ent Roof Panel Panel Attachment . MDP No. (psfl Min.15/32 OPTIONAL As 24 ga.DMC I DONS DMC?DONS Standard attachment ,97.5 10ONS-W1 CDX plywood Versashleld Solo required per FBC Max.16-inch wide with fastener spaced 10.5 in.o.c. 10ONS-W2 Min.15/32 OPTIONAL As required per FBC 24 ga.DMC 10ONS DMC 10ONS Standard attachment 420 rs CDX plywood Veashleld Solo Max.16-Inch wide with fasteners spaced 5.25 in.O.G. 10ONS-W3 Min.15/32 OPTIONAL As required per FBC 24 ga.DMC 100NS DMC 10ONSEnhanced attachment -135 CDX plywood Versashield Solo Max.16-Inch wide with fasteners spaced 525 In.o.c. i DRX15001.6 FL17678-R6 Page 1 of 8 i This evaluation report Is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CRDREXEL METALS,INC. Metal Rooting TECHNICAL.SERVICES,LLC APPENDIX B Approved Systems for DMC 150SL over Wood Deck New.or Existing) SystemDeck Fire Barrier' Underlayment Roof Panel Panel Attachment ' MDP } No. (pso Min.15132 OPTIONAL 24 a Standardattachment 150SL-WI As required per FBC g 'DMC 150SL DMC 150SL ttht -52.5 CDX Plywood Versashield Solo Max.16-Inch wide with clips spaced 16 in.o.c. _ Approved Svsti3ms for DMC 15OSS'over Steel Deck New or,Existin System Deck. Fire Barrier.. Insulation Underlayment Roof Panel . Panel Attachment MDP No. (psi Min.22 ga. Min.1 in.Approved 15OSS-81 Type B, As required 24 ga.DMC 15OSS DMC 15OSS#14 Butterfly attachment req polyisocyanurate As required per FBC Max.16-inch wide with clips spaced 36 in.o.c. "41'T Grade 80 Steel insulation board Min.22 ga. Min: i in.Approved Approved ASTM D 24 ga.DMC 15OSS DMC 15OSS#14 Fixed-90 attachment 15OSS-S2 Type B, As required pot insulation 1970 underlayment Max.16-Inch wide with clips spaced 16 In.o.c. -71 Grade 80 Steel insulation board Min.22 ga. Min.1 In.Approved 24 ga.DMC 150SS DMC 15OSS#14 Butterfly attachment 15OSS-83 Type B, As required polyisocyanurate As required per FBC Max 16 inch wide with clips spaced 24 in.o.c. -9Z'4 Grade 80 Steel Insulation board P Min.22 ga. Min.1 In.Approved 24 a DMC 15OSS DMC 15OSS#14 Butterfly attachment 15OSS-S4 Type B, As required polylsocyanurate As required per FBC g ' 417.8 1 Grade 80 Steel Insulation board Max.16-inch wide with clips spaced 18 in.o.c. Min.22 ga. Min.1 in.Approved 24 ga.DMC 15OSS DMC 15OSS#14 Butterfly attachment 15OSS-S5 Type B, As required polylsocyanurate As required per FBC Grade 80 Steel insulation board Max.16 inch wide with clips spaced 12 in.o.c. Min.22 ga. Min.1 in.Approved 24 ga.DMC 15DSS DMC 15OSS#14 Butterfly attachment 15OSS-S6 Type B, As required polyisocyanurate As required per FBC Max.16 inch wide with clips spaced 6 in.o.c_ JL68J.5 Grade 80 Steel Insulation board } DRX15001.6 FL17678-R6 Page 2 of 8 Ibis evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. I , s;a CREEK DREXEL Metal Roofing TECHNICAL SERVICES,LLC APPENDIX B Approved Systems for DMC 15t)SS over Wood[Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (Psf) Min.15132 OPTIONAL Approved ASTM D 0.02T'(0.7mm)Zinc DMC 15OSS DMCISOSS Zinc attachment 150SS-W7 CDX ! Max.15.74nch wide with DMC 15OSS Utility Floating Clips -78.5 p ywood Versashleld Solo 1970 underlayment 1800 seam spaced 18 in.o.c. 15OSS-W2 Min.15132 OPTIONAL Approved ASTM D 0.027'(0.7mm)Zinc DMC.150SS DMC15OSS Zinc attachment CDX•piywood Versashield Soto 1970 underiayment Max'15.7-Inch wide with DMC 154SS Utility Floating Clips -86 180 seam spaced 6 in.o.c. 15OSS-W3 Min 15132 OPTIONAL Approved ASTM D 0.027°(0.7mm)Zinc DMC 15OSS DMC15OSS Zinc attachment COX plywood Ver ashleld Solo 1970 undertayment Max.15.74nch wide with 26 ga.DMC 150SS Fixed Clips spaced 46 180°seam 18 in.o.c. Min.15132 OPTIONAL 0.032°AI DMC 15OSS DMC 15OSS Standard(Al)attachment 15OSS-W4 CDXI ood Versashleld Solo As required per FBC Max,16-finch wide -90 p Yw 1800 seam with clips spaced i6 in.o.c. Min.15/32 OPTIONAL 24 ga.DMC 150SS DMC 150SS Fixed-90 attachment 150SS-W5 CDX Versashield Solo As�ui��FBC Max �yw°� 900 seam with clips spaced 16 in.o.c. Min.15/32 OPTIONAL 24 ga.DMC 15OSS DMC 15OSS Butterfly attectiment 150SS-W6 CDXplywood As required per FBC Max.16-inch wide -99.25 p yWOod Versashield Solo 1800 seam with clips spaced 16 in.o.c. 150SS-W7 Min.15132 OPTIONAL Approved ASTM D 0.027"(0.7mm)Zinc DMC 1505S DMC15OSS Zinc attachment CDX plywood Versashield Solo 1970 undedayment Max.15.74nch wide with 26 ga.DMC 15OSS Fixed Clips spaced 408.5 1800 seem 9 In.o.c. 150SS-W8 Min.15132 OPTIONAL As required per FBG Maxa 1 MC 1 wide DMC 15OSS Continuous Butterly -114,25 CDX plywood Versashleld Solo 180°seam attachment with fasteners spaced 12 In.oc.. Min.15132 OPTIONAL 24 ga.DMC 15OSS DMC 15OSS Fixed Enhanced-90 150SS W9 CDX plywood Versashield Solo As required per FBC Max.16-inch wide attachment -150 Min.90°seam with clips spaced 12 in.o.c. Min.15/32 OPTIONAL 24 ga.DMC 15058 DMC 15OSS Fixed Enhanced-180 15088-W 70 CDX plywood Versashield Solo As required per FBC Max.16-inch wide attachment 465 Min.1809 seam with Gips spaced 8In,o.c. DRX15001.6 FL17678-R6 Page 3 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid, This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. C -v CREEK DREXELMet RooifiN g TECFINICAt.,SERVICES,LLC APPENDIX B Approved Systems for DMC 160SS over Woad Deck(New or Existing), System Deck Fire Barrier Vnderiayment Roof Panel Panel Attachment MDP No. (Psfl Min.16132 OPTIONAL 0.032°AI DMC 15 OSS wide 150SS-W 1 i DMC 15OSS Enhanced(At)attachment I CDX plywood Versashleid Solo required per FBC Max.16 inch wide with fps spaced 8 In.a c. `180 ( 180°seam roved Systems for DMC 175S over Steel Deck New of Exis6n 1 System. Deck Fire Barrier Insulation Undedayirrerit Roof Panel Panel Attachment MDP No. (iI Min.22 Min.1 in-Approved 1758-S1 g8" As required polyisocyanurate As required per FBC 2&Max. DMC 1 id DMC with clips ps s#14 Standard attachment -60 Type B Steel Insulation board x.it3 inch wide wtth clips spaced 36 in.o.c Min.22 ga. Min.1 In.Approved 0.040"AI DMC 175S DMC 175S#14 Standard attachment 1755-52 Type B Steel As required polylsocyanurate As required per FBC Max.17.5-inch wide with clips spaced 18 in.o.c. Insulation board Min.22 ga. Min.i in.Approved 24 ga.DMC 1755 DMC 175S#14 Standard attachment 1755-S3 Type B Steel As wired polylsocyanurate As required per FBC insulation board Max.i 8-Inch wide with clips spaced 6 In.o.c -105 Min.22 a. Min.1 in.Approved 1758-S4 g As required s 0.040"Al DMC 175S DMC 175S#14 Standard attachment Type B Steel q Po1yl tion borate As required per FBC Max.17.5-inch wide with clips spaced 12 in.o.c. -129.25 insulation board Approved'Systems for DMC 175S over Wood Deck(New or Existing) System MDP No Deck Fire Barrier Underlayment . Roof panel Panel Attachment Min.15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Standard attachment 1755 W1 CDX plywood Versashletd As required per FSC Max.18-Inch wide with clips spaced 24 in.o.c. 452.5 lo MIX.15/32 OPTIONAL 0,g32"At DMC 175S DMC 175S#10 Standard attachment 1755-W2 CDX plywood Versashleid As required per FBC 59.4 ��° Solo T Max.184nch wide with dips spaced 18 in.o.c. DRX15001.6 FL17678-R6 Page 4 of 8 This evaluation report is provided for State of Florida product approval under Rule 61020-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i CREEK DREXELMETALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX B Approved Systems for'DMC 1755 over Wood Deck(N!mW or Existing) I System Deck . Fire Barrier Underly ent Roof Panel Panel Attachment MDP No. (Psf OPTIONAL I Min.15132 0.032°AI DMC 175S DMC 175S 410 Standard attachment -664 175S-W3 COX plywood Versashield As required per FBC Max.18 inch wide with clips spaced 12 In.o.c. .Salo Min.15/32 OPTIONAL 0.032"AI DMC 175S DMC 175S#10 Standard attachment 175S-W4 Versashield As required per FBC spaced 8 in.o.c. 71 COX plywood Soto Max.18 inch wide with clips p i Min.15132 OPTIONAL 0.032'AI DMC 175S DMC 1755#10 Enhanced attachment 71 175S-W5 Versashleld Approved ASTM D 1970 undedayment COX plywood Solo 18-inch wide with clips spaced 12 in 0-c ASTM D 226,Type II roofing felt attached per I 175S-W6 Min.15/32 1518.2.1 with nails and tin caps per 1517.5 0.032'AI DMC 175S DMC 175S#10 Standard attachment _74.75 COX plywood followed by Metshield High Temp Max.18-inch wide with clips spaced 24 in.o.c. Underlayment self-adhered to felt Min.15/32 OPTIONAL 0.032'AI DMC 175S DMC 175S#10 Standard attachment 175S-W7 COX plywood Versashield As required per FBC Max.14 Inch wide with clips spaced 12 In.o.c. -82 5 Soto OPTIONAL 24 a DMC 1755 DMC 1755#10 Standard attachment 175S-W8 Min.15132 Versashield As required per FBC g ' '�2'' COX plywood Solo Max.18-inch wide with clips spaced 16 in.o.c. Min OPTIONAL 24 DMC 175S DMC 175S#10 Standard attachment -97.5 CX plywood 175S-W9 OX plywwoo 9 'Versashield As required per FBC a od Solo Max.16-inch wide with clips spaced 25 in.O.G. Min.15/32 OPTIONAL 0.040"AI DMC 1755 DMC 1755#10 Standard attachment _106,75 175S-W10 COX plywood Versashleld As required per FBC Max.17.5-inch wide with clips spaced 18 In.o.a Solo Min' 15!32 OPTIONAL 24 ga.DMC 175S DMC 1755#10 Standard attachment _121 75 i 1755-W11 COX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 8 in.o.c. Sob ASTM D 226,Type II roofing felt attached per 175S-W12 Min.15132 _ 1518.2.1 with nails and tin caps per 1517.5 0.032"AI DMC 175S DMC 175S#10 Standard attachment _131 COX plywood followed by Metshield High Temp Max.184nch wide with clips spaced 6 in.o-c. Undedayment self-adhered to felt Min.19/32 OPTIONAL 24 ga.DMC 175S DMC 175S#10 Standard attachment 175S-W13 CDX plywood Ve Seshhield As required per FBC Max,16-inch wide with clips spaced 8 in.o.c. -135 i I DRX15001 6 FI-17678-R6 Page 5 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. i s x" DREXEL METALS,INC. 1 CREEK Metal Roofing (� 'TECHNICAL.SERVICES,LLC APPENDIX B Approved S ystents for DMC 2005 over fateet Dei:k New or Existing) I S stem Deck Fire Barrier Insulation Underlay Roof Pane! Panel Attachment MDP No. (Psf} I Min.1 In.Approved 24 ga.DMC 2008 20o5-S1 Min.22 ga. As required polyisocyanurate As required per FBC Max 16-Inch wide DMC 2005 Butterfly(Steel)attachment -88 Type B Steel insulation board 180'seam with clips spaced 24 in.o.c- E 24 ga.DMC 2005 2005-S2 Min'22 ga' As required None As required per FBC Max 16 inch wide DMC 200S Butterfly(Steel)attabhment 81.75 Type B Steel 180'seam with clips spaced 24 in.o.c. i Min.22 ga. Min.1 In.Approved 24 ga.DMC 2005 DMC 2005 Continuous Butterfly(Steel) 2005-S3 As required polyisocyanurate As required per FBC Max 16dnch wide 421.75 Type B Steel insulation board 180"seam attachment with clips spaced 12 In.o.c. Min.22 ga. 24 ga.DMC 2405 DMC 2005 Continuous Butterfly(Steel) 2005-S4 Type B Steel As required None As required per FBC Max.16-inch wide attachment with clips spaced 121n.o.c. 451.75 180"seam Approved Systems for DMC ZOOS over Wood neck(New or Existing) System Deck Fire Barrier 'Underiayment Roof Panel Panel Attachment MDP No. (Psfl Min.15132 OPTIONAL 24 ga.DMC 200S DMC 200S Butterfly attachment 2005-W1 CDX plywood Versashieid Solo As required per FBC Max.16-Inch wide with dips spaced 24 in.o.c. .67.5 160°seam Min.15/32 OPTIONAL 0.040'Al DMC 2008 DMC 200S Butterfly attachment 2005-W2 .CDX plywood Versashteld Solo, ood As required per FBC Max with dips spaced 24 in.o.c. 16-inch wide 75 l 180 seam Min.19/32 OPTIONAL 0.040'Al DMC 2008 DMC 200S Fixed attachment 2005-W3 CDX plywood Versashield Solo As required per FBC Max-16-Inch wide p p -105 } 180 seam with clips spaced 16 in.o.c. 040"At DMC 2005 Min.19132 OPTIONAL 0. DMC 2008 Fixed Enhanced attachment 480 2005-W4 CDX plywood Versashield Soto As required per FBC Max.16-inch wide with clips spaced 8 in.o.c. 180°seam DRX15001.6 FL17678-R6 Page 6 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. l j I ' # i' CREEK DREXEL METALSMetaloofing }i TECHNiCAA1.SERVICES,LLC APPENDIX B Approved.Systems-for DMC 450 over Wood Deck(New or Existing) System Deck Fire Barrier .Underiayment Roof Panel Panel'Attachment MDP No: (psf) 450-W1 Min.19132 OPTIONAL As required per FBC 24 ga.DMC 450 DMC 450 Standard attachment .30 CDX plywood Verseshield Solo Max.16-Inch wide with clips spaced 241n.o.c. r j Min.15!32 OPTIONAL 0.032"Al DMC 450 DMC 45OSS Standard attachment 450-W2 CDX plywood Versashleld Solo required per FBC -45 i Max.16-inch wide with clips spaced 16 In.o.c. 1 450_W3 Min.19132 OPTIONAL As required per FBC 24 ga.DMC 450 DMC 450 Standard attachment 67.5 i CDX plywood Versashield Solo Max.16-Inch wide with clips spaced 15.5 In.o.c. 450-W4 Min.15/32 OPTIONAL As I� required per FBC 0.032"Al DMC 450 DMC 45OSS Standard attachment 75 CDX plywood Versashield Soto Max.16-4nch wide with clips spaced 6 in.o.c. I 450-W5 Min,19132 OPTIONAL As required per FBG 24 ga.DMC 450 DMC 450 Standard attachment -82.5 CDX plywood Versashield Solo Max.16-Inch wide with clips spaced 6 in.oc. Approved Systems for DMC 5V over.Wood.Deck(New or Existing) System Fie Barrier/ MDP No Deck insulation Undertayment Roof Pantie! Pane!Attachment (psf) ASTM D 226,Type II rooting felt attached per 0.032'AI DMC 5V OPTIONAL DMC 5V#10 Standard attachment Min.15!32 1518.2.1 with nails and On caps per 1517.5 Min.21-Inch to W1 CDX Plywood Approved fire barrier followed by Metshield High-Temp Max.24-inch with ling washers HWH wood screws with -56 j at insulation Undedayment setf-adhered to felt coverage sealing washers spaced 18 in.o.c. 26 ga.DMC SV 1 Min.15132 OPTIONAL Min.21-Inch to DMC 5V Standard attachment 5V-W2 Approved fire barrier As required per FBC with#9-15 HWH wood screws with -60 CDX plywood or Insulation Max 2`I inch sealing washers spaced 16 in.o.c. coverage OPTIONAL ASTM D 226,Type 11 roofing felt attached per 26 ga.DMC 5V DMC 5V#70 Standard attachment Min.15/32 1518.2.1 with nails and tin caps per 1517.5 Min.21-inch to W3 -CDX plywood Approved fire barrier followed by Metshietd High-Temp Max.24-Inch with#10-14 HWH wood screws with 71 or insulation Underlayment self-adhered to felt coverage sealing washers spaced 24 in.o.c. i DRX15001.6 FL17678-R6 Page 7 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other Product attributes that are not specifically addressed herein. ' AckEEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC • APPENDIX 8 Approved Systems for DMC 5V over Wood Deck(Ntw.or Existing) .System Deck Fire Barrier/ MDP- No. Roof Pane!- Fane(Attachment (psB No. insulation .. I 26 a DMC 5v OPTIONAL g ' DMC 5V Fan Fastening attachment I 5V-W4 Min.7116 OSB A roved fire barrier As Min.21-inch to i ply, pp required per FBG Max.24-inch with#10-14 HWH wood screws with -75 or insulation sealing washers spaced 16 In.o.c. coverage OPTIONAL 26 ga.DMC 5V DMC 5V Fan Fastening attachment Min.7/16 OSB Min.21-Inch to 5V-W6 pled Approved fire barrier As required per FBC with#10-14 HWH wood screws with -112.5 coverage or insulation Max.coverage h sealing washers spaced 8 in.o.c. .15132 OPTIONAL 26 ga.DMC 5V DMC 5V Standard attachment CDX 5V-W6 DX plywood Approved fire barrier As required per FBC Min.Min.21-inch to y #9-15 HWH wood screws with 421.75 or insulation Max.24-Inch coverage sealing washers spaced 8 in.a.c. ASTM D 226,Type!1 roofing felt attached per 26 ga.DMC 5V or OPTIONAL pt per 1517.5 0.032"Al DMC 5V DMC 5V#10 Standard attachment Min.15132 1516.2.1 with nails and fin ca 5V-WT CDX plywood Approved fire barrier followed by Metshleld High-Temp Min.21-Inch to with#10-14 HWH wood screws with -206 or insulation Underlayment self-adhered to felt Max.24-inch sealing washers spaced 6 In.O.C. _ coverage Approved Systems for DMC Corrugated over Wood Deck(New or Existing) System Fire Barrier/ MDP No Deck insulation l7ndeHayment Roof Panel Panel Attachment (psi Min'15132 OPTIONAL 0.032^A! DMC Corrugated DMC 5V Corrugatedattachment COR-W1 CDX plywood Approved fire barter As required per FBC Max.21-Inch coverage with#10-15 HWH wood screws with dual threads -60 orinsulation and sealing washer spaced 36 in,o.c. Min.15/32 OPTIONAL 26 ga DMC Corrugated DMC 5V Corrugated attachment COR-W2 CDX plywood Approved fire barrier As required per FBC Max.21-Inch coverage with#10-15 HWH wood screws with dual threads -60 or insulation and sealing washer spaced 36 in.o.c. Min.15132 OPTIONAL 0.032„AI DMC Corrugated DMC 5V Corrugated attachment COR-W3 CDX € Approved fire barrier As required per FBC with#10-15 HWH wood screws with dual threads 435 p S�Y4Od or insulation Max 21-inch coverage and sealing washer spaced 12 in.o.c. M€m 15M2 OPTIONAL 26 ga.DMC Corrugated DMC 5V Corrugated attachment COR W4 CDXplywood Approved fire barrier As required per FBC 9e with#10-15 HWH wood screws with dual threads -150 or insulation Max.21-Inch covers and sealing washer spaced 12 in.o.c. DRX15001.6 FL17678-R6 Page 8 of 8 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. METALS,INC. CREEK DREXEL Metal Roofing TECHNICAL SERVICES,LLC APPENDIX C DEsioN WIND LOADS The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-10 under the following provisions: 1. For Hip roofs between 2:12 and 5.612,Zone 3 shall be treated as Zone 2. 2. Wind speeds for risk category 1, 11,111,and IV buildings shall be as defined In Section 1609 of the FBC. 3. Exposure B,C,and 0 shall be as defined in section 1609 of the FBC. 4. Design wind load provided only for gabIdUp roofs with roof slopes between 2-12 and 6.112 5. All calculations are based on an effective wind area of 10-fig or less. 6. Topographic factors such as escarpments or hills have been excluded from the analysis 7. Overhangs have been excluded from the analysis. 8. Wind directionality factor,Kd=0.85 9. Vuit is shown in the tables below.Design wind loads are calculated using Vasd=VutAk per 1609.3.1. 10. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional 11. Zones 1.2,and 3 shall be defined as shown below. Dimension'a'shall be 10%of the least horizontal dimension or(0.4 x Mean Roof Height),whichever is smaller,but not less than either 4%of the least horizontal dimension or 3ft Gable Hip 3 2 3 13 2 3 1 a 2 2 1 2 2 1 2 1 2 2 1 2 0 3 2 1313 2 3 a 2 DRX15001.6 171-17678-116 Page I of 4 This evaluation report is provided for State of Florida product approval under Rule 6IG20-3. The manufacturer shall notify CREEK Technical Services.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. (3 L i` moi'�.c"(w{ DRE)EL METALS,INC. (� 4 `►�R E E l Metal Roofing TECHNICAL.SERVICES,LLC APPENDIX C Gabla&li Roofs'In ure'$ Roof sio .`between 2124rtd 6,11;121 , Building. - Mean -Basic Wind S eed Zane Roof } �$ Het ht '12p 11 ..130 . , i40 .150 160 170 1$0 190 200 20 -14.2 -16.7 -19.3 -22.2 -25.3 -28.5 32.0 •35.6 -39.5 25 -14.2 -16.7 -19.3 -22.2 -25.3 28.5 32.0 -35.6 -39.5 1 30 -14.2 -16.7 -19.3 -22.2 -25.3 -28.5 -32.0 -35.5 -39.5 40' -15.4 -18.1 1 21.0 -24.1 27.4 -31.0 -34.7 -38.7 -42.9 i 50 -16.5 -19.3 -22.4 -25.7 -29.2 -33.0 1 -37.0 -41.2 -45.7 60 -17.3 -20.3 -23.5 -27.0 -30.7 -34.6 38.8 -43.3 -47.9 20 24.7 29.0 -33.7 -38.7 -44.0 -49.7 -55.7 -62.0 -68.7 25 -24.7 -29.0 -33.7 38.7 -44.0 -49.7 55.7 -62.0 -68.7 Enclosed 2 30 -24.7 -29.0 -33.7 -38.7 -44.0 -49.7 55.7 -62.0 -68.7 40 -26.9 -31.5 -36.6 42.0 -47.8 -53.9 50.4 -67.3 -74.6 50 -28.6 -33.6 -39.0 -44.7 -50.9 -57.5 34.4 -71.8 -79.5 60 -30.0 -35.3 -40.9 -46.9 -53.4 -60.3 -67.6 -75.3 -83.5 20 36.6 -42.9 -49.8 -57.2 -65.0 -73.4 -82.3 -91.7 -101.6 25 -36.6 -42.9 -49.8 -57.2 -65.0 73.4 -82.3 -91.7 -101.6 3 30 -36.6 -42.9 -49.8 -57.2 -65.0 -73.4 -82.3 -91.7 -101.6 40 -39.7 -46.6 -54.1 32.1 -70.6 -79.7 -89.4 -99.6 -110.3 50 -42.3 -49.7 -57.6 -662 -75.3 -85.0 35.3 -106.1 -117.6 60 -44.4 -52.1 -60.5 -69.4 -79.0 -89.2 -100.0 -111.4 -123.4 20 -19.1 22.4 -26.0 29.8 -33.9 -38.3 -42.9 -47.8 -53.0 25 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.6 -53.0 1 30 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.8 53.0 40 -20.7 - 24.3 -28.2 -32.4 -36.8 -41.6 -46.6 -51.9 -57.6 50 22.1 25.9 -30.1 -34.5 -39.3 -44.3 -49.7 -55.4 -61.3 60 -23.2 -27.2 31.5 -36.2 -41.2 -46.5 -52.1 -58.1 -64A 20 -29.6 -34.8 -40.3 -46.3 -52.6 -59.4 -66.6 -74.2 -82.3 25 -29.6 -34.8 -40.3 -46.3 -52.6 -59.4 36.6 74.2 -82.3 Partially 30 29.6 -34.8 -40.3 -46.3 -52.6 -59.4 -66.6 -74.2 -82.3 Enclosed 2 40 32.2 -37.7 -43.8 30.2 57.2 -64.5 72.3 -80.6 -89.3 50 34.3 -40.2 -46.6 53.5 -60.9 -68.8 -77.1 -85.9 -95.2 60 -36.0 -42.2 -48.9 -56.2 -63.9 72.2 -80.9 -90.1 -99.9 20 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -116.2 25 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 3 30 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 40 -45.0 -52.8 -61.3 -70.3 -80.0 -90.3 -101.3 -112.8 -125.0 50 -48.0 -56.3 55.3 -75.0 -85.3 -96.3 -107.9 -120.3 -133.3 60 50.3 -59.1 -68.5 -78.7 -89.5 -101.0 -113.3 -126.2 -139.8 DRX15001.6 FL17678-R6 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20.3. The manufacturer shalt notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. I - y., DREXEL METALS,INC. CREEKMetal Roofing TECHNICALS F-RVICES,LLC APPENDIX C Gableltii Roofs In ibipasuie C 6fsl6pe between 2_12 and 6.1,!2 Building Mean i.BasicWirid Speed.(M614 Zone Roof I TYPg . Height ft 120 130 .140 150. .•• 160, 170 1&D 190 200 20 -18.3 -21.4 -24.9 -28.6 -32.5 -36.7 -41.1 45.8 -50.8 25 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.9 -53.0 1 30 -19.9 -23.4 -27.1 -31.1 -35.4 -39.9 -44.8 -49.9 -55.3 40 21.1 24.8 28.7 -33.0 -37.5 -42.4 -47.5 -52.9 -58.7 50 -22.1 -26.0 20.1 -34.6 -39.4 -44.4 49.8 -55.5 1 -61.5 ! 60 -22.9 -26.9 -31.2 -35.9 40.8 -46.1 -61.6 -57.5 -63.7 20 -31.8 -37.3 43.3 -49.7 -56.6 -63.8 -71.6 -79.8 -88.4 25 -33.2 -39.0 -45.2 -51.9 -59.1 -66.7 -74.8 -83.3 -92.3 Enclosed 2 30 -34.6 40.7 -47.2 -54.1 -61.6 -69.5 -77.9 -86.8 -96.2 40 -36.8 43.1 -50.0 -57.4 -65.4 73.8 -82.7 -92.2 -102.1 50 -38.5 -45.2 -52.4 -602 -68.5 -77.3 -86.7 -96.6 -107.0 1 60 -39.9 46.9 54.4 -62.4 -71.0 -80.2 -89.9 -100.1 -111.0 20 -47.0 -55.2 -64.0 -73.5 -83.6 -94.4 -105.8 -117.9 -130.7 25 -49.1 -57.7 -66.9 -76.8 -87.3 -98.6 -110.5 -123.2 -136.5 3 30 -51.2 -60.1 -69.7 -80.0 -91.1 -102.8 -115.3 -128.4 -142.3 40 -54.4 -63.8 -74.0 -84.9 -96.6 -109.1 -122.3 -136.3 -151.0 50 -57.0 -66.9 -77.5 -89.0 -101.3 -114.3 -128.2 -142.8 -158.3 60 -59.1 -69.3 -80.4 92.3 -105.0 -118.5 -132.9 -148.1 -164.1 20 -24.5 -28.8 -33.4 -38.3 -43.6 -49.2 95.2 -61.5 -68.2 25 25.6 -30.1 -34.9 -40.0 -45.6 -51.4 -57.7 24.2 -71.2 1 30 -26.7 -31.4 -36.4 -41.7 -47.5 -53.6 -60.1 -67.0 -74.2 40 28.4 -33.3 28.6 -44.3 -50.4 -56.9 -63.8 -71.1 -78.8 50 -29.7 -34.9 -40.5 -46.4 -52.8 -59.6 -66.9 -74.5 -82.5 60 -30.8 -36.2 -41.9 -48.1 -54.8 -61.8 -69.3 -77.2 -85.6 20 28.1 -44.7 -51.8 29.5 -67.7 76.4 -85.7 -95.4 -105.8 i 25 -39.8 46.7 -54.1 -62.1 -70.7 -79.8 -89.5 -99.7 -110.5 Partially 30 -41.5 48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 Enclosed 2 40 -44.0 -51.6 -59.9 -68.7 -78.2 -88.3 -99.0 -110.3 -122.2 50 -46.1 -54.1 -62.8 72.0 -82.0 -92.5 -103.8 -115.6 -128.1 60 -47.8 -66.1 -65.1 74.7 -85.0 -95.9 -107.6 -119.8 -132.8 20 -53.3 -62.6 -72.6 -83.3 -94.8 -107.0 -119.9 -133.6 -148.1 25 -55.7 .65.3 -75.8 -87.0 -99.0 -111.7 -125.3 -139.6 -154.6 3 30 -58.0 -68.1 -79.0 -911.7 -103.2 -116.5 -130.6 -145.5 -161.2 40 -61.6 72.3 -83.8 -96.2 -109.5 423.6 -138.6 -154.4 -171.1 50 -64.6 75.8 -87.9 -100.9 -114.8 -129.6 -145.2 -161.8 -179.3 60 -66.9 -78.5 -91.1 404.6 119.0 -134.3 -150.6 -167.6 -i85.9 DRX15001.6 FL17678-R6 page 3 of 4 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. DREXEL METALS,INC. �,.r► j i R E E D Metal Roofing f TECHMCAL SERVICES,LLC f APPENDIX C M :_.. tretween2'i2 dB_1 12 Bu4ding INeari ratite! Basic Wind a�ed(mph)' ii F�oofs in' sone D.Roof.si Zone Roof Yypg 220... 130 140 16tD: :..1�, tt70 160 .200 .._ .. Het 00' . : :. . .. j 20 -21.9 -25.7 -29.9 -34.3 -39.0 -44.0 -49.3 -55.0 -60.9 i 25 -22.7 -26.7 -31.0 -35.5 -40.4 -45.6 -51.2 -57.0 -63.2 1 30 -23.6 -27.6 -32.1 36.8 -41.9 -47.3 -53.0 -59.1 65.4 i 40 24.8 29.1 1 -33.7 -38.7 -44.0 -49.7 95.7 -62.1 -68.8 50 -25.8 -30.3 -35.1 -40.3 -45.9 -51.8 -58.0 -64.6 -71.6 60 -26.6 -31.2 -36.2 41.6 -47.3 -53.4 -59.9 36.7 73.9 20 -38.2 -44.8 -52.0 -59.7 -67.9 -76.6 95.9 -95.7 -106.0 25 -39.6 46.5 -53.9 -61.9 -70.4 79.5 39.1 -99.2 -110.0 Enclosed 2 30 -41.0 -48.1 -55.8 -64.1 -72.9 -82.3 -92.3 -102.8 -113.9 40 43.1 -50.6 -58.7 -67.4 -76.7 -86.5 -97.0 -108.1 -119.8 i 50 -44.9 -52.7 -61.1 70.1 79.8 -90.1 -101.0 -112.5 -124.7 60 -46.3 -54.3 -63.0 -72.4 -823 -92.9 -104.2 -116.1 -128.6 j 20 -56.5 -66.3 -76.8 -88.2 -100.4 -113.3 -127.0 -141.5 -156.8 25 -58.5 -68.7 -79.7 -91.5 -104.1 -117.5 -131.7 -146.8 -162.6 30 -60.6 71.2 -82.5 94.7 -107.8 -121.7 -136.4 -152.0 -168.4 3 40 -63.8 74.8 -86.8 -99.6 -113.4 -128.0 -143.5 -159.9 -177.1 50 -66.4 -77.9 -90.4 -103.7 • -118.0 -133.2 -149.4 -166.4 -184.4 60 -68.5 -80.4 -93.2 -107.0 -121.7 -137.4 -154.1 -171.7 -190.2 20 -29.4 -34.6 110.1 -46.0 -52.3 -59.1 -66.3 -73.8 81.8 25 -30.5 35.8 -41.6 -47.7 -54.3 -61.3 -6B.7 -76.5 -84.8 i� 30 -31.6 -37.1 -43.0 -49.4 •56,2 -63.5 -71.2 -79.3 -87.8 1 1 40 -33.3 -39.0 115.3 -52.0 -59.1 -66.8 74.8 -83.4 -92.4 50 -34.6 -40.6 -47.1 -54.1 -61.6 -69.5 -77.9 -86.8 -962 60 -35.7 -41.9. -48.6 -55.8 -63.5 -71.7 -BOA -89.5 -99.2 20 -45.7 53.6 -62.2 -71.4 -81.2 -91.7 -102.8 -114.5 -126.9 25 -47.4 -55.6 -64.5 -74.0 -84.2 -95.1 -106.6 -118.8 -131.6 Partially 2 30 -49.1 -57.6 -66.8 -76.7 -872 -98.5 -110.4 -123.0 -136.3 Enclosed 40 -51.6 -60.6 -70.2 -80.6 -91.8 -103.6 -116.1 -129A -143.4 50 -53.7 -63.1 -73.1 -83.9 -95.5 -107.8 -120.9 -134.7 -149.2 60 -55.4 -65.0 75.4 -86.6 -98.5 -111.2 -124.7 -138.9' -153.9 20 -64.0 75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7 25 -66.3 -77.8 1 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.3 3 30 -68.7 -80.6 -93.5 -107.3 -122.1 -137.9 -154.6 -1722 -190.8 40 -72.3 -84.8 -98.3 412.9 -128.5 -145.0 -162.6 -181.1 200.7 50 -75.2 -88.3 -102A 417.5 -133.7 -151.0 -169.2 -188.6 208.9 60 -77.6 -91.1 -105.6 421.2 -137.9 -155.7 -174.6 -194.5 -215.5 DRX15001.6 FL17678-R6 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61020-3. The manuFacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. MD=AV* MIAMI-DARE COUNTY REVIEWED PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC"OLM P L I C E 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 ST. LUr T( 86)315.2590 F(786)315-2599 NOTICE OF ACCEPTANCE OA ' e �' ° �c " Polyglass USA,Inc. 10 1?Q 150 Lyon Drive Fernley,NV 89405. t@ C_unty,Permitting SCOPE: File COPS, This NOA is being issued under the applicable rules and regulations governing,the use of construction materials.The documentation submitted has been reviewed and accepted by Miami Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:Polyglass Self-Adhered Roof System over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement:"Miami Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA#13-1217.01 and consists of pages 1 through 34. The submitted documentation was reviewed by Alex Tigera. -000 MIAMF DE COUNTY NOA No.: 17-1004.09 JAPPROVEDI Expiration Date: 10/11/22 Approval Date:10/12/17 Page 1 of 34 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Modified Bitumen Materials SBS/APP/TPO Deck Type: Wood Maximum Design Pressure -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Elastobase 65'2"x 3'3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced Type I .. base sheet. XtraFlex SBS Glass 65' 8"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced Base Type I base sheet. Polyglass G2 Base 108'x 36" ASTM D 4601 Asphalt-coated fiberglass reinforced base sheet Type II Polyanchor 250'x 48" ASTM D 4601 A polymer woven,high performance,synthetic base Type II sheet, Elastobase P 65' 8"x3'3-3/8" ASTM D 6164, SBS modified asphalt coated polyester reinforced base Type I sheet. Elastoflex SA V FR 66' 8"x3'3-3/8" ASTM D 6163, Self-adhered,fire-rated,fiberglass reinforced,'SBS Type I modified bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V 66' 8"x 3'3-3/8" ASTM D 6163, Self-adhered,fire-rated,fiberglass reinforced,SBS PLUS FR Type I modified bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V(1.5- 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered,fiberglass reinforced,SBS modified mm) Type I bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V 66' 8"x 3' 3 3/s" ASTM D 6163, Self-adhered,fiberglass reinforced,SBS modified PLUS Type I bitumen membrane with a self-adhering back face and a smooth top surface. XtraFlex SBS Base 66' 8"x 3'V/8" ASTM D 6163, Self-adhered,fiberglass reinforced,SBS modified SA Type I bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA P FR 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated,polyester reinforced,SBS Type I modified bitumen membrane with a self-adhering back face and a granule top surface. XtraFlex SBS G SA 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated,polyester reinforced,SBS Type I modified bitumen membrane with a self-adhering back face and a granule top surface. NOA No.: 174004.09 MiaatMDeeouim Expiration Date: 10/11/22- Approval 0/11/22Approval Date:10/12/17 Page 2 of 34 Elastoflex SA P 32' 10"x 3' 3-3/8" ASTM D 6164, SeMadhered,fiberglass reinforced,SBS modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyflex 32' 10"x3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. XtraFlex APP S 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polybond 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a bum off polyethylene back face and a smooth or sanded top surface. Polyflex G 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a bum off polyethylene back face and a granule top-surface. Polyflex SA P 32' 10"x 3'V/s" ASTM D 6222, Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyflex SA P FR 32' 10"x 3'3 3/s" ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP Type I modified bitumen membrane with a self-adhering back face and a granule top surface. XtraFIcx APP G SA 32' 10"x 3'VA" ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP Type I modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G SBS SA 32' 10"x 3' V/8" ASTM D 6164, Self-adhered,fiberglass reinforced,SBS modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G SBS SA 32' 10"x 3' V/8" ASTM D 6164, Self-adhered,fire-rated,fiberglass reinforced,SBS FR Type I modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G APP SA 32' 10"x 3'3-3/8" ASTM D 6222, Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G APP SA 32' 10"x 3'V/8" ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP FR Type I modified bitumen membrane with a self-adhering back face and a granule top surface PolyKool 32' 10"x 3'33/sl' ASTM D6222 Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a white film laminate on the top surface. XtraFlex Kool APP S 32' 10"x 3'33/s" ASTM D6222 Self-adhered,polyester reinforced,APP modified SA Type I bitumen membrane with a self-adhering back face and a white film laminate on the top surface. Polyglass APP Base 65' 8"x 3' 33/s" ASTM D 6509 APP modified asphalt coated fiberglass reinforced Type I base sheet. NOA No.: 17-1004.09 rtuaMl nanE eou� Expiration Date: 10/11/22 APPROVEDI Approval Date:10/12/17 Page 3 of 34 PG325 Cold Process 1,3,5, 50,55 gal.or ASTM D3019 A fibered cold process adhesive for use with roll or Adhesive tube Type III BUR roofing. PG100 Asphalt Primer 1,3,5,50,55 gal, ASTM D41 A penetrating solution of solvent and a blend of tube or 17 oz.spray selected asphalts used to promote adhesion. can XtraFlex 10 Asphalt 1,3,5,50,55 gal, ASTM D41 A penetrating solution of solvent and a blend of Primer tube or 17 oz.spray selected asphalts used to promote adhesion. can PG350 Mod Bit 1,3,5,50,55 gal,or ASTM D3019 A fibered rubberized adhesive designed for use with Adhesive tube Type M modified bitumen membranes. P0400 Plastic Roof 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement for use in Cement tube ASTM D3409 dry or damp conditions. PG425'Wet/Dry Roof 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement for use in Cement tube ASTM D3409 dry or damp conditions. PG450 Flashing 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement. Cement tube PG500 MB Flashing 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement for use Cement tube with modified bitumen membranes. Polyplus 35 Premium 1,3,5,50,55 gal.or ASTM D3019 A fibered rubberized adhesive designed for use with Mod Bit Adhesive tube Type III modified bitumen membranes. XtraFlex 35 Premium 1,3,5,50,55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with Mod Bit Adhesive tube. Type III modified bitumen membranes. Polyplus 45 Premium 1,3,5,50,55 gal. or ASTM D4586 A thick,'fibered,rubberized flashing cement. Flashing Cement tube Polyplus 50 Premium 1,3,5, 50,55 gal. or ASTM D4586 A thick,fibered,rubberized flashing cement for use MB Flashing Cement tube with modified bitumen membranes. XtraFlex 50 Premium 1,3,5,50,55 gal.or ASTM D4586 A thick,fibered,rubberized flashing cement for use Modificd Wet/Dry tube with modified bitumen membranes. Cement Polyplus 55 Premium 1,3,5,50,55 gal.or ASTM D4586 A mastic compound for use as a roof flashing Modified Flashing tube adhesive. Cement aaanecozin�rr NOANo.: 17-1004.09 "', 1�N� Expiration Date: 10/11/22 Approval Date:10/12/17 Page 4 of 34 i. APPROVED INSULATIONS: TABLE 2 Product Name Product Descrintion M—anufa_tuner (With Current NOA) Polytherm-H Polyisocyanurate foam insulation Polyglass USA,Inc. Poiytherm Polyisocyanurate foam insulation Polyglass USA,Inc. ACFoam-II Polyisocyanuratc foam insulation Atlas Roofing Corp ACFoam III Polyisocyanurate foam insulation Atlas Roofing Corp High Density Wood Fiberboard Wood fiber insulation board Generic DensDeck,DensDeck Prime Gypsum insulation board Georgia-Pacific Gypsum LLC H-Shield Polyisocyanurate foam insulation Hunter Panels,LLC H-Shield CO Polylsocyanurate/perlite composite insulation Hunter Panels,LLC ENRGY-3 Polyisocyanurate foam insulation Johns Manville Corp. Fesco Board Expanded mineral fiber Johns Manville Corp. Multi-Max FA-3 Polyisocyanurate foam insulation Rmax Operating,LLC. SECUROCK Gypsum-Fiber Roof Board Fiber reinforced coverboard United States Gypsum Corporation t i MuaAa coMY NOA No.: 17-1004.09 N�� ,,, Expiration Date: 10/11/22 Approval Date:10/12/17 Page 5 of 34 I APPRovED FASTENERS: TABLE 3 Fsten r Product Profluct Manufacturer Number Name Description Dimensions, (With Current NO—A) 1. Dekfast Fasteners 12, 14& Insulation fastener for wood, SFS Intec,Inc. 15 HS steel and concrete decks 2. Dekfast Galvalume,Steel Galvalume.hex stress plate. 2 7/s"x SFS Intec,Inc. Hex Plate 3114 3. #14 R.00fgrip Insulation and membrane Various OMG,Inc. fastener 4. Flat Bottom Metal Plate - A2-SS aluminized steel plate 3"square OMG,Inc. 5. Trufast#14 HD Fastener Insulation fastener for steel and Altenloh,Brinck&Co. wood decks U.S.,Inc. 6. Trufast 3"Metal Insulation Round Galvalume AZ50 steel 3.23 round Altenloh,Brinck&Co. Plate plate 3"round U.S.,Inc. 7. Polygrip Fasteners#12,#14 Insulation fastener for wood, Various Polyglass USA,Inc &#15 steel and concrete decks 8. Polygrip Hex Plates Galvalume hex stress plate. 2'/s"x Polyglass USA,Inc 3 % I I i I NOA No.: 174004.09 mm"MaoaoecouW Expiration Date: 10/11/22 Approval Date:10/12/17 Page 6 of 34 APPROVED SURFACING: TABLE 4 Product oduct Apnl_ication Man...- uf.- altar Name Description Rate 3peciEication er P0200 Non Fibered Roof Coating A non fibered asphaltic coating used 1'/2-2 gal/sq TAS 140 Polyglass to add life and rejuvenate existing USA,Inc. BUR roofing substrates. XtraFlex 20 Bituminous Roof A non fibered asphaltic coating used 1%a-2 gal/sq TAS 140 Polyglass Coating to add life and rejuvenate existing USA,Inc. BUR.roofing substrates. PG300 Fibered Roof Coating An asphalt cutback fibered roof 1'/z-2 gal/sq ASTM D4479 Polyglass coating. May be applied by brush or USA,Inc. spray equipment to rejuvenate aged BUR XtraFlex Bituminous Roof An asphalt cutback fibered roof 1'/z-2 gaUsq ASTM D4479 Polyglass Coating Fibered coating. May be applied by brush or USA,Inc. spray equipment to rejuvenate aged BUR PG600 Non-Fibered Aluminum Non-fibered aluminum roof coating. %z-1 gal/sq ASTM D2824 Polyglass Roof Coating Type I USA,Inc. PG650 Fibered Aluminum Roof Fibered aluminum roof coating. 1%z-2 gal/sq ASTM D2824 Polyglass Coating Type III USA,Inc. PG700 Elastomeric Roof Coating A premium white elastomeric acrylic 1-1%z gal/sq ASTM D6083 Polyglass based roof coating(water-based). A USA,Inc. polyester fabric may lie used for reinforcement with this coating. PG800 Non-Fibered Asphalt An asphalt base,un-fibercd clay 3 gal/sq in ASTM D1227 Polyglass Emulsion Roof Coating emulsion two coats USA,Inc. XtraFlex 80 Emulsion Roof An asphalt base,un-fibered clay 3 gal/sq in ASTM D1227 Polyglass ' Coating emulsion two coats USA,Inc. PG850 Fibered Asphalt Emulsion An asphalt base,fibered clay 3 gal/sq in ASTM D1227 Polyglass Roof Coating emulsion two coats USA,Inc. Polyplus 65 Premium Fibered Fibered aluminum roof coating. 1%r2 gat/sq ASTM D2924. Polyglass Aluminum Roof Coating Type III USA,Inc. XtraFlex 65 Aluminum Roof Fibered aluminum roof coating. 1%2-2 gal/sq ASTM D2824 Polyglass Coating Fibered Type III USA,Inc. Polyplus 60 Premium Non- Non-fibered aluminum roof coating. %z-1 gaUsq ASTM D2824 Polyglass Fibered Aluminum Roof Coating Type I USA,Inc. XtraFlex 60 Aluminum Roof Non-fibered aluminum roof coating. %a-1 gal/sq ASTM D2824- Polyglass Coating Type I USA,Inc. NOA No.: 17-1004.09 MuuH�a�oe aur Expiration Date: 10/11/22 JAPPRO Approval Date:10112/17 Page 7 of 34 APPROVED SURFACING: TABLE 4 Product Product ARulicatlon Manufac�' Snecifcation Name Description Rate M. Polybrite 70 Premium Grade A premium white elastomeric acrylic 1-1%i gaYsq ASTM D6083 Polyglass Elastomeric Roof Coating based roof coating(water-based). A USA,Inc. polyester fabric may be used for reinforcement with this coating. XtraFIex 70 Premium Acrylic FR A premium white elastotneric acrylic 1-1'/2 gat/sq ASTM D6083 Polyglass Roof Coating based roof coating(water-based). A USA,Inc. polyester fabric may be used for reinforcement with this'coating. Polybrite 90 High Solids Silicone A premium grade High solids,single 1.25 gal/sq) ASTM D6694 Polyglass Roof Coating component,moisture cure,fluid USA,Inc. applied silicone coating XtraFlex SRC 9600 High Solids A premium grade high solids,single 1.25 gal/sq ASTM D6694 Polyglass Silicone Roof Coating component,moisture cure,fluid USA,Inc. applied silicone coating Polybrite 95 Silicone Roof A single component,solvent, 1.25 gal/sq ASTM D6694 Polyglass Coating moisture cure silicone coating. USA,Inc. XtraFlex SRC 8000 Silicone Roof A single component,solvent, 1.25 gal/sq ASTM D6694 Polyglass Coating moisture cure silicone coating. USA,Inc. Gravel To be installed in a flood coat of 400 lbs/sq N/A Generic approved asphalt at 60 lbs/sq Slag To be installed in a flood coat of 300 lbs/sq N/A Generic approved asphalt at 60 lbs/sq NOA No.: 17-1004.09 Mta aouan�coun:n Expiration Date: 10/11/22 APPRVED_1 Approval Date: 10/12/17 Page 8 of 34 �I EVIDENCE SUB1V11 rrED: Test Aeencv Test Name/Raort Report No. Date Factory Mutual Research 4470 2W7A7.AM 08.04.94 Corporation 4450 2D5A9.AM 06.22.99 4470 3001334 02.15.00 4470 3000857 01.12.00 4470 3004091 01.12.00 4470 3012321 07.29.07 4450 3014751 08.27.03 4450 3019317 06.30.04 4470 3014692 08.05.03 l Trinity j ERD TAS 114 11752.09.99-1 02.08.00 TAS 114 02764.09.05 09.09.05 TAS 114 02762.03.05 03.30.05 TAS 117(B)-ASTM D903 020841.06.04 06.02.04 TAS 114 P1734.07.06 Rl 02.27.07 TAS 114 P1738.02.07 02.05.07 TAS 114 P1739.01.07 01.23.07 TAS 117(B)-ASTM D6862 C8500SC.11.07 11.30.07 ASTM D6164/ASTM D6222 PI 0490.08.08 08.13.08 ASTM D6164/ASTM D6222 P10490.10.08-R1 10.03.08 ASTM D6222 P7400.03.08-R2 10.09.08 TAS 114(D)—ASTM D18.76 P10070.10.08 10.09.08 ASTM D6222 . P10490.10.08-2 10.30.08 FM 4470&TAS 114 P33970.03.11 03.15.11 ASTM D6163/ASTM D 4601 P33960.03.11 03.15.11 TAS 114&TAS 117(B) 11757.12.00-1-RI 04.29.13 TAS 114&TAS 117(B) 11757.04.01-1-R1 04,30.13 ASTM D6164 P37590.07.13-1 07.02.13 ASTM D6164 P37590.03.13-3A 03.06.13 ASTM D6163 P37590.03.13-2-RI 02.05.13 ASTM D6222 P37590.09.13 09.12.13 ASTM D4601/TAS 117 P45940.09.13 09.04.13 TAS 114&FM 4474 P41630.08.13 08.06.13 TAS 114(H) P13760,09.09 09:10.09 ASTM D4601 /TAS 117 P45970.05.14 05.12.14 PRI Construction Materials ASTM D6222 PUSA-061-02-02 01:28.08 Technologies ASTM D6222 PUSA-062-02-02 12.04.08 ASTM D6163 PUSA-06402-02 02.27.08 ASTM D6694 PUSA-134-02-01 05.16.14 ASTM D6694 PUSA-135-02-01 05.16.14 NOA No.; 17-1004.09 I ►nE cow Expiration Date: 10/11/22 Approval Date:10/12/17 Page 9 of 34 rDk ,Type: SBS/APP : Wood,Non-Insulated ption: 19/32"or greater,plywood or wood plank,fastened at 24"spans with 8d common nail, t 4"o.c. or#8 wood screws at 6"o.c. e E(1): Base sheet is mechanically attached to roof deck. and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approvt be installed unless said accessories demonstrate compliance with prescriptive Florida Building ! Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Sheet: One ply of Elastobase,XtraFlex SBS Glass Base, Elastobase P or Polyanchor fastened to the deck as described below: r Fastening: Attach base sheet using 11 ga.annular ring shank nails and 1-5/8"diameter tin caps spaced 8" o.c.in a 4"lap and 8"o.c.in three equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V(1.5-nun),Elastoflex SA V PLUS,XtraFlex SBS Base SA,Elastoflex SA V FR(1.5-nun)or Elastoflex SA V PLUS FR,self-adhered. Membrane: One ply of Polyfresko G SBS SA,Polyfresko G SBS SA FR,Polyfresko G APP SA, Polyfresko G APP SA FR,Elastoflex SA P,Elastoflex SA P FR,XtraFlex SBS G SA,Polyfle SA P,PolyKool,XtraFlex Kool APP S SA,Polyflex SA P FR or XtraFlex APP G SA,self- adhered. Or One ply of Polyflex G,torch-applied. Surfacing: (Optional)Install one of the approved surfacing products listed in Table 4 to obtain des' ed coating or required fire classification. aximum Design essure: -52.5 psf;(See General limitation#7.). NOA No.: 17-1004.09 M � °STM Expiration Date: 10/11/22 Approval Date:10/12/17 Page 26 of 34