HomeMy WebLinkAboutProduct Approval (2) 1/2/2020 Florida Building Code Online
` I xp
? t t 11 ` i, ��:r f�.rr.�[:.�...-'tii.=:+�• •-- •,-T-T• n .-'r.alir
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats:.Facts PubppRns %ntact;s SCIS Site I•lap Lintas Search
)Product Approval 3 ro m
USER:Public User ® p
T
Prcdurt AQPrnval Menu>Product nr A�plica[inn Scarth>ApRlicatinn List>Application Detail
FL tFL2569-R17
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Soprema,Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON-US 00000
(819)478-2400
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1638 lean-Berchmans-Michaud
Drummondville, NON-US 00000
(819)473-2400 Ext 3327
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/13/2020
Validated By John W. Knezevich, PE
Validation Checklist-Hardcopy Received
Certificate of Independence FI-2569 R17 COI 2019 W COI NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 '015
ASTM D4798 2011
ASTM D6163 2Q08
FM 4474 2011
FRSs./TRI April 2012(04-12) 2012
UL 1897 2012
lie Copy
hilps://fioridabLiliditiq.orq/pr/pr ann dtl.asr)x?D^aram=wGEVXOt-.1riotKOFPnckh'lnRFrv711ri?vVlrlimFrlNntRfdrW1417r7rmto•!)kAo/:,tc•/v,a .,,
1/2/2020 Florida Building Code Online
Equivalence of Product Standards
Certified By
-'1
Sections from the Code
Product Approval Method Method i Option D
Date Submitted 08/14/2019
Date Validated 08/14/2019
Date Pending FBC Approval 08/17/2019
Date Approved 10/15/2019
summary of Products
_,__._...._.__....... - - - -._.......- —--................ _.. _.__........ _. _......... .....
FL# i Model,Number or Name Description
!2569.1 Soprema Roof Underlayments Self adhering roof underlayments
Limits of Use ;Installation Instructions
Approved for use in HVH2:No X2569 R17 II 2019 06 FINAL ER FL2569-R17 pdf
Approved for use outside HVHZ:Yes Verified By: Robert Nieminen,P.E.PE-59166
Impact Resistant:N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-150 'Evaluation Reports
Other:1.)Refer to ER Section 5 for Limits of Use. 2.)The FL2569 R17 AE 2019 06 FINAL ER FL7569-P17 pdf
design pressure noted herein pertains to underlayment systems Created by Independent Third Party: Yes
used beneath adhesive-set tile systems. Refer to ER Section ;
5.6.4 for details.
Contact us::25ui glair stone Road,Ttllahas ee F ? Phone:850-487-1:324
="r
The State of Florida is an AA/EEO employees Copyright 2007-2013 State of Florida.::Priv cy Statement::Accessibilit;•Statement::Refund Statement
Under Florida lair,email addresses are public records.it you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section•155.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter•155,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please cud:hem.
Product Approval Accepts:
rt rrr+
GreClll Card
Safe
htips:Hfloridabuildiiig.org/pr/pr_app_dti.aspx?paraln=wGEVXQwtDasKQFEnckBIORErxlllrl3xYlriiltt5r'rHmR(lirHH17r7rn�t4!?hneio
MEMO I etc.
Certificate of Authorizotion#32455
353 Christian Street, Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
man
Soprema,Inc. Evaluation Report S18010.06.09-RiS
1640 rue Haggerty FL2569-1317
Drummondville,Quebec J2C 5P8 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 15:06/19/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products
described herein have been evaluated for compliance with the 61th Edition(2017) Florida Building Code sections noted
herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
xt
i�
Robert J.M.Nieminen,P.E. s+��- The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 `" ;_Lk; Nieminen,P.E.an 05/19/2019.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. MEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMOI etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project
on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically
for that purpose.
n
N
MEMO etc.
ROOFING COMPONENT EVALUATION:
tj. SCOPE'
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the 6t°Edition(2017) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.1.1,1507.2.9.2,R905.1.1, Physical Properties ASTM D1970 2015
R905.2.8.2
1507.3.3,R905.3.3 Physical Properties FRSA/TRI April 2012 2012
FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008
TAS 110 Accelerated Weathering ASTM D4798 2011
a
Entity Examination Reference Date
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) ASTM D1970/TAS 110(QC) 531370.03.10-1-R1 04/07/2010
ERD(TST6049) FRSA/TRI 04-12(OH) 511150.05.09-112 10/05/2010
ERD(TST6049) ASTM D1970(OH) 537210.11.11 11/09/2011
ERD(TST6049) ASTM D1970(IVIS) 537210.12.11 12/01/2011
ERD(TST6049) ASTM D1970(M5) 540540.02.13-1 02/19/2013
ERD(TST6049) FRSA/TRI 04-12(MS) 543530.02.14-1-R1 02/21/2014
ERD(TST6049) ASTM D1970(BC) 544870.04.14-2 04/02/2014
ERD(TST6049) ASTM D1970(QC) 544870.04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 04/10/2014
ERD(TST6049) ASTM D1970(MS) 544870.04.14-4 04/10/2014
ERD(TST6049) ASTM D1970(OH) S40540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-R1 04/25/2018
NEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO(TST6049) ASTM D4798/D1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019
PRI(TST5878) ASTM D1970(IVIS) SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 07/18/2017
NEMO ETC,LLC Evaluation Report 518010.06.09-R15
Certificate oJAurhorirorion"32455 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-1117
Soprema Roof Underlayments Revision 15:06/19/2019
Page 2 of
NNEMO etc.
4.. PRODUCT DESCRIPTION:
Product Specification Plant(s) Description
4.1 Lastobohd TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric surfaced,
FRSA/TRI April 2012 SBS modified bitumen roof underlayment
4,2 Lastobond Shield ASTM D1970 " Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.3 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
40 modified bitumen roof underlayment
4.4 Lastobond Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.5 Lastobond Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.6 Lastobond Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4,7 EnviroShield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.E Lastobond 195I ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-surfaced,
Wadsworth,OH SBS modified bitumen roof underlayment
4.9 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-surfaced,
Protection Sheet Wadsworth,OH SBS modified bitumen roof underlayment
4.10 Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH
4.11 Lastobond Smooth SealI ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,
HT Wadsworth,OH SBS modified bitumen roof underlayment
4.12 PrimeSource Grip-Rite ASTM D1970 Gulfport,FAS self-adhering,glass-mat reinforced,film-surfaced,
Smooth Seal HT Wadsworth,OH SBS modified bitumen roof underlayment
4.13 RESISTO L61236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Gulfport,MS SBS modified bitumen roof underlayment
t Wadsworth,OH
4.14 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Eave&Valley Protector Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH
4.15 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH
4.16 Colphene FR GR ASTM D1970 and I Gulfport,rvlS self-adhering,fiberglass reinforced,granule-
FRSA/TRI April 2012 Wadsworth,OH surfaced,SBS modified bitumen roof underlayment
WON
5.1 This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E.are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
MEMO ETC,LLC Evaluation Report 518010.06.09-R15
Ceni/icote of Authotho(ion,132455 6"EDITION(2017)FOC NOP:-h!VHZ EVALUATION F,2569-RI7
Soprema Roof Underlayrnents Revision 15:06/19/2019
Page 3 ol8
ONEMO i etc.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request maybe made to the Authority Having Jurisdiction for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
'TAOLE Iv RcioF'COVER,6pTio
Wood or Slate or
Underlayment Asphalt Nail-On Foam-On Metal Composite I
Y Shingles I Tile Tile I Shakes& Composite
Shingles Slate
Lastobond TU HT Yes Yes Yes Yes Yes Yes
See 5.5.1
Lastobond Shield/Pro HT-N/ Yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
EnviroShield Yes No No Yes Yes Yes
Lastobond Eaves Protection Sheet/
Lastobond 195 Yes No No No Yes Yes I
Lastobond ECO /RESISTO LB1236,
Grip-Rite Eave&Valley Protector/ Yes No No No Yes Yes
RESISTO LB1244
Lastobond Smooth Seal HT/Grip-
Rite Smooth Seal FIT Yes No No Yes Yes Yes
Colphene FR GR Yes Yes I No No Yes Yes
5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations.
Underlayment Adhesive Florida Product Approval
Dow TileBond'"' FL22525
Lastobond TU HT
ICP Adhesives Polyset"AH-160 FL6332
5.6 Allowable Substrates:
Underlayment Primer Substrates
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA (Optional)ASTM D41,
SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S, Elastocol Stick,Elastocol Stick plywood,058,Southern fellow
EnviroShield,Lastobond TU HT,Lastobond Eaves Protection Zero Pine(SYP)
Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236,
Grip-Rite Eave&Valley Protector,RESISTO LB1244, ASTM D41 structural concrete
Lastobond Smooth Seal HT or Grip-Rite Smooth Seal HT
Colphene FR GR (Optional)ASTM D41 Plywood
ASTM D41 structural concrete
Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report 518010.06.09-RIS
Certi/itnteo/Authorimtion x32455 6'"EDITION 12.0171 FF3C NON-HVHZ EVALUATION FL2569-Ri.7
Soprema Roof Underlayments Revision 15:06/19/2019
Page 4 of 8
ONEW10 I etc.
Underlayment Primer Substrates
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA
SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S, Dens Deck Prime;SECUROCK
EnviroShield,Lastobond TU HT,Lastobond Eaves Protection Gypsum-Fiber Roof Board;
Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236, (Optional)Elastocol Stick Zero ASTM D226,Type I or II felt;
Grip-Rite Eave&Valley Protector,RESISTO LB1244, Sopra-G-'Modified Sopra-G
Lastobond Smooth Seal HT,Grip-Rite Smooth Seal HT or
Colphene FR GR
5.6.1 Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for
installation within 24 hours.
5.6.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment
5.6.3 For installation under mechanically attached prepared roof coverings,insulation or coverboard shall be attached
per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems(Lastobond TU HT only), insulation attachment shall be designed by a qualified design
professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,
Appendix D,Testing Application Standard TAS 114,Appendix J or UL1897.
5.6.4 For installations under mechanically attached prepared roof coverings,base sheet shall be attached per minimum
codified requirements. For installations under foam-on tile systems(Lastobond TU HT only), base sheet shall be
attached in accordance with FRSA/TRI April 2012(04-12)or Section 5.6.5 herein.
5.6.5 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12) and are used in foam-on tile applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI
April 2012(04-12)or FBC 1609 for determination of design wind pressures.
#I Maximum Design Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
N2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
NErti70 ETC,LLC Evaluation Report 538010.06.09-1115
Certificate of Authoriratioa x'32455 "'EDITION(2017)Ff3C NOIJ-HVHZ EVALUATION EL 2569-RI7
Soprema Roof Underlayments Revision 15:06/19/2019
Page 5 of 8
ONEA110 I etc.
#3 Maximum Design Pressure=-120.0 psf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of
Authority Having Jurisdiction.
Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered;thoroughly rolled using hand roller and/or weighted
roller in accordance with Soprema requirements to ensure no voids no bridging at side and end-
laps.
Underlayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
#4 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCY, plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
#5 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC
1517.5.2)spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c.in three(3),equally spaced rows
in the center of the sheet.
Underlayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps
5.6.5.1 All other direct-deck, adhered Soprema underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf.
5.6.5.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table IA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case,Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies
marked with an asterisk'carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29
(January 2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO L61236, Grip-Rite Eave & Valley
Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond Smooth Seal HT or Grip-Rite Smooth Seal HT shall not be left exposed for longer than 90-
days after installation.
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
N'EN10 ETC,LLC Evaluation Report s18010.06.o9-R15
Certificnre of Authorization x32455 5"'EDITION(20171 FE+C NON-HV'HZ EVALUATION F1.2569-R17
Soprema Roof Underlayrnents Revision 15.06/19/2019
Page 6 of 8
ONEMO I eic.
5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)):
When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
r a• t t
Maximum
Underlayment Tile Profile T
Staging Method Slope
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack shall be inverted, I
followed by 8 tiles high on slope,as shown below) 6:12
Lastobond TU HT
Lugged
s
Colphene FR GR Flat Max.10-tile stack 5:12
Lugged Max.10-tile stack 6:12
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate with Elastocol Stick,Elastocol Stick Zero or RESISTO
EXTERIOR PRIMER(if applicable).
6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S,EnviroShield,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,Lastobond
Smooth Seal HT,Grip-Rite Smooth Seal HT, RESISTO LB3236,Grip-Rite Eave&Valley Protector, RESISTO LB1244
or Colphene FR GR:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 or
R905.1.1 for the type of prepared roof covering to be installed,and Soprema published requirements.
6.3.2 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self-Adhered Membrane, and Soprema
published requirements.
For mechanically fastened the roofing over a 2-ply systern,consisting of Base Sheet and Self-Adhered Membrane,
fastening of the ASTM D226,Type II base sheet shall be in accordance with Soprema requirements,but not less than
that the densities set forth in FRSA/TRI April 2012(04-12),Table 1.
For foam-on tile applications(Lastobond TU HT only),reference is made to Section 5.6.5 herein for wind resistance
limitations that fall outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and staged in a manner,that prevents tile slippage and/or damage to the underlayment. See
Table 3 herein,and Soprema published requirernents for tile staging.
NEIVIO ETC,LLC Evaluation Report S18010-06.09-R15
CertijicoreofAuthorization 1;32455 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FL2559-RI7
Soprerna Roof Underlayments Revision 15:06/19/2019
Page 7 of 8
NEM01 etc.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
Refer to Section 4 herein for product&production locations having met codified physical properties specifications.
79. QOALITY' AssLiRACEENfiTY:
UL,LLC—QUAMS;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 618010.06.09-R15
Certificate ciAuthorizotion#32455 611'EDITION(7.017)F13C NON-HVHZ EVALUATION FL2569-R17
Soprema Roof Underlayments Revision 15:06/19/2019
Page 8 of 8