Loading...
HomeMy WebLinkAboutDesign pressure calcs 801 License STORM 4047 Okeechobee Blvd,Ste 106, SMART West Palm Beach, 33409 Phone 561)229-00404 8 www.StormsmartSE.com of Southeast Florida Property Information Building Information Owner: William Rossy' Wind Zone: 160 MPH. Address: 8024 Links Way Exposure Category: C Port Saint Lucie,FL 34986 Minimum Building Dimension: 2 ft. Mean Roof Height: 23 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) IF Elevation(ft) Pressure(psf) Pressure(psf) 2 Int 272.25 138 11.5 28.9 -32.0 3 Int 36.25 138 11.5 33.1 -36.2 4 Int 58.25 138 11.5 32.5 -35.6 i Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 I