HomeMy WebLinkAboutWind Load Calculation � EXTE � ' DIS `�Bta l Ph Qur Qualrty¢R'"', too ustorner At Time" SCC131150.472�; Property Information Building Information Owner: RANDALL&JENNIFER RAGLAND Wind Zone: 170 MPH. Address: 5771 DEER RUN DR 3J Exposure Category: C FORT PIERCE,FL 34951 Minimum Building Dimension: 53 ft. Mean Roof Height: 20 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 59 48 7 38.4 41.8 2 Int 47 48 7 39.0 42.4 3 Int 47 48 7 39.0 42.4 4 Int 58 48 7 38.4 41.8 5 Int 35 36 7 40.2 -43.6 i RECEIVE® FEB 14 202.0 ST. Lucie County, Permitting 0 Uj Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.61h Edition(2017)Florida Building Code. Page I of 1