HomeMy WebLinkAboutNOA -Miami-Dade County 10/29/19,1 57 PM
Miami-Dade County Building
Product Information for N.O.A. 18-1127.18 r
i
NOA 18-1127.18tJ_(libraroductcontrollnoa118112718.p>�_
Superseded_By
File Status File Approved 2
File Classification High velocity hurricane zone REVIEWED FOR
Category Roofing CODE C®MPLIANCEI
Subcategory Modified Bitumen Roof Systems ST. LUCIE COUNTY
Material APP/SBS OCC r A
Applicant CertainTeed Corporation (�_(pc-result detail app.asp?app alias=100131)
Expiration—Date June/19/2023
Impact—Rate Unselected/Unknown F i
�+gle Copy
Maximum—Design—Pressure—Positive 0 j
Maxim um_Design_Pressure_Negative 127.5
I
Description CertainTeed Modified Bitumen Roofing Systems over Wood Decks
I
Green—Sustainable—Attributes NONE
For a detailed description on the File Status, click the NOA File Status Key_(/buildina/pc-result key app.asp)
Page Last Edited:Wed Jan 25, 2017 10:40:27 AM
I
1
f
I
I
I
MIAMI.OME
I
I
I
I
I
I
I
I
I
i
http://www.miamidade.gov/building/pc-result_app.asp?fIdNOA=18-1127....tegorylist=0&materiallist=0&impactlist=0&fldMDPP=0.00&fIdMDPN=0.00 Page 1 of 1
I
F
IAMI (y�,p�PA MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
® 00G���P�t in
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
CertainTeed Corporation
20 Moores Road
Malvern,PA 19355
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials:The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this I
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code. j
I
This product is approved as described herein, and has been designed to comply with the Florida Building Code i
including the High Velocity Hurricane Zone of the Florida Building Code.
i
I
DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
I
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in jthe
materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate'this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
I
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety. j
I
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
I
This NOA revises NOA No. 17-1003.04 and consists of pages 1 through 49.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 18-1127.18
t°t►oEcourm Expiration Date: 06/19/23
JAPPROVE
Approval Date: 01/17/19
P,ge 1 of 49
ROOFING SYSTEM APPROVAL
I
Category: Roofing
Sub-Category: Modified Bitumen
Material: APP/SBS
Deck Type: Wood
Maximum Design Pressure: -127.5 psE
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
All Weather/Empire Base 39'/8"x 65'10"; ASTM D 4601,Type Asphalt coated,fiberglass reinforced
Sheet Roll weight: 70 lbs. H base sheet.
(2 squares)
Flexiglas Base Sheet 39'/8"x 98'9"; Roll ASTM D 4601,Type Modified Bitumen coated fiberglass
weight: 90 lbs. II base sheet.
i
(3 squares)
Flintlastic Base 20 39 3/8"x 49'6"; Roll ASTM D 6163, Modified Bitumen coated fiberglass
weight: 90 lbs. Grade S, Type I base sheet.
(1.5 squares)
Flintglas Ply 4 39 3/8"x 1647";Roll ASTM D 2178,Type Fiberglass,asphalt impregnated ply sheet.
weight: 38 lbs. IV
(5 squares) UL Type G1
Flintglas Premium Ply 6 39 3/8"x 1647"; Roll ASTM D 2178,Type Fiberglass, asphalt impregnated ply
weight: 40 lbs. VI sheet.
(5 squares) UL Type G1
Flintlastic STA 393/81, x 32' 10"; Roll ASTM D 6222, Smooth surfaced All Modified
weight: 87 lbs. Grade S, Type I Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for torch
application.
Flintlastic GTA 39 3/8"x 32' 10'; Roll ASTM D 6222, Granule surfaced APP Modified
weight: 105 lbs. Grade G,Type I Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for torch
application.
Flintlastic GTA-FR 39 3/8"x 32' 10";Roll ASTM D 6222, Granule surfaced APP Modified
weight: 105 lbs. Grade G,Type I Bitumen membrane with non-woven
(1 square) polyester mat reinforcement r torch
application.
Flintlastic GMS 39 3/8"x 32' 10";Roll ASTM D 6164, Granule surfaced SBS Modified
weight: 94 lbs. Grade G,Type I Bitumen membrane with nonwoven
(1 square) polyester mat reinforcement for mop
application.
I
NOA No.: 118-1127.18
MD;� � Expiration Date-' 06/19/23
VED I Approval Date: 01/17/19
Page 2 of 49
I
I
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
I
Test Product
Product Dimensions Specification Description
Flintlastic FR-P 393/8,, x 32' 10";Roll ASTM D 6164, Fire resistant, granule surfaced SBS
weight: 101 lbs. Grade G,Type I Modified Bitumen Membrane with
(1 square) non-woven polyester mat
reinforcement for mop application.
Flintlastic Premium FR-P 393/8" x 32' 10"; Roll ASTM D 6164, Fire resistant, granule surfaced SBS
weight: 101 lbs. Grade G,Type II Modified Bitumen Membrane with
(1 square) non-woven polyester mat
reinforcement for mop application.
Flintlastic FR Dual Cap 393/8,, x 32' 10";Roll ASTM D 6162, Granule surfaced SBS modified
weight: 103 lbs. Grade G,Type H bitumen membrane with a nonwoven
(1 square) polyester/fiberglass composite mat
reinforcement for use in cold or mop
applications.
Flintlastic Cap 30 39 3/s"x 32' 10";Roll ASTM D 6163, Granule surfaced SBS Modified
weight: 86 lbs. Grade G,Type I Bitumen membrane with fiberglass mat
(1 square) reinforcement for mop applications.
Flintlastic FR Cap 30 39 3/8"x 32' 10";Roll ASTM D 6163, Fire resistant, granule surfacedi SBS
weight: 86 lbs. Grade G, Type I Modified Bitumen membrane with
(1 square) fiberglass mat reinforcement for mop
applications.
Flintlastic FR Cap 30 T 39-3/8"x 32' 10";Roll ASTM D 6163, Granule surfaced SBS Modifie'.d
weight: 100 lbs. Grade G,Type I Bitumen membrane with fiberglass
(1 square) mat reinforcement for torch
I
application.
Flintlastic Base 20 T 39-3/8"x 33'; Roll ASTM D 6163, Modified Bitumen,coated fiberglass
Weight: 81 lbs. Grade S,Type I base sheet for torch application.
(1 square)
Flintlastic Ultra Poly SMS 39 3/8" x 32' 10";Roll ASTM D 6164, Smooth surfaced SBS Modified
Base Sheet weight: 90 lbs. (1 Grade S,Type I Bitumen Membrane with non-woven
squares) polyester mat reinforcement for mop or
torched applications. j
Glasbase Base Sheet 36"x 98' 9"; Roll ASTM D 4601, Type Asphalt coated,fiberglass base sheet.
weight: 75 lbs. II
(3 squares)
Flintlastic Poly SMS Base 393/8,,x 64'3",- Roll ASTM D 4601, Modified Bitumen coated polyester
Sheet weight: 90 lbs. Grade S,Type II base sheet.
(2 squares)
I
NOA No.: 18-1127.18
Mulhtwi PROVED MY Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 3 of 49
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: j
TABLE 1 j
I .
Test Product I
Product Dimensions Specification Description
Yosemite Venting Base Sheet 39'/8" x 32'10";Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced
weight: 85 lbs. ASTM D 4897,Type buffer sheet.
(1 square) 1I
UL Type G3
Flintlastic APP Base T 39'/8"x 65' 4"; Roll ASTM D 6509 Modified Bitumen coated fiberglass
weight: 100 lbs. base sheet.
(2 squares)
Flintlastic Ultra Glass SA 393/8"x 33'11";Roll ASTM D 1970 Self-adhering, fiberglass reinforced,
weight: 73 lbs. SBS modified bitumen base/ply sheet.
(1 square)
Black DiamondTM Base Sheet 36" x 687";Roll ASTM D 1970 Self-adhering fiberglass reinforced
weight: 78 lbs. ASTM D4601 Type I modified bitumen base sheet
(2 squares)
Flintlastic SA PlyBase 39 3/8"x 66'6";Roll ASTM D 4601, Self-adhering, fiberglass reinforced,
weight: 86 lbs. Grade S, Type H I SBS modified bitumen base/pl'y sheet.
(2 squares) ASTM D 1970
i
Flintlastic SA Mid Ply 393/81,x 32'1"; ASTM D 6163, Self-adhering, polyester reinforced,
Roll weight: 62 lbs. Grade S, Type I SBS modified bitumen ply sheet.
(1 square)
F1intBond Brush 5 gallon pails ASTM D 3019 Cold applied, SBS polymer modified
asphalt adhesive.
i
I
I
i
I
I
I
I
i I
l
NOA No.: 18-1127.18
tYtu►r��anec�rmr ExpirationDate� 06/19/23
JAPPROVED1Approval Date: 01/17/19
Page 4 of 49
I
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description Manufacturer
(With Current NOA)j
F1intBoard ISO Polyisocyanurate foam insulation CertainTeed Corp.
i
FlintBoardH ISO Polyisocyanurate foam insulation CertainTeed Corp.
FlintBoard ISO Cold Polyisocyanurate foam insulation CertainTeed Corp.
ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corp.
ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp.
DensDeck Water resistant gypsum board Georgia Pacific Gypsum LLC
DensDeck Prime Water resistant gypsum board Georgia Pacific Gypsum LLC
H-Shield Polyisocyanurate foam insulation Hunter Panels LLC
ENRGY 3 Polyisocyanurate foam insulation Johns Manville Corp.,i
ENRGY 3 25 PSI Polyisocyanurate foam insulation Johns Manville Corp.'
Multi-Max FA-3 Polyisocyanurate foam insulation RMax Operating,LLC
SECUROCK Gypsum-Fiber Roof Board homogenous fiber reinforced USG Corp.
i
Structodek High Density Fiberboard High Density Wood Fiber Insulation Blue Ridge Fiberboard,Inc.
Roof Insulation board
FescoBoard Expanded erlite and fiber insulation Johns Manville CorpP P !
I
i
I
I
I
I
I
I
i
NOA No.: 18-1127.18
Muwnoeeout�rr�r Expiration Date-' 06/19/23
Approval Date: 01/17/19
Page 5 of 49
i
I
i
APPROVED FASTENERWADHESIVES:
TABLE 3
I
Fastener Product Product Manufacturer !
Number Name Description Dimensions (With Current NOA)
1. Trufast#12 DP Fastener Insulation fastener for wood various Altenloh,Brinch&Co'.U.S.,
and steel decks Inc.
2. Trufast 3"Metal Galvalume steel plate 3"round Altenloh,Brinch&Co.U.S.,
Insulation Plate Inc.
3. FlintFast#12 Coated,carbon steel screw various CertainTeed Corp.
4. FlintFast 3"Insulation Galvalume AZ50 steel plate 3"round CertainTeed Corp.
Plate
5. FlintFast#14 Insulation fastener for wood various CertainTeed Corp.
and steel decks
6. Simplex MAXX Cap Polymer fastner 1"long Simplex Nails,Inc.
7. #12 Standard Roofgrip Insulation fastener for wood various OMG,Inc.
and steel.
8. OMG 3"Galvalume Steel Galvalume stress plate 3"round OMG, Inc.
Plate
I
9. Trufast#14 HD Fastener Insulation fastener for wood various Altenloh,Brinch&Co. U.S.,
and steel decks Inc.
10. OMG Heavy Duty Insulation and membrane Various OMG, Inc.
fastener
11. 3 in.Round Metal Plate Galvalume AZ50 steel plate 3" round OMG,Inc.
12. AccuTrac Hextra Carbon steel fastener Various OMG, Inc. j
13. AccuTrac Plate Galvalume stress plate. 3"square OMG, Inc.
14. AccuTrac Flat Bottom A2-SS aluminized steel plate 3"square OMG, Inc. I
Plate
15. Millennium One Step Polyurethane two component 1.5 liters H.B. Fuller Company
Foamable Adhesive high rise insulation adhesive
16. Millennium One Step Polyurethane two component 1.5 liters H.B. Fuller Company
Green Foamable Adhesive high rise insulation adhesive 1
17. Millennium PG-1 Low Polyurethane two component 1.5 liters H.B. Fuller Company
Viscosity Insulation low rise insulation adhesive
Adhesive
18. Insta Stik Quik Set Polyurethane one component It is supplied The Dow Chemical Company
Insulation moisture curing adhesive in pressurized
cylinders with 1
a net weight
of 23 lbs.,
I
with a total
unit weight of
30 lbs.
I
NOA No.: 18-1127.18
rtu►rtwanecouHnr Expiration Date 06/19/23
Approval Date: 01/17/19
Page 6 of 49
I
I
APPROVED FASTENERS/ADHESIVES:
TABLE 3
Fastener Product' Product Manufacturer
Number Name Description Dimensions (With Current NOA)
i
19. OMG OlyBond 500 Spray polyurethane foam 10 gal.bag-in- OMG, Inc.
Adhesive insulation adhesive box set and
1.5 liters
SpotShot
cartridge
20. OMG OlyBond 500 Green Spray polyurethane foam 10 gal. bag-in- OMG,Inc.
Adhesive insulation adhesive box set and
1.5 liters
SpotShot
cartridge
APPROVED SURFACING/COATING OPTIONS:
TABLE 4
Chosen components must be applied according to manufacturer's application instructions.Any coating,fisted
below,used as a surfacing,must be listed within a current NOA.
System Number Manufacturer Application
I
1. Generic Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at
601bs/sq.
I
2. Generic Slag applied at 300 lbs/sq.,adhered with flood coat of asphalt at 60
lbs/sq.
I
3. Karnak Corp. Karnak(#97 AF)Fibrated Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq. j
4. CertainTeed Corp. FlintCoat A-150 applied at an application rate of 1.5 gal/sq.
5. Gardner Asphalt Corp. APOC#212 Fibered Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
6. Gardner Asphalt Corp. APOC#400 Sunbrite applied at an application rate of 3 gal.IAq.
I
I
I
i
i
i
i
NOA No.: 18-1127.18
MOVE�� Expiration Date- 06/19/23
APPRApproval Date: 01/17/19
Page 7 of 49
I
EVIDENCE SUBMITTED:
Test Agency/Identifier Name Report !Date
i I
Factory Mutual Research Corp. FM 4470 3Y8ALAM 03/23/96
FM 4470 OD3A3.AM 04/04/97
FM 4470 1D7A4.AM 11/09/98
FM 4470 2DOAO.AM 12/23/98
FM 4470 3024311 11/01/06
FM 4470 3031350 09/27/67
FM 4470 3036182 07/31/09
FM 4470 3039046 06/15/40
FM 4470 3048520 09/19/;13
Underwriters Laboratories,Inc. UL 790 R11656 01/11/13
United States Testing Company ASTM D 5147 97-457-2R 12/02/87
ASTM D 5147 97-457-4 06/03%88
i
Momentum Technologies,Inc. ASTM D 6164 AX31G8F 06/05/09
TrinitylERD TAS 114(J) 3507.08.99-1 04/18%01
TAS 114(J) 3504.06.01-1 06/05/01
TAS 114 3521.07.04 07/29%04
TAS 114 3533.01.06 01/06/06
TAS 114(H) Letter 04/05/06
TAS 117 (13) 3503.10.06 10/10/06
TAS 117 (13) 06490.04.07-R1 06/27/07
TAS 117 (B)/ASTM D 6862 C8500SC.11.07 11/30/07
FM 4470,TAS 114,FM 4470, C8370.08.08-R1 10/05/09
TAS 114(J)
I
TAS 114(H), TAS 117(B),TAS C30560.06.10 06/10/10
114(J)
FM 4470,TAS 114 C32830.07.10 07/20/10
ASTM D 6164/D 4798 C31410.01.11-2 01/10/11
TAS 117 B C35500.02.11 02/09/11
FM 4470 (K)/TAS 114(J) 03515.07.03-1-R1 06/217/12
ASTM D 1876,TAS 114(H), C42110.08.12 08/13/12
TAS 117(B)
FM 4474/TAS 114 C39670.08.12 08/20/12
ASTM D 4601 C40050.09.12-1 09/28/12
ASTM D 1970 C40050.09.12-2 09/28/12
ASTM D 5147/D 4798 C31410.10.10-R1 11/61/12
ASTM D 5147/D 4798 C31410.01.11-1-R1 11/61/12
ASTM D 4798 C31410.01.11-2A-Rl 02/21/13
ASTM D 4798 C31410.12.13 12/05/13
ASTM D 6222 C40050.12.13-R1 12/31/13
TAS 117,TAS 114 C30310.12.09-R1 03/07/14
ASTM D 2178 C47250.03.14 03/26/14
ASTM D 1876,TAS 114(H), C45620.03.14 03/27/14
FM 4474
NOA No.: 18-1127.18
M
APPROVED
cout�r�r Expiration Date: 06/19/23
ApproN,al Date: 01/17/19
Plage 8 of 49
l -
' l
I
EVIDENCE SUBMITTED:
Test Agency/Identifier Name Report Date!
ASTM D4601 CTR-SC8740.04.15-R2 04/21/15
ASTM D 1876, TAS 114(H), C47320.03.14-R1 04/01!15
FM 4474
ASTM D 1876 C35460.05.11-R1 05/20/15
FM 4474(D)/UL 1897/TAS CTR-SC10420.01.16 01/25/16
114(J)
FM 4474!TAS 114(J) CTR-SC9175.09.16-2 09/06/16
FM 4470(K)/UL 1897/TAS CTR-SC11590.08.16- 09/06/16
114(J) R1
ASTM D 4601-04(2012),Type 11 CTR-SC 11145.09.16- 09/19/16
3C
ASTM D 4601-04(2012),Type 11 CTR-SCI 1145.09.16- 09/19/16
3A
ASTM D 6163 CTR-SC 11145.09.16- 09/19/16
5A
ASTM D 6222 CTR-SCI 1145.09.16- 09/19'/16
7A
PRI Construction Materials ASTM D 6163 CTC-056-02-01 08!25%10
Technologies LLC ASTM D 6163 CTC-066-02-01 08/09!11
ASTM D 6222 CTC-071-02-01 08/08/11
ASTM D 6164/D 4798 CTC-093-02-01 08/04/11
ASTM D 4601 CTC-126-02-01 03/12/12
ASTM D 2178 CTC-123-02-01 03/13/12
ASTM D 4601 CTC-127-02-01 03/13/12
ASTM D 6163 CTC-128-02-01 06/11/12
ASTM D 6163 CTC-129-02-01 06/11/12
ASTM D 6164 CTC-132-02-01 06/11/12
ASTM D 6164 CTC-161-02-01 05/09/13
ASTM D 6162 CTC-183-02-01 10/02/13
ASTM D 6164 CTC-190-02-01 12/02/13
ASTM D 1970 CTC-199-02-01 01/22/14
ASTM D 6163 CTC 319-02-01 08/22/17
i
I
I
i'
NOA No.: 18-112718
��OVEDI—t Expiration Date: 06/19/23
Approval Date: 01/17/19
Page 9 of 49
Membrane Type: APP Modified
Deck Type 1: Wood;Non-Insulated
I
Deck Description: 19/32"or greater plywood or wood plank attached with 8d ring shank nails spaced 6"o.c. at
wood joists spaced maximum 24"o.c.
System Type E(3): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet,Yosemite Venting Base Sheet, Flexiglas Base
Sheet,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet,Glasbase IBase
Sheet r Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening#1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: One ply of All Weather/Empire Base Sheet,Flintlastic Ultra Poly SMS Base Sheet, Glasbase
(Optional) Base Sheet,Flexiglas Base Sheet,Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a,full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one
ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic STA
or Flintlastic APP Base T torch adhered.
Ci
Membrane: Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf. (See General Limitation#7)
i
Pressure:
I
I
I
i
i
i
i
I
I
I
I
I
i
I
NOA No.: 18-1127.18
MIAM1�14DECOUN7Y
Expiration Date: 06/19/23
Approval Date: 01/17/19
Paige 27 of 49
I
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory ifor fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4'x 4'maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. "Asphalt
application of either system shall be at a minimum rate of 121bs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer,Registered Architect, or Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA, General Limitation 09 will not be applicable.)
8. All attachment and sizing of perimeter nailers,metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.,field,,'
perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA, General Limitation#7 will not be applicable.)
i
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
I
END OF THIS ACCEPTANCE
i
NOA No.:j18-1127.18
Mu►rtwraoecourJrir Expiration Date: 06/19/23
JAPPROVEDIApproval Date: 01/17/19
Page 49 of 49