Loading...
HomeMy WebLinkAboutProduct approvals Florida Building Code Online Page 1 of I4 U19fFLCRI l Busin • •Manion!, @ P BCIS Home j Log In i user Registration I Hot Topics I Submit Surcharge I Stats&Facts Publications I Contact Us I BCIS Site Map, Links i Search.I product Approval FL15210.1 6 8 HVHZ OPAGUE FIBERGLASS dbo� � r USER:Public User SINGLE DOOR IN—OS � proAuct Aooroval Menu>Product or Aoolication Search>Application List>Application Detail � 1 INI iIIFKYI�. . •t��• J'' FL# FL15210-R6 ' Application Type Revision Code Version 2017 Application Status Approved i Comments Archived ❑ Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES,CA 90045 (440)969-9773 Ext 16 i rickw@rwbidgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com I Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd, Los Angeles,CA 90045 (440)969-9773 Ext 16 ronoconnell@plastpro.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies I Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received i Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J.King,P.E. © Validation Checklist-Hardcopy Received Certificate of Independence FL15210 R6 COI fat Certificate of Indeoendence.odf I Referenced Standard and Year(of Standard) Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 1998 ASTM D638 2003 ASTM E1300 2004 ASTM E84 2005 ASTM G26 1995 G 155 2005 TAS 201,202,203 1994 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ 1... 12/31/2019 Florida Building Code Online Page 2 of 4 I i Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15210 R6 Eauiv (a)Equivalency of Standards.odf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/13/2017 Date Validated 09/18/2017 Date Pending FBC Approval 09/20/2017 Date Approved 12/12/2017 I F15210.1 mary of Products # Model,Number or Name Description a.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door- Grain/Rustic/Mahogany Series O Inswing/Outswing(X-Configuration) Fiberglass Door its of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.1.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.1 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.1.ndf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.2 b.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series 0 Sidelites-Inswing/Outswing(OX or XO;OXO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.2.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.2 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.2.odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15210.3 c.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Double Door with or without Grain/Rustic/Mahogany Series 0 Sidelites-Inswing/Outswing(XX;OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL15210 R6 II (b)Inst 15210.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.3 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.3.0f additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15210.4 P.Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Single Door- Grain/Rustic/Mahogany Series O Inswing/Outswing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II IN Inst 15210.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.4 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.4.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. i 15210.5 e.Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing(OX or X0;OXO- Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.5.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports https://www.floridabuilding.org/pr/pi_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZ 1... 12/31/2019 I Florida Building Code Online Page 3 of 14 Other:See INST 15210.5 for Design Pressure Ratings,any I FLIS210 R6 AE (b)Eva(15210.5.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.6 f.Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing(XX;OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.6 for Design Pressure Ratings,any FL15210 R6 AE (bl Eval 15210.6.odf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15210.7 g.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door-Outswing(X- Grain/Rustic/Mahogany Series O Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL15210 R6 II (b)Inst 15210.7.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.7 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.7.0f additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.8 h.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series 0 Sidelites-Outswing(OX or XO; OXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (bl Inst 15210.8.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.8 for Design Pressure Ratings,any FL15210 R6 AE (b)Eva[15210.8.odf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. I 15210.9 i.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series O Sidelites-Outswing(XX;OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FLIS210 R6 II (b)Inst 15210.9.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.9 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.9.13df additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.10 rGrain/R',ustic/Mahogany oth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door-Outswing(X- Series O Configuration) glss Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.10.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.10 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.10.odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 15210.11 k.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites-Outswing(OX or XO;OXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.11.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.11 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.11.1)df additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15210.12 I.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Double Door with or without Grain/Rustic/Mahogany Series 0 Sidelites-Outswing(XX;OXXO-Configurations) Fiberglass Door https://www.floridabuilding.org/pr/pi_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZ 1... 12/31/2019 Florida Building Code Online Page 4 of • I Limits of UseInstallation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (bl Inst 15210.12.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.12 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.12.Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.13 m.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Surface Grain/Rustic/Mahogany Series O Bolts-Outswing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.13.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.13 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.13.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.14 n.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Double Door with Surface Grain/Rustic/Mahogany Series O Bolts on Active Door panel-Outswing(XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.14.0f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.14 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.14.Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.15 o.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door utilizing the Grain/Rustic/Mahogany Series 0 WINDSERT11 an operational window insert-Outswing(X- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R6 II (b)Inst 15210.15.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.15 for Design Pressure Ratings,any FL15210 R6 AE (b)Eval 15210.15.1)df additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. I Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ®9 eChxF M Credit Card Safe i I I I https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=w wtDgv3yVVKJZI... 12/31/2019 R W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product / Report Date: A ttgusf 10,2017 Product Sub Category Manufacturer Product Name Category Plastpro,Inc. Smooth/Wood Grain I White Wood Grain Exterior Swinging Exterior Door 5200 W.Century Blvd. Rustic I Mahogany ,. Doors Assemblies Los Angeles,CA 90045 Series O Fiberglass Door Phone 440.969.9773 InswinglOutswing-'Impact' Scope: Product Evaluation report issued by R W Building Consultants, Inc.&Lyndon F. Schmidt, P.E. (System ID#1998)for Plastpro Inc.,based on Rule Chapter No.611320-3, Method 1 D of the State of Florida Product Approval,Department',of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt, P.E.do not have nor will acquire financial interest in the company j manufacturing or distributing the product or in any other entity involved in the approval process of the product named, herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code,(FBC)structural requirements including the"High Velocity Hurricane Zone". 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the"HVHZ this product complies with Section 1626 of the Florida Building Code and does not require an impact II resistant covering. 4. When used in areas outside of the"HVHZ"requiring wind borne debris protection this product complies with FBC Sections 1609.1.2& R301.2.1.2 and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2&R301.2,1.2.1. 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of drawing FL-15210.1 require further engineering analysis by a licensed engineer or registered architect. 7. Outswing configurations meet water infiltration requirements for"HVHZ'. All other configurations do not meet the water infiltration requirements for the"HVHZ'and must be installed only in non-habitable areas or at habitable.locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. 8. See drawing FL-15210.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01390365 TAS 201-94,202-94&TAS 203-94 Testing Evaluation Lab.,Inc. Lyndon F.Schmidt,P.E. TEL 01391846 TAS 201-94,202-94&TAS 203-94 Testing Evaluation Lab„Inc. William Shelton,P.E. ETC-05-255-16776.0 ASTM D 635-98,638-03,1929-96&2843-99 ETC Laboratories Joseph L.Doldan,P.E. ASTM G 26-95 ETC-06-255-17412.0 ASTM E 84-05 ETC Laboratories Joseph L.Doldan,P.E. ETC-07-209-19303.0 ASTM D 635-98,638-03,1929-96&2843-99 ETC Laboratories Ben Meunier 2. Drawing No. Prepared by Signed&Sealed by No.FL-15210.1 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 3. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. Quality Assurance ,`e`1%1/0 1 1 11110 ' Certificate of Participation issued by National Accreditation and Management �e $cHRry� I� Institute,certifying that Plastpro,Inc.is manufacturing products within a quality ������:••' �,' ���� assurance program that complies with ISO/IEC 17020 and Guide 53. ��� • \C' S4 � % No 43409 :.-0: X90: STATE OF :ALU AN �� OP����� Lyndon F.Schmidt;P.E. oii�S •O ���� FLPE No.43409 Sheet 1 of 1 ��iooS�ON AX,��0b® 8/31/2017 plastpro ♦ r N 5200 W. CENTURY BLVD. Z � ow LOS ANGELES, CA 90045 Smooth / Wood Grain / White Wood Grain 37.50"MAX.OVERALL 'j pt,`'♦ o n Z Rustic/Mahogany FRAME e E� =m z Series O Fiberglass Door a Lot? cioll m o a INSWING/OUTSWING E 0Z ® ® o V 'IMPACT" 0 c4 o GENERAL NOTES O z cry o 1. This product has been evaluated and Is in compliance with the 6th Edition(2017)Florida Building 3 o o--+ g Code (FBC)structural requirements including the"High Velocity Hurricane Zone"(HVHZ). z O z o o a 2 Product anchors shall be as luted and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. _ = m lU Ut a a uQ U Ne is 3. When used in the"HVHZ"this product complies with Section 1626 of the Florida Bulding Code and v C r does not require an impact resistant covering. 11 • Q a $ 4. When used in areas outside of the W I-IT'requiring wind bome debris protection,this product u compiles with FBC Sections 1609.12&R301.2.12 and does not requ"re an impact resistant covering. p O m E This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E 1996 cnd FBC Sections 1609.1.22&R301.2.11 1. ib 5. For 2-stud construction,anchoring of these units shall be the some as that shown for 2x buck masonry ^ construction. N N ;~ w 6. Site conditions that deviate from the details of this require further engineering analysis wc t by a � � licensed engineer or registered architect. Q� r 7. Outswing configurations meet water infiltration requirements For"HVHZ".All other configurations do � not meet the water Infiltration requirements for the"HVHT'and must be installed only in non-hobitabie E areas or at habitable locations protected by an overhang or canopy such that the angle between a a ; z the edge of canopy or overhang to sill is less than 45 degrees. TABLE OF CONTENTS SHEET# DESCRIPTION SHEET# DESCRIPTION n m - - 1 Typical Elevations,Design Pressures—&General Notes 7 Hor¢onlal&Vertical Cross Sections(Direct to Masonry) MAX a 0 0 DESIGN PRESSl1RE{PSF) Z a 2 Door Panel Decals 8 3-point tock—details CONFIGURATION FRAME 3 Horizontal&Vertical Cross Sections(2X Buck) 9 3-point lock details DjTt9ENS/41+1: POSlT1Y NEGATtYE= °1e 02�t 6 t2 0 4 Horizontal&Vertical Cross Sections(1 X Buck) 10 Buck and frame anchoring sr N.T.S. _ 5 Horizontal&Vertical Cross Sections(D nett to Masonry) 1 I Components X 37.5"x 82.0" +75,p _75(} D"G er: JK M 6 Vertical Cross Sections(Thresholds) 12 Bill of materials arc,er: LFS 3 s" See sheets 2 for hardware design pressure limitations n FL-15210.1 N ci 3�EET y Or 1z w 2.8" ............ Oma' m EXTERIOR m m 0.4' 0.4. o J-o rni Z 4..`O`Ed o a HE .• z o,> ;° //I/r r l Pit ttt m d o n z u N•: !� v o oia INTERIOR TOP RAIL vi o o m c w CAP(PVC11 ) °) LATCH STILE(LVL) Q� o °a o o o_ HINGE STILE(LVL) CAP(PVC) (COMP.) a` (Ain 5 r a mao 9 4 . 1 HORIZONTAL CROSS SECTION __TE .;i- 2 0 N: i cn 35.75'MAX O.A. o a WIDTH L •o' ?0 0 ovj � w wo w o O ¢ d v 2 v O HARDWARE TABLE — "' °° MAK DES GN INTERIOR EXTERIOR y o MANUFACTURER MODELPRESSURE IS m ... ..-:....... E (", KNOB' SIGNATURE SERIES m m = KWIKSET 'DEADBOLi: SIGNATURE SERIES(9B0) ±75 FOAM CORE �` " q (POLYURETHANE- _ _* Q' O KNOB: -r SERIES(F51) 0 0 ( ) 1.9 PCF MIN.) N N gSCHLAGE }75 a'• m � � DEADBOLT: "'SERIES(B60/62) '. En X Z SEE HARDWARE TABLE LEVER: FL3B SERIES w w o n PAMEX DFADBOLT: FD7 SERIES ±75 °• :•a.• h ZIj opo HOPPE MULTIPOINTLOCK: HLS90003-POINT TONGUE ±50 FIBERGLASS SKIN ° ,•• k' SEE HARDWARE TABLE (0.125'MIN.THK) j j z ENDURA MULTIPOINT LOCK: TRILENNIUM 3000(3-PT) }75 s" See sheets 5 and 6 for multipoint lock details. N o BOTTOM RAIL z .1 (COMP.) j ,: � ° DAM 02116112 ° z f 2 scuE ° N.T.S. w DOOR PANEL mvc.m_ JK m 4U PbfO 2 VERTICAL CROSS SECTION cwc er: LFS 3 2 Fiberglass 2 OWING NO: FL ° S_ lV —15210.1 0 SHM_jL OF 12 a R:\Cllents\Plastprd,Inc PERMANENT\A-Florida Product Approvals\FL-15210 HVH2 Fiberglass-impact Opaque and Glazed\C-Dmwings\FL-15210(2017)\FL-15210.1-6.dwg,3.1 i F. A �z s Q 20 e N � O r � r r pppp A _.O V W V 3 rn v Z o d a+N v ® ® ® A w A W N � O Z O"W O Ut 40 M M QT 0 Q VA V N USN dN W N cp:O 0 w v N 3. V v Z 'oO r �� O� N V(0- --T .— T 0 O IA z v ° I ° • P ° �A � Z � T . I W W M O yQPC �n Y N D ° � o .Z7 0.15'C-SINK \ \`t\SCH 11 )TYP) ��vFV ,Or'i�� 1.1/4 MIN EMB.PP.) L-}„ No.43409 Q PRODUCT: Document.Prepared r o P(ASTPRO INC. LYE No. 43409Schmidt Iw o Z\ FIBERGLASS DOOR 'q��10NAL r— 2 UPDATE TO 6TH ED, N 1 3 9 15 UPDATE TO 5TH ED. 2014 PBC JK PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. IO P.O. Box 230, VDIrICo. FL 33595 N N NO DATE OSSZSTN2n REVISIONS CROSS (2X BUCK) Phone No.: 813.859.9197 F'BPE C.A. No, 9813 0 201&R.W.BUILDING C...e LT-1.INC. , I RACIents\Plastpm,Inc PERMANENT\A-Florida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and Glazed\C-Drawings\FL-15210(2017)\FL-15210.1-6.dwg,4.1 I i T e ° A > rn O:r o O m a, f'1 rof O V? ox� , cn O >r. Co to V o Q g N Z � I I0 O 0 A N 0- C=r O N O7C� n �n Q .°c N T a c ° T T p a N 0 o rr< _a I Oxy I cr a .� N o-- ° � _ o Z P pu P I vv N I n I \\\\1111111////// SCNIy ., 1-1/4 MIN. �`` F' � EMB.(TYP.) / �` V,--vc ... -i L No.43409 QI PRODUCT; Documents Prepared By: PLASTPRO INC. Lyndon F. Schmidt �ii�s••� 0 •'(1j����` IA I •• N FIBERGLASS DOOR P-E. No. 43408 ���/s�Of1)AL o N 'D' Z //llllllll\\ ti 2 7 24 17 UPDATE TO 6TH ED. 2017 FBC JJK PART OR ASSEMBLY: �mVKQ BUILDING CONSULTANTS, INC. p x 1 3 9 15 UPDATE TO 5TH ED. 2014 FBC rl 1, P.O. Box 230, Valrico, FL 33595 NO DATE CROSSZONTAL S C77ONS VERTICAL Phone No.: 813.859.9197 REVISIONS FSPE C.A. No. 9813 02D16 R.W.BUILDING C-ULTq NT9 INC• i R:\Olents\Plastpm,Inc PERMANENT\A-Florida Product ApprwalS%FL-15210 HVHZ Fiberglass-Impact Opaoue and Gla:ed\C-Drawings\FL-15210(2017)\FL-15210.1-6.dwg,5.1 3 v ' rn a° ^ O�x 3.� N O F— on 2Z n 3:n y V 3 rn 0 0 Ao N 2 I0 0 0 <7f N g O�x o�O O 14- rnv N �3l1 �a V .0 o _z 3 0 3 y 3 m . o � • v 0 ° v ° a M v I I I rn n 70 A ,fr W O O i M o. Oo T ° n- v �E ' O N D M A N EMB4„MIP` `����{{,gCH f f77��i (TY. T 1 `�� 1• No.49409 a 4 PRODUCT: Doaumente arep—d By:11,V, F� I� PLASTPRO INC. Lyndon F. Schmld! �iS'•.! OR10r•.�•G\`��`� I� I i ro FIBERGLASS DOOR P.E. No. 43409 .1", !OMA1. C, o c Z ... 7fff111111{{\\ ro r- y 2 7 24 17 UPDATE TO 6THED. 2017 FBC JK PART OR ASSEMBLY: (� BUILDING CONSULTANTS• INC. Iwo X in 1 J 9 15 UPDATE TO 5TH ED. 2014 FBCJK HORIZONTA & VERTICAL CROSS P,o. Box 230, vclrtco, FL 33565 tv NO DATE BY SECTIONS DIRECT TO MASONRY Phone No.: Bt3.659.9197 REVISIONS FBPE C.A. No. 9813 Qa 2016 A.W.BIIILDINCI CCNeu��4Nre INC. R:\Olents\Plastpm,Inc PERMANENT\A-Florida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and Glazed\C-Drawings\FL-15210(2017)\FL-15210.1-6.dwg,6.1 i rn M X1 0T ° s s, � O y ° 0 ryf7 •° W Z . c m .W.. A 0 0 W p e o N m ' co 0 O•N e ° A ' >� e O T ° CL I Z A_ j N 0 O PC ° M I I 1-1bf MIN. EMB.(TYP.) ep I a W ° M 0 ° A C n �y ° y e� p. c ° Z M z coo .Wi a f _ No.43409 s Q PRODUCT: Documents Prepared By:PLASTPRO INC. L-- � rn r `sN FIBERGLASS DOOR PYEa No. 43409 Schmidt ut� ? -. 1j111111111\ S4 N_ ti 2 7 24 17 UPDATE 70 6TH ED. 2017 FT3C JK PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. p t� 1 J 9 15 UPDATE TO 5TH ED. 2014 FT1C JK IP.O. Box 230, Valriao, FL 33595 N N NO DATE gy VERTICAL CROSS phone No.: 813.659.9197 REVISIONS SECTIONS (THRESHOLDS) FBPE C.A. No. 9813 FD 201 6 R.W.BuilolNa Cowsu�rn,r.Ts INc. R:\Olents\Plastpm,Inc PERMANENT\A-Florida Product Approvals\FL-15210 HVHZ Flberglass-Impact Opaque and Gla:ed\C-Drawings\FL-15210(2017)\FL-15210.1-6.dwg,7.1 ° Z. 1.5" V 3 D MAX. y�0-0 MIN, 3.7 N D 0IF— � Z �~n O T 3 m V N A n Cr p p O OS mn Z g V, 1-1/4"MIN. o n EMB.(TYP.( 0 O A V N -0! _ A goy � '• 0-= P T S Q �jCyO No O y CI� N Q Z Z y :3 rn _ �o Q Jo O A A n Q C') Si. MIN. co a Zz 2.25 4 - l.S'MAX. i V W N. MAX. 0o o MIN. D � a n Q o7 H m A A a n 3. Cn 3 A o tr `Z V P 1-1/4"MIN. c D EMB.(TYP.) OCD ^ RI v o I� A v i V A O�2 .:E A �, 06n 4 . £0 ^ ° I n �o O LS' MIN. \\\plllllllp�/ 3n z 4.25' c -1.5'MAX. ``` fi07 r' xPRODUCT: Documents Prepenld Sr. W. T Lyndon F. Schmidt iii SON•''• �`� r PLA57PR0 INC. Iv I z N FIBERGLASS DOOR P.E. No. 43409 to o Z� lllllllllll\\\ ry r ~ 2 7 24 17 UPDATE TO 6TH ED. 2017 FBC JK PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. o �1 !A 1 3 9 15 UPDATE TO 5TH ED. 2014 FBC JK ro N7�/ Iv HORIZONTAL & VERTICAL 4V P.O. Box 230, Valrico, FL 33595 O DATE BY SECTIONS (DIRECT TO MASONRY) Phone No.: 813.659.9197 REVISIONS FBPE C.A. No. 9813 201 2 R.W.BUIL..Na CaNn.1LTn N>•e INC. R.,\(;,,ent5\pIast,,d,Int pERMANENT\A-Florida product APIPTuvaltK-15210 HVHZ Fiberglass-1,ep.,t opaque and Glazed\C-0,8wji,g%\FL-15210(2017)\FL-15210-1-6.d4,8.1 > Z > OVERALL HEIGHT M > HANDLE HEIGHT m 0 z M 10.01V t'o 4.63' 0 CLZ ashc 'k C,) O �D ® 0j 2m O� c- v, 05 m to O� to co z- c a z 75 = a z- a a Ftp 0 0 0 0 n 0 < 0 3: 3: Cc) 3.61 15" 43,09"— No.43409 PRODUCT: Documents Prepared S)n PLASTPRO .. 43409 Ly.d.. F. Schmidt INC. DOOR P.E. N 'I, 10NAC O�\\' FIBERGLASS 7 24 UPDATE TO 6TH ED. (2017) FEC ASSEMBLY: CONSULTANTS, INC. 2 JK PART OR ASSEM 'P '21'0 VclrlC , FL 33595 t;t71 ? —1 3 15 I1vnATr TO RT14 Fn- (2014) FBC JK No.t 8;3.659.09197 —* -- 3—POINT LOCK DETAILS Ph— NO DATE REVISIONS By F8PE C.A. No. 9813 (0 2012 R.W.BUILD—00...LT—TS I... R:\Olents\Plastpm,Inc PERMANENT\A-Florida Product Approvals\FL-15210 HVHZ Flberglass-Impact Opaque and Glazed\C-Drawings\FL-15210(2017)\FL-15210.1-6.dwg,9.1 i c D o n z 'c c 3 , MrTT,7 o I a N , O_ 0� Z co O N A V n b m I m I O 24.25' 23.Ir' 150 I I . 8CH1j10'. No.43409 Deeumente Prepc d 9y. I F PRODUCT: Lyndon F. Schmidt i�•''. 4 PLASTPRO INC. '���S"At N FIBERGLASS DOOR P.E. No. 43409 i2�s/p A� �\\ Ico !H 111111 o N y 2 7'24 17 UPDATE TO 6TH ED. 2017 FBC JQY PART OR ASSEMBLY: mV�- BUILDING CONSULTANTS, INC. r- 3 9 15 UPDATE TO 5TH ED. 2014 FBC tl R P.O. Box 230, Volrico, FL 33595 IN N NO DATE 3-POINT LOCK DETAILS YV Phone No.: 813.859.9197 REVISIONS F13PE C.A. No. 9813 2012 R.W.BUILD—C.ONBU ...1— DIRECT TO MASONRY JAMB(TYP.) - 4" 49/16"JAMB P (SEE SHEET 7) N C. (TYP.) n 6" ` -1 n - i6 z � _ .y\ ���••• '•....••• \\ J ` J �� ^• '''JJTII!*1111 ttt\ o n m z SEE HINGE L 2X BUCK o N•: D TYP.HEAD DETAIL(TYP.) = i o Z o &JAMBS o G 1X BUCK S g i o ° m °c w -' DIRECT TO o m 5 o rm MASONRY7 o MASONRY7 D MASONRY 9 a m a a w ? OPENING OPENING TYP.HEAD E 9c0z &JAMBS w o 'tea FRAME z X o- U Cip U 2X BUCK 49/16"JAMB M aN J w ~ 2X BUCK 6-9/16"JAMB N �5 m a " DIRECT TO "' w v 00 �+ MASONRY a� JAMB(TYP.) — �I o Y -' (SEE SHEET 7) $ m a a $ ADAL SILx Y> o ��m b ONLY E 4 • N > BUCK ANCHORING STRIKE JAMB FRAME ANCHORING HINGEJAMS W w o x Masonry construction Zia >�Q 0 N `: �O O CONCRETE ANCHOR NOTE: DIRECT TO w - T.Concrete anchor locations of the comers may be adjusted to maintain the min. DIRECT TO n a $ edge dstancetomortarjoints. DIRECT TO MASONRY'4F as b 2 Concrete anchorlocations noted as TMX.ON CENTEIrmust be adjusted to M MASONRY MASONRY (`I) > maintain the min.edge distance to mortor joints,additional cor ete anchors Z8 1 X BUCK maybe required to ensure fhe•MAX.ON CENTER'dimension we not exceeded. G 1X BUCK 1 X BUCK G ^ i 3 Concrete anchor table 2X BUCK 9 N m ANCHOR ANCHOR >=MIN .MM.CLEARANCE MIN:CTEARANC_E 2X BUCK 5B 58 2X BUCK 2X BUCK L ;- l�'TYPE. e:SlZE EMBEDMEM TO MASONRY TO 1 -'EDGES• ANCHOR11 1XBUCK 11 DIRECT TOraecoN® 1/4• 1-1/4 2" 4 M MASONRY 11 a>E 02176112 = ELCO DIRECT TO 11 ❑ N.T.S. 9 u1rRAcoN 1/4• 1-1/4• 7• 4• MASONRY G 1XBUCK DWc.BY: JK m TAPCON 0 3/16' 1.1/4• AS SHOWN 1-1/2• 27 58 2XBUCK atx.Br: LFS 3 mlwwwc RB, I.WOOD SCREW INSTALLA17ON NOTE: LATCH&DEADBOLTDETAIL HINGE DETAIL HINGE DETAIL FL-15210.1 Maintain a minimum 5/8•edge distance.I•end distance.&I•o.c.spacing of imN Inswing wood screws to prevent the sp&tting of wood. ing OU15WIflg SHEET 10 OF 12 ru R:\OlentslMastpm,Inc PERMANEWRA-Florida Product Approvals\FL-15210 HVH2 Fiberglass-Impact Opaque and Glazed\C-Drawings\FL-15210(2017)\FL-15210.1-6.dwg,11.1 i I 1.25 1.4" 1.75' " I i W � W W P N O 3 2 S'O o0 t7 O ra a o� oz g I �,r P ry In = In A = In Ln c' m = �IL-.25- .96, oZ cZ c o 0 c _ o. yZ "i —0 2�Gy) ? N S 2 Oe go 6 6 0 030 66 N 0.65"—IIII V 1.25" an I I O �n T II 01 N 0.15" N a a I D O O P m P T _ A O a N 2 0,937" L !- �I.S' US,' x m O omN m F m ,SCFIM/� No.43409 In g PRODUCT: Dooumenta Prepared By. 2< PLASTPRO INC. Lyndon F. Schmidt ,'ii'Fs••��0�•'�6�``� _ C) FIBERGLASS DOOR P.E. No. 43409 k: 2 17 24 17 UPDATE TO 6TH ED. 2017 FBI; JK PART OR ASSEMBLY: @ BUILDING CONSULTANTS, INC. Io y X (n 1 13 9 15 UPDATE TO 5TH ED. 2014 FBC JK r��P.O. Box 230, VoIrloo, FL 33595 N N N0 1 DATE BY COMPONENTS vv Phone No.: 813.659.9197 REVISIONS FBPE CA. No. 9813 O 201 2 R.W.BUILDING CON SU-ITS INC. i I � I j BILL OF MATERIALS o L. IIEM R DESCRIP 10H MATERIAL =_- <=z A I X BUCK SG>=0.55 WOOD :V..- z * °O– o� B 2X BUCK SG>=0.55 WOOD `� 'C, Z- . �' .•• – C IX IM SPACE D 1/4"X 2 3/4HPFH ELCO OR ITW CONCRETE SCREW STEEL '''��Irerr r tti�`��`` o m 6 E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE o N.'z G 3/16 x 3-10/4'OP HBTW CONLOCK CRETE CING REWO ASTM C90 STEEL \ N o j o o W I 1/4"X 1-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL V a r m 2Q. . J 114-X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL c '` d K 1/4"X2-1/4"ITW CONCRETE SCREW STEEL E aZ L #10 X 2-1/7'PFH WOOD SCREW(1.15"MIN.EMBEDMENT) STEEL 8 ja: M 3/16"X2-1/4"ITW CONCRETE SCREW STEEL N 3/16"X 2-3/4"ITW CONCRETE SCREW STEEL P 1/4"X 2-1/4"PFH ELCO CONCRETE SCREW STEEL 1 POLY FIBER JAMB COMP./VINYL �o 2 FINGER JOINTED PINE FRAME WOOD 7 WEATHERSTRIP FOAM min e 8 DOOR BOTTOM SWEEP VINYL a5 m w 9 4!'X 4"BUTT HINGE STEEL 3w 6 11 #9 X 3/4"PFH WOOD SCREW STEEL a� m 22 3 POINT"TONGUE'MULTIPOINT LOCKSET(Mfg.BY HOPPE) STEEL o 23 MULTIPOINT STRIKE PLATE(TONGUE SYSTEM) STEEL o lix 25 LATCH AND DEADBOLT STRIKE PLATE(TONGUE SYSTEMA) STEEL a a g 27 LATCH STRIKE PLATE STEEL hg>- 28 DEADBOLT STRIKE PLATE(SECURITY) STEEL E 29 ADATHRESHOLD ALUM 30 OUTSWING THRESHOLD ALUM/WOOD 31 OUTSWING THRESHOLD ALUM/WOOD v 00 g 32 OUTSWING THRESHOLD ALUM/WOOD N N N 33 OUTSWING THRESHOLD ALUM/COMP o 34 OUTSWING THRESHOLD' ALUM/WOODD 36 INSWING THRESHOLD ALUM/COMP muaj 37 INSWING THRESHOLD ALUM/WOOD o o 38 INSWING THRESHOLD ALUM/COMP ¢Q 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS >j ro 55 #10 X 1-1/7'PFH SCREW STEEL $ 57 BACKING PLATE STEEL 58 #8 X 7'PFH WS STEEL O a 60 MULTIPOINT STRIKE PLATE STEEL �' m U 62 ENDURA TRILENNIUM 3000 LOCK ASSEMBLY STEEL N.-Z-02116112 = scaE N.T.S. ° ° DWG.B. JK m' CHV-B,s LFS 3 e DRAWING NO.: FL-15210.1 " S o b sHLEr 12 OF 12 L it