HomeMy WebLinkAboutBuilding Permit Application ALL APPLICABLE INFO)jMUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: ` / 'c Permit N ARIF , ' 1� I ��'qa �s�.�_ ..
I✓ , s ra x
FEB 12, 2020
Building Permit Applicat'm
Planning and Development Services
e�mitting De�pal�t�rlent
Building and Code Regulation Division St. Lucie County, FL
2300 Virginia Avenue,Fort Pierce FL 34982
Phone: (772)462-1553 Fax: (772)462-1578 Commercial X Residential
PERMIT APPLICATION FOR: S u h tter
I?ROl?OSED If iPROVEIVIIrNT LOCATIC}N '
Address: 10152 S OCEAN DR 213B
Legal Description: ATLANTIS CONDOMINIUM BLDG B UNIT213B AND PRO-RATA SHARE IN COMMON ELEMENTS
Property Tax ID#:.4502-803-0010-000-1 Lot No.
Site Plan Name: Block No.
Project Name: Slichko
Setbacks Front Back: X Right Side: Left Side:
ET i
n
�-
OF 1NpRK} ,
y, 4 .
Install 1 accordion shutter
x
C�NSTRUCTIUN,INFORIVIATIO,N „
a.
s,
Additionalwork t0e performed under this permit—check a appy:
HVAC E]Gas Tank Gas Piping Shutters Q Windows/Doors
Electric ❑ Plumbing Sprinklers Generator Roof Roof pitch
Total Sq. Ft of Construction: S Ft.of First Floor:
Cost of Construction:$ 1,098.00 Utilities:Sewer I]Septic Building Height:
QWNER/LESSEE CONTRACTOR
I
Name George Slichko Name: Michael Heissenberg
Address:10152 S Ocean DR Apt 213B Company: Expert Shutter Services
City: Jensen Beach State:FL Address: 668 SW Whitmore Dr
Zip Code: 34957 Fax: City: Port Saint Lucie State:FL
Phone No.772-229-9498 Zip Code: 34984 Fax: 772-871-0990
E-Mail: Phone No. 772-871-1915
Fill in fee simple Title Holder on next page( if different E-Mail: Callexpert@aol.com
from the Owner listed above) State or County License: 16572
If value of construction is$2500 or more,a RECORDED Notice of Commencement is required.
SUPPLEMENtAL GpNSTR�ICTION LIEN ILA1N INIQRMATION
A
DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: x Not Applicable
Name: Tilteco Inc. Name:
Address:6355 NW 36th St Suite 305 Address:
City: Virginia Gardens State: Fl_ City: State:
Zip: 33166 Phone: Zip: Phone:
FEE SIMPLE TITLE HOLDER: x Not Applicable BONDING COMPANY: _Not Applicable
Name: Name:
Address: Address:
City: City:
Zip: Phone: Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit,I do hereby agree that I will,in all respects, perform the work
in accordance with the approved plans,the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review:room additions,
accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use
WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing, consult with lender or an attorne before
commencingwork or our Noti sof Commencement.
�
s
p 6ignature of Owner/Lessee/Contractor as Agent for Owner Signature of Contractor/License HolderRDq
U o ��
t m o %TATE OF FLORIDA STATE OF FLORIDA
o a LL EOUNTY OF St.Lucie COUNTY OF St.Lucie
O M UJfn Ir
o � Q •Jhe forgoing instrument was acknowledged)iefore me The forgoing instrument was acknowledged before me a 3 p =
co Z co 'phis (� day of 09cul Q M 20 _by this l�day of Rmi 20 by D o
Op\ATIO T� C -n - O
5
r� N C CQ
aichael Heissent�rg Michael Hsissenberg tD m
r�ybo�ho Name of person acknowledging) (Name of person acknowledging) N n
(Signature of Notary Public-State of Florida) (Signature of Notary Public-State of Florida)
Personally Known x OR Produced Identification Personally Known x OR Produced Identification
Type of Identification Produced Type of Identification Produced
Commission No. GG258038 (Seal) Commission No. GG258038 (Seal)
Revised 07/15/2014
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
COMPLETE
INITIALS
6-x i l/2"x a07S-,HNC!{ 7' ; INSTALLATIONS HV BLADE & HV CENTERMATES � -X2.000"Max.;
Min,'A A-653 Cf7A0E i0 Min. YARIo. p p
MET SIIUGALV.STEEL 2 MIx.� INTO METAL STUD WALLS * ° ' — -�
METAL StU05 AT ta-D,C, � 43b y1' ,
a'
---- --- I m 6 o.c, 40 4 3o 11/4"e/ NOMINAL
` ----_ /2" - v * ENERAL LIMITATIO
NS AND CONDITIONS OF USE ALUMINUM SLEEVE
(13/4'.6 1/rx 0035-THICK MIn.! 43c _ 430 _ f2 6063-75 ALLOY
T, • MUM INSTALLATION TO METAL STUD WALLS •o
CaYT.CALV.STEEL.TRACK CHANNEL,i O 6.O.C. O 6-O.C. r
ASTM A-653 GRADE 40 MI.0-60 I ---� SEPARATION TO GLASS SCHEDULE '^ 3.000'
GALVANIZED FASTENED TO STUDS I i! I Mox.
WJ/(2)16.1/2•TEK SCREWS ON , E+snTIC€1NISN 3g �a 1. MAX. A.S.D. DESIGN PRESSURE RATING: +75, - 75 (psf}
n17CRWR a EXTERIOR FACE I AS ArPuca9LE T 2. MAX. SHUTTER SPAN: 84" MINIMUM
WIND ZONE
I ' ASTM E-1996 SEPARATION a7< LENCTH I. ,'
EXISTING CLASS MIN.SEPARATION , 3. ALLOWED MOUNTING: MS ON THIS SHEET. TO GLASS
(SEE S CLASS
213 N 1 THRU 3 I• 43 ,1,/4"0--20X3" BOLT
(�) 4. ONLY-CENTERMATE 2l W/ 24 HV LOCK ARE ALLOWED MUST PENETRATE e T"
WITH 2l ARRANGED A METRICAL LAYOUT.
J e USE OF (2)�35}(6° LONG, MINIMUM) MUST ALWAYS BE a 4° _
7 3/4'x 6 1/4-x 0.035'THICK W'd ExIST1Nc FINISH ' f -, INCLUDED AT-EXTERIOR OR INTERIOR ACCESS SIDE OF 256' 373
CARE.CAW.SIO:L TRACK CHANNEL.I As APPUCABLE ,, =I! CENTERMATE. � _ �..�.o
ASTM A ALV. GRADE 40 Min,O-210 I
GAWIU;GED FASTENED TO SRJOS n"(""—"•"" ,moo
W/(2)10x7/2-TEX SCRI511 ory 43c 430T.
INTER76R A,EXTERIOR FACE O 6"a.C. 6 6.O.C. '. 1/4-0-20 THREADS
.e BLADE SLACK DETAIL HVF IS ALSO VALID�FO,R 43 1/4"0 ELCO CON ,•UCnQN
t/2' !2 38 CENTERMATE 21 APPLICATION WITH BLADE I'J PRODUCTS FAB-LOK HD
6-x 1 1/2"x 0.075'THICK w -!'.VAWE§.•`• _43b
Mtn.ASTM A-653 GRADE 4D ':x..,a�.. . 6" o.c. COMPONENTS
Min.G-ro CALM.STEEL t" M$ WALL HEADER/SILL INSTALLATION EXISTING FINISH AS APPLICABLE SCALE: 3/8"- 7"
ML7AL STUDS AT 16"O.C. 1.1in. ..'.�
(TYP.TOP t<BOTTOM)
4^ 7 3/4'x fi TJi`x 6.435"THICK M;n,
C-———'— — CONT.ca,M.STEEL TRACKCHANNEL
�EXISANG GLASS - - - _ - ASTM A-653 GRADE 40 Min.G-60
,..,,.- .. - OALVAH]ZED FASTENED TO STUDS
- `SYMMETRYCAL I I
:L ' 1 1 1 1 1 W
I I 4.34 4Jb Qac r I 17`;•,.:' I , "I SYMME7�2,YCAL •°! I ` ' MIH.SEIMA71ON VARIES , 1 /(2)16x7/2"TEN SCREWS ON
---I! I ------- SIDE ! !!----- ---------
INTERIOR EXTERIOR FACE
£ -To
GLASSCENTERMATES W/ . (SEE SCHEDULE) Max.
INTERIOR ACCESSSIDE'EX IDR ACCESS - ---- -- ----- - --- -----------------
--
- ------------ --------- ------ --------
-----
--___-- -------- 6'(EYP.) IN 3 (6~Min.) IN e} I
_------_ ------_—_ ------------- _-- _ 24 -----------------------_ -_-------—_—_-__ 12
--- ;------ ---. '- ____== ---
---___—_--------- --- --- - - -- `— - _
- - - ___ -� A -- - -_-
21 21 21 21 1^- LdCATLOAT�12
r HV HEADER/S L E1l0S
- ^-- - - --- - --"—- -
------ — - ---- - - - EW-Y
12 7 t/a'{TyP.) 3 (6"Mia? 24 t( SIDE CONNECTION TO TRACK
(Cont.) _ _ 8 1f2"(TYp,} _ _ _ 7" • 7" 6 7/2`MAX.SLACK *'k--•t
�/A HVB BLADE SLACK DETAILAYE 1 C FLORIDA BUILDING CODE(Non High Velocity Hurricone Zone
,110Ap ?'�� +'L 02OT7 TILTECO.INC. 02017 EASTERN METAL SUPPLY.INC.
----- � BERTHA H
` ME-C o 1 H C. A.S u S■ ■ Accordion Shutter System
H.V.RADE#1 W/OR W/0 N.V.WWW BLADE
*t l/// 7 i : TILUr TESTING k ENGINEERING COMPANY American Shutter $y3I6m3 EM,N DESCRIPTIONoatt naAxT7 BY. Lc.
i 6355 N.w.3CIn.St,Sts.343,MRranu Gu+as,s,F=03316Association, Inc. I OLD m-095 7/27J7 DATE: 07/27/17
443 ---S,Film nr Phnn<:(2105)1177-1530.Fax:(305)871-7537 4268 Westroads Drive 2 DRAWING No
r t
< a:nu«<o«+.«m West Palm Beach, FL 33407 3 -}
'•_cif'£'' CViIIvT:'r\Cw1.tL ED-OW67111 1/-107
•qqt 4 V WALTER A 71L1 T Jr.P.E.4
EfijTt7EjDATE FLormA tIr 1:,767 6 SH 2O
F.E. SOF 20