Loading...
HomeMy WebLinkAboutWind Load Calculation Advanced Architecture & Planning LLC Architect & Planning 4929 S. Indian River Drive Ft. Pierce, FL 34982 (772)631-5709 Applied Wind Pressures Certification: February 11,2020 Bill Laprade - Glass Professionals FEB 2020 Stuart,Florida. Cell: 772-745-3459 Email: glassprofessionals@gmail.com ST. Lucie County., Permitting Project: Atlantis III By the Sea Unit 204(2nd Floor) 10200 S Ocean Dr, Jensen Beach,FL 34957 Dear Mr. Laprade: This Unit 204 is not an end unit and falls within wind loading based on Zone 4,Exposure D. Completing the wind load calculations based on the Residential FBC 2017,the applied wind pressures are as follows per the proposed replacement glazed units: Glazed Unit: _Applied Wind Pressure: (3) CGI, 27"x63"single hung windows: +47.8/-50.7 psf each (2) CGI, 37"x39"single hung window: +47.9/-50.9 psf (1) CGI, 37"x39" single hung window: +47.9/-50.9 psf (1) CGI, 60"x80"sliding glass door: +44.4/-48.0 psf (1)CGI, 107"x80"sliding glass door: +42.9/-46.2 psf It is understood the glazed units to be installed must have a design pressure equal to or exceeding these respective applied pressures. If you have any questions,please contact me at any time. Thank you, y'='sj le copy i > Raymond Chladny, B.arch.Sc.,M.arch, AIA, NCARB, Lic.#: AR-0017475