Loading...
HomeMy WebLinkAboutProduct approval, metal roofing 1128!2020 Florida Building Code Online �„q m "�- �•�' •v .�5 �.:. r•3 kti <n, �4 �"�`" �T �was � 'y'_ �'7`;e. n X �A`-1,-,..A�'� a¢�1^f }k � .n� •�'�5b'� t "" '3� ti� i1L �i� tru^v„• i .fF"r'n_�^'' 'y*, I �.'��r ,�+K� 1 t,�r, s- bco xs' '� �n ��';� ' '(��r7 oft^ ``"�`�, � ���,gy'+�6P1 n � if g :<� �*s�5afi�'� � R �,•°'a '�„�,. f. 8" {i 8 x a� '"3• y,'�Z,r"�e°�''�'C f .. r#:�,y�,++� ,.s6 ,k�.i ��-.t - .�...�Z�,.i._'1a>✓.a`��aL��.cr ci,.��..�ir t a._, '� ,i#:s.' � ,�rv,� {.:� , :, ..• ,::. .I. BUS Home ` Log Ih j User Registration I Hot Topics I Submit Surcharge j Stats&Fact✓ I Publications It Contact Us I BQs Site Map i Links j search I Florida iib Product Approval ��USER:Public User + Product Approval Menu>Product or Application Search>Application List F^ Search Criteria �`{ O Refine Search Code Version 2017 FL# 'd 11560 Application Type ALL Product Manufacturer �y^{ '��, ALL Category ALL Subcategory �� ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant, ALL Design Pressure ALL Other ALL Search Results-Applications FL# Type Manufacturer Validated By. Status FL11560-113 Revision Metal Sales Manufacturing Corporation Yoosef Lavi, P.E. Approved History, Category:Roofing (214)340-0049 Subcategory: Metal Roofing -Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.COD_yright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.if you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: w t�s.�„• w� ® eC lxcl � . Credit Card Safe . REVIEWED FOF.. �. -vile19 CIE CnUr BOCC i https:tlfioridabuilding.org/pr/pr app_Ist.aspx 1/1 i EVALUATION REPORT OF METAL SAFES MANUFACTURING CORPORATION `26 GA.IMAGE 11 PANEL' . FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 41560.4-R3 ROOFING METAL ROOFING Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville,KY 40202 Telephone: (502) 855-4300 Fax: (5012) 855-4200 Prepared By: Bala Sockalingarn, Ph.D.,P.E. Florida Professional Engineer#62240 1216 N Lansing Ave.,Suite C Tulsa,OK 74106 Telephone: (918)492-5992 FAX: (866)366-1543 This report consists of Evaluation Report(3 Pages including cover) Installation Details (1 Page) cq'SoCKq j 1, a��� No 62240 Report No. C2181-4 �', STATE OF •zzi «< Date: 9.8.2017 ` \ .' 40RI NA q�l q 20 1,'7 i I FL 11560.4-R3 C2181-4 9.8.2017 Page 2 of 31 Manufacturer: Metal Sales Manufacturing Corporation Product Name: Image H Panel Description: Max. 16"wide coverage with 1" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel(ASTM A792) or painted steel(ASTM A755). Deck Description: Min. 15/32" thick plywood or min. W thick wood plank (min SG of 0.42) for new and existing constructions. Designed and installed as per FBC 2917. Deck Attachment: 8d x.2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c. (Minimum) in the field and @ 4" o.c. at edges. Designed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt. For reroofing (Optional) construction only. Slope- 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 84.25 psf @ fastener spacing of 24" o.c. (Factor of Safety=2) Fastener Pattern: #10-12 pancake head screws along panel seam. Fastener shall be of sufficient length to penetrate through the deck a ininimum.of 1/4". Test Standards: Roof assembly tested in accordance with TAS 125-03 'Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation, Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM ElOSM790 report from an accredited laboratory for fire ratings of this product. FL 11560.4-R3 C2181-4 9.8.2017 Page 3 of 3 Supporting Documents: TAS 125 Test Reports Hurricane Test Laboratory,LLC HTL Report#: 0103-0714-09,Reporting Date 9/1%09 i mow, 0.5. O.S. �., 'n�� 'n' I . a it NEW UNDERLAYMENT SEE DETAIL 1 MAX. 16" 'PANEL FASTENER ROOF PANEL EXISTING SHINGLES SPACING PER ALLOWABLE m (OPTIONAL) PRESSURE TABLE. a u —– - -- 7MIN. PLYWOOD MINIMUM ATTACHMENT: 15/32" THICK (MIN.) 8d x 2.5" LONG RING SHANK NAIL_ OR #8 x 2" LONG WOOD SCREWS o TRUSS AT MAX. 24" O.C. SPACED ® 6' O.C. IN THE FIELD X O & ® 4" O.C. AT PLYWOOD EDGES 0 N 0 wN Z TYPICAL PANEL INSTALLATION X—SECTION Nto �o NJ� MSI N N =VjO 5s� MIN 26 GA. PANEL ALLOWABLE UPLIFT PRESSURE FASTENER PRESSURE _ `n SPACING (PSF) NEW UNDERLAYMENT (IN) #1O PANCAKE SCREWS EXISTING SHINGLES 24 84.25 a (OPTIONAL) w C u 2 w -E wwx� EXISTING UNDER LAYMENT GENERAL NOTES: rn (OPTIONAL) q PLYWOOD 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE DETAIL 1 15/32"THICK (MIN.} 2, ROOFLORFPANELSTNG ARE SHALL BE)MIN. 26 GA. MAX. EFFECTIVE COVERING WIDTH OF u PANEL = 16". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM. REQUIREMENTS OF THIS DRAWING& THE CODE, THE CODE SHALL CONTROL. 6, RAFTERS/JOISTS/TRUSSES MUST. BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE.RESPONSIBILITY OF OTHERS. - 2181-4 PAGE N0 1 OF 1 1/28/2020 Gmail-Final Roof inspection completed for project 19-4906 Gmail Edward LEC14NER<edificiumroofing@gmail.com> Final Roof inspection completed for project 19-4906 no-reply@mygovernmentonline.org<no-reply@mygovemmentonline.org> Tue,Jan 28,2020 at 1:46 PM To: EDIFICIUMROOFING@gmail.corri i?« iC:c1 Ef CY t�eF�.s'Si'�. ivy°fir �7 3.'Now.urrj To.see the full inspection-report,login to your account with the Customer Portal. Completed Inspection -Sam Smith;has completed a-Final Roof inspection for project 19-4906 at 193 ENGLAR DR SEBASTIAN FL 32958 on Jan 28 2020 12:46PM. The inspection;Failed The inspector noted Multiple loose fasteners and fasteners without a gasket. To print your inspection report please visit the Permits and Licensing section of www.mygovemmeritonfine.org to add the.project to your account and access the full inspection report. i https://mail.google.comimaiYu/1?ik—=4fe3bcd3cl&view=pt&search=all&permaisgid=msg-f%o3Al656998607185349417&simpl=msg-f%3Al6569988071... 1/1 I