Supplement
Permit 2002-0033
Concrete will be a minimum 3000 PSI, 4"thick or greater.
The Thickened Edge is approximately 8" thick and is at the approximate
elevation as the original footings of the home. It will be a little thicker for
additional strength.
The radius is approximately 13' and will be slightly eased on the western
side of the new pour to conform to the existing walkway.
The T/E footing is being poured as a monolithic pour with the slab. .
Use 2 - #3 Rebar for the footing. Y located 4" off bottom and 1 located
approximately 3.5" down from the top edge and 2.5" in from the outside
edge. #3 rebar is being used for the radiused edge.
#4 Rebar Dowels will be placed approximately 2' apart into existing
footings where possible, Alj o , ,-jro E x•s>>-ja P Sri a -A.,- 3' 9por-2.4%
5 - 18" Sonotubes will be placed approximately i'from the outer edge for
plantings.
The highest elevation of the slab will be approximately 23" above the
existing ground surface at the greatest. This area may be back-filled at a