Loading...
HomeMy WebLinkAboutbuilding permitALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED 77771 02/20/2020 Permit Number: Date: JI NIRTgV Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Residential X Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial PERMIT APPLICATION FOR: Mechanical P2bPOS�D lJV1,2.10U1VIEN�OG/�TrO�V'y Address: 108 Ohio st Legal Description: Lot No._ Tax ID If: 45a2 �,04 0056 000 ^ Property Block No. Site Plan Name: _ audra Curtis Project Name; — Setbacks Front Back: Right Side: _ Left Side:Uf y � DE�F�17L`�DUESGf�7PTION�OF WiQRKr� �� ' _ LIKE FOR LIKE A/C CHANGEOLIT and duct work 2.5 ton duct work infomation attched 10 kw 16 seer eQtus�ucTI�N�NFoMATI�N Yiona wor<to e erforme un ert is permit—ctec<a � apply � �✓ � Gas Tank Piping Shutters � Windows/Doors HVAC �❑jGas ❑Sprinlders �GeneraYor Roof Roof pitch Electric OPlumbing loor: Total Sq. Ft of Construction: S Ft, of First F��jj 9274.00 Utilities" Sewer IJSeptic Building Height: Cost of Construction: $ gq OWNRILESSI E r C(?NTRACT9%1s R_ .-.,..' ,,_F r _ CHRIS LANGEL Name: Name ^"_._!i PliaS SEACOASTA/C Address: 2901 se lander ave Company: fl 3108INDUSTRIAL 31st STREET city; State: Address: _psi 34952 Cjty; FT PIERCE State: F� Zip Code: Fax: 34946 Fax: 772-448-4416 Phone No, 863-412-1604 Zip Code: Phone No, 772-466-2400 GMail: INFO@SEACOASTAIR.COM Fill in fee simple Title Holder on next page (if different E-Mall; CMC036421 from the Owner listed above) State or County License: Is $2500 ar more, a RECORDED Notice of Commencement is required. If value of construction Name: Address:__ City: Zip: Phone: FEE SIMPLE TITLE HOLDER: Name: Address: City: _ Zip: _ _Not Applicable MORTGAGE COMPANY: Name: Address: City: Phone: BONDING COMPANY; Name: Address: Not Applicable _Not Applicable I certify that no work or Installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure structure Please consult ww with yolur Home Owners Association Association drreview your deed for any restrictions may htrmay applyh bit such In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first+nspection. tf yoy-'ntend to obtain financing, consult with lender or an attorney gfore commencing work or reco/41 our Notice of Commencement % /-- as STATE OF FLORIDA COUNTY 0 F sr wcle The forggoing instrument was acknowledgeed� y��efore me this .. ay Gffebruary zo by CNRIS IANGEL �- (Name ofperson acknowledging I STATE OF FLORIDA COUNTY OFsTwas The forgoing instrument was acknowledged before me this 20dayof februar�zo�by GHRIa LANGEL _ (Name of person acknowledging ) ignature of No ary Public -State of Florida j (S ature of Notar}Public- State of Elorida) 1 Personally Known x _ OR Produced Identification _ Personally Known x OR Produced Identification Type of Identification Produced Type of identification Produced ccsaas "'Yb,'°•., JUSTI OPKINS CGNNELLY Commission No, ccs40 Commission No.M 4"— JUSTINA , 0 INSCGNNELLY ;; MYCGMMISSIGNkGG940082 ar, YCOMMISSION90l MYCOMMISSIGN6G0960602 c'`---EXPIRES: S[�cem" Sr ,2023 •.P,f;fF"•'� BoMed Tblu Notary Public USdmWairs ' o; C„� Bonded Thai Notary Publb UndonMlere Revised 07/15/2014 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE REVIEW MANGROVE REVIEW COUNTER REVIEW REVIEW REVIEW REVIEW DATE COMPLETE _ INITIALS This combination qualifies for a Federal Energy Efficiency tax Credit when placed in service between Feb 17,2009 and Dec 31, 2016. AHRI Certified Reference Number: 10259437 Date: 02-20-2020 Model Status : Acfiv4 AHRI Type : RCU-A-CB Series : MERIT ML14XCl SERIES Outdoor Unit Brand Name: LENNOX Outdoor Unit Model Number (Condenser or Single Package) : ML14XC1S030-230A** Indoor Unit Model Number (Evaporator and/or Air Handler) : CBA27UHE-030-230*+TDR RSoutheast and North (ALARDCDEFL, GA, HI, KY, LA, MD, MS, egion : , , , , Al IN, KS, MA, ME, MI, MN, MO, MT, ND, NE, NH, NJ, NY, OH, OR, PA, RI, SO, UT, VT, WA, WV, WI, WY, U.S. Territories) Region Note : Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in ail regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. t Aketed bu tare nott yet beingsproduced AProduct In Stopp d�ModePStalusaarelthose that an AHRI CertifDicatieln ProgramrlParticipalnl l no longer producing BUT lis still m ling or offering fosale. R t n that r maried by WAS indicate n involuntaa re -rate. Thew p bi' h d t' a shown along w'th the previous (i.e. WAS1 rating. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and rmances no responsibility for, the producl(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the protluct(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www,ahrldirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, he reproduced; copied; disseminated; ' entered into a computer database; or otherwise utilized, In any form or manner or by any means, except for the user's individual, AIR-CONDITIONING, HEATING, personal and confidential reference. & REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION Tile Information for the model cited on this certificate can be verified at www.ahrldirectory.org, click oil "Verify Certificate" link we make life bettee• and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. 132266823840389860 92020Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: Job: vuri Fttsoft Project Summary gate: 9 Entire House Y: QUICK CALCS, INC. ... For: 108 OHI SIRE 108 OHIO STREET, FT PIERCE, FL Notes: Weather: Winter Design Conditions Outside db Inside db Design TO Fort Pierce, FL, US Summer Design Conditions 42 °F Outsidedb 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 17133 Btuh Ducts 3880 Btuh Central vent (0 cfm) 0 Btuh (none) 0 Btuh Humidification 0 Btuh Piping 21013 Btuh Equipment load Infiltration Method Constmction quality Fireplaces Simplified Average 0 He 1t289 Co 1289 Area Volume 10312 10312 AirchairhangesRlour 0.45 0.23 Equiv. AUF(cfm) 77 40 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 7.8 kW 26550 Btuh 50 OF 483 cfm 0.023 cffnBtuh 0.50 in H2O 90 90 °F 75 °F 15 °F M 50 61 gr4b Sensible Cooling Equipment Load Sizing St udure 16771 Btuh Ducts 4827 Btuh Central vent (0 cfm) 0 Btuh (none) 0 Btuh Blower Use manufacturers data n Rate/swingg multiplier 0.95 Equipmentsensible load 20518 Btuh Latent Cooling Equipment Load Sizing St ucture 1651 Btuh Duds 1502 Btuh Central vent (0 cfin) 0 Btuh (none) 3153 Btuh Equi pment latent load Equipment Total Load (Sen+Lat) 23671 Btuh Req. total capacity at 0.70 SHR 2.4 ton Cooling Equipment Summary Make Lennox Trade Cond ML14XClSO30-230A Coil CBA27UHE-030-230 AHRI ref Efficiency 13.0 EER,16 SEER Sensible cooling 20300 Btuh L itent cooling 8700 Btuh Total cooling 29000 Btuh Actual airflow 967 cfm Arflow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.87 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2020-Feb-20 07:33:06 _ wrightsof[a RIgfe Stite® Uwersa1201919.0.07 RSU08107 Page s ACCA ..ICKt➢or etts\Wdgt0. ftfNAC\CURTIS,AUFRA,n Caic-MJ8 Frost Ooorfaws:SE Name Trunk Type Hig (Cfm) Clg (cfm) Design FR Veloc (ipm) Diam (in) H x W (in) Duct Material Trunk rt1 PeakAVF 483 967 0.122 693 16.0 0 x 0 VInIFIX Bol�falk values have Geen manually ovemtlrten -h"�d- wrightsoft" zozo-Fab-zo o7:aa:os t9.0.07 RS000107 Paget �iC� ..ICICrpocurrerds\Wrighlsoil HUAQCURTIS, AUfRA.rip CaIc=MJO Fram Door faces:SE Performed for: AU�RACURTIS 108OHDSTREET FT. PIERCE, FL QUICK CALCS, INC. 317 ST LUCIE LANE FORT PIE PY'E, FL 34946 Phone: 772-466-6799 QUICKCALCS@AOL.COM Scale: 1 : 95 Page 1 RlghtSuHer'� Universal2o19 19.0.07 RSUOS101 2020-Feb-2007:32:56 ...dghtsoft HUADCURTIS,AUFRA.rup