Loading...
HomeMy WebLinkAboutProduct Approvals 2/26/2020 Florida Building Code Online BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge I Stats&Facts I Publications Contact Us ( E Florida Product Approval FUSER: Public User P R!_CETVTM Product Approval Menu > Product or Application Search > Application List> Application Detail FEB 2& 2020 FL # FL27499-R1 Permitting Departrn2nt Application Type Revision $t, Lucie county Code Version 2017 Application Status Approved Comments Archived � � - o7SJ Product Manufacturer Dynamic Metals Address/Phone/Email 3201 SE Dominica Terace Stuart, FL 34991REVIE ED F®R (772) 872-8 3 juan@dyna ' EeC®MPLIANCE Authorized Signature Lara Jesus ST. LUCIE C®UNTy�®�� , juan@dynamicmetal.ne Technical Representative Address/Phone/Email 12"? C9 Quality Assurance Representative ���� Address/Phone/Email op, y Category Roofing Subcategory Metal Roofing i Compliance Method Evaluation Report from a Florida Registered Archil Professional Engineer U Evaluation Report - Hardcopy Receiived Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/31/2026 Validated By, Lucas A. Turner, P.E., MBA Z, Validation Checklist - Hardcopy Received i Certificate of Independence FL27499 R1 COI Dyn COI.pdf Referenced Standard and Year (of Standard) Standard TAS 100 TAS 110 TAS 125 https://www.floridabuilding.org/pr/pi app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6B4KrS3X7m7RLNDTr%2fv7QaQ%3d%... 1/5 2/2f6/2020 Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code I Product Approval Method Method 1 Option D Date Submitted 02/22/2019 Date Validated 08/29/2019 Date Pending FBC Approval 08/30/2019 Date Approved 10/15/2019 Summary of Products FL # Model, Number or Name Description 27499.1 DM Class 1000 1" Nailstrip 26 Ga. galvalume coated steel roof pa fit seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R1 II NSSI6HZ�pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports i Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Evali.pdf Created by Independent Third Party: 27499.2 DM Class 1000 1" Nailstrip, .032" Aluminum roof panel', 16" wide, Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R1 II NSAI6HZ.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 162354 Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eval2.pdf Created by Independent Third Party: 27499.3 DM Class 1050 1 1/2" Nailstrip .032" Aluminum Roof Panel, 19" Wide, Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R1 II NSAI9HZ,pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eval3.pdf Created by Independent Third Party: 27499.4 DM Class 1050 1 1/2" Nailstrip 24 Ga. Galvalume coated steel roof pa snap fit seams Limits of U'se Installation Instructions Approved for use in HVHZ: Yes FL27499 R1 II NSSI9HZ.pd Approved for use outside HVHZ: Yes Verified By: Scott Wolters;, P.E. FLPE# Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eval, pdf Created by Independent Third Party: 27499.5 DM Class 1500 1 1/2" Mechanical .032" Aluminum roof panel, 20" wide, Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R1 II 15MSA26HZ.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 162354 https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgUHOE2Ywe%2bOsCepABg3%2bkM6B4KrS3X7m7RLNDTr%2fv7QaQ%3d%... 2/5 - - I ` WOLTERS ENGINEERING ENGINEERING,DRAFTING,CONSULTING j 15211 97th Road N West Palm Beach,FL 33412 Ph/Fx:(561)225-1982 PRODUCT EVALUATION (FOR HVHZ APPROVED PRODUCT) PRODUCT: DM CLASS 1000 26 GA. GALVALUME 1" NAILSTRIP 16"WIDE ROOF PANEL (FLPA#27499.1) MANUFACTURER: DYNAMIC METALS, LLC 340 PIKE ROAD WEST PALM BEACH FL 33411 To all concerned, The DM Class 1000 Series 26 Ga. Galvalume 1" Nailstrip 16"Wide Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the requirements of Sections 1507.4 and 1518.9 of the 6th Edition (2017) Florida Building Code. The panel has been tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.40-450-44 and 63443.14- 450-44, and per TAS 110 by PRI Construction Materials Technologies,with results shown in test reports VLS-004- 02-01 and VLS-005-02-01. Technical Documentation: i 1, Drawing "NSS16-HZ"dated 8/15/19, signed and sealed by Scott Wolters, PE, l 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 3. Supplemental Calculations to support"NSS16-HZ"drawing, signed and sealed by Scott Wolters, PE.' I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61G20-3,0051, (4), Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. i Overall Limitations: Maximum Panel Width: 16" (nominal) Fastener Spacing across panel: 16" (at Nailstrip) (Panels overlap with male/female snap fit) Min. Slope: HVHZ: 2712" Non-HVHZ: '/2'/12"(with Lap Sealant) 3712" (no Lap Sealant in Field Zone) li 5P? CIM-01\16 IN IMPACT Ff515TANf CW AINW&I.5, 5f0MFP,0N'(5, &WINPOW5 Field Perimeter& Corner Installation Installation Max. Design Pressure: -116 psf -176 psf Fastener Spacing: 3" From Ends, 6" Max. O.C. 3" From Ends, 6" Max. O.C. Min Panel Fasteners: #10x1" Panclip Fasteners #10x1" Panclip Fasteners Panel Sealant: Continuous bead of Geocel 2300 or 2320 at Nailstrip side of seam Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note#2 below) Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type II with 4"overlaps and 6"end-laps, anchored with 12 Ga. x 1 W galvanized roof nails with 32 Ga.Tin caps spaced 6" O.C. in rows at the perimeter, at overlaps, and two intermediate rows staggered and spaced 12" O.C. (or) Any underlayment with a valid FLPA or Miami-Dade NOA Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent galvanic reactions. I Minimum Substrate: Y2' (15/32" min) 4-ply CDX Plywood, nailed to 2x rafters spaced 24" max. O.C, with 8d ring-shank nails spaced 4"O.C. Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507,4.2'or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 4. Rational analysis, provided by a Florida licensed Architect/Engineer per FAS 61 G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction. 5. All panels shall be permanently labeled with the manfacturer's name and/or logo, and the following statement, "Dynamic Metals FL#27499.1, DM Class 1000". 5PIK LIZING IN IMPACf I?�515fANf CUI?fAINWX.5,5f0FVF,0Nf5, & WINPOW5 I I i i I i Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of 31d party QA provider,to the dimensions shown on Drawing NSS16-HZ: SSQ-6800617 SSQ=5150216 SSQ-6810617 SSQ-669.0517SSQ-4560615 SSQ-8681118 5VC-0490718 5VC-0360516 5VC-0521218 Re.Roofing: The DM Class 1000 Series 26 Ga. Galvalume 1 Nailstrip 16". 6 Wide Roof Panel May be installed over a single layer of existing asphalt.shingles, provide the existing roofl meets the requirements of Section 1521 (HVHZ)or Section 1511 (outside of HVHZ) of th�le Florida Building Code. If you have any,questions or need more information concerning this approval please contact me. ��1tifFEfBJJ `oat W JJ� Thank you, `4y� C,a �TF •,P C E '•�, 4 S N0 62354 Scott o ers �' p FL PE# 62354 0 szArE o 4 AUG 16 7019 d%`�S '� 0 0 10 •'\ .�` ONALS i t I i { I 51'C-CIALIZINCA IN lhnf?P 1`f: 5I51HNf CuGir�Nb`V�1.1 5, 510FfpON1"5, & WINPOW5 i 3 i I j i rn, rw Q 0 ca k CD t1 M v(n N O O a KIDS k � tD..i�; a O .. M. v w CL CO. T N -a o rr t^ O•'C7 a tD :- 27 v f� w to �� m i DYNAMIC METALS MUM -_ - sc a ri'lVM ENGINES VN0 * * - 47 340 PIKE ROAD www.dynamicn)etal.net (CCA"27194) 15211.97111 RM STATE OF. w NAME SUBMITTAL 8 15.19 r I WEST PA00 BEACH,,FL 33782 FAX:(561)629-7291 Assr PAW MACH.FL 3341rk7�q; V.tsr stleMtrrAL — e to is PH:(561)629-7288 EMAIL:in/tl�dynatrtiirnetal.net (567)zzs-wag — s ,,,••., _ �Q�: PRINTS.ISSUED FOR RETU DATE