Loading...
HomeMy WebLinkAboutProduct Approval 216/2020 Florida Building Code Online 411 BCIS Home j Log In 4User Registration HotTopics Submit Surcharge Stats&Facts I publications I Contact Us BCIS Site Map Links Search L iorda =a�Product Approval 4 �ji }�` USER:Public User Product AP�roval Menu>Product or Application Search>Application List>Application Detail FL# F.L16546-R11 - - - Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Clopay Building Products Company Address/Phone/Email 8585 Duke Blvd. Mason, OH 45040 (513) 770-6062 mwesterfield@clopay.com Authorized Signature Scott Hamilton shamllton@clopay.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer -! Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Scott Hamilton Evaluation Report - " Florida License PE-63286 Quality Assurance Entity Intertek Testing Services NA,Inc. - QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By Gary Pfuehler J Validation Checklist- Hardcopy Received Certificate of Independence FL16546 R11 CQ[ Certification of Independence .of Validation Entity_ Gary. Pfuehler 2016-02-19.pdf FL16546 R11 COI Statement on Independence of Evaluation Entity_ ScottHarrilton 2016-02-19.pdf Referenced Standard and Year(of Standard) Standard Year ANSI/DASMA 108 2005 ANSI/DASMA 115 2005 ASTM E1886 2005 ASTM E1996 2009 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL16546 R11 Equiv 20170809- FBC- DASMA 108 equiv.pdf FL16546 R11 Equiv 20170809- FBC- DASMA 115 equiv pdf httpsJAw Nv.floridabuilding.org/pr/pr_app dtl.aspx?parartr--wGEVXQwtDq\,gqu2W%2bnFgUMAgulPvy/2FMmFvBgsvYdca%2fzGZWcCAmK5Q%3d%3d 1/5 2/6/2020 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/18/2018 Date Validated 02/13/2019 Date Pending FBC Approval 02/13/2019 Date Approved 04/16/2019 Summary of Products Go to Page 0 '40 Page 1/4'0 0 FL# I Model,Number or Name f Description 16546.1 01 W5-16-HY PAN-2F153/6: 73, 1500, Steel Pan(min. 25 ga.) Double-Car(9'2"to 16'0"wide) 75, 76, 190,84A,94,42,428, 48,48B, WINDCODE@ WS Garage Door 55,41`,4RST, 6RST,4RSF, 6RSF, GD5S, GD5SV,GR5S,GR5SV,AR5S,AR5SV, ED5S, ED5SV Limits of Use Installation Instructions j Approved for use in HVHZ: No FL16546 R11. II 101922-A-Revl5.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:+32 PSF/-32 PSF Evaluation Reports Other:Solid doors(no glazing)or doors with optional impact- FL16546 R11 AE CBPC 131211-A.pdf resistant glazing are impact-resistant(large missile impact). Created by Independent Third Party: No 16546.2 02 W5-16-HY PAN-2F153/6: 73, 1500, Steel Pan(min. 25 ga.) Double-Car(9'2"to 16'0"wide) 75,76, 190, 84A, 94,42,428,48,4813, WINDCODE@ W5 Garage Door 55,4F,4RST, 6RST,4RSF,6RSF,GD5S, GD5SV, GR5S,GR5SV,ARSS,ARSSV, EDSS, ED5SV Limits of Use Installation Instructions Approved for use in HVHZ: No FL16546 R11 II 101922-B-Rev15.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +32 PSF/-32 PSF Evaluation Reports Other:The standard glazing available for this product meets the FL16546 R11 AE CBPC 131211-A:pdf wind load requirements of the building code but DOES NOT meet Created by Independent Third Party: No the impact resistant requirement for wlndbome debris regions. 16546.3 03 W8-16 PAN-2F443: GD4S, GR4S, Gallery/Artistry/Expressions: Steel Pan (min.24 ga.) Double-Car ED4S,AR4S (9'2"to 16'2"wide)WINDCODE@ W8 Garage Door with Optional Impact-Resistant Lites Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16546 R11 II 104791-Rev05.pdf Approved for use outside:'HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes . Created by Independent Third Party: No Design Pressure: +46 PSF/-52 PSF Evaluation Reports Other:Max.Wind Speed(V_ult): 170 MPH. Solid doors(no FL16546 R11 AE CBPC 131211-A.pdf glazing)or doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No resistant (large missile impact). 16546.4 04 W6-16 PAN-21`153: 73, 1500,75, Steel Pan(min. 25 ga.)Double-Car(9'2"to 16'2"wide) 190,84A,94,42,4213,48,4813, 55, WINDCODE@ W6 Garage Door with Optional Impact-Resistant Lites 4RST, 6RST,4RSF, 6RSF, GD5S, GD5SV, GR5S, GR5SV,AR5S,AR5SV, ED5S, ED5SV Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL16546 R11 II 104710-A-Rev03.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:+36 PSF/-42 PSF Evaluation Reports Other:Max. Wind Speed(V_ult): 170 MPH. Solid doors(no FL16546 R11 AE CBPC 131211-A.pdf standard glazing)are impact-resistant(large missile Impact). Created by Independent Third Party: No 16546.5 _: 05 W6-16 PAN-2F153: 73, 1500, 75, Steel Pan(min. 25 ga.)Double-Car(9'2"to 16'2"wide) 190,84A,94,42,48,55,4RST, 6RST, WINDCODEO W6 Garage Door 4RSF, 6RSF,GD5S,GD5SV,GR5S, GR5SV,ARSS,ARSSV, ED5S, EDSSV Limits of Use Installation Instructions Approved for use in HVHZ: No FL16546 R11 II 104710-B-Rev03.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure:+36 PSF/-42 PSF Evaluation Reports Other:The standard glazing available for this product meets the FL16546 R11 AE CBPC 131211-A.pdf wind load requirements of the building code but DOES NOT meet Created by Independent Third Party: No the impact resistant requirement for windbome debris regions. https:/Mrnw.floridabuilding.org/pr/pr appdtl.asp�C?param=wfEVXOwtDq\gqu2w%2bnFgUMP�quIPWLFMmFvBgsdYdca%2fzGZWcCAmK5Q%3d%3d 215 2/6/2020 Florida Building Code Online 16546.6 06 W6-16 PAN-21`156: 76, 2RST Steel Pan(min. 25 ga.)Double-Car(9'2"to 16'2"wide) WINDCODEO W6 Garage Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16546 R11 II 104710-A-Rev03.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +36 PSF/-42 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors(no FL16546 R11 AE CBPC 131211-A.pdf standard glazing)are impact-resistant(large missile Impact). Created by Independent Third Party: No 16546.7 `07 W6-16 PAN-2F156: 76, 2RST I Steel Pan(min. 25 ga.) Double-Car(9'2"to 16'2"wide) ` I WINDCODE®W6 Garage Door Limits of Use Installation Instructions Approved for use in HVHZ:No FL16546 R11 II 104710-B-Rev03.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure:+36 PSF/-42 PSF Evaluation Reports Other:The standard glazing available for this product meets the FL16546 R11 AE CBPC 131211-A.pdf wind load requirements of the building code but DOES NOT meet Created by Independent Third Party: No the impact resistant requirement for windbome debris regions. 16546.8 08 W5-16 PANSP-21`153/6: 73SP, 15SP, I Steel Pan(min. 25 ga.)Double-Car(9'2"to 16'0"wide) GD5SSP, GDSSSPV, 76SP,76VSP WINDCODEO WS Garage Door Limits of Use I Installation Instructions Approved for use in HVHZ: No FL16546 R11 ii 104818-A-RevOI-signed.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:+32 PSF/-37 PSF Evaluation Reports Other:Solid doors(no glazing)or doors with optional impact- FL16546 R11 AE CBPC 131211-A.pdf resistant glazing are impact-resistant(large missile impact). Created by Independent Third Party: No 16546.9 I 09 W5-16 PANSP-2F153/6: 73SP, 15SP, Steel Pan(min. 25 ga.) Double-Car(9'2"to 16'0"wide) GDSSSP, GD5SSPV,76SP,76VSP WINDCODE@ WS Garage Door Limits of Use Installation Instructions Approved for use In HVHZ: No FL16546 R11 II 104818-B-RevOl-signed.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:No Created by Independent Third Party: No Design Pressure: +32 PSF/-37 PSF Evaluation Reports Other:The standard glazing available for this product meets the FL16546 R11 AE CBPC 131211-A.pdf wind load requirements of the building code but DOES NOT meet Created by Independent Third Party: No the impact resistant requirement for windbome debris regions. 16546.10 10 W6-09 DSIE-1A171: 2050, 2051, Double-skin Insulated EPS(exterior skin 27 ga, min.; interior skin 2053,4050,4051,4053, 62, 64,-65, 29 ga. min.)Single-Car(up to 9'0"wide)WINDCODE®W6 Garage 62G, 62LG,64G, SDP38,SFL38,SRP38, Door 134, 135, 136, 6130, 6131, 6133 Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16546 R11 II 104814-A-Rev00.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes- Created by Independent Third Party: No Design-Pressure: +36 PSF/-44 PSF Eva luation'Reports Other. Max. Wind Speed(V_ult): 170 MPH.Solid doors (no FL16546 Rll AE CBPC 131211-A.pdf glazing)are impact-resistant(large missile impact). Created by Independent Third Party: No 16546.11 11 W6-09 DSIE-1A171: 2050, 2051, Double-skin Insulated EPS (exterior skin 27 ga, min.; interior skin 2053,4050,4051,4053, 62, 64, 65,, 29 ga. min.)Single-Car(up to 9'0"wide)WINDCODE@ W6 Garage 62G, 62LG, 64G,SDP38, SFL38, SRP38, Door 134, 135, 136, 6130,6131, 6133 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16546 Rll II 104814-B-Rev00.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure:+36 PSF/-44 PSF Evaluation Reports Other:The standard glazing available for this product meets the FL16546 R11 AE CBPC 131211-A.pdf wind load requirements of the building code but DOES NOT meet Created by Independent Third Party: No the impact resistant requirement for windbome debris regions. 16546.12 12 W6-09 DSIU-1F471:•GD2SU,GR2SU, Double-skin Insulated Intellicore (exterior skin 27 ga. min.; interior GD2111, GR2LU,AR2SU,AR2111, ED2SU, skin 27 ga. n-n.)Single-Car(up to 9'0"wide)WINDCODE@ W6 ED2LU,9202, HDPC20, 7202, 8202, Garage Door with Optional Impact-Resistant Utes MFC68U, 9205, HDPR20, 7205, 8205, MFR68U Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16546 Rll II 104432-A-Rev05.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton'FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:+38 PSF/-44 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH.Solid doors(no FL16546 R11 AE CBPC 141219-B.pdf glazing)or doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No resistant (large missile impact). https:/Ammv.floridabuilding.org/pr/pr_app dtl.aspx?pararri=wGEVXQwtDq\igqu2w%2bnFgUMAgu[Pw2FMmFvBgsvYdca%2fzGZWcCAmK5Q%3d%3d 3/5 2/6/2020 Florida Building Code Online 16546.13 13 W6-09 DSIU-1F471: GD2SU, GR2SU, Double-skin Insulated Intellicore(exterior skin 27 ga. min.; interior GD2LU2LU ,GR2LU,AR2SU,AR , ED2SU, skin 27 ga. min.)Single-Car(up to 97 wide)WINDCODEp W6 ED2W,9202, HDPC20, 7202,8202, Garage Door MFC68U,9205, HDPR20, 7205, 8205, MFR68U Limits of Use Installation Instructions Approved for use in HVHZ: No FL16546 R11 II 104432-B-Rev05.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other:Doors with standard glazing meet the wind load FL16546 R1 t AE CBPC 141219-B.pdf requirements of the building code but DO NOT meet the Impact Created by Independent Third Party: No resistant requirement for windbome debris regions. I 16546.14 114 W6-16 DSIU-11=471: GD2SU,GR2SU, Double-skin Insulated Intellicore(exterior skin 27 ga. min.; interior GD2111, GR2LU,AR2SU,AR21-1.1, ED2SU, skin 27 ga. min.) Double-Car(9'2"to 16'2"wide)WINDCODE@ W6 ED2W, 9202, HDPC20, 7202,8202, I Garage Door MFC68U,9205, HDPR20, 7205, 8205, (MFR68U Limits of Use Installation Instructions Approved for use in HVHZ:Yes I FL16546 RLI 11 104320-A-Rev03.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-42 PSF Evaluation Reports j Other: Max. Wind Speed(V_ult): 170 MPH. Solid doors(no FLL6546 Ril .AE CBPC 141219-B.pdf glazing)or doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No j resistant (large missile impact). 16546.15 15 W6-16 DSIU-1F471: GD2SU,GR2SU, Double-skin Insulated Intellicore(exterior skin 27 ga. min.; interior GD2W,GR2111, AR2SU,AR2LU, ED2SU, skin 27 ga. min.) Double-Car(9'2"to 16'2"wide)WINDCODE®W6 ED2LU, 9202, HDPC20,7202,8202, Garage Door MFC68U, 9205, HDPR20, 7205, 8205, MFR68U Limits of Use Installation Instructions Approved for use in HVHZ:No FL16546 Rll II 104820-13-Rev03.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:No Created by Independent Third Party: No Design Pressure: +38 PSF/-42 PSF Evaluation Reports Other:Doors with standard glazing meet the wind load FL16546 Rll AE CBPC 141219-B.pdf requirements of the building code but DO NOT meet the Impact Created by Independent Third Party: No resistant requirement for windbome debris regions. 16546.16 16 W6-18 DSIE-1F471:.GD2SP,GR2SP, Double-skin Insulated EPS (exterior skin 27 ga, min.; interior skin GD21_P,GR21_13,AR2SP,ARKP, ED2SP, 27 ga. min.) Double-Car(16'4"to 18'2"wide)WINDCODE@ W6 ED2LP,4302, HDGC, 6202, MFC68, Garage Door with Optional Impact-Resistant Lites 4305,HDGR, 6205, SFR68, MFR68 Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16546 R11 II 104810-A-Rev04-signed.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:+38 PSF/-42 PSF Evaluation Reports Other: Max. Wind Speed(V_ult): 170 MPH. Solid doors(no FL16546 R11 AE CBPC 141219-B.pdf glazing).ordoors with opt Iona I-Impact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). 16546.17 16 W6-18 DSIE-1F471: GD2SP,GR2SP, Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin GD2LP GR2LP,AR2SP,AR21_P, ED2SP, 27 ga. min.) Double-Car(16'4"to 18'2"wide)WINDCODE@ W6 ED2LP,4302, HDGC,6202, MFC68, Garage Door 4305, HDGR, 6205,SFR68, MFR68 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16546 Rll II 104810-B-Rev04-signed.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-42 PSF Evaluation Reports . Other:Doors with standard glazing meet the wind load FL16546 Rll AE CBPC 141219-B.pdf requirements of the building code but DO NOT meet the impact Created by Independent Third Party: No resistant requirement for windbome debris regions. 16546.18 18 W6-18 DSIU-iF471: GD2SU, GR2SU, Double-skin Insulated Intellicore(exterior skin 27 ga. min.; interior GD2W, GR2LU,AR2SU,AR2111, ED2SU, skin 27 ga. min.) Double-Car(16'4"to 18'2"wide)WINDCODE@ W6 ED2LU,9202, HDPC20, 7202,8202, Garage Door with Optional Impact-Resistant L.ites MFC68U, 9205, HDPR20, 7205, 8205, MFR68U Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16546 Rll II 104821-A-Rev04.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-42 PSF Evaluation Reports Other: Max.Wind Speed (V_ult): 170 MPH.Solid doors(no FL16546 Rll AE CBPC 141219-B.pdf glazing)or doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). 16546.19 19 W6-18 DSIU-1F471: GD2SU, GR2SU, Double-skin Insulated Intellicore(exterior skin 27 ga. min.; interior https://wmv.floridabuilding.org/pr/pr app dtl.aspx?parani=mGEVXQwtDq�gqu2w%2bnFgUMAgu[Pv2FMmFvBgsvYdca%2fzGZWeCAmK5Q°/`3d%3d 4/5 2/6/2020 Florida Building Code Online GD2W,GR2LU,AR2SU,ARKU, ED2SU, skin 27 ga, min.) Double-Car(16'4"to 187"wide)WINDCODE@ W6 ED2LU,9202, HDPC20, 7202, 8202, Garage Door MFC68U, 9205, HDPR20, 7205,8205, MFR68U Limits of Use Installation Instructions Approved for use in HVHZ: No FL16S46 Rll II 104821-B-Rev04.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure:+38 PSF/-42 PSF Evaluation Reports Other:Doors with standard glazing meet the wind load FL16546 R11 AE C8PC 141219-13.pdf requirements of the building code but DO NOT meet the impact Created by Independent Third Party: No resistant requirement for windbome debris regions. -- j 16546.20 120 W8-09 DSIU-1F471: GD2SU,GR2SU, Double-skin Insulated Intellicore(exterior skin 27 ga. min.; interior f I GD2LU,GR2LU,AR25U,AR2LU, ED25U, skin 27 ga. con.)Single-Car(up to 9'0"wide)WINDCODE@ W8 f ED2LU,9202, HDPC20,7202,8202, Garage Door with Optional Impact-Resistant Utes MFC68U,9205, HDPR20, 7205, 8205, MFR68U Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16546 1111 H 104435-Rev05.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No i Design Pressure: +54 PSF/-60 PSF Evaluation Reports j Other:Max.Wind Speed(V_ult): 170 MPH. Solid doors(no FL.16546 R11 Ac CBPC 141219-B.pdf j glazing)or doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No resistant (large missile in-pact). Go to Page 0 4 Page 1/40 0 Back IVexY Contact us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::PrIyaN Statement::Accessibility.Statement:: Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: LPE-E 91 Ir check Credit Card Safe a https:lAmAw.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDqvgqu2w%2bnFgUMAgulPv,2FMmFN,BgsvYdca%2fzGZWeCAmK5Q%3d%3d 5/5 MODELS SHORT .LONG MODELS FLUSH GROOVED SHEET• REVISIONS CLOPAY GD2SU, GR2SU GD2LU, GR,-LU CLOPAY CLASSIC 9202,.NDPC20 9205, HDPR20 9' REV- NO. ZONE: DATE: ECN NO. APPVC: DESCRIPTION GALLERY ...._ I 12/26/14 H LI4AR2SU AR2LU HOLMES CLASSIC 7202 � 7205 05 SH � ADDED EMBEDMENT TO FASTENERS. TR ART TR '--- FR68U EAL, ED25U � ED2lU IDEAL CLASSIC 6202, MFC66u 8205, t+ --�� —_-� XPRE I OPTIONAL GLAZING MAY BE STANDARD (OSB OR BETTER) Q OR IMPACT RESISTANT GLAZING. I:AXIMUM GLAZING SIZE (DLO) IS 38-T/2"x13'- GLAZING MAY BE SHORT-PANEL (SHO1:'N) OR LONG-PANEL (NOT SHOWN), SEE SECTION :B-6 ON SHEET 2 FOR DETAILS. " . GLAZING MAY BE INSTALLED 1,14 TOP SECTION (SHOWN) 4R . INTERMEDIATE SECTION (NOT SHOWN)." -—Mr►A DOOR HEIGHT 0OF I: OF U-BARS i SECTIdNS _ UP TO 6'0' 3 a �.-, SEE END HINGE 6'3` TO 8'0` 4 1 5 1 1 VIEW B- � 8'3' TO 10'0" 5 6 B B 10'2' TO 12'0' 6 ? ----"� ------- -----.r>'- ---- 12'3' T❑ 14'0' 7 8 3 1"--" , ,�-----'-�1 !�'- , ,"'*------•�.. o o , ' 1' ,, I, II ', SEE NITCRMED. HINGE 14'3' TO 16'0', 8 9 1= 'i 1 I i i' i E i --�.--f' 1 VIEW C. 1 �' MAX'SECTION HEIGHT=2.' tO"� ii '1 1�_ ;, , J; !E- 0z `- __ --^-•'F-i-'^-"`^'^'"�'=i, SUDE BOLT LOCK o li__-____jl ri_______ii (i ,' , / iA Pi ENGAGES INTO END VERTICAL TRACK. __ 't i(„�___ ONE LOCK ON o� :_--'--"C'_i �--"-----� i_^---`_-- �-T-----_--: � INTO TRACK LOCKING _ DOOR. ----- .. EACH SIDE OF TMS BOOR MEETS OR AUILONG DE R THE EXCEEDS LOYN C.COIIL BUILDING CO ENCLOSED _______,' �i_______ I'—_____ ii I_____`I _ ' tNSiDf?LIDf. OLT UL71LWE WIND SPE-OS LISTED EELOV ACCORDING TO THE FLORIDA 6UNCD.iiG CODE OR THE NNT£RttATiONAt 6UtLDlNG COD_(BASED ON � 1, , i , , , r , _! I 1 , SNAP TCN ENGAGES L�CI< 0,'T1gy BUILDING, 2)DOOR HAS 2'OF MOTH 1:N BUILDING'S END ZONE.3) 1� r 1„______ I I� , !,, I L` J .;.-=�C.'=--t-------_-_ ONTO VERTNCAL TRACK. END ANY ROOF SLOPE,AND 4}TESTING 1N ACCORDANCE WITH --- - - —---- STILE. ANSVDASUA 106.SITE-SPECIFIC CALCULATIONS BY A QUALIFIED ONE SNAP LATCH ON j DESIGN PROFESSIONAL CLAY DIFFER. EACH SIDE OF DOOR. E3 ULTIMATE OUTSIDE KEYED ULTIMATE VIND LOCK POSITION SPEED(PPH) 155 160 t70 I80 195 B OUTSIDE MAX. DOOR WIDTH 9'-0" ! - .,.� HANDLE. LOCK BAR EXPOSURE D.C.D B,C.D D,C &C ,B E END ENGAGES IN c»TEGDRr _ — SHORT.PANEL SHOWN 4USCEtiOD-�•" i TRACK ON t STILE, i.EAti ROOF tvI0N7 23 75i 25' IY 30' � HANDLE. �� EACH SIDE INSIDE HANDLE OF DOOR. 0.115 E_KEYYED LOCK 171 OUTSIDE KEYED LOC' NOT SNAP LATCH LCCK OPTiOJ_J. LOCK BAR LOCKIN. i f 63 #14x5/8" SHEET MANUFACTURING PRODUCT CODE �<�.'• �^'' G METAL SCREWS {�� � DSIt;—IF47I -O• 1L Z4 F,fr,• Qm DESIGN LOADS: -�c P.S.F..:a 4.0 P.S,F r�h,RT NO.: NIA ^9•: STATE F .Ut: 1/4"x3/a" SELF TEV^1LOADSt +57.0 S.F.. -6G .O_PS. l AR C3' 2tJ" TAPPING SCREWS Sln,xa 0^�c..,xe �'f 6585 D,­ OHcBoule—d45D40 USA NaVVcI'NDLOA'{D�RATIpp r` 0o TOLERANCES o.� > � .W J DP3O 11.Na SLI-710-:°.L'Ofl4j'` -0 = .z.0�7 ".1r-:T:C.»b G:np:rg Fox Y.o.5:.-70-Ad57 � `. .00 = t.015 DESCRIPTION: GALLERY 2"FUR SINGLE CAR +38/-44 PSF t4 GA ENO NNNUS L__.A IL1T09ECIIAT IjINI�_F, 000 DRAWN 005 SY; MW DATE: 4I?f95 SCALE: VI�,W .0000 6.00E R DESIGN ENGINEER: �LE1I,"B« -C- Ccgrccs I1/2- _CHECKED BY: --- DATE: -- SHEET t OF SIZE L SCOTT HAMILTON, P.E. UM-3 S!_1c0 xncrM1lu FLORIDA I ENS N . 63286 0"�INSIONS ARE IN INCHES.DWG. I:7,: 70.•.32 .-„f,y -- - VER: ISC 4 3 2 FLORBOQ PRODUCT APPROVAL 16540 I 43. Ar NOVELS SHORT LONG MODELS FLUSH GROOVED SHEC7+ REVISIONS CLTIPAY GD2SU, GR2SU �C, 112LU CLS3PAY CLAS$iC 9202, HDPC20 9205, HDPR2Q 2 OF `}' REV. NO. ZONE: PATE: ECN N0. APPVD: _ DESCRIPTION GALLERY HOLMES AR2SU 1 HOLi4ES CLASSIC 7202: 7205 OS - - - SEE REVISION HISTORY ON SHEET ONE. ARTISTRY DEAL ED2SU ED2LU IDEAL CL'ASSLC',,-:8202.'I".4F'•.fTBU 8205, NFR68U . D D 4 IMPACT—RESISTANT CONSTRUCTION: STANDARD ASSEMBLY CONSTRUCTION: SOLID DOORS (NO GLAZING) OR DOORS WITH OPTIONAL IMPACT—RESISTANT GLAZING ARE OPTIONAL OSB OR 1/8"ACYRLIC SITES AVAILABLE. OPTIONAL AC.4Y_!C GLAZING :S IMPACT—RESISTANT. OPTIONAL IMPACT RESISTANT ASSEMBLY CONSISTS OF ALUMINUM PLASKOLITE OPTIX OR LUCITE CP APPROVED CC2 PLASTIC IN ACCORDANCE 4717H IBC/FBC FRONT FRAME AND SABIC IP LEXAN 9034 (VERSIONS ALSO APPROVED: MRIO, 9030, 2606. 90318, 90316, 90317, 90311, 90314, 90355)OR BAYER MAKROLON GP (VERSIONS THE ENTIRE DOOR ASSEMBLY INSTALIED IN COMPLIANCE WITH THIS SECTION MEETS THE ALSO APPROVED. SL,AR, 15), APPROVED CCI PLASTICS IN ACCORDANCE WITH IBC/FBC WIND LOAD REQUIREMENTS OF THE Ft_O cIDA BUILDING CODE OR INTERNATIONAL BUILDING 2606 AND AN APPROVED CI PLASTIC IN ACCORDANCE WITH FBC 2612. CODE BUT IMES NOT MEET THE IMPACT RESISTANT REQUIREMENT FOR W;NDBORNE DEBRIS THE ENTIRE DOOR ASSEMBLY INSTALLED IN COMPLIANCE WITH THIS SECTION MEETS THE REGIONS (REF. CHAPTER 16 FBC/IBC). WIND LOAD REQU.'RELIENTS OF THE FLORIDA BUILDING CODE AND INTERNATIONAL BUILDING - CODE AND 1S LARGE—AND SMALL—MISSILE IMPACT RESISTANT. SECTION B—B (NON—;MPACT RESISTANT GLAZING OPT�0.N) C SECTION B—B LUe9PACT—RESISTANT GLAZING OPTION) I � 1 I FRONT FRAME WITH U.V. COATING ON OUTSIDE I SURFACE. NOTE THAT STANDARD FRAME IS INSULATED DOOR SECTION. NARROWER THAN IMPACT—RESISTANT FP4ME 1.25' DECORATIVE FACADE. ) ' n XT6,RIOR OF DOOR. 1 II � SELF—TAPPING SCREWS, II 7 II INTERIOR OF DOOR. / GLAZING7. l.. MOLDED INSIDE 1188x3/4`PAN HEAD SCREW) RETAINER. LITE RETAINER. (12)0-18 x 1/2' ALUMINUM FRAME.• B SELF TAPPING SCREWS. B 1/4"THICK POLYCARBONATE - U GLAZING. " IMPACT-RESISTANT ASSEMBLY DETAILS STANDARD ASSEMBLY DETAILS DRAVRNG t 04432-A DRAINING 104432•B �4itiFs rrrrr� ' O"(•( HAMA rrr G <T�rrr viOENS N � •"�.. '�.,,, I:IANUFACTURING PRODUCT CODE '0 // DESIGN LOADS: +35.0 P.S.F. 6: -44.0 PS.F. I DSiU-11-4i 1 A "9 STATE OF J1� TEST LOADS; +57.0 P.S.F. 2: -66.0 P.S.F. PART NO.: N/A +0- O !lj uNaas swc.nmr,::c 2 010pay fi;v5 puke 8o-;Im ra f, 1® ■i WINDLOAD RATING :ti�*�C TOLERANCES s a Tun.OH 45040 USA rr'SC .R\• C7.O _ tcL I:a.t'V s13-170-:800 W 0-46MO DP-8 - it 11. .,I'll %, .00= _." [DESCRIPTION GALLERY 2"5FUR7SINGLE CAR +38/-44 PSF .DOD - =.005 DESIGN ENGINEER: DoOa= z,o01 DRAWN EtY: L;e1 _ DATE: 9/7/95 FSCALE: w7s plgG R SCOTT HAMILTON, P.E. (•c Orce9 t 1/2' CHECKED BY: -- I DATE: -- _ ET 2 OF 4 SIZE .L� 1Nlf smug E ORIDA LICENSE No-63286 Dn•Enso»3 aaE»i Inrri£S DWG. NO.: 10x432 — Af6 � : IBC 4 3 FUoRODA PROODUM APPROVAL 16546 4 ! 3 _41 2 t MODELS SHORT LONG MODELS FLUSH GROOVE➢ sr+EEi:A� _ REVISONSCLUPAY _ CID2SU, G,R2SU GD2tU, G.R2LU CLOPAY CLASSIC 92D2. HDPC20 9205, HDPR20 REV, NO, ZONE: DATE: ECN NO_'AP-D: DESCRIPTION GALLERY - -�_^. HD N S ARM AR2LU HOLr.ES CLASSIC 7202 7205 OS I i S£'E REVtS10N HIS:ORy ON SHEET ONE. AR-TS T Y ------- ID AL - 2"THICK XPR SiONS £D2SU ED2LU IDEAL ClASS1C 8202,N:FC68U 8205" MFRbBU —SILICONE FILLED CHANNEL SEPARATES FRONT AND BACK SKIN OF ODOR 3"TALC 50 KSI U-BAR I 20 CA, GALV. STEEL. URETHANE CORE DENSITY 2.4 P.C.F. 3" VERTICAL JAMB ATTAGH�NT (WOOD FRA"£ Q,t;iLOtNG51; f-7/8" t� + 3/8"x3` LAG SCREWS (1-1/2" EMBED) ON 24" CENTERS. 1-1/8" O.D. WASHER REQUIRED. LAC,SCREWS MAY BE COUNTERSUNK (BUT NOT REQUIRED) TO PROVIDE A FLUSH MOUNTIE 3 SUFFACE. HORIZONTAL JAMBS DO NOT TRANSFER LOAD. r Nr�12 GA, GALV. STEEL TOP VERTICAL JAM8 ATTACHIAFNT fC-90 BLOCK OR 2 000 PGI IAIN CONCRETE M-111-V 27 GA. MINSTEEL GALVEXTERIOR ��� ROLLER BRACKET. EACH 3/8"x3"SLEEVE ANCHOR BOLTS (1-1/2" EMBED) ON 22"CENTERS (2,000 PSI MIN. , . OR SKIN BRACKET ATTACHED W/(4) CONCRETE). WASHERS INCLUDED WITH SLEEVE ANCHORS, WITH BAKED-ON PRIMER AND A #14x5/8` SHEET METAL OR BAKED-ON POLYESTER PAINTED TOP COAT, SCREWS. 1/4"x3`TAPCON SCREWS (1-1/2" EMBED) ON 19" CENTERS (2,000 PSI MIN. CONCRETE) I TONGUE AND GROOVE JOINTS. OR t0"CENTERS (C-90 BLOCK). i" O.D. WASHERS REQUIRED WITH TAPCONS_ +(I ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) TO PROVIDE A FLUSH MOUNTING 14 GA. GALV, STEEL ROLLER SURFACE. HORIZONTAL JAMBS DO P40T TRAN5FER LOAD HINGE. EACH FASTENED TO END OTHER JAMB CONFIG(RATIONS: REFER TO QASMA TOS-161.A LICENSED DESIGN STILES W/(4) ="14x5/8" SHEET �,� !FETAL SCREWS AND (4) ?/4"?;3f4" AN PROFESSIONAL MAY ALSO BE EMPLOYED TO APPROVE ALTERNATE FASTENERS AND/OR JAMB + SELF TAPPING SCREWS CONFIGURATIONS. PREPARATION OF JAMBS BY OTHERS )� 3`TALL x 2O CA, GALV. STEEL r NOTE: THE DESIGN OF THE SUPPORTING STRUCTURAL ELEMENTS SHALL U—BAR. ONE PER DOOR OF RECORD FOR THE BE THE RESPONSiBItiTY'Ofi THE PROFESSIONAL SECTION, EXCEPT TWO ON BUILDING OR STRUCTURE AND IN ACCORDANCE WITH CURRENT BUILDING- BOTTOM SECTION. ATTACHED CODES FOR THE LOADS LISTED ON THIS DRAWING. .. WITH (2) 1/4"x3/4" SELF TAPPING SCREWS AT EACH o HII4GE LOCATION. L? �. d 27 CA, STEEL GALV, HvER;OR.SKIN g r "�+ WITH A BAKED—ON PRIMER AND A BAKED—ON POLYESTER PAINTED TOP COAT. K j-- 13 CA, GALV. STEEL BOTTOM BRACKET. _ ATTACHED WITH (4) #14z5/8" SHEET METAL SCREWS. ALUMINUM EXTRUSfON & VINYL 'WEATHERSTRIP. HAIL)j�T���r' SE-,T}ON h_A (SIDE VIEW) g..��GENs�}��e *.' B 1IANurACTURING PRODUCT CODE DSIU-1F471 b» IvJ/7R lIT ,� DESIGN LOADS: -380 P.S.F. & -44,O P,S,F. H `91 ST .ATE OF \ �` TEST LOADS: +57,0 P.S.F: & -66.0_PS PART NO_: N/A i f1 1!/ LIT—stotea CNnc->. n} 8525 Duke 80u10 wd WINDLQAD RATING r« rZ a R,q.; [,'iopay ri`o.°si3`-770-45� D P 3 8 TOLERANCES a.e ....... p � ,, OG - s.ois DESCRIPTION: GALLERY 2` PUR7SINGLE CAR +38/-44 PSF 000 = .005 DESIGN ENGINEER= 0000- *R/2. DRAWN BY: MW DATE:9/7/95 SCALE: NTS DwG, 9 CHECKED BY: -- DATE: -- ISHEET 3 OF 4 ISIZE L SCOTT HAMILTON, P.E. U.'eas ssmca FLORIDA LICENSE No 63286 NENSIONS ARE IN u+aEs QVtG. NO.: 104432 — A/D VER: IBC 4 3 2 FLORODA PRODUCT�"PPROVAL 16646 i SHEET� ODELS SHORT LONG MODELS FLU—SH rIFrlcj\lcl) REVISIONS 'LOPAY 4 OF A, L.LERY GD2SIJ, GRZSU GD2LU, GR2LU CLOPAY CLASSIC 9-202. HDPC20 9205, HDPR20 DATE. ECN No, Ppvo: DESCRIPTION RTJ TRY ARM HOLMES CLASSIC 7202 7205 05 REVISION HISTORY ON SHEET ONE. QLMES C DPAY Y Ci�LD A� lFil�LE ERY I RY H LHES L ST"Y T"Y 2471 -I ID AL IDEAL CLASSIC 8202. W-C681.1 82D5, MFR68U XPR "NIS ED2SU ED2LU DI 2"TRACK Q014MURATION. DOOR COUNTERBA• LANCE SYSTIDA NFIGURATION. HORIZONTAL TRACK 13 CA GALV STEEL FLAG BRACKET ATTACHED TO DOOR SUPPORT BY DOOR JAMS WITH (3)5116-X 1-5/8-LAC SCRCwS IHEIGHT V INSTALLER(TO SUIT). AND TO TRACK WITH(2) 1/4-RiVEM * " 7 RATION, Ix 2.6 SYP WOOD JAMEL SEE EW-TRACK CONFIOU OPRONAL STOP MOULDING BY INSTALLER(To SUIT). "JA&IB PREPARATION NOTE-- STEEL END STILE ABOVE THE DOOR OPENING GOES: 85, AS ROD:SPACING HIS 30'O.C. '-D /-Ill CA NOT AFFECT THE WIND LOAD RATING OF THIS DOOR, 62-t4" 2*CAM STEEL TRACK, 0" TRACK THICKNESS:0.681-. 2-1/2"X 12 CA CAM STEEL� to'- 119, TRACK 9Rl-'NETS FASTENED TOWOOD JAMBS Villi,5/6-X 1-5/3- ROUND 7/16-?.D. is GA. M14 STEEL CZNTER HINGE It- 1 4- LAC SCREWS. PUSH N6T FASTENED TO SECTION-01(4) EACH FASTENER. 0-518'SHEET METAL SCREW- 36-±2" -2-1/2-X 12 CA CALM. I --a 13 STPEL TRACK BRACKETS, 1 --6142' 14 GA. GALV. SIMI-ROLLER HINGES FASTENED TO ENO D STILES W/1[4) EACH '14.5/8" ATTACHED TO JAJ45 WITH (1) SHEET METAL SCm,.,-,AND(2) 114'SELF 7�*,PPINa-SCREWS PER END HINGE. 5/16-X 1-5/6-LAG SCREW PER 2'CALM,STEEL TRACK FASTENED I TRACK BRACKET. 12 CA GALV STEEL TRACK BRACKETS WITH EITHER (2) 1/4"OLk RIVETS OR 2'DIA SHORT STEM 10 l3ki, STEEL ROLLER WITH S-EEL OR NYLON TIRE. 10" (1) 1/4-X 5/8-BOLT&NUT PER 3-1/2, 15. TRACK BRACKET. PREPARATION OF-*JABA--RY QjBWS, LHR BRACKET(2-1/2".5-3/4'. 12GA) ATTACHED WITH (2) 1/4'.3/4-SELF TAPPING 3-TRACK IS ALSO&YLILA%g S--is. tsr Lo"91,LLR-Ap"A.OX-H.7�1.OPTION (AVAIL, FOR BOTH 2-AND 3-TRACK) 'DOUBLE HORIZONTAL TRACK. oHA4jj4,l,, ........ 3 8 MANUFACTURING PRODUCT CODE DSIU-IF471 DESIGN LOADS: 38.0 P.S.F. & -44.0 P-S.F. STATE: OF T�LOAQS: +57.0 S.F, & -66.0 P.S.F. - PART NO.: N/A vmess st-d OILI-ile 8585 Dk�eMnUoUd WINDLOAD RATING Of.4504 TOLERANCES 111113"y 513-778-4 653 F.N.513-770-4653 W6 DP38 %% ca z.015 DESCRIPTION: GALLERY 2'SPUR SINGLE CAR +38/-44 PSF I.......Its" .000 ..005 NTS E Deg— 1/2' CHECKED BY: -- ATE: -- SHEET 4 OF 4 siz DESIGN ENGINEER: ODOD tZol RRAW!�BY, MW DATE: 9/7/95 1 SCALE: NT Dl%l SCOTT HAMILTON, P.E.I01--l' - -FLORIQA LICENSE No. 63286 ot.mEasIons ARE:N"cHEs DING. NO.: 104432 AIB VER: :BC 2 FL OREDA PROD T APPROVAL TS348o