Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutInspection Docs II
FAMILYROOM
{�I
I
®'192 cb
-
- r 11'Chim'
CLOST
447 dm f
�j OFFICE - KITCHEJdIDINING BEDROOM2 4�
Y 131efrti 5cft. }9,210cfin
1711 2l.wo
71 131cim ! x
j. 811
HALL �- C S
7" 12x12x1
[0v334cfm 6�„ `'^-
ENTRY BEDROOM BATH"�
IE GARAGE 101,0H
.f
y ,
Job#: Scale 1 112
eed. QUICK CALLS,INC.
FvOb 1
CORYIELLY 317ST LUCIELANE: Righ#SuWUnkersa12019
I 75PBPENSACOLAROAD FORT PIERCE FL;34946 1.9DD7RSU08101
FT.PI RCE,FU46 1 IPhone:77c_FI-6799. 2024-Fc�261811327
-W
rig aOAOL.COMrohtsaBHVAdV<ELIY,CORY.ryp
Project Summary J e:
- - wrightsoft® Entire House By.
QUICK CALCS, INC.
317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phom:772-466-6799 Email:QUICKCALCS@AOL.COM
Project • •
For. - CORY KELLY
7508 PENSACOLA ROAD,FT.PIERCE,�FI-34951
Notes:
Design Information
Weather: Fort Pierce,FL,US
Winter Design Conditions i Summer Design Conditions
Outside db 42 °F Outside db 90 °F
Inside db 70 °F Inside db 75 °F
Design TD 28 °F Design TD 15 °F
Daily range M
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 23739 Btuh Structure 22533 Btuh
Ducts 6868 Btuh Ducts 10345 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 30607 Btuh Use manufacturer's data n
Rate/swin multiplier 0.95
Infiltration Equipment sensible load 31235 Btuh
Method Simplified Latent CoolingEquipment Load Sizing
Construction quality Average g
Fireplaces 0 Structure 4076 Btuh
Ducts 2830 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft) 1892 1892 Equipment latent load 6907 Btuh
Volume(f?) 17785 17785 i
Airchanges/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 38141 Btuh
Equiv.AVF(cfm) 113 59 Reqj total capacity at 0.70 SHR 3.7 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Rheem
Trade Trade Existing
Model Cond RA1648AJ1 NB
AHRI ref Coil' RBHP-24J11 SH4
AHRI ref
Efficiency 100 EFF Efficiency 13.0 EER,16 SEER
Heating Input 7.8 kW Sensible cooling 30800 Btuh
Heating output 26550 Btuh Latent cooling 13200 Btuh
Temperature rise 50 °F Total cooling 44000 Btuh
Actual airflow 483 cfm Actual airflow 1467 cfin
Airflowfactor 0.016 cfm/Btuh Airflowfactor• 0045 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.83
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
2020-Feb-2618:12:25
Ar- wrightsoft'
•�•--'°^�•'••w^--+�•••�+ RighFSute®Uriversa1201919.0.07RSU08101 Page 1
'�` ...QUICK1DoameNs\WrighwftHVACIKELLYCORYnip Calc=MJ8 Frordlborfaces:S
-�- Duct System Summa ry Job:
wrightsof ®
Date:
Entire House Ely-
QUICK
YQUICK CALCS, INC.
317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM
Project • •
For. CORY KELLY
7508 PENSACOLAROAD,FT.PIERCE,FL34951
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0.28 in H2O 0.28 in H2O
Available static pressure 0.22 in H2O 0.22 in H2O
Supply/return available pressure 0.176/0.044 in H2O 0.176/0.044 in H2O
Lowest friction rate 0.080 in/100ft 0.080 in/100ft
Actual airflow 483 cfm 1467 cfm
Total effective length(TEL) 184 ft
SupplyBranch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (n) (in) Mat! Ln(ft) Ln(ft) Trunk
BATH c 2261 49 101 0.080 6.0 0x 0 MFx 51.5 95.0 st2
BATH c 111 1 5 0.080 4.0 Oxo MFx 0 0
BEDROOM2 c 4695 88 210 0.080 8.0 Oxo MFx 39.9 95.0 st2
BEDROOM-A C 4582 . 51 204 0.080 7.0 Ox 0 MFx 40.7 95.0 st2
CLOST2 c 252 11 11 0.080 4.0 Ox 0 MFx 41.7 95.0 st2
FAMILYROOM-A C 4313 103 192 0.080 9.0 Ox 0 MFx 27.6 95.0 st1
KITCHENCINING C 2945 17 131 0.080 7.0 OX 0 VIFx 29.8 95.0 st1
WCHENIDINING-A C 2945 17 131 0.080 7.0 Ox 0 MFx 23.8 95.0 st1
LIVING C 7475 79 334 0.080 80 Ox 0 MFx 45.8 95.0 st2
OFFICE C 3300 68 147 0A80 7.0 Ox 0 VIFx 9.2 1 70.0
SupplyTrunk Detail Table----
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st1 PeakAVF 136 455 0.080 580 12.0 0 x 0 VInIFIx
st2 PeakAVF 278 860 0.080 804 14.0 0 x 0 VinlFlx
Bold iitalic values have been manually overridden
W Pightsoff® 2020-Feb-2618:1225
awR.wna„w.0�m.w, Right-Sute@ Uriversal 2019 19.0.07 RSU08101 Page 1
QUICK\Doamerds\WrightsoftWACUtELLXCORYxW Calc=MJ8 FrontDoorfaces:S
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Mat Trunk
rb2 Ox 0 120 324 37.1 0.120 183 98.0 Ox 0 MFx
rb5 0x.0 100 305 0 0 0 0 Ox 0 MFx
rb4 Ox 0 90 345 0 0 0 0 Ox 0 MFx
rb6 Ox 0 89 214 0 0 0 0 Ox 0 MFx
rb1 0x0 84 279 0 0 0 0 Ox 0 MFx
Bold italic values have been manually overridden
- - wrigt�tsoft, 2020-Feb-2618:1225
Auuor n rwo H.w.ice..— Right-Siite®Uriversal201919.0.07RSU08101 Page 2
ACCK QUICK1Dcamerds\WrIghtsoftHVAC\KELLXCORY W Calc=MJ8 FroruDoor faces:S