Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project information, wind pressures
lJJIi ASCE 7-10 Design Wind Loads Wind speed V= 170 mph Exp®sure 'C' 01E ,5YSeLq L5 For Wall Components Fr Cladding ASD Load Combination Coefficient: 0.6 easyseals.com Wind Pressures[psf]For use with Allowable Stress Design KZt= 1.0 Kd= 0.85 Enclosed Bldg GCpi= 0.18 Triburary area at least... Triburary area at least... Triburary area at least Triburary area at least Triburary area at least Triburary area at least Triburary area at least Triburary area at least Mean 10sgft 15sgft 20sgft 25sgft 30sgft 35sgft 40sgft 50sgft Roof Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Height (Interior) Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner u to: + + + + + + - + + - + I - + - + I - + - + I - + I - + - + - 15 ft +37.8-41.0 +37.8-50.6 +36.8 40.0 +36.8-48.6 +36.1-39.3 +36.1-47.2 +35.5-38.7 +35.5-46.1 +35.1-38.3 +35.1-45.2 +34.7-37.9 +34.7-44.5 +34.4-37.6 +34.4-43.8 +33.8-37.0 +33.8-42.7 16 ft +38.3-41.6 +38.3-51.3 +37.3140.5 +37.3-49.3 1 +36.6-39.8 +36.6-47.8 +36.0-39.3 +36.046.7 +35.6-38.8 +35.6-45.8 +35.2-38.4 +35.2-45.1 +34.9-38.1 +34.9-44.4 +34.31-37.6 +341-43.3 17 ft +38.8-42.1 +38.8-52.0 +37.81-41.1 +37.8-49.9 +37.1-40.3 +37.1-48.5 +36.5-39.8 +36.5-47.3 +36.0-39.3 1 +36.0-46.4 +35.6-38.9 +35.6-45.6 +35.3-38.6 1 +35.3-45.0 +34.7-38.0 +34.7-43.8 18 ft +39.3-42.6 +39.3-52.6 +38.2 41.6 +38.2-50.5 +37.5-40.8 +37.5-49.0 +36.9-40.3 +36.9-47.9 +36.5-39.8 +36.5 -47.0 +36.1-39.4 +36.1-46.2 +35.7-39.1 +35.7-45.5 +35.2-38.5 +35.2-44.4 20 +40.2-43.6 +40.2-53.8 +39.1-42.5 +39.1-51.7 +38.3-41.7 +38.3-50.1 +37.8-41.2 +37.8-49.0 +37.3-40.7 +37.3-48.0 +36.9-40.3 +36.9-47.2 +36.5-39.9 +36.5-46.5 36.0-39.4 +36.0-45.4 22 ft +41.0-44.4 +41.0-54.9 +39.9-43.4 +39.9-52.7 +39.1-42.6 +39.1-51.2 +38.5-42.0 +38.5-50.0 +38.0-41.5 +38.0-49.0 +37.6-41.1 +37.6-48.2 +37.3-40.7 +37.3-47.5 + -40.2 +36.7-06.3 46ft 41.7-45.3 +41.7-55.9 +40.6-44.2 +40.6-53.7 +39.8-43.4 +39.8-52.1 +39.2-42.8 +39.2-50.9 +38.7-42.3 +38.7-49.9 +38.3-41.9 +38.3-49.1 +38.0-41.5 +38.0-48.4 +37.4-40.9 +37.4-47.1 42.1-45.7 +42.1-56.4 +41.0-44.5 +41.0-54.1 +40.2-43.8 +40.2-52.6 +39.6-43.1 +39.6-51.3 +39.1-42.6 +39.1-50.3 +38.7-42.2 +38.7 49.5 +38.3 41.9 +38.3-48.8 +37.7-41.3 +37.7-47.5 42.4-46.0 +42.4-56.8 +41.3-44.9 +41.3-54.6 +40.5-44.1 +40.5-53.0 +39.9-43.5 +39.9-51.8 +39.4-43.0 +39.4-50.8 +39.0-42.6 +39.0-49.9 +38.6-42.2 +38.6-49.2 +38.0-41.6 +38.0-47.9 43.1-46.8 +43.1-57.7 +42.0-45.6 +42.0-55.4 +41.2144.8 +41.2-53.8 +40.51-44.2 +40.5-52.6 +40.0-43.7 +40.0-51.6 +39.61-43.2 +39.6-50.7 +39.2-42.9 +39.2-49.9 +38.61-42.2 +38.6-48.7 30 ft +43.7-47.4 +43.7-58.6 +42.6-46.3 +42.6-56.3 +41.8-45.5 +41.8-54.6 +41.1-44.8 +41.1-53.3 +40.6 44.3 +40.6-52.3 +40.2-43.9 +40.2-51.4 +39.8-43.5 +39.8-50.7 +39.21-42.9 +39.2-49.4 32 ft 1 +44.3-48.1 +44.3-59.4 +43.2-46.9 1 +43.2-57.0 1 +42.3-46.1 +42.3-55.4 1 +41.7-45.4 +41.7-54.1 +41.2-44.9 +41.2-53.0 +40.7-44.5 +40.7-52.1 +40.3-44.1 +40.3-51.4 +39.7-43.5 1 +39.7-50.1 34 ft +44.9-48.7 +44.9-60.1 +43.7-47.5 +43.7-57.8 +42.9-46.7 +42.9-56.1 +42.2-46.0 +42.2-54.8 +41.7-45.5 +41.7-53.7 +41.2-45.1 +41.2-52.8 +40.9-44.7 +40.9-52.0 +40.2-44.0 +40.2-50.7 35 ft +45.2-49.0 +45.21-60.5 +44.0-47.8 +44.0-58.1 +43.1-47.0 +43.1-56.4 +42.5-46.3 +42.5-55.1 +42.0-45.8 +42.0-54.0 +41.5-45.3 +41.5-53.1 +41.1-44.9 +41.1-52.3 j +40.5-44.3 +40.5-51.0 36 ft +45.4-49.3 +45.4-60.8 +44.2-48.1 +44.2-58.5 +43.4-47.2 +43.4-56.8 +42.7 1-46.6 +42.7-55.4 +42.2-46.1 +42.2-54.4 +41.7-45.6 +41.7-53.4 +41.3-45.2 +41.3-52.7 +40.7-44.5 +40.7-51.3 38 ft +46.0-49.9 +46.0-61.5 +44.8-48.6 +44.8-59.1 +43.9-47.8 +43.9-57.4 +43.2-47.1 +43.2-56.1 +42.7-46.6 +42.7-55.0 +42.2-46.1 +42.2-54.1 +41.8-45.7 +41.8-53.3 +41.21-45.1 +41.2-51.9 40 ft +46.5-50.4 +46.5-62.2 +45.2 1-49.2 +45.2-59.8 +44.4-48.3 +44.4-58.0 +43.747.6 +43.7-56.7 +43.1-47.1 +43.1-55.6 +42.7.-46.6 +42.7-54.6 +42.3-46.2 +42.3-53.8 +41.61-45.5 +41.6-52.5 42 ft +46.9-50.9 +46.91-62.9 +45.7-49.7 +45.7-60.4 +44.8-48.8 +44.8-58.6 +44.1-48.1 +44.1-57.3 +43.6 1-47.6 1 +43.6-56.2 1 +43.11-47.1 1 +43.11-55.2 +42.71-46.7 +42.71-54.4 +42.0-46.0 +42.0-53.0 44 ft +47.4-51.4 +47.41-63.5 +46.2-50.2 +46.2-61.0 +45.3-49.3 +45.3-59.2 +44.61-48.6 +44.6-57.8 +44.0-48.0 +44.0-56.7 +43.5-47.6 +43.5-55.8 +43.1-47.2 +43.1-54.9 +42.4-46.5 +42.4-53.6 63.8 +46.4-50.4 +46.4-61.3 +45.5-49.5 +45.5-59.5 +44.8-48.8 +44.8-58.1 +44.2-48.3 +44.2-57.0 +43.8-47.8 +43.8-56.0 +43.3-47.4 +43.3-55.2 +42.6-46.7 +42.6-53.8 45 ft +47.6-51.7 +47.61- 46 ft +47.9-51.9 +47.9-64.1 +46.6-50.6 +46.6-61.6 +45.7-49.8 +45.7-59.8 +45.0-49.1 1 +45.0-58.4 +44.4 48.5 +44.4-57.2 +44.048.0 +44.0-56.3 +43.5-47.6 +43.5-55.4 +42.8-46.9 1 +42.8-54.1 48 ft +48.3-52.4 +48.3-64.6 +47.0 1-51.1 +47.0-62.1 +46.1-50.2 +46.1-60.3 +45.41-49.5 1 +45.4-58.9 1 +44.8-48.9 +44.8-57.8 +44.4-48.4 +44.4-56.8 +43.91-48.0 +43.9-55.9 +43.2-47.3 +43.2-54.5 50 ft +48.7-52.8 +48.7-65.2 +47.41-51.5 +47.4-62.6 +46.5-50.6 +46.5-60.8 +45.8-49.9 +45.8-59.4 +45.2-49.3 1 +45.2-58.3 1 +44.7-48.9 +44.7-57.3 +44.3-48.4 +44.3-56.4 1 +43.6-47.7 +43.6-55.0 52 ft +49.1-53.3 1 +49.1-65.7 +47.8j-52.0 +47.81-63.2 +46.91-51.1 +46.9-61.3 +46.2-50.3 +46.2-59.9 +45.6-49.8 +45.6-58.7 +45.3.1-49.3 +45.1-57.8 +44.71-48.8 +44.71-56.9 +44.0-48.1 +44.0-55.5 54 ft +49.5-53.7 +49.5-66.3 +48.2-52.4 +48.2-63.7 +47.3-51.5 +47.3-61.8 +46.5-50.7 +46.5-60.4 +46.0-50.2 +46.0-59.2 +45.5-49.7 +45.5-58.2 +45.0-49.2 +45.0-57.4 +44.3-48.5 +44.3-55.9 55 ft +49.7-53.9 +49.7-66.5 +48.4-52.6 +48.4-63.9 +47.4-51.7 +47.4-62.1 +46.7-50.9 +46.7-60.6 +46.1-50.3 +46.1-59.4 +45.6-49.9 +45.61-58.4 +45.2-49.4 +45.2-57.6 +44.51-48.7 +44.5-56.1 56 ft +49.9-54.1 +49.9-66.8 +48.6-52.8 +48.61-64.2 +47.6-51.9 +47.6-62.3 +46.9-51.1 +46.9-60.8 +46.3-50.5 +46.3-59.7 +45.8-50.0 +45.8-58.7 +45.4-49.6 +45.4-57.8 +44.7-48.9 +44.7 J56358 ft +50.2-54.5 +50.2-67.3 +48.9-53.2 +48.9-64.6 +48.0-52.2 +48.0-62.7 +47.3-51.5 +47.3-61.3 +46.7-50.9 +46.7-60.1 +46.2-50.4 +46.2-59.1 +45.7-50.0 +45.7-58.2, +45.0-49.2 1+45.0 60ft +50.6-54.9 +50.6-67.8 +49.3-53.6 +49.3-65.1 +48.3-52.6 +48.3-63.2 +47.6-51.9 +47.6-61.7 +47.0-51.3 +47.0-60.5 +46.5-50.8 +46.5-59.5 +46.0-50.3 +46.0=58.6 +45:3 49.6 +45.3 (n •Design conforms to the Florida Building Code 6th Ed(2017). •Wind Speed noted above Is ultimate design wind speed(3-second gust). •Zones 4&5("Interior"and"comer"zones,respectively)are as shown toP�7_n. a a Valid only h gineer's LU •Tabulated design wind loads are based on ASCE 7-10 specifications for •Plus(+)&minus(-)signs signify pressures acting toward and away from the right,where the dimension"a"is the minimum of 10%of the building's O components and cladding based on design criteria as noted herein. the exterior component or cladding surface,respectively. least horizontal dimension or 40%of the mean roof height,but never less signature rai ed seal Z •Where this document Is used for permit,applicability of design criteria •Where"Mean(average)Roof Height"cannot be determined,peak roof than T-O"or 4%of the least horizontal dimension.• noted herein(Basic Wind Speed,Exposure Category,Risk Category,etc.) height shall be used,except that eave height shall be used for roof angle •This specification is valid only for use with structures NOT located in the shall be verified by the contractor&building official prior to construction. less than or equal to 10°.Round up to values shown upper one-half of an Isolated hill,ridge or escarpment. Jan 29 2•This specification may be used in conjunction with engineering under •Wind pressures are applicable to all building floors. •This specification is valid for use with buildings of any Risk Category,LLI separate certification(by this engineer or by others)using Allowable Stress •Tabulated wind pressures are valid for all roof slopes;no reduction for Including essential facilities and buildings or other structures thatz Design(ASD), roof slope510°has been considered. represent a substantial hazard to human life in the event of failure. eanooChristian Langle PE LL •Refer to the above-noted ASCE 7 standard for descriptions and •Tributary Area noted in table effective wind area Is equal to the •Design Is based on structure classification as Enclosed Bldg Peak Height U P ry ( ) q g PE definitions of all design criteria. minimum of[height x width]or[ht x ht/3].Round down to values shown. wni i ci cvnnoN FL #67382 #31124 1200 N Federal Hwy,#200,Boca Raton,FL 33432 Copyright©2020 Easy Seals rev 0120 Doc No.A10LS.170C