HomeMy WebLinkAboutNOA RFCFt�Fo
perrn;tt; Oly
o
MIAMI-D,4DE �n NO bunt, ,,e"t - MIAM-DADE COUNTY
a PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
GAF
1 Campus Drive
Parsippany,NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control
Section to be used in Miami-Dade County and other areas where allowed Ay the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control
Section(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have
this product or material tested for quality assurance purposes.If this product or material fails to perform in the
accepted manner,the manufacturer will incur the expense of such testing end the AHJ may immediately revoke,
modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke
this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material
fails to meet the requirements of the applicable building code. '
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Liberty*"SBS Self-Adhering Modified Bitumen hoofing Systems Over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and
following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of thil NOA as an endorsement of any product,
for sales;advertising or any other purposes shall automatically terminate As NOA.Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA. t
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be
done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the BuildiAg Official.
This NOA renews and revises NOA No. 15-0203.05 and consists of pages-1 through 18.
The submitted documentation was reviewed by Jorge L. Acebo. File C®PY�
1
NOA No.: 16-1206.02
Expiration Date: 02/22/22
_1,Aan0 coutarir Approval Date: 02/16/17
Page 1 of 18
i
1
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Category: Modified Bitumen
Material: APP/SBS
Deck Tyne: Wood 1'
Maximum Design Pressure: -60 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LA4ELED BY APPLICANT:
TABLE 1
Test - Product
_ Dimensions Specific tion Descri tion
Liberty""S Se -Adher' .375"x 66' D4601 Self-adhered, SBS.mod base or
ase1 beet plyshee wi glass reinfo -
Libertys"MA Mechanically 39.375"x 66' ASTM D4601 SBS base sheet with a glass
Attached Base Sheet reinforced mat coated with a
of er-modified asphalt.
Liberty'SBS Self-Adhering 39.375"x 34' ASTM D6164 Granule surfaced self-adhering SBS
Cap Sheet modified membrane reinforced with
polyester mat,coated with polymer-
modified asphalt.
GAFGLAS'Ply 4 39.37" ASTM D2178 Type IV asphalt impregnated glass
(1 meter)Wide felt with asphalt coating.
Tri-Ply®Ply 4 39.37" ASTM D2178 �ype IV asphalt impregnated glass
(1 meter)Wide felt with asphalt coating.
GAFGLAS®FlexPly'" 6 39.37" ASTM D2178 Type VI asphalt impregnated glass
(1 meter)Wide felt with asphalt coating.
e
GAFGLAS®#75 Base Sheet 39.37" ASTM D4601 irype II,asphalt impregnated and
(1 meter)Wide ,coated glass mat base sheet.
Tri-Ply®#75 Base Sheet 39.37" ASTM D4601 -Type II,asphalt impregnated and
(1 meter)Wide coated glass mat base sheet.
GAFGLAS®#80 Ultima"Base 39.37" ASTM D4601 Type H,asphalt impregnated and
Sheet (1 meter)Wide coated,fiberglass base sheet.
GAFGLAS®Strataven& 39.37" ASTM D4897 A nailable,fiberglass base sheet
Eliminators"Nailable Venting (1 meter)Wide coated on both sides with asphalt.
Base Sheet Surfaced on the bottom side with
mineral granules embedded in
asphaltic coating.
Ruberoid® 39.37" ASTM D6163 SBS modified asphalt base sheet
SBS Heat-Welds'25 (1 meter)Wide reinforced with a glass fiber mat and
smooth surfaced.
W
I NOA No.: 16-1206.02
Expiration Date: 02/22/22
CDADECOURS Approval Date: 02/16/17
Page 2 of 18
I -
1
Test Product
Product Dimensions Specification Description
Ruberoid® 39.37" ASTM D6164 Non-woven polyester mat coated with
SBS Heat-Weld"Smooth (1 meter)Wide SBS polymer-modified asphalt and
smooth surfaced.
Ruberoid® 39.37" ASTM D6164 Non-woven polyester mat,coated with
SBS Heat-Weld'Granule (1 meter)Wide SBS polymer-modified asphalt and
surfaced with mineral granules.
Ruberoid® 39.37" ASTM D6164 Non-woven polyester mat coated with
SBS Heat-Weld" 170 FR (1 meter)Wide fire retardant SBS polymer-modified
asphalt and surfaced with mineral
granules.
Ruberoid® 39.37" ASTM D6164 Non-woven polyester mat coated with
SBS Heat-Weld"Plus (1 meter)Wide SBS polymer-modified asphalt and
surfaced with mineral granules.
Ruberoid® 39.37" ASTM D6164 Von-woven polyester mat coated with
SBS Heat-Weld""Plus'FR (1 meter)Wide fire retardant SBS polymer-modified
isphalt and surfaced with mineral
granules.
Ruberoie EnergyCap'SBS 39.37' ASTM D6164 ton-woven polyester mat coated with
Heat-Weld'Plus FR (1 meter)Wide 'Fire retardant SBS polymer-modified
%sphalt and surfaced with mineral
granules with factory applied
EnergyCote'.
Ruberoid®Torch Smooth 39.37" ASTM D6222 Non-woven polyester mat coated with
(1 meter)Wide APP modified asphalt and smooth
surfaced.
Tri-Ply®TP-4 39.37" ASTM D6222 Non-woven polyester mat coated with
(1 meter)Wide APP modified asphalt and smooth
surfaced.
Ruberoid Torch Granule 39.37" ASTM D6222 Non-woven polyester mat coated with
(1 meter)Wide APP modified asphalt and
surfaced with mineral granules.
Tri-Ply®TP-4G 39.37" ASTM D6222 Non-woven polyester mat coated with
(1 meter)Wide APP modified asphalt and
Surfaced with mineral granules.
Ruberoid®Torch FR 39.37" ASTM D6222 Non-woven polyester mat coated with
(1 meter)Wide dire retardant APP modified asphalt
i�urfaced with mineral granules.
Ruberoid®EnergyCap'M Torch 39.37" ASTM D6222 ,APP modified cap membrane with a
Plus FR (1 meter)Wide torch grade bottom surface and a
mineral granular top surface coated
with factory applied EnergyCote'.
NOA No.: 16-1206.02
Expiration Date: 02/22/22
wu�rtt Dane courrrr AVEDpproval Date: 02/16/17
APPR� Page 3 of 18
Test Product
Product Dimensions Specification Description
Ruberoid®EnergyCap''Torch 39.37" ASTM D6222 APP modified cap membrane with a
Granule FR (1 meter)Wide torch grade bottom surface and a
mineral granular top surface coated
with factory applied EnergyCote'.
Ruberoid®20 39.37" ASTM D6163 SBS polymer-modified asphalt base
(1 meter)Wide sheet reinforced with a glass fiber
mat.
Ruberoid®Mop Smooth 39.37" ASTM D6164 ilon-woven polyester mat coated with
(1 meter)Wide (BS polymer-modified asphalt and
�mooth surfaced.
Ruberoid®Mop Smooth 1.5 39.37" ASTM D6164 Non-woven polyester mat coated with
(1 meter)Wide SBS polymer-modified asphalt and
smooth surfaced.
Ruberoid®Mop Plus Smooth 39.37" ASTM D6164 Non-woven polyester mat coated with
(1 meter)Wide SBS polymer-modified asphalt and
aced.
GAFGLAS®Mineral Surfaced 39.37" ASTM D3909 Asphalt coated,glass fiber mat cap
Cap Sheet (1 meter)Wide sheet surfaced with mineral granules
Tri-Pl Minera STM D3909 Asphalt coated, ass fiber mat cap
Cap Sheet (1 meter)Wide sheet surfaced with mineral granules.
GAFGLAS®EnergyCap" 39.37" ASTM D3909 Asphalt coated,glass fiber mat cap
BUR Mineral Surfaced Cap (1 meter)Wide sheet surfaced with mineral granules
Sheet and factory applied EnergyCoten''.
VersaShield®Fire-Resistant 42" X 100' ASTM D 226 Non-Asphaltic fiberglass based
Roof Deck Protection rolls underlayment and/or fire barrier.
WeatherWatch®XT 36"x 50' rolls ASTM D1970 Mat surfaced SBS modified,
36"x 66.7' Vberglass reinforced,bituminous
rolls 1heet material used as a leak barrier
;inderlayment.
StormSafe"Anchor Sheet 40"Wide ASTM D4601 ;,Synthetic anchor sheet.
Topcoat®Surface Seal SB 5 or 55 gallons ASTM D6083 Solvent based sprayable thermoplastic
rubber sealant designed to protect and
restore aged roof surfaces and to
increase roof reflectivity.
Topcoat®Membrane 1,5 or 55 ASTM D6083 An acrylic,water based elastomeric
gallons membrane system designed to protect
various types of roof surfaces.
Topcoat®MB Plus 5 or 55 gallons Proprietary Water based,low VOC primer used to
block asphalt bleed-through.
NOA No.: 16-1206.02
Expiration Date: 02/22/22
nu►r�wAn�courrry Approval Date: 02/16/17
Page 4 of 18
e
€1
Test Product
Product Dimensions Specification Description
Topcoat®F1exSeal 1, 5 gallons or Proprietary �olvent based flashing compound for
1 qt.tube titers and other detailing.
Topcoat®FireOut"Fire 5 or 55 gallons ASTM D6083 -ow VOC,water-based fire barrier
Barrier Coating �oating.
APPROVED INSULATIONS:
TABLE 2
Manufacturer
Product Name Product Description (With Current NOA)
EnergyGuard'Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuard7 RA Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuard-RH Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuard-RN Polyiso Insulation Polyisocyanurate foam insulation GAF
DensDeck®Roof Board Gypsum board Georgia-Pacific Gypsum LLC
DensDeck®Prime®Roof Board Gypsum board Georgia-Pacific Gypsum LLC
i
Securock'Gypsum-Fiber Roof Board Gypsum board United States Gypsum
Corporation
f
L NOA No.: 16-1206.02
Expiration Date: 02/22/22
Muwxo�courta�r Approval Date: 02/16/17
Page 5 of 18
i
y
e
z
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1. Drill-Tec'#12 Fastener Carbon steel fastener used Various GAF
in steel or wood decks.
2. Drill-Tec'#14 Fastener Carbon steel fastener used Various GAF
in steel,wood or concrete
decks.
3. Drill-Tec'°'ASAP®3S Drill-Tec'#12 fastener V#rious GAF
with Drill-Tec''3" 4
Standard Steel Plate. IF
4. Drill-Tec' Round galvalume plated 3"round GAF
3"Steel Plates steel stress plate with
reinforced ribs for use e
with Drill-Tec'"fasteners. !
5. Drill-Tec' Round galvalume stress 3round GAF
3"Standard Steel Plates plate used with Drill-
Tee''fasteners.
6. Drill-Tec'AccuTrac® Galvalume steel plate for 3"x 3" GAF
Recessed Plates use with Drill-Tec'
fasteners.
7. Drill-Tec'AccuTraO AZ-SS aluminized steel 3"x 3" GAF
Flat Plates plate for use with D ill-
Tee'#12 Fastener,Drill-
Tee''#14 Fastener and
Drill-Tec'"XHD
Fastener.
8. Annular Ring Shank Galvanized steel Naik Minimum Generic
Nails&Tin Caps Ring shank roofing nails J2 Ga. (Dade County Approved)
with Galvanized steel tin Variyus lengths
caps. Tia Caps:
Minimum 32 Ga.
1%"j)iameter
!
x
NOA No.: 16-1206.02
Expiration Date: 02/22/22
C4MHUM
onn'cou
MY YY Approval Date: 02/16/17
Page 6 of 18
I
9
EVIDENCE SUBMITTED:
Test Agency Name Report Identifier Date
IRT-ARCON,Inc. TAS 114 q 02-005 01/18/02
TAS 114 02-014 03/22/02
UL LLC UL 790 p R10689 03/14/13
UL 790 R1306 05/22/13
Factory Mutual Research Corp. 4470 3024805 11/20/06
4470 3036225 08/10/09
4470 3035140 08/10/09
4470 3040738 11/16/10
4470 0 3036980 08/14/09
4470 4 3044688 03/16/12
4470 1 3038278 11/18/11
4470 . 3032811 12/11/08
4470 797-03221-267 09/24/07
Trinity ERD ASTM D4897 G34140.04.11-5-R3 06/04/15
ASTM D4601 G121110.12.08 12/02/08
ASTM D4601 G34140.04.11-4-R2 06/04/15
ASTM D6163 634140.04.11-2 04/25/11
ASTM D6862 C8500SC.11.07 11/30/07
ASTM D6164 G33470.01.11 01/13/11
ASTM D6164 G31360.03.10 03/31/10
ASTM D6222 G43190.11.13-1 11/15/13
ASTM D6222 G43190.03.14-2 03/06/14
ASTM D6222 043190.03.14-1 03/06/14
ASTM D6163 G40630.01.14-1 01/06/14
ASTM D6164 GA0630.01.14-2A 01/07/14
ASTM D6164 G40Z;30.01.14-2B-Rl 01/16/15
ASTM D6164 G40630.01.14-2C 01/07/14
ASTM D6164 G46160.09.14-3B 09/09/14
ASTM D6164 G40630.03.14 03/06/14
ASTM D6164 G40630.01.14-2A-1-Rl 04/10/14
ASTM D4601 (303180.01.14-1 01/10/14
ASTM D6164 &43180.03.14 03/03/14
ASTM D6164 Gt6850.08.08-R1 04/14/11
ASTM D6222 136850.11.08 11/05/08
ASTM D6222 :6850.10.08 10/06/08
ASTM D3909 G43610.01.14 01/22/14
ASTM D3909 G30250.02.10-3-R2 06/03/15
ASTM D3909 SC6870.08.14-R1 09/04/14
ASTM D6222 G40620.07.12-2 07/17/12
ASTM D6163 G12210.06.09 08/03/09
ASTM D6222 G30250.02.10-2 05/11/10
Exterior Research and Design,LLC TAS 114 18035.12.02-2 12/24/02
TAS 114 01501.04.03 04/03/03
TAS 114 01516.04.06 04/20/06
TAS 114 G4280LAB.10.06 10/20/06
!
NOA No.: 16-1206.02
uni�y Expiration Date: 02/22/22
CMbkml-�EcoApproval Date: 02/16/17
Page 7 of 18
x
4
EVIDENCE SUBMITTED: (CONTINUED)
Test Agency Test Name Report Identifier Date
Atlantic&Caribbean Roof TAS 114 A 07-079 12/13/07
Consulting,LLC TAS 114 t 08-044 07/01/08
PRI Construction Material ASTM E96 GtAF-306-02-01 07/07/11
Technologies LLC ASTM E2178 G-AF-276-02-01 01/04/11
ASTM D2178 GAF-314-02-01 08/23/11
ASTM D2178 GAF-315-02-01 08/23/11
ASTM D226 GAF-270-02-02 11/15/10
ASTM D226 GAF-349-02-01 07/03/12
ASTM D1970 GAF-324-02-01 11/30/11
ASTM D6083 GAF-498-02-01 01/06/16
ASTM D6083 GAF-499-02-01 03/12/14
ASTM D6083 G�F-500-02-01 03/12/14
ASTM D6083 G 276-02-01REV 01/03/11
ASTM C1289 CIAF-369-02-01 10/22/12
ASTM C1289 G'AF-464-02-01 02/06/14
TAS 139 GAF-671-02-01 06/30/16
TAS 114 GAF-434-02-03 09/06/13
Momentum Technologies Inc. ASTM D6162 AX04C9A 06/05/09
A
A
z
A
3 NOA No.: 16-1206.02
MIAMI•oanE COUNTY _ Expiration Date: 02/22/22
Approval Date: 02/16/17
Page 8 of 18
I
Membrane Type: APP/SBS
Deck Type 1: Wood,Non-insulated !
Deck Description: Min. 15/32"plywood attached to supports ma4.124"o.c.with 8d common nails
max. 6"o.c. 'i
System Type E(1): Base Sheet is mechanically attached to the deck.Membrane fully or partially
adhered.
All General and System Limitations shall apply.
Fire Barrier: Topcoat'FireOuf 'Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck
(Optional) Protection,DensDeck°Roof Board or Securock'Gypsum-Fiber Roof Board.
Base Sheet: Liberty'MA Mechanically Attached Base Sheet in accordance with
manufacturer's instructions.
Fastening Options: Base sheet is mechanically attached to the deck with Drill-Tec"#14 Fasteners and
Drill-Tec"3"Steel Plates 8"o.c.in the 3"laps and 8"o.c.in two staggered rows
in the field.
(Maximum Design Pressure—60 psf.,See General Limitation#7)
Base sheet is mechanically attached to the deck with Miami Dade approved tin-
caps and nails at 8'.'o.c. in the 3"laps and 8"o.c.in three equally spaced,
staggered rows in the field of the sheet.
(Maximum Design Pressure—45 psf.,See General Limitation#7)
Ply Sheet: One or more layers of Liberty'"'SBS Self-Adhering Base/Ply Sheet in accordance
(Optional) with manufacturer's instructions.
OR 10
One layer of WeatherWatch®XT self-adhered(vith minimum 3"wide laps and
rolled with a weighted roller in accordance with manufacturer's instructions.
Note:WeatherWatch®XT may only be used with a torch adhered cap.
Membrane: One layer of Liberty SBS Self-Adhering Cap Sheet self-adhered in accordance
with manufacturer's instructions. (Not for use with WeatherWatch®XT)
Or
One or more layers of Ruberoid®SBS Heat-Weld'.25,Ruberoid®SBS Heat-
Weld"Smooth,Ruberoid®SBS Heat-Weld""Granule,Ruberoid®SBS Heat-
Weld"'' 170 FR,Ruberoid®SBS Heat-Weld'Plus,Ruberoid®SBS Heat-Weld&'
Plus FR or Ruberoid®EnergyCap'SBS Heat-Weld'Plus FR heat welded in
accordance with manufacturer's instructions.
OR
Ruberoid®Torch Smooth,Tri-Ply®TP-4,Ruberoid®Torch Granule,Tri-Ply®TP-
4G,Ruberoid®Torch FR,Ruberoid®EnergyCap"Torch Plus FR or Ruberoid®
EnergyCap"Torch Granule FR with minimum 3"wide laps and torch applied in
accordance with manufacturer's instructions.
t
I
NOA No.: 16-1206.02
► Expiration Date: 02/22/22
MIAMFDADECOUNTY
� Approval Date: 02/16/17
Page 15 of 18
A
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be listed in a current NOA Approval and applied in
accordance with manufacturer's instructions.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of
approved asphalt at 60 lbs./sq.
2. GAFGLASI Mineral Surfaced Cap Sheet,Tri-Ply®Mineral Surfaced Cap Sheet or
GAFGLAS®EnergyCapT''BUR Mineral Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. Topcoat®Membrane,Topcoat®MB Plus(to be used as a primer with Topcoat®Membrane)
or Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq.
4. Fibered Aluminum Roof Coating.
Maximum Design
Pressure: See fastening options above
A
6
NOA No.: 16-1206.02
Expiration Date: 02/22/22
MuvKwa��courmr Approval Date: 02/16/17
Page 16 of 18
I
i
Membrane Type: APP/SBS
Deck Type 1: Wood,Non-insulated
Deck Description: Min. 19/32" CDX plywood nailed to 6"o.c. at the field of the sheet with#8 ring
shank nails and 4"o.c. at the perimeter of the sheet with#10 ring shank nails.
Plywood installed over wood rafters spaced 24"o.c.
System Type E(2): Base sheet is mechanically attached to the deck.oembrane fully or partially
adhered.
All General and System Limitations shall apply. 4:
Fire Barrier: Topcoat®FireOut'''Fire Barrier Coating,Versakhield®Fire-Resistant Roof Deck
(Optional) Protection,DensDeck®Roof Board or Securock'Gypsum-Fiber Roof Board.
Base Sheet: StormSafe""Anchor Sheet is fastened to the plywood deck using Drill-Tec'#12
Fasteners and 3"Drill-Tec''Accutrac'Flat Plates or Drill-Tec 'AccuTrac®
Recessed Plates spaced 9"o.c.at the 4"side laps and 3 rows spaced 9"o.c.in the
field of the sheet.
Ply Sheet: One layer of Liberty'SBS Self-Adhering Base/Ply Sheet self-adhered with
(Optional) minimum 3"wide laps and rolled with a weighted roller in accordance with
manufacturer's instructions.
Membrane: One layer of Liberty"SBS Self-Adhering Cap Sheet self-adhered with
minimum 4"wide laps and rolled with a weighted roller in accordance with
manufacturer's instructions.
Or
One or more layers of Ruberoid®SBS Heat-Weld"25,Ruberoid®SBS Heat-Weld"
Smooth,Ruberoid®SBS Heat-Weld""Granule,Ruberoid'SBS Heat-Weld' 170
FR,Ruberoid®SBS Heat-Weld"Plus,Ruberoid®SBS Heat-Weld7Plus FR or
Ruberoid®EnergyCap' SBS Heat-Weld"Plus 11R heat welded in accordance with
manufacturer's instructions.
OR
Ruberoid®Torch Smooth,Tri-Ply®TP-4,Ruberoid®Torch Granule,Tri-Ply®TP-
4G,Ruberoid®Torch FR,Ruberoid®EnergyCa�'°'Torch Plus FR or Ruberoid®
EnergyCap'Torch Granule FR with minimum 3"wide laps and torch applied in
accordance with manufacturer's instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be listed in a current NOA Approval and applied in
accordance with manufacturer's instructions.
1. Gravel or-slag applied at 400 lbs./sq. and 3001bs./sq.respectively in a flood coat of
approved asphalt at 60 lbs./sq.
2. GAFGLAS®Mineral Surfaced Cap Sheet,Tri-Ply'Mineral Surfaced Cap Sheet or
GAFGLAS®EnergyCap''BUR Mineral Surfaced Cap Sheet adhered in a full mopping of
approved'asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. Topcoat®Membrane,Topcoat'MB Plus(to be used as a primer with Topcoat®Membrane)
or Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq.
4. Fibered Aluminum Roof Coating.
Maximum Design ,
-Pressure: -60 psf. (See General Limitation#7)
i NOA No.: 16-1206.02
Expiration Date: 02/22/22
efoao�EDjL rr Approval Date: 02/16/17
Page 17 of 18
r
_ I
Ti
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with GAFGLAS®Ply 4,Tri-Ply®Ply 4 and GAFGLAS®F1exPly 6 when used as
a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
e
1. Fire classification is not part of this acceptance;refer to a current*pproved Roofing Materials Directory
for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall-be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.,or mechanically attached using the
fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,
panel size shall be 4'x 4'maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam
insulations when the base sheet is fully mopped.If no recovery board is used the base sheet shall be
applied using spot mopping with approved asphalt, 12" diameter ciieles,24" o.c.;or strip mopped 8"
ribbons in three rows,one at each side lap and one down the centeiqof the sheet allowing a continuous.
area of ventilation. Encircling of the strips is not acceptable. A 6"break shall be placed every 12'in
each ribbon to allow cross ventilation. Asphalt application of eithe-system shall be at a minimum rate of
12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf.
5. Fastener spacing for insulation attachment is,based on a Minimum Characteristic Force(F')value of 275
lbf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-
tested,are below 275 lbf.insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchorlbase sheet or membrane attachment is based on a
minimum fastener resistance value in conjunction with the maximum design value listed within a specific
system. Should the fastener resistance be less than that required,I determined by the Building Official,
a revised fastener spacing,prepared,signed and sealed by a Florida Registered Engineer,Architect,or
Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal
resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with
Roofing Application Standard RAS 117.
7. Perimeter and corner areas,shall comply with the enhanced uplift pressure requirements of these areas.
Fastener densities shall be.increased for both insulation and base sheet as calculated in compliance with
Roofing Application Standard RAS 117.Calculations prepared,signed and sealed by a Florida registered
Professional Engineer,Registered Architect,or Registered Roof Consultant(When this limitation is .
specifically referred within this NOA,General Limitation#9 will not be applicable.)
8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall
conform with Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e.fiel(L.
perimeters,and corners).Neither rational analysis,nor extrapolatiop shall be permitted for enhanced
fastening at enhanced pressure zones(i.e.perimeters,extended corners and comers). (When this
limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 16-1206.02
Expiration Date: 02/22/22
MaMwaue courmr a Approval Date: 02/16/17