Loading...
HomeMy WebLinkAboutPERMIT PACKAGE (005)WINDOW/DOOR INSTALLATION 1107 NETTLES BLVD Jensen Beach, FL34957 4502-501-1294-000-5 RODERMAN REPLACE 6 WINDOWS WITH IMPACT. USING LIKE SIZES. NO STRUCTURAL CHANGES BEING MADE. 5650 Kenneth & Nicki Roderman BRUCE M. TYRRELL, JR 1107 Nettles BLVD KAMRELL WINDOWS & DOORS Jensen Beach 2201 SE INDIAN ST BLDG Q-4 34957 STUART FL 972-975-8298 34997 772-288-6208 ken.roderman@gmail.com 772-288-6205 ADMIN@KAMRELL.COM CGC061180 02/14/2020 RODERMAN 1107 NETTLES BLVD JENSEN BEACH,FL EXPOSURE C RF HGT 25 ZONE 4 #5 #6 2ND FLOOR MAIN FLOOR #1 #2 GROUND FLOOR #3 #4 #'s 1,2-CGI SERIES 110 SINGLE HUNG 36.75 X 37.50 +42.3/-45.9 17-1018.08 DP +75/-75 #'s 3,4- CGI SERIES 110 SINGLE HUNG 36.75X 50.375 12.86 SQ FT +42.3/-45.9 17-1018.08 DP +75/-75 #5-CGI SERIES 238 SN PROJECT OUT 26.25 X 37.50 6.84 SQ FT +42.3/-45.9 17-0918.06 DP +110/-137.5 #6-CGI SERIES 238 SN PROJECT OUT 26.25 X 38.125 6.95 SQ FT +42.3/-45.9 17-0918.06 DP +110/-137.5 WINDOW/DOOR SCHEDULE APPROX IGNATION IMPACT PROTECTION ID OPENING ** DESIGNATION IMPACT NEW * REMARKS NO SIZE TYPE GLASS EXISTING (WXH) SHUTTER SHUTTER 1 36.75 X 37.50 CGI SERIES 110 SH X 17-1018.09 DP +75/-75 2 36.75 X 37.50 CGI SERIES 110 SH X 17-1018.09 DP +75/-75 3 36.75 X 50.375 CGI SERIES 110 SH X 17-1018.09 DP +75/-75 4 36.75 X 50.375 CGI SERIES 110 SH X 17-1018.09 DP +75/-75 5 26.25 X 37.50 CGI SERIES 238 AWN X 17-0918.06 DP +110/-137.5 6 26.25 X 38.125 CGI SERIES 238 AWN X 17-0918.06 DP +110/-137.5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 *Window Replacement using existing shutters to comply with impact protection will require the existing shutters to meet the requirements of the 2010 FBClResidential R301.2.1.2 TOTAL GLAZED OPENING AREA FOR 8TRUCTURE: 8.F. PERCENTAGE OF NEW GLAZED AREA: (TOTAL INSTALLED GLAZED AREA DIVIDED BY TOTAL GLAZED OPENINGS FOR STRUCTURE) NOTE: The replacement of more than 25 of the aggregate area of exterior glazing (windows & doors) in one & two family dwellings within a 12 month period will require impact protection on all proposed glazed opening replacement (approved shutters or impact resistant glazing) as per 20 I 0 FBCI EXISTING BUILDING 606.4. ** TYPE WINDOWS SH – SINGLE HUNG AWN – AWNING SL – SLIDING DR – DOUBLE HUNG CAS – CASEMENT FIX – FIXED RODERMAN 1107 NETTLES BLVD JENSEN BEACH, FL Building height Zone 4 I Area 15 20 25 30 35 40 45 50 55 60 10 pos 37.9 40.4 42.3 43.8 45.4 46.7 47.9 48.9 49.8 50.7 neg 41.1 43.8 45.9 47.5 49.2 50.6 52 53 54 55 20 pos 36.3 38.7 40.5 42 43.5 44.7 45.9 46.8 47.7 48.6 neg 39.4 42 44 45.6 47.2 48.5 49.8 50.8 51.8 52.8 50 pos 35.4 37.7 39.4 40.9 42.4 43.5 . 44.7 45.6 46.5 47.3 neg 37.1 39.6 41.4 42.9 44.5 45.7 46.9 47.8 48.7 49.7 \100 pas 32.2 34.4 36 37.3 38.6 39.7 40.8 41.6 42.4 43.2 neg 35.4 37.8 39.5 41 42.5 43.6 44.8 45.7 46.6 47.4 500 pas 28.2 30.1 31.5 32.7 33.8 34.8 35.7 36.4 37.1 37.8 neg 31.4 33.5 35.1 36.4 37.7 38.7 40.5 39.7 41.3 42.1 Building height End zone 5 15 20 25 30 35 40 45 50 55 60 10 pas. 37.9 40.4 42.3 43.8 45.4 46.7 47.9 48.9 49.8 50.7 neg 50.7 54.1 56.6 58.7 60.8 62.5 64.2 65.4 66.7 67.9 20 pos 36.3 38.7 40.5 42 43.5 44.7 45.9 46.8 47.7 48.6 neg 47.3 50.5 52.8 54.8 56.7 58.3 59.8 61 62.2 63.4 50 pos 35.4 37.7 I 39.4 40.9 42.4 43.5 44.7 45.6 46.5 47.3 neg 42.8 45.6 47.7 49.5 51.2 52.7 54.1 55.1 56.2 57.3 100 pos 32.2 34.4 36 37.3 38.6 39.7 40.8 41.6 42.4 43.2 neg 39.4 42 44 45.6 47.2 48.5 49.8 50.8 51.8 52.8 500 pos 28.2 30.1 31.5 32.7 33.8 34.8 35.7 36.4 37.1 37.8 neg 31.4 33.5 35.1 36.4 37.7 38.7 39.7 40.5 41.3 I 42.1 Wind design Pressure Chart for structures subject to Florida Residential Code 170 mph exposure C Wall component and Cladding pressures from Table R302.2(2) modified by adjustment factors from R301.1(3). Converted to Vasd according to R302.1.2.1.1 RODERMAN 1107 NETTLES BLVD JENSEN BEACH, FL