Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product sheet
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation. Residential Lowboy Electric Water Heater The Lowboy Electric Models Feature: ■Blanketed & Non-Blanketed Models Available—Non-Blanketed models (RE120L6, RE230LN6, RE240LN6, RE250LN6) help to decrease overall installation time and are perfect for new construction applications. Blanketed models (RE130L6, RE230L6, & RE240L6) provide more installation flexibility and are ideal for replacement applications. ■Low Restrictive Brass Drain Valve—Durable tamper proof design. ■Fully Automatic Thermostat Controls—Fast acting surface-mount thermostat with high limit energy cut-off (manual reset) for safety. ■Direct Heat Transfer with Immersed Elements—Transfers heat directly and efficiently to the water. Screw-in style. ■Factory-Installed Hydrojet® Total Performance System—Sediment reducing device that also increases first hour delivery of hot water while minimizing temperature build-up in tank. ■Vitraglas® Lining—An exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas®) is fused to the steel surface by firing at a temperature of over 1600°F (871°C). ■Insulation System—Non-CFC foam covers the sides and top of the tank, reducing heat loss. This results in less energy consumption, improved efficiencies, and jacket rigidity. Blanketed models additionally use a supplied flexible fiberglass insulation blanket. ■Water Connections—3⁄4" (19mm) NPT factory-installed true dielectric fittings extend water heater life and simplify water line connections. ■Factory-Installed Heat Traps—Design incorporates a flexible disk that reduces heat loss in piping and eliminates the potential for noise generation. (Except for RE120L6). ■Protective Magnesium Anode Rod—Provides added protection against corrosion for long-term, trouble-free service. ■Non-Simultaneous Operation—Non-Simultaneous operation indicates only one heating element will operate at a time and is standard construction from the factory. Simultaneous Operation indicates both heating elements have the potential to operate at the same time and is available as an option (must be specified when ordering). ■Voltages Available—120V, 208V, 240V, 277V, 480V. ■Single Phase or Three Phase Operation Available—120V & 277V may only be wired for single phase operation. ■T&P Relief Valve—Installed, side T&P is standard. Optional top T&P location is available. ■Design evaluated by ETL in accordance with Part 280.707(d) of HUD Mobile Home Construction and Safety Standards for Energy Efficiency. Photo is of RE240LN6 1203-C-1118 Copper Screw Type Immersion Element (INCOLOY® type immersion element available upon request) 6 or 10-Year Limited Tank Warranties / 6 or 10-Year Limited Warranty on Component Parts. For more information on warranty, please visit www.bradfordwhite.com For products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater. ©2018, Bradford White Corporation. All rights reserved. For field service, contact your professional installer or local Bradford White sales representative. Sales 800-523-2931 n Fax 215-641-1612 Technical Support 800-334-3393 n Email techserv@bradfordwhite.com Warranty 800-531-2111 n Email warranty@bradfordwhite.com International: Telephone 1-215-641-9400 n Email international@bradfordwhite.com / www.bradfordwhite.com Ambler, PA Lowboy Models C.E.C. Listed ModelNumber NominalGal.Capacity AFloor toTop ofHeater in. Approx.ShippingWeight lbs. EFloor toT&PConn. in. BJacketDia. in.GPH*Imp. Recovery at90°F Rise* GPH*U.S. ModelNumber NominalLiterCapacity AFloor toTop ofHeater mm. Approx.ShippingWeight kg. EFloor toT&PConn. mm. BJacketDia. mm. Recovery at50°C Rise* CFloor toWaterConn. in. CFloor toWaterConn. mm. RE120L6† RE130L6** RE230LN6 RE230L6** RE240LN6 RE240L6** RE250LN6 591/8 593/8 RE120L6† RE130L6** RE230LN6 RE230L6** RE240LN6 RE240L6** RE250LN6 591/8 593/8 24 7/16 29 9/16 29 9/16 29 9/16 32 1/16 32 3/8 33 5/16 621 751 751 751 814 822 846 25 11/16 31 5/16 31 5/16 3113/16 34 5/16 34 5/8 36 1/16 652 795 795 808 872 879 916 DC/L ofWaterConn. in. DC/L ofWaterConn. mm. 8 8 8 8 8 8 8 203 203 203 203 203 203 203 GWaterConn.NPT in. GWaterConn.NPT mm. 3/4 3/4 3/4 3/4 3/4 3/4 3/4 19 19 19 19 19 19 19 18 15/16 / 25 11/16 23 9/16 / 31 5/16 23 9/16 / 31 5/16 22 13/16 / 3113/16 23 9/16 / 34 5/16 23 9/16 / 34 5/8 24 5/16 / 36 1/16 481 / 652 598 / 795 598 / 795 579 / 808 598 / 872 598 / 879 618 / 916 EFloor toT&PConn. in. EFloor toT&PConn. mm. 19 1/8 / 25 5/8 215/8 / 30 1/2 23 1/4 / 30 3/4 24 1/8 / 30 5/8 23 3/4 / 32 3/4 24 1/8 / 33 3/8 24 1/2 / 34 3/8 486 / 651 600 / 775 591 / 781 613 / 778 603 / 832 613 / 848 622 / 873 18 20 23 22 24 1/2 24 26 457 508 584 559 622 610 660 65 99 102 108 126 140 173 29 45 46 49 57 64 78 19 28 28 28 37 38 45 FirstHourRating(Gal.)U.S.Gal.Imp.Gal. — 42 41 42 45 49 61 UniformEnergyFactor — 0.92 0.92 0.92 0.92 0.91 0.92 FirstHourRating(Liters)Liters — 159 155 159 171 186 231 DOERatedStorageVolume(Gal.) — 26 26 26 34 35 43 DOERatedStorageVolume(Liters) — 98 98 98 129 132 163 UniformEnergyFactor — 0.92 0.92 0.92 0.92 0.91 0.92 16 23 23 23 31 32 37 21 21 21 21 21 21 21 18 18 18 18 18 18 18 72 106 106 106 140 144 170 80 80 80 80 80 80 80 Liters/Hour Residential Electric Water Heater General: Meets NAECA Requirements. All models ETL listed. These heaters are wired inter-locking (Non-Simultaneous, Single Phase) 240V with two 4500W elements, unless otherwise specified. All water and electrical connections are 3/4" (19mm) NPT. All models certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa.) Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. RecoveryGPH Temperature Rise °F Wattage 1500W 2000W 2500W 3000W 3500W 4000W 4500W 5000W 5500W 6000W 60 10 14 17 21 24 28 31 34 38 41 80 8 10 13 15 18 21 23 26 29 31 90 7 9 11 14 16 18 21 23 25 28 100 6 8 10 12 14 16 19 21 23 25 120 5 7 9 10 12 14 15 17 19 21 s s(GPH based on Non-Simultaneous operation, when Simultaneous operation the GPH will approximately double.)• = Not available on RE130L and RE230LN6. **Models include supplied insulation blanket (2" thick). Dimensions in charts above do not include blanket thickness. For 10 year models, change suffix “6” to “10”. * Based on 4500W/4500W, Non-Simultaneous operation. All models available with optional top T&P location (Plugged). † Exempt from ASHRAE 90.1b (current standard). Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings. VoltageWattageLimitations forSimultaneousOperation 1500W / 1500W 2000W / 2000W 2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W yes no no no no no no no no no 120V yes yes yes yes yes •yes yes •yes no no 208V yes yes yes yes yes yes yes yes •yes no 240V yes yes yes yes no yes •yes •yes no •yes 277V yes yes yes yes no yes •yes •yes no •yes 480V VoltageWattageLimitations forNon-SimultaneousOperation 1500W / 1500W 2000W / 2000W 2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W yes yes yes yes no no no no no no 120V yes yes yes yes yes •yes yes •yes •yes •yes 208V yes yes yes yes yes yes yes yes •yes yes 240V yes yes yes yes no yes •yes •yes no •yes 277V yes yes yes yes no yes •yes •yes no •yes 480V B G G D 8" Anode(RE130L6, RE230LN6,RE240LN6, & RE250LN6 only) OptionalTop T&PLocation C A •E •“E” dimension listed as side/top. Printed in U.S.A.1203-C-1118