HomeMy WebLinkAboutProduct approvals ~ -- 2160 SUU Portia Drive
Palm City, FL 34990
s772:)872-$034
NON iYVHZ1.,Florida Product Approval # 17022.5 1" •
MCUYr.D
Compliant with Florida Building Code 2017 (W1 ed.) 1U1U
Compliant with Florida Product Approval Rule#61G20-3, � �2
Compliant: Keystone' Certifications perm►ttin9 Depart "t
St.Lucie countv
Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength:50 ksi min.; Attached to min.15132" plywood or 0�'�2—
Wood Deck w/0.42 specific gravity with 16" CoverqRgftfE FOR ;I
Rib Height 1" CODE COMPLIANCE
Corrosion Resistant Compliant: FBC Sec. 1507.4.3 t�
Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to pATfr1V 0P' UT I
bottom of support. cc
Adhesive/Sealant : Bostik 91STm Chem-Chalk one component,polyurethane adhesive with
3/16"continuous bead application along base of male rib vertical flange at each panel
seam. 17t5/202'
Underlayment:To be compliant with FBC Sec 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
P P Y
Install.Details:.Table-A _-Allowable Loads._ __ METHOD.1. _ ETHOD .2_ rr
`DESIGN PRESSURE* -8.6 PS_F_ Main f he/d -97.25 PSF Perimeter ~ t.
FASTENER SPACING _ 6"O.C. — 6"O.C.
-SEAM ADHESIVE Not required 3/16 continuous bead
(see details)
Reference Data: ARCHITECTURAL TESTING,INC.TST ID#: 1527
UL 580-06&UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen#1'
J EQU_I_VALENCY_UL1897.-04 is equivalent.to.Test Standard MLI897-17. ,-*D_esi n.Pressure._mar in.of safe
Certificate of Independence:
Locke Bowden,P.E.does not have,not will acquire a financial,i90M0bnggy cbmpany manufacturing or distributing products
under this evaluation. ���`�`L D. BOy��?i,
Locke Bowden,P.E.Is not owned,operated,or contrail y ,cturer,or distributing products under this
report.
w •
* • seal •
;' -File Copy
��'• STATE OF ,�t.,r I
s.
01VA1- 1v;ti
:::..lilt•
i -
.I
I
Limitations:
1.Undedayment to be compliance with current Florida Building Code(FBC)2017 61h ed..
2.Minimum slope to be compliant with Florida Building Code 2017 6th ed.,and per with Manufacturers installation reference.
3.Products are compliant for State of Florida product approval per Rule 61 G20.3.,Compliance Method:1-D
4.Engineering analysis for"project specific approval by local authorities wrjurisdiction is allowed by other registered engineers.
5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report
6.Support framing in compliance w/FBC 2017 Uh ad.,Chapter 22 for Steel,Chd pter 23 for Wood and Chapter 16 for Structural
Loading.
7.This report does not imply warranty,installation,recommended product use outside of this report
FL 17022.5 1.0 Nail Strip(26GA Steel), 16'Wide Roof Panel-Details
3AV1
Panel Profile
Deck:
-15/32"or greater Plywood,or
-Wood plank
Integral Snap Lock
For METHOD 2: it I
Apply 3/16"Bead Bostik 9151m Sealant
Continuous Along Male Rb Vertical Flange
Fastener it
#10xl"Min. per Table W
Pancake Head Wood Screw
I (Typical Fastening Pattern Across Width)
rr I
Y�
I
FL 17022.5 . 1 A Nail Strip(26GA Steel),16"Wide Roof Panel-Details
,I
Fastener
#10 X 1"Min. per Table
Pancake Head Wood Screw
1"Nail Strip Roof Panel
III
a
Seam Adhesive Application:
Deck: For Method 2
-15132"or greater Plywood,or Apply 3116"Bead Bostik 915Tm Sealaiid
-Wood,plank Continuous Along Male Rb Vertical Flange
(Refer to Table"A")
Isometric View
I�
I '
I
Ili .
I
I
s s
^ t'til � CD
7
Perm.
S Ittjn9 Q
LUr1e epartColl Tent
x Certificate of Authorization#32455
t / 4 353 Christian Street, Unit#13
Oxford, CT 06478
�— (203)262-9245
Ei�?GiitiEE C --VALU.4 E _jT CONSULT CERTIPI
".-a
�-'`°" n »'� r'�..,.�..,..__.t�w- T�x,'�'�•�r""^t*� �3" ^_'y� t"} 7
'" - '�`,a. �a s '� 7.K r �.r 't'�" !'f. �'�'v`w -.rfi j^_•-.-t�.�`",�: .r�..r .r - _- •s v.c.>.�t7�'4, --? -<u;-...s,:�. ,4� Vii' ..u'
Boras Roofing Evaluation Report M35710.12.10-1111
7575 Irvine Center Drive,Suite 100 FL14317-R10
Irvine,CA.92618 Date of Issuance:12/21/2010
(602)269-2289 Revision 11:10/12/2018
SCOPE:
This Evaluation Report is issued under Rule 61620 3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products
described herein have been evaluated for compliance with the 61'Edition(2017)Florida Building Code sections noted
herein.
DEscmmom Boral Roof Underiayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.of any changes to the
product(s),the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words "MEMO I etc. Evaluated" may be displayed in
advertising literature. if any portion of the Evaluation Report is displayed,then it shall be done in its entirety.,
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This.Evaluation Report consists of pages 1 through S.
Prepared by:
Robert J.M.Nieminen,P.E.
^r>• The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA A1VE1983 _�%,;,;,;;, •`` Nleminen,P-E.an 10/12/201&This does not'seme as an
electronically signed document
CERTIFICATION OF INDEPENDENCE:
I. MEMO ETC,LCC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEW ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
Copy-
A
��•Je�.d
ROOFING COMPONENT fvALUATION:
l� rl ya e31 } �`fi s S s i- •t 3�"h 4+r t F '~-k. Y�- r z '`sr4'• '�y 3 7 �w*..:�3. t p � 'E 7. t' 7
Product Category: wRoofing
Sub-Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated
compliance with the following sections of the 6' Edition (2017) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/Conditions of Use set forth herein.
AZI .a fi ` 'c` `' �;�`• "Ki�,3_zr 3�-z F� r ,� ., ,r.. R, .�.. o-s•- J cAll
..w-;3 �'__ ,.eta. ..:^ •c" •ic. � _� e, ...>,. _ r�-r:= '��1.. }�� 1' �
Section Property Standard Year
1504.3.1 Wind Uplift UL 1897 2012
1507.1.1,T1507.1.1, Physical Properties ASTM D1970 2015
1507.2.9.2
1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012
.,
Enti Examination References Date
ERD(TST 6049) Physical Properties M36790.07.11 09/30/2011
ERD(TST 6049) Physical Properties 1340380.08.12 08/28/2012
ERD(TST 6049) Tensile Adhesion/LTA 041420.09.12-2 09/11/2012
ERD(TST 6049) Adhesion 641940.09.12 09/13/2012
ERD(TST 6049) Tensile Adhesion/LTA 847390.07.14-1 07/31/2014
ERD(TST 6049) Tensile Adhesion/LTA 647390.09.14 09/04/2014
OC(PDM1838) Physical Properties Equivalency statement 11/02/2017,i
PRI(TST5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010
PRI(TST5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010
PRI(TST5878) Tensile Adhesion/LTA NEI-045-02-01REV 12/17/2010'
PRI(TST5878) FRSA/TRIApril 2012 NEI-076-02-01 02/14/2011
PRI(TST 5878) ASTM D1970 NEI-034-02-02 01/29/2013
PRI(TST 5878) Wind Uplift BORR-001-02-01 03/17/2015
PRI(TST 5878) Wind Uplift BORR-005-02-01 06/24/2015
PRI(TST5878) Tensile Adhesion/LTA DAPF-002-02-01 03/08/2018
PRI(TST 5878) ASTM D1970(adhesion) OCF-443-02-01 10/11/2018
UL,LLC.(QUA 9625) Quality Assurance Service Confirmation Exp.08/21/2020
j } z
_ nom_,='s' .-��1.'� _sn"�.Y v?"�a.r ��„'3Y..'� c-r..a.;;r'jkr-.<. _ _ z... L-s��' a.+`I 7£..e...•"� s- � 5 �,,
4.1 Boral" TileSeal 50HT is a nominal 50-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof'
underlayment;meets ASTM D1970.
4.2 Boral° TileSeal"T is a nominal 60-mil thick, polyester-surfaced, self-adhering SBS modified bitumien roof
underlayment;meets ASTM D1970 and FRSA/TRI 04-12.
4.3- BoralO MetalSeall is a nominal 60-mil thick, polyester-surfaced, self-adhering 5BS modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRI 04-12.
4.4 GatorSealO is a nominal 55-mil thick,granular-surfaced,fiberglass reinforced,self-adhering SBS modified bitumen
roof underlayment;meets ASTM D1970.
4.5 CitadelD Plus is a nominal 48-mil thick,fabric-surfaced,fiberglass reinforced,self-adhering SBS modified bitumen
roofing underlaymentfor use as a base-layer in multi-ply underlayment systems;meets ASTM D1970.
I
11JER110 ETC,LLC Evaluation Report M35710.12.10-Ril
Certificate ofAuthoraation#32455 6MEL510N(2057)FSCNOP HVi;2EVALUATION FL1n,317.1110
Boral Roof Underlayments;(602)269-2288 Revision 11:10/12/2018
Page 2 of 8
I .I
I
( �S kl._h
est� s
G' i" E E,ta 3a, hS �U
'a s ,
...> T .-.r.C.e._ .o ..�.._,�.,,__•..P,:.7:,...zx ..,.�::_ '"2....,...Z�x_ vet t' .,,$'.�'..:.�4..a, k s 7As. =_r_ -.,�;:�.c
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Laboratory Report;refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by-itself beneath the stated roof
covers. Refer to the installation instructions for multi-ply underlayment options.
Asphalt Adhesive-set Wood Shakes
UnderJayment Shingles Nail-On Tile Tile Metal !✓Shingles Slate
Boral UleSeal 50HT Yes No No Yes Yes Yes
oral TileSealHT Yes Yes Yes Yes Yes Yes
(See 5.5.1)
Boral MetalSeal"T Yes Yes Yes Yes Yes Yes
(See 5.5.1)
GatorSeal Yes No No I No Yes Yes
5.5.1 "Adhesive-set Tile"is limited to use of following Approved tile adhesives/underlayment combinations.
fY5.-S,�
Adhesive Florida Product Underlayments
Approval
DAP Foam Touch'n Seal StormBond Roof Tile Adhesive FL14506 Boral TileSeall or Boral MetalSeall
DAP Foam Touch'n Seal StormBond 2 Two-Component
Polyurethane Roof Tile Adhesive FL21374 Boral TJIeSeal or Boral MetalSealHT
Dow TILE BOND'"Roof Tile Adhesive FL22525 Boral TileSeall or Boral MetalSealHT
ICP Adhesives Polyseta AH-160 FL6332 Boral TileSeall or Boral MetalSealHT
ICP Adhesives Polyset°RTA-1 FL6276 Boral TileSeall or Boral MetalSeall
s Refer to Tile Manufacturer's or Adhesive Manufacturers Florida Product Approval for Overturning Moment Resistance Performance.
NEMA ETC,LLC Evaluation Report M35710.12.10-1122
Certificate ofAuthorkatron#3245 6"'EDIT1QN(202 )ES N10N_,I,V.j%ElIALUAtiC:i1 0
Boral Roof Underlayments;(602)269-2288 Revision 11:10/12/2018
Page 3 of 8
I
I
5.6 Allowable Substrates:
5.6.1 Direct Bond to Deck:
Citadel Plus,Boral TileSeal 50HT,Boral TileSeal";Boral MetalSeal"T or GatorSeal:
a Plywood(unprimed or primed with ASTM D41 primer).
Boral TileSealHT or Boral MetalSeal"T:
OSB(unprimed or primed with ASTM D41 primer).
Note:Refer to Section 5.6.4 for uplift limitations associated with direct-deck underlayment installations where the
overlying roof cover is adhesive set Nle roofing
5.6.2 Bond to Base Laver Underlavment:
Citadel Plus,Boral TileSeal 501,Boral TileSeal",Boral MetalSeal"T or GatorSeal:
9 ASTM D226,Type ll felt;Citadel Plus.
For installations under mechanically attached prepared roof coverings,base layer shall be attached per minimum
codified requirements. For installations under adhesive-set tile systems,base layer shall be attached per minimum
requirements of FRSA/TRI April 2012(04-32),Appendix A,Table 1,or as listed in Section S.6.4 herein,or as tested
in accordance with FBC 1504.3.1.
5.6.3 Bond to Other Substrate Types:
Citadel Plus,Boral TileSeal 50"'Boral TileSeal"'Boral MetalSeal"T or GatorSeal:
a ASTM D41 primed metal(e.g.,flashing metal,valley metal,etc.).
Boral TileSeal"T:
Huber Zip Deck(unprimed or primed with ASTM D41 primer);Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval.
5.6.4 Wind Resistance for Underlavment Systems in Adhesive-set Tile Applications: FRSA/TRI April 2012(04-12)does
not address wind uplift resistance of all underlayment systems beneath adhesive-set tile systems, where the
underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012(04-22)and are used in adhesive-set the applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer
to FRSA/TRI April 2012(04-12),Appendix A,Table IA or FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure=-120.0 post:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority, Having
Jurisdiction_
Primer: (Optional)ASTM D41 to the plywood deck
Base Ply: Citadel Plus,self-adhered
Cap Sheet: Boral TileSeal"T or Boral MetalSeal"T,self-adhered,and back-nailed within the selvedge-edge side laps
using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o:c.
#2 Maximum Design Pressure=-1425 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority) Having
Jurisdiction.
Base Ply: None
Cap Sheet: Boral TileSeal"'or Boral MetalSeal"T,self-adhered and back-nailed within the selvedge-edge side laps
using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o:c_
i
idEYQ zit LLC Evaluation Report M35710.12.10-R11
Certificate of Authorization#32455 6"'EWTION(2012.711 FBr_M0iN-!?y %EVALUATION �L3�3�7-F iO
--- -- -- $oral Roof Underlayments;(602)269-2288 —_..--_-___. Revision 11:10/12/2018
Page 4 of 8
I
I
#3 Maximum Design Pressure=-202.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority; Having
Jurisdiction.
Primer: Tropical Roofing Products#410 Quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply: None
Cap Sheet:' Boral TIIeSeal"T or Boral MetalSeal";self-adhered,and back-nailed within the selvedge-edge side laps
using 12 ga.x 1%"ring shank nails through 32 ga,1-5/8"diameter tin caps spaced 12-inch o:c.
94 Maximum Design Pressure=-210.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority,,Having
Jurisdiction.
Primer: KARNAK#89 Sta-Tak Primer to the plywood deck
Base Ply: ; None
Cap Sheet: Boral T)IeSeal"T or Boral MetalSeall,self-adhered,and back-nailed within the selvedge-edge side laps
using 12 ga.x 1Y4"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure=-220.0 psf:
Deck: Min.2,500 psi structural concrete to meet project requirements to satisfaction of Authority;Having
Jurisdiction.
i
Primer: ASTM D41 to the concrete deck
Base Ply: (Optional)Citadel Plus,self-adhered
Cap Sheet:� Boral T)leSealHT or Boral MetalSeall,self-adhered
5.6.4.1 Note:For adhesive-set the systems,if there is a base ply or mid-ply of Citadel Plus in the system,the project design
pressure requirements may not exceed-120 psf.
5.7 Exposure Limitations:
GatorSeal shall not be left exposed for longer than 30-days after installation,priorto placement of final roof cover.
Boral TileSeal 50";Boral TileSeall or Boral MetalSeall shall not be left exposed for longer than 180-days after
installation,prior to placement of final roof cover.
Citadel Plus,for use as a base-layer in a multi-ply underlayment system,shall not be left exposed for longer than
180-days after installation,prior to placement of subsequent underlayment layer.
5.8 Tile Slippage Limitations(FRSA/i RI April 2012(04-12)1:
When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
Underlavment Tile Profile Staging Method X Maximum Slope
' Boral TileSeal"T or Flat Max.10-tile stack 6:12
Boral Metalsea1HT Lugged Max.10-tile stack 6:12
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation Instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Install self-adhering underlayment when ambient and surface temperatures are minimum 40°F and rising.''
NEf4G0"C,LLC Evaluation Report M35710.12.10-Rll
Certificate ofAuthorization 1132455 bra=DIT10N(2G=7)FBC i i0H-FillHZ 5EVA LUA1-1G!N F L_43_7-111_0
Boral Roof Underlayments;(602)269-2288 Revision 11:10/12/2018
Page 5 of 8
. I
a
$..SIE
6.4 Citadel Plus:
6.4.1 Citadel Pius is limited to use as a base or mid-layer in multi-ply underlayment systems beneath Boral TileSeal 50HT,
Boral TlleSeal"T or GatorSeal.
6.4.2 Slope limitations are those associated with the top-layer underlayment.
6.4.3 Direct to Deck:
Cut the membrane into manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge,
extending over by X-Inch.Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck,pressing firmly into place. Roll into place with
a weighted roller.
Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails &tin-tags or 1-inch
diameter plastic or steel cap nails spaced maximum 12-lnch'o.c. Overlap successive courses the entire width of the
black-selvedge area,minimum 2 inches(horizontal lap)and minimum 6"end(vertical)laps.
install final underlayment layer atop Citadel Plus per`direct-to-deck' instructions for Bora)TileSeal 501, Boral
TileSeal"T,Boral MetalSeaIHT or GatorSeal.
6.4.4 To Base Sheet:
Install base sheet of ASTM D226,Type 11 felt in accordance with Code requirements or install base ply of Citadel
Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part
of a multi-ply system.
install optional Citadel Plus as a mid-ply in accordance with Boral Roofing published installation instructions and
Section 6.4.3. '1
install final underlayment layer atop Citadel Plus per'direct-to-deck' instructions for Boral TileSeal _'O�j F, Boral
TifeSeaIHT or GatorSeal.
Note:For adhesive-set tile systems,if there is a base ply or mid-ply of Citadel Plus in the system,the project design
pressure requirements may not exceed-120 psf.
6.5 Boral TileSeal 50"T:
6.5.1 Shali be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.3 for
the type of.prepared roof coveringto be installed.
6.5.2 Do not use Boral TileSeal 50"T on roof pitches less than 2:12.
6.5.3 Non-Tile Applications.Direct to Deck:
Cut the membrane into manageable lengths, 'typically 10 to 12 ft.Align the membrane parallel to the roof edge,
extending over by%-inch.Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck,pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails,nails&tin-tags or 1-inch diameter
plastic or steel cap nails spaced maximum 244nch o.c.for slopes below 7:12 and maximum 12-inch o.c.for slopes
7:12 and greater. Overlap successive courses the entire width of the black-selvedge area,minimum 3-inch'_
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam
method detailed in Boral Roofing published installation instructions.
i
;I
NEtv70�,C,LLC Evaluation Report M35710.12.10-R12
Ce�GoteofAuthorizotton#324531 6�' EDITIONS(20=7)PSCM10M_HVHZEVALUA7110N FL34.'317-1110
Bora[Roof Underlayments;{602}269-2288 Revision 11:10/12/2018
Page 6 of 8
� I
i
6 1 }�
6.5.4 Non-Tile Applications,to Base Sheet:
Install ASTM D226,Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal 501 in accordance over ASTM D226,Type II felt or Citadel Plus with Boral Roofing published
installation instructions and Section 6.5.3,except end(vertical)laps,described below.
Apply SBS Mastic under all end(vertical)laps or any other laps where the self-adhering bituminous underside is in
contact with the fabric top surface,rolling the interface into'place with a weighted roller.
6.6 GatorSeal:
6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507,1.1 for
the type of prepared roof covering to be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12.
6.6.3 Non-Tile applications,Direct to Deck:
Cut the membrane into manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge,
extending over by%-inch.Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck,pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails,nails&tin-tags or 1-inch diameter
plastic or steel cap nails spaced 24-inch o.c.for slopes below 7:12 and 12-inch o.c.for slopes 7:12 and greater.
Overlap successive courses the entire width of the black-selvedge area,minimum 3-inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self-adhering
bituminous underside is in contact with the granular or mineral top surface,rolling the interface into place with a
weighted roller,or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions.
6.6.4 Non-Tile Applications,to Base Sheet:
Install ASTM D226,Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install GatorSeal over ASTM D226,Type 11 felt or Citadel Plus in accordance with Boral Roofing published installation
instructions and Section 6.6.3 except end(vertical)laps,described below.
Apply SBS Mastic under all side(vertical)laps or any other laps where the self-adhering bituminous underside is in
contact with the granular top surface,rolling the interface into place with a weighted roller.
6.7 Boral TileSeal"r or Boral MetalSeal"r:
6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507:1.1 for
the type of prepared roof covering to be installed.
6.7.2 Do not use Boral TileSeal"T or Boral MetalSeal"T on roof pitches less than 2:12.
6.7.3 Non-Tile Applications,Direct to Deck:
For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membra) a into
manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge,extending over by Y-inch.
Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane v ith the
exposed rubberized asphalt onto the deck,pressing firmly into place. Roll into place with a weighted roller.
Fasten the black selvedge edge to the deck with roofing nails,nails&tin-tags or 1-inch diameter plastic or steel
cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black-selvedge area,
minimum 3-inch.
Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral
Roofing published installation instructions.
NEW10 ETC,LL_ Evaluation Report M35710.12.10-1111
certifrcate ofAutharizatian#32455 6r'EDITION(201-7)FBC i+!OP!HVHZ-EVALUATlo�W+ FLI4317-R1rz
Boral Roof Underlayments;(602)269-2288 Revision 11:10/12/2018
Page 7 of 8
i
i , tlN�s$.ji
6.7.4 Non-Tile Applications,to Base Sheet:
Install ASTM D226,Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boras Roofing published installation instructions and Section 6.4.
Install Boral TileSeal"T or Boral MetalSeaPHT over ASTM D226,Type If felt or Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.7.3,except end(vertical)laps,described below.
Apply SBS Mastic under all end(vertical)laps or any other laps where the self-adhering bituminous underside is in
contact with the fabric top surface,rolling the interface into place with a weighted roller.
6.7.5 Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12)installation Manual and Table 1 herein,using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s),
Base Sheet fastening shall be not less than FRSA/TRI April 2017. (04-12),Table 1.
For adhesive-set file applications,refer to Section 5.6.4 herein.
Note:For adhesive-set file systems,if there is a base ply or mid-ply of Citadel Plus in the system,the project design
pressure requirements may not exceed-120 psf.
Refer to Section 5.8 for tile staging limitations. Battens must be used for all the installations atop Boral TileSeal"T
or Boral MetalSeal"T with roof pitches of 21 to less than 3:12. Boral Roofing's Elevated Batten System or counter
battens are required.
s�������� �����jr(�:.q_:���r�v,�4'{.53�,�,-�E N�r� ��_i.+� i �"'� _ `'"' r5f�� �� c .t• 7} .t s� � x�• y
As required bythe Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
� ..h..-�,f .. ;..-.: �5'- to �,.... .._, -:`cK 1 ,::�•� T 7. .�
Brentwood,NH
3w.�. _�:.•_ . .�, sMa ,...;...a_�..._ ... _ __...�-,a w..�..a .,-...-, ...,r.. - :s zt° ,�._vx..._.5:, r�"'�` ,,,•is�._.
UL,LLC.—QUA9625;(631)546-2458; K4nci�i.a ralr�ala-Do„nia(a ul.cam