HomeMy WebLinkAboutWind Load Calculation Advanced Architecture & Planning LLC
Architect & Planning
4929 S. Indian River Drive
Ft. Pierce, FL 34982 (772)631-5709
Applied Wind Pressures Certification:
February 11,2020
Bill Laprade -
Glass Professionals FEB 2020
Stuart,Florida. Cell: 772-745-3459
Email: glassprofessionals@gmail.com ST. Lucie County., Permitting
Project: Atlantis III By the Sea
Unit 204(2nd Floor)
10200 S Ocean Dr, Jensen Beach,FL 34957
Dear Mr. Laprade:
This Unit 204 is not an end unit and falls within wind loading based on Zone 4,Exposure D.
Completing the wind load calculations based on the Residential FBC 2017,the applied wind pressures are as
follows per the proposed replacement glazed units:
Glazed Unit: _Applied Wind Pressure:
(3) CGI, 27"x63"single hung windows: +47.8/-50.7 psf each
(2) CGI, 37"x39"single hung window: +47.9/-50.9 psf
(1) CGI, 37"x39" single hung window: +47.9/-50.9 psf
(1) CGI, 60"x80"sliding glass door: +44.4/-48.0 psf
(1)CGI, 107"x80"sliding glass door: +42.9/-46.2 psf
It is understood the glazed units to be installed must have a design pressure equal to or exceeding these
respective applied pressures.
If you have any questions,please contact me at any time.
Thank you,
y'='sj
le copy
i >
Raymond Chladny, B.arch.Sc.,M.arch,
AIA, NCARB, Lic.#: AR-0017475