HomeMy WebLinkAboutSavannah's Preserve State Park appAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date. 2118120 Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential x
PERMIT TYPE: SERVICE CHANGE - ELECTRICAL
PROPOSED IMPROVEMENT LOCATION:
Address: 10979 WETLAND WAY
Property Tax Id #: 450 9-802-0 004-000-4 Lot No.
Site Plan Name: SAVANNAH'S PRESERVE r)[--I. K1_
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: � Not Applicable
Name:
MORTGAGE COMPANY: _ Not Applicable
Name:
Address:
City: State:
Zip: Phone
Address:
City: State:
Zip: Phone:
FEE SIMPLE TITLE HOLDER: Not Applicable
BONDING COMPANY: Not Applicable
Name.,
Name:
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated,
1 certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in a€I respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT."
2/14/2020
Customer (1530x2O4O)
_ A C? n c
i
MOTTO SCALE
J r C Urvderground FPL Required — ES or NO (circle one)
Overhead FPLAccount Number
Meter [Number and Picture Pc-,z3 1`4`- �
5
]fill?
ItI AIR ,
Lx. n EC13006M6 #CAC1816433
f 1. Size Service I
2. Conductor Size
j > 3, a. Meter Main r�
b. Meter Can Only:
(M� >r f
TOUNDING ELECTRODE CONDUCTOR SIZE-
❑ #6
®� #4
❑ #2
❑ Other
CONSTTION TYPE;
�' Residential
Q Mobile Home
New Installation T
❑ Old Installati
NOTES:
https:/lgo.servicetitan-com/Attach/Customer?name=Attaches%2F77f85c93-8706-4cce-a94d-47dgcl8d002d_cdv_photo_001-19ypmlcn4hm.jpg
2/14/2020 Customer (1530x204O)
Electrical Load Calculations
at
€.xisting Sc ice Feeder Size: _._ Existing Papal Size:
1 p 1 - 4• -..y t�
P _.r, fV-- `C'..l`t..�t ? 1SdTr� 1 ............... ............. :Src 7 1W3ti5
v ..F p!iance t;ir. .500 watts each ...... 305 o watts
__—t,aundrt Or, @'1500 watts each .... ................. o }vans
a7�e
r
--Dishwasher and disposal @ 1500 watts each...... '3 0 o O yam
icrowave @ 240o watts- . .......................... Z. o 63 wat s
�.. Watersseater @ 4.5 ku................................. _ �� O watts
_Tanklesswater heater..... ........ ............ -.. ...--- watts
�rYer@5kw......... ......................... ......... s ways
1 : —Refrigerator@ 1500 \art .... /s watts
Bathroom 1 rL; 1500 watts ........... 1 s watts
Sprinkler Pump ........................................ watts
Other
_Other ........... w-atts
At er u acts Sub total = 34 watts
pump...............................................� _watts
Poollight ................................................. watts
Heatpump..... . .......... ......... ............... watts
Chlorinc generator.................................e.... t4ait5
Airblower ..................................... watts
., . Boatlift.............................................
watts
........... watt
-Other
Total Watts
i"iYSf 10 kNA; l 100%l .......... r C� 4� � lY2tt5
t - x Remainder ( �l�i"f�................ - watts
P r
�.A/C i.s'a# 0E3a/k...,......................................_warts
#di Y�ti€ts i Divided by 240 volts = 1 r17- a AMV
-
,Prepared by.,
https:lIgo.servicetitan.camlAttachlCustomer?name=Attaches%2F7293a004-10b8-4050-91a9-412947a9d3cd_cdv_photo_G01-alil36cnezt.jpg 111
2/14/2020
Customer (153N2040)
https:llgo.servicetitan.com/Attach/Customer?name=Attaches%2F8ce7b823-bOf3-4634-a8b3-2a29b5bl2b95_cdv_photo_001-9fuy64g9f04.jpg 1I1
2/14/2020
Customer (1530X2040)
wrr -7 %
https://go.servicetitan.r-om/Attach/Customer?name=Attaches%2F627829aa-7063-4128-ace2-1683b6Of359f cdv photo, 001-wg1p3wuszd.jpg 111
Michelle Franklin, CFA -- Saint Lucie County Property Appraiser --All rights reserved.
Property Identification
Site Address: 10979 Parcel ID: 4509-802-0004- Account 4: 122942 See/Town/Range: 09/37S/41E
WETLAND WAY 000-4 Map ID: 45/09S Zoning: AR 1 Count
Use Type: 8200 Jurisdiction: Saint Lucie
County
Ownership Legal Description
Tr Int Imp Trust Fund LETOURNEAU'S S/D LOT 4-LESS RD R/W- (OR 1362-1788)
3900 Commonwealth. Blvd
Tallahassee, FL 32399
Current Values Historical Values 3-year
Just/Market: $187,700 Assessed: $187,700 Year
Just/Market
Assessed
Exemptions
Taxable
Exemptions: $187,700 Taxable: $0 2019
$187,700
$197,700
$187,700
$0
2018
$176,900
$172,098
$172,098
$0
2017
$173,300
$156,453
$156,453
$0
Date
02-02-2001
12-01-1986
11-01-1971
View:
Year Built: 1987
Primary Wall: Cypress BB
Bedrooms: 0
Full Baths: 2
Half Baths: 0
Sale History
Book/Page
Sale Code Deed Grantor
1362 / 1788
XX01 WD Boll William
0542 / 0565
XX00 CV
0352 / 3526
XX00 CV
Primary Building Information
Finished Area of this building: 1,542 SF
Gross Sketched Area: 2,405 SF
Roof Cover: Metal
Frame:
Story Height: 2 Story
A/C %: 100%
Heated %: 100%
Sprinkled %: 0%
Exterior Data
Roof Structure: Gable
Grade: C
No. Units: 1
Interior Data
Electric: MAXIMUM
Heat Type: FrcdHotAir
Heat Fuel: ELEC
Total Areas
Price
$220,000
$0
$3,300
Building Type: HC
Effective Year: 1987
Secondary Wall:
Primary lnt Wall:
Avg Hgt/Floor. 0
Primary Floors: Sing Pine
Finished[U.nderAir
1,878
(SF):
Gross Sketched Area
2,921
(SF):
Land Size (acres):
3.2
Land Size (SF):
139,392
Total Building Count:
2
Special Features and Yard Items
Type Qty Units Year Blt
UTILITY GOOD 1 160 1999
All information is believed to be correct at this time, but is subject to change and is provided without any warranty.
Copyright 2020 Saint Lucie County Property Appraiser. All rights reserved.