Loading...
HomeMy WebLinkAboutProduct Approval 11/1/2019 Florida Building Code Online i nrA i lly7f��a ! 16 l��'t �.eL,_.7N�QI�S`'`tJ � �. 1�11P ion ti (• M1i i� I� rte, it !t,.�ej7 BCIS Home I Log In �I User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us I BCIS Site Map Links I Search Florida uo p f rProduct Approval ( � - USER:Public User Product Approval Menu>Product or Aoplication Search>Appllcatipn Llst>Application Detail ,`ECE-1 y er) + FL# EC20378-R1 ,3 FEB 2 4 2020 Application Type Revision Code Version 2017 ST. Lucie Colin Application Status Approved tyr Permitting Comments Archived Product Manufacturer ,Extreme Metal.Fabricators, LLC FILE Copy Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772) 872-8034 e?-,90 Z ^ 06'8 fivalidation@yahoo.com Authorized Signature Richard McKuhen REVIEWED FOR fivalidation@yahoo.co ®®E COMPLIANCE Technical Representative Richard McKuhen VA�. ���'E �®6.JN��� Address/Phone/Email 2160 SW Poma DriveST. Palm , FL (772)8172 80 34 990 BOCC richard@emfab.net Quality Assurance Representative ^ 8n sLD Address/Phone/Email Category Roofing Subcategory Metal.Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. ' Validation Checklist-Hardcopy Received Certificate of Independence FL20378 R1 COI FL 20378.1 NAILSTRIP 1.0 .032 ALUM sss.pdf Referenced Standard and Year(of Standard) Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquap/o2flMZ8n5CNV4ZYkew5Zoap/p2fEp/o2fovztglbhDVU2dJO4TAAp/o3d%3d 1/3 11/1/2019 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated '12/18/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/19/2017 Summary of Products FL# Model,Plumber or Name Description 20378.1 01 -"1"Nailstrip" 0.032"Aluminum Standing Seam roof panel, 12"wide, mechanically attached to 15/32"plywood or Wood Deck with fasteners. Limits of Use Installation Instructions Approved for use In HVHZ: No FL20378 R1 II FL 20378.1 NAILSTRIP 1.0 .032 Approved for use outside HVHZ:Yes ALUM sss.pdf Impact Resistant: No Verified By: Locke Bowdenf P.E.49704 Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes Other:Refer to evaluation report for Limitations and Evaluation Reports _ Conditions of Use. Refer to manufacturer's installation FL20378 RI AE FL 20378.1 NAILSTRIP 1.0 .032 Instructions. ALUM sss.pdf Created by Independent Third Party: Yes 20378.2 02-"1" Nailstrip" 26-gauge Steel Standing Seam roof panel, 16"wide, mechanically attached to 15/32"plywood or Wood Deck with fasteners and adhesive. Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378 R1 II FL 20378.2 Extreme Metal Fabricators 26GA Approved for use outside HVHZ:Yes NAIL STRIP 1.O.pdf Impact Resistant: No Verified By: Locke Bowden, P.E.49704 Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes Other:Refer to evaluation report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's installation FL20378 R1 AE FL 20378.2 Extreme Metal Fabricators 26GA Instructions. NAIL STRIP 1.0.pdf Created by Independent Third Party: Yes 20378.3 03-"1.75 Snap Lock" 0.032"Aluminum Standing Seam roof panel, 18"wide, mechanically attached to 15/32" plywood or Wood Deck with panel clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378 R1 II FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-Table A Evaluation Reports Other: Refer to evaluation report for Limitations and FL20378 RI AE FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf Conditions of Use. Refer to manufacturer's Installation Created by Independent Third Party: Yes instructions. 20378.4 04- "1.75"Snap Lock" 24-gauge Steel Standing Seam roof panel, 18"wide, mechanically attached to 15/32"plywood or Wood Deck with panel clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378 Ri II FL 20378.4 1.75 SNAP LOCK 24GA-ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for Limitations and FL20378 RI AE FL 20378.4 1.75 SNAP LOCK 24GA-ssr.pdf Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 20378.5 05- "Rib Panel' 29-gauge Steel exposed fastener roof panel,36"wide, mechanically attached to 15/32"plywood or Wood Deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378 R1 II FL 20378.5 RIB 29GA ssrpd Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E.49704 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for Limitations and FL20378 R1 AE FL 20378.5 RIB 29GA ssr.pdf Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes Instructions. 20378.6 06-"5V Crimp" - 26-gauge Steel exposed fastener-roof panel,24"wide, https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5ZOa%2fE%2fovztglbhDVU2dJO4TAA%3d%3d 2/3 11/1/2019 Florida Building Code Online mechanically attached to 15/32" Plywood or Wood Deck w/fasteners. TAMKO BUILDING PRODUCTS � � Installation Instructions Asphalt Shingles _ I .t tftffl 9pe0GMWP1d :ENPLC FL20378 RI II FL 20378.6 5V Crimp sss,pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden, RE.49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/4/-Table A Evaluation Reports Other: Refer to evaluation report for Method 1 and Method 2 FL20378 RI AE FL 20378.6 5V Crimp sss.pdf fastening, Limitations and Conditions of Use. Refer to Created by Independent Third Party: Yes manufacturer's installation instructions. 20378.3 07-"1.5 Standing Seam" 24-gauge Steel Standing Seam roof panel, 16"wide, mechanically attached to 15/32"plywood or Wood Deck with panel clips,fasteners and adhesive Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378 R1 II FL 20378.7 JM STANDING SEAM ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E.49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure:+N/A/-Table A Evaluation Reports Other: Refer to evaluation report for Limitations and FL20378 R1 AE FL 20378.7 JM STANDING SEAM ssr.pdf Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions, 20378.8 08-"Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to 15/32"plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378 R1 II FL 20378.8 NORDMAN TILE 24GA ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-Table A Evaluation Reports Other: Refer to evaluation report for Limitations and FL20378 RI AE FL 20378,8 NORDMAN TILE 24GA ssr.pdf Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes Instructions. 20378.9 09-"Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to Steel Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378 RI II FL 20378.9 Nordman Tile Details-ssr.pdf Approved for use outside HVHZ:Yes Verified By:James L. Buckner, P.E. @ CBUCK Engineering P.E. Impact Resistant: No #31242 Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes Other; Refer to evaluation report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's installation FL20378 P1 AE FL 20378.9 Nordman Tile Details-ssr.pdf instructions, Created by Independent Third Party:Yes 20378.10 10-"Nordman Tile" 0.032"Aluminum metal roof tile panel mechanically attached to 15/32"plywood or Wood Deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL20378 RI II FL 20378.10 NORD TILT.032 ALUM-ssr.pdf Approved for use outside HVHZ-Yes Verified By: Locke Bowden, RE,49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-Table A Evaluation Reports Other: Refer to evaluation report for Limitations and FL20378 R1 AE FL 20378.10 NORD TILT.032 ALUM-ssr.pdf Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 0 Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer,Copyrlght 2007-2013 State of Florida.::Privacy Statement::Accessibility.Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: NA E FE; E Credit Card Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqua%2flMZ8n5CNV4ZYkewSZoa%2fE%2fovztglbhDVU2dJ04TAA%3d%3d 3/3 2160 SW Poma Drive Palm City, FL 34990 772) 872-8034 Compliant with Florida'Building Code 2017 (01 ed.) Compliant with Florida Product Approval Rule #61G20-3 Compliant : Keystone Certifications Product: 5 V Crimp 26GA Metal Roofing Panel Corrosion Resistant FBC Sec. 1507.4.3 Yield strength:40ksi Steel Attached to min. 15/32" plywood or Wood Deck w/ min. Attached 24" 0.42 specific gravity with screws. 24" Coverage Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec. 1506, 1507 Fastener for Method 1 Attachment#9-15 x 1"Hex Head w/EPDM Bonded Steel Washer to penetrate 3/16"thru wood decking Fastener for Method 2 Attachment #9-15 x 1"Hex Head w/EPDM Bonded Steel Washer to penetrate 3/16"thru 15/32"min. plywood deck or 5/8" into wood plank Underlayment: To be compliant with FBC Sec.1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. ,. Instal l Details:.Table A Allowable ble_ Loads METHOD 1 METHOD 2' i AVENER PLAcEMENT _. - _. i... DESIGN PRESSURE* ._ -85 PSF 114.25 PSF METHOD 1 IN RIB PEAKS .ROW SPACING � : .._._-� .,_-...._:. ----_ - — 12"O.C. 12"O.C. METHOD 2 IN PANEL FLATS FASTENER SPACING j 12" O.C. 12"O.C. 'SEE INSTALL DRAWINGS FASTENER SIZE: #9 #9 *ALLOWABLE DESIGN PRESSURE MARGIN OF 2 T0.1 i Reference Data: HURRICANE TEST LAB#TST ID: 1527 TAS 125-03 Test#0223-0307-01;METHOD 1 (UL 1897-04') TAS-125-03 Test#0223-0517-06,METHOD 2 i t EQUIVALENCY UL 1897.04 IS EQUIVALENT TO UL 1897-12 TEST STANDARD * DESIGN PRESSURE SAFETY MARIGIN 2:1 t Certificate of Independence: Locke Bowden,P:E,does not have,not will acquire a financial interest in any company manufacturing or distributing products under this evaluation. ,�s�t IITIrIf pp Locke Bowden,P.E.is not owned,operated,or controlled by any company,manufacturer,or distribuNgg I"-1 fs`... , of. report. . e q ' [�.• '7v, .p` "' l+" ` .req `st �aj3�j�u�Y It "'a ''-,r• :d:afh� ' , ° ^ Compliance Statement: These products.herein evaluated have demonstrated compliance with the Florida Building Code 2017 ` 6th ed,with referenced documents submitted. Limitations: 1. Underlayment to be compliance with current Florida Building Code 2017 61h ed.,Section 1507.1.1 Z. Products are compliant for State of Florida product approval per Rule 61G20-3 3. Compliance Method: 1'D 4. Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. S. All support framing compliant w/Florida Building Code 2017,Chapters 22 for Steel,23 for Wood and 16 for Structural Loading.Design of support and attachment to the framing is outside the scope of this evaluation. 6. Rule'61G20-3 allows for engineering analysis by registered/licensed others for"project specific approval" by local authorities,authorized 6ythe code,and|sthe responsibility nfothers. 7. This report does not imply warranty,installation,recommended product use outside of this report. Fo�ww�' fl � ' ----- 15�z Rynmum plank Fasteners- 6V-Crimp" Roof Panel EPO&I Bonded Steel V%lashers, '------ if XL 61 . ..._Deck: -15-3Z' Pl)nvmod.,m '. cwwplank