Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Inspection Docs
II FAMILYROOM {�I I ®'192 cb - - r 11'Chim' CLOST 447 dm f �j OFFICE - KITCHEJdIDINING BEDROOM2 4� Y 131efrti 5cft. }9,210cfin 1711 2l.wo 71 131cim ! x j. 811 HALL �- C S 7" 12x12x1 [0v334cfm 6�„ `'^- ENTRY BEDROOM BATH"� IE GARAGE 101,0H .f y , Job#: Scale 1 112 eed. QUICK CALLS,INC. FvOb 1 CORYIELLY 317ST LUCIELANE: Righ#SuWUnkersa12019 I 75PBPENSACOLAROAD FORT PIERCE FL;34946 1.9DD7RSU08101 FT.PI RCE,FU46 1 IPhone:77c_FI-6799. 2024-Fc�261811327 -W rig aOAOL.COMrohtsaBHVAdV<ELIY,CORY.ryp Project Summary J e: - - wrightsoft® Entire House By. QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phom:772-466-6799 Email:QUICKCALCS@AOL.COM Project • • For. - CORY KELLY 7508 PENSACOLA ROAD,FT.PIERCE,�FI-34951 Notes: Design Information Weather: Fort Pierce,FL,US Winter Design Conditions i Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23739 Btuh Structure 22533 Btuh Ducts 6868 Btuh Ducts 10345 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30607 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Infiltration Equipment sensible load 31235 Btuh Method Simplified Latent CoolingEquipment Load Sizing Construction quality Average g Fireplaces 0 Structure 4076 Btuh Ducts 2830 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft) 1892 1892 Equipment latent load 6907 Btuh Volume(f?) 17785 17785 i Airchanges/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 38141 Btuh Equiv.AVF(cfm) 113 59 Reqj total capacity at 0.70 SHR 3.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade Existing Model Cond RA1648AJ1 NB AHRI ref Coil' RBHP-24J11 SH4 AHRI ref Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating Input 7.8 kW Sensible cooling 30800 Btuh Heating output 26550 Btuh Latent cooling 13200 Btuh Temperature rise 50 °F Total cooling 44000 Btuh Actual airflow 483 cfm Actual airflow 1467 cfin Airflowfactor 0.016 cfm/Btuh Airflowfactor• 0045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2020-Feb-2618:12:25 Ar- wrightsoft' •�•--'°^�•'••w^--+�•••�+ RighFSute®Uriversa1201919.0.07RSU08101 Page 1 '�` ...QUICK1DoameNs\WrighwftHVACIKELLYCORYnip Calc=MJ8 Frordlborfaces:S -�- Duct System Summa ry Job: wrightsof ® Date: Entire House Ely- QUICK YQUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM Project • • For. CORY KELLY 7508 PENSACOLAROAD,FT.PIERCE,FL34951 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.28 in H2O 0.28 in H2O Available static pressure 0.22 in H2O 0.22 in H2O Supply/return available pressure 0.176/0.044 in H2O 0.176/0.044 in H2O Lowest friction rate 0.080 in/100ft 0.080 in/100ft Actual airflow 483 cfm 1467 cfm Total effective length(TEL) 184 ft SupplyBranch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (n) (in) Mat! Ln(ft) Ln(ft) Trunk BATH c 2261 49 101 0.080 6.0 0x 0 MFx 51.5 95.0 st2 BATH c 111 1 5 0.080 4.0 Oxo MFx 0 0 BEDROOM2 c 4695 88 210 0.080 8.0 Oxo MFx 39.9 95.0 st2 BEDROOM-A C 4582 . 51 204 0.080 7.0 Ox 0 MFx 40.7 95.0 st2 CLOST2 c 252 11 11 0.080 4.0 Ox 0 MFx 41.7 95.0 st2 FAMILYROOM-A C 4313 103 192 0.080 9.0 Ox 0 MFx 27.6 95.0 st1 KITCHENCINING C 2945 17 131 0.080 7.0 OX 0 VIFx 29.8 95.0 st1 WCHENIDINING-A C 2945 17 131 0.080 7.0 Ox 0 MFx 23.8 95.0 st1 LIVING C 7475 79 334 0.080 80 Ox 0 MFx 45.8 95.0 st2 OFFICE C 3300 68 147 0A80 7.0 Ox 0 VIFx 9.2 1 70.0 SupplyTrunk Detail Table---- Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 PeakAVF 136 455 0.080 580 12.0 0 x 0 VInIFIx st2 PeakAVF 278 860 0.080 804 14.0 0 x 0 VinlFlx Bold iitalic values have been manually overridden W Pightsoff® 2020-Feb-2618:1225 awR.wna„w.0�m.w, Right-Sute@ Uriversal 2019 19.0.07 RSU08101 Page 1 QUICK\Doamerds\WrightsoftWACUtELLXCORYxW Calc=MJ8 FrontDoorfaces:S Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Mat Trunk rb2 Ox 0 120 324 37.1 0.120 183 98.0 Ox 0 MFx rb5 0x.0 100 305 0 0 0 0 Ox 0 MFx rb4 Ox 0 90 345 0 0 0 0 Ox 0 MFx rb6 Ox 0 89 214 0 0 0 0 Ox 0 MFx rb1 0x0 84 279 0 0 0 0 Ox 0 MFx Bold italic values have been manually overridden - - wrigt�tsoft, 2020-Feb-2618:1225 Auuor n rwo H.w.ice..— Right-Siite®Uriversal201919.0.07RSU08101 Page 2 ACCK QUICK1Dcamerds\WrIghtsoftHVAC\KELLXCORY W Calc=MJ8 FroruDoor faces:S