Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Notice of Acceptance
M IAM I•DADE MIANII-DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES R 11805 W26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION RECEIVE®86)315- 590 F(786)315-2599 NOTICE OF ACCEPTANCE OA www. iamidade. oy/econom PGT Industries,Inc. MAR 0 3 2020 1070 Technology Drive North Venice,FL 34275 ST. Lucie County, Permitting SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami—Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to-comply with the Florida Building Code, including the High Velocity Hurricane Zone.- DESCRIPTION: Series"SH7700A"Aluminum Single Hung Window—L.M.I. APPROVAL DOCUMENT: Drawing No. 7700NOA-1, titled "Aluminum Single Hung Install (LM)", sheets 1 through 11 of 11, dated 04/01/18, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami-Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been 0 no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure LUto comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1 and evidence pages E-1 and E-2,as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. NOA No.18-0430.06 MIAMI•DADE COUNTYJM Expiration Date: August 23,2023 Approval Date: August 23,2018 Page 1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. 7700NOA-1, titled "Aluminum Single Hung Install (LM), sheets 1 through 11 of 11, dated 04/01/18, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC,TAS 202-94 3) Water Resistance Test,per FBC, TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201-94 -5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6)Forced Entry Test,per FBC 2411.3.2.1, and TAS 202-94 along with marked-up drawings and installation diagram of an aluminum single hung window,prepared by Fenestration Testing Laboratory, Inc.,Test Report No. FTL-18-7835.1, dated 04/03/18, signed and sealed by Idalmis Ortega,P.E. 2. Test reports on: 1)Air Infiltration Test, per FBC, TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC, TAS 202-94 3) Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC 2411.3.2.1, and TAS 202-94 window,prepared by Fenestration Testing Laboratory, Inc.,Test Reports No. FTL-18-7835.2, dated 05/04/18, signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 61h Edition(2017), dated 04/23/18,prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). Manuelrez Product ContrExa finer NOA No. -0 30.06 Expiration Date: August 23,2023 Approval Date: August 23,2018 E-1 � 1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/18/18, expiring on 07/08/19. 2. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 12/28/17, expiring on 07/04/23. F. STATEMENTS 1. Statement letter of conformance to FBC 6th Edition (2017), dated April 24, 2018, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated April 24, 2018, issued by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. 3. Proposal No. 18-0005R issued by the Product Control Section, dated 01/16/18, signed by Manuel Perez, P.E G. OTHERS 1. None. Manuel er .E. Product Control E a ner NOA No. 18-0 30.06 Expiration Date: August 23,2023 Approval Date: August 23,2018 E-2 SERIES SH7700A IMPACT RESISTANT SINGLE HUNG WINDOW 7-13116"MAX.O.0/., DESIGN PRESSURE RATING IMPACT RATING 1)THIS PRODUCT HAS BEEN DESIGNED&TESTED TO COMPLY WITH THE REQUIREMENTS OF 18-316"MAX. VARIES PER GLASS TYPE, LARGE&SMALL MISSILE THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ). \ SEE SHEETS 2-5 IMPACT RESISTANT 2)SHUTTERS ARE NOT REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS.FOR INSULATED GLASS INSTALLATIONS ABOVE 30'IN THE HVHZ,THE OUTBOARD LITE(CAP) MUST BE TEMPERED,USE ONLY GLASS TYPES 3,7,12,13 OR 15. 17.3!4"MAX. 17-314" 52-118"MAX.BUCK WIDTH 3)FOR MASONRY APPLICATIONS IN MIAMI-DADE COUNTY,USE ONLY MIAMI-DADE COUNTY 9-1/2"MAX• (17-1/4"BUCK) MAX. 4-11116"MAX. APPROVED MASONRY ANCHORS.MATERIALS USED FOR ANCHOR EVALUATIONS WERE B.SEE _ O.C. (9"MAX.BUCK) 5"MAX.O.C. Lpproved M cumplyiug With lh> D.SEE I I Fl PER CW.MWIC% SOUTHERN PINE,ASTM C90 CONCRETE MASONRY UNITS AND CONCRETE WITH MIN.KSI SHEETS s&9 SHEET 10 Fl tPER ANCHOR TYPE. ANA.SEEC,SEE NamJUudc Prod SHEET 10 4)ALL WOOD BUCKS LESS THAN 1-1/2"THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. SHEETS I / 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLYTO SUBSTRATE.WOOD / BUCKS DEPICTED AS ZX ARE 1-1/2"THICK OR GREATER.1X AND 2X BUCKS(WHEN USED) EQUALLY I I SHALL BE DESIGNED AND SECURED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. SPACED ORS PER WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER,(EOR) ANCH OR ARCHITECT OF RECORD,(AOR). TABLES s 87 17-3116"MAX.O.C. 0 I I/ t 84" O I I 83' c 5)ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR T MAX. MAX. STUCCO.USE ANCHORS OF SUFFICIENT LENGTH TO ACHIEVE REQUIRED MIN.EMBEDMENT. ' 12-1116"MAX.O.C. TO BUCK a INSTALLATION ANCHORS SHOULD BE SEALED.OVERALL SEALING 8 FLASHING STRATEGY X i i 4 r TIP X i !-1 r HEIGHT FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND —Ti" HEIGHT THE SCOPE OF THESE INSTRUCTIONS. EQUALLY SPACED ANCHORS PER I 13-5116"MAX.O.C. m 6)114"MAX.SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS TABLES 6 87 I / 5"MAX I w z 1 NOT FLUSH TO THE SUBSTRATE.USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. ;�- L D.C. I / C > w C3 9-1/2"MAX. Fr 7)DESIGN PRESSURES: (9"MAX.BUCK) t C] o o � A.NEGATIVE DESIGN LOADS BASED ON STRUCTURAL&CYCLE TESTING AND GLASS PER A N z a1oD Of Q' ASTM E1300. 1 m O B.POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE,STRUCTURAL&CYCLE T NO ANCHORS AT SILL p —_ / 0 M wa' Z Z TESTING AND GLASS PER ASTM E1300. T B C.DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN,ASD. —�-I 53-118"MAX.TIP TO TIP WIDTH1"WEEP NOTCH 4-11116"MAX. �1'WEEP NOTCH Z LL m i ' P AT EACH END AT EACH END v r 8)THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS FLANGE FRAME ELEVATION FOR TYP.FIN FRAME SHOWN WITH w wLj U 00 ®� Mo. CORRESPONDING TO THE REQUIRED DESIGN PRESSURE.THE 33-1/3%RES STRESS INCREASE ELEVATION FOR TYP. _ m a Z rs< HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT.THE 1.6 LOAD DURATION FACTOR SHOWN WITH EQUAL-LITE CONFIGURATION EQUAL-LITE CONFIGURATION 0 J w Q sma WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD.ANCHORS THAT COME INTO o. O o Z CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE TABLE 1:ALLOWABLE GLASS TYPES USER INSTRUCTIONS: " — FLORIDA BUILDING CODE FOR CORROSION RESISTANCE. Glass OP Description(Listed from Exterior to Interior) Table# 1)DETERMINETHE SITE SPECIFIC,WINDOW OPENING'S DESIGN Z W LL aO 9)METAL SUBSTRATE TO MEET MIN.STRENGTH AND THICKNESS REQUIREMENTS PER Type PRESSURE REQUIREMENT FROM ASCE T CURRENT FLORIDA BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING 1 1/8"AN,.090"PVB,1/8"AN 2 = W JURISDICTION. 2 13116"LIG:1/8"AN CAP,AIRSPACE,118"AN,.090"PVB,1/8"AN 2 2)KNOWING YOUR GLAZING OPTION(TABLE 1),WINDOW ® J c6 V) 10 REFERENCES:TEST REPORTS FTL 18-7835.1 818-7835.2;ELCO ULTRACON NOA;ELCO 3 13116"LIG:1/8"TP CAP,AIRSPACE,1/8"AN,.090"PVB,1/8"AN 3 CONFIGURATION AND SIZE,DETERMINE YOUR WINDOWS DESIGN Z F- C laays 4 PRESSURE FROM TABLES 2-5.IT MUST EQUAL OR EXCEED THE CRETEFLEX NOA;NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 4 1/8"HS,.090"PVB,1/8"HS DESIGN PRESSURE REQUIREMENT FOR THE WINDOW OPENING to Z ANSI/AF&PA NDS&ALUMINUM DESIGN MANUAL 5 3116"AN,.090"PVB,3116"AN 4 OBTAINED IN STEP 1. a � J 6 13116"LIG:3116"AN CAP,AIRSPACE,118"AN,.090"PVB,1/8"AN 4 O Z Q o 11)APPLICABLE EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL. 3)DETERMINE 7HE ANCHOR QUANTITY FROM TABLES 6&7. r Of t` 7 13116"LIG:3116"TP CAP,AIRSPACE,1/8"AN,.090"PVB,VW AN 4 w Z 2 SH CONFIGURATIONS AND SHAPES 8 3/16"AN,.090"SG,3/16"AN 5 4)INSTALL AS PER SHEET 7 FOR FLANGE INSTALLATION,SHEET 8 O J w W FIGURE A:ALLOWABLE SA � � SH WIDTH �--• H WIDTH � 9 3116"HS,.090"SG,3/16"HS 5 FOR EQUAL LEG INSTALLATION OR SHEET FOR INTEGRAL FIN WIDTH Q U _ __ 10 13/16"LIG:1/8"AN CAP,AIRSPACE,1/8"HS,.090"SG,1/8"HS 5 INSTALLATION. a1111 rosap saua5 TI I T 11 13!16"LIG:1/8"AN CAP,AIRSPACE,3/16"AN,.090"SG,3116"AN 5 NOTE:DESIGN PRESSURE RATING DETERMINATION IS THE SAME 11111 I I I 1 I 1/17 �- t- 12 13116"LIG:118"TP CAP,AIRSPACE,118"HS,.090"SG,118"HS 5 PROCESS FOR ALL FRAME TYPES(FLANGE,INTEGRAL FIN OR ���� NY LYN/y 0........, 77 13 13116"LIG:1/8"TP CAP,AIRSPACE,3116"AN,.090"SG,3116"AN 5 EQUAL LEGIBOX). `r, /, L7 L9 C9 / 14 13116"LIG:3116"AN CAP,AIRSPACE, 1/8"HS,.090"SG,1/8"HS 5 `��:•'VICENSF'•., 15 13/16"LIG:3116"TP CAP,AIRSPACE, 1/8"HS,.090"SG,1/8"HS 5 Q'. ,� No.58705 1 / 1 // SG=KURARAY SENTRYGLAS®INTERLAYER BY GENERAL NOTES................................................. w 1 KURARAY AMERICA,INC. ELEVATIONS.........................................................1 J :•�` RECTANGULAR RADIUS-TOP RECTANGULAR CODES/STANDARDS USED: PVB=KURARAY TROSIFOLO PVB INTERLAYER BY DESIGN PRESSURES/GLAZING DETAILS........2-4 r y �O O WITH EQUAL WITH PROVIEW WITH CUSTOM •2017 FLORIDA BUILDING CODE FBC,6TH EDITION O ST TE OF ( ) KURARAY AMERICA,INC. ANCHOR QUANTITIES..........................................5-6 i S p '•_�� LITE SASH SASH SASH ASTM E1300-09 AN=ANNEALED INSTALLATION,FLANGE......................................7 �C�s '••�ORID,.•'�\ •ANSI/AF&PA NDS-2015 FOR WOOD CONSTRUCTION HS=HEAT-STRENGTHENED INSTALLATION,EQUAL LEG.................................8 777 S'/O•. 0 " ALL SHAPES WITH ALL SASH CONFIGURATIONS ARE APPROVED.SHAPES -ALUMINUM DESIGN MANUAL,ADM-2015 TP=TEMPERED INSTALLATION,INTEGRAL FIN............................9 7//1j NAL 0" MAY BE USED BY INSCRIBING THE SHAPE IN A BLOCK AND OBTAINING -AISI S100-12 EXTRUSION PROFILES.........................................10 DESIGN PRESSURES AND ANCHORAGE FOR THAT BLOCK SIZE FROM THE •AISC 360-10 ASSEMBLY&PARTS LIST....................................11 A.LYNN MILLER,P.E. P.E.#58705 TABLES ON THE FOLLOWING SHEETS. TABLE 2: Bottom Sash Sash Height Design Pressure(lbslfe)for Glass Types 1&2 Description Range(in) Tip to Tp Width (or Given Range 16' 25" 33" 37' 41" 45" 49" 53.1/8" 24" Equal-lite 12.464 +65.0 410.0 +65.0 -80.0 +65.0 -80.0 +65.0 -BO.O +65.0 430.0 +65.0 -60.0 +65.0 -80.0 +65.0 -80.0 Equal-lite 15.964 +65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -8D.0 5/16"NOM. 31" Standard PicAm 12.994-15.953 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 I` GLASS STACK Shortest 12.464-12993 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 480.0 +65,0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 480.0 1-1/8'AN GLASS tppimcd as wmpl)ing with tla Equal-lite 19.652 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 .090"PVB Flori'la )acting Carl Standard PmHew 15.944-19.651 +65.0 -80.0 +65.0 -80.0 +65.0 -80.D +65.0 430.0 +65.0 430.0 +65.D -80.0 +65.0 -80.0 +65.0 430.0 1/8"AN GLASS Date �J 38.3/8" Custom Size 15.131-15.943 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 480.0 30 NDA// + L1laml Dr a Prodnd ontrol Custom Size 14.131-15730 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.D +65.0 .80.0 +65.0 -80.0 +65.0 -60.0 +65.0 430.0 26 Shortest 12464-14.130 +65.0 -80.0 +65.0 480.0 +65.0 -80.0 +65.0 460.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 1I2"NOM. `•- Equal-lite 22964 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 460.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 GLASS BITE Custom Size 20.131-22963 +65.0 -8D.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 EXTERIOR Standard Prcdsw 18.594-20.130 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 *65.0 -80.0 +65.0 -80.0 46' Custom Size 16.131-18.593 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 x((1.0 75 c Custom Size 15.131-16.130 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 $0.0 +65.0 -80.0 +65.0 -80.0 +65.0 410.11 34 Custom Size 14.131-15.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 X0.0 +65.0 •80.0 +65.0 -80.0 +65.0 430.0 Shortest 12.464.14.130 +fi5.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 '0.0 +65.0 -80.0 +85.0 -80.0 +65.0 430.0 GLASS TYPE 1 Equal-lite 24.964 +65.0 •80.0 .65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 Custom Size 22.131-24.963 +65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Standard Ptodew 20.194-22130 +65.0 -BO.0 +65.0 -80.0 +65.0 480.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 W 13 °D 2 E 49" Custom Size 18.131-20.193 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -8D.0 +65.0 -80.0 +65.0 -80.0 �_ e Custom Size 16.131-18.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 fY w o � •„aa Custom Size 14.131-16.130 +65.0 -80.0 +65.0 430.0 +65.0 480.0 +65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.6 O 1. O c' u7 Shortest 12464-14.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +85.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 •75.1 13116"NOM. N a w a1a0 Of y Equal41te 25.777 +65.0 -80.0 +65.0 430.0 +65.0 430.0 +65.0 4;0.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 I GLASS STACK m � Z = Custom Size 24.131-25.776 +65.0 .80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 .090"PVB O J p a y W O o Standard Pm%iew 20.844-24.130 +65.0 430.0 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 *65.0 -80.0 +65.0 -80.0 +65.0 $0.0 AIRSPACE Z IL '7 c� r F 50.5!8° Custom Size 20.131-20.843 +65.0 -80.0 +65.0 480.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 480.0 +65.0 -80.0 118"AN GLASS =W it `J' 7e 1/8"AN GLASS U U o Custom Size 18.131-20.130 +65.0 -80.0 +65.0 430.0 +65.0 430.0 +65,0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 W- 03 a J aMa10 'oN Custom Size %131-18.130 +65.0 -80.0 +65.0 460.0 +65.0 480.0 +65.0 -80.0 +65.0 -80.0 +MO -80.0 +65.0 -80.0 +65.0 -77.6 31 75 F W � a Q `SMO Cullom Size 14.131-16.130 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 +65.0 -110.0 +65.0 -80.0 +65.0 -80.0 +fi5.0 -80.0 +65.0 -75.1 o- ~ Shortest 12.464-14.130 +65.0 -00.0 +65.0 -60.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -73.9 5®OR 511 12"NOM. Z °� Z Equal4ite 31.964 +65.0 -80.0 +65.0 -80.0 +65.0 480.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 480.0 +65.0 -80.0 EXTERIOR GLASS BITE (7 `-• Custom Size 28.131•31.963 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 *65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.6 Z I.L. Standard Prouew 25.794-28.130 +65.0 -80.0 +65.0 •80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 +65.0 -80.0 +65.0 -73.9 7 O 2 N Custom Size 24.131-25.793 +65.0 -80.0 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -72.7 63" Custom Size 22131-24.130 +65.0 -60.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -78.8 +65.0 -70.5 �5�p8r� 70.73 KAI C9Custom Size 20.131-22130 +65.0 -80.0 +65.0 430.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.1 +65.0 -68.4 35 R 511 ZCustom Size 18.131-20.130 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 -800 +65.0 -80.0 +65.0 •80.0 +65.0 -75.4 +65.0 -66.5 GLASS TYPE 2Custom Size 16.131-18.130 +65.0 410.0 +65.0 -80.0 +65.0 430.0 +65.0 •800 +.165.0 +64.7 fi4.7 Shortest 13.194'-16.130 +65.0 -80.0 +650 -80.0 +65.0 4300 +65.0 -80.0 +65.0 -75.9 +65.0 -71.8 +65.0 -68.2 +623 •G2.3 J p Equel4ile 38.464 +65.0 $0.0 +65.0 •80.0 +65.0 430.0 +65.0 460.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -73.9 Custom Size 36.131-30.463 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 460.0 +65.0 -60.0 +65.0 •79.8 +65.0 -71.6 Custom Sae 34.131-36.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -77.9 +65.0 -69.476' Strdard PoMm 30.994-34.130 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -75.4 +65.0 X6.5 Custom Size 30.131-30.993 +65.0 480.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -78.9 +65.0 -74.6 +65.0 465.6 Custom Size 28.131-30.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -79.1 +65.0 -763 +65.0 -71.9 +63.8 -63.8 `�1NY LYN/y Shortest 26.194'-28.130 +65.0 480.0 +65.0 •80.0 +65.0 -80.0 +65.0 -8D.0 +65.0 -75.9 +65.0 •71.0 +65.0 -68.2 +623 X23 �� Q i, Equal-lite 42.464 +65.0 480.0 +65.0 430.0 +65.0 480.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -77.9 +65.0 469.4 '��•'•�,10EN81••. 114° Custom Size 38.131-42463 +65.0 -80.0 +65.0 -00.0 +65.0 -80.0 +65.0 -BD.O +65.0 -80.0 +65.0 •78.9 +65.0 -74.6 +65.0 -65.6 Q°;' '•,� Standard Pro'+_ 34.194•-38.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.9 +65.0 -71.8 +65.0 -68.2 +62,3 -62.3 �•; NO.58705 •MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 -_ MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 O ST E �(l/ MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 s`/S/ONAL E�G�` 1)TIP TO TIP DIMENSIONS SHOWN.FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1°FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. AN=ANNEALED ///f I lilt l t` 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXT AVAILABLE SIZE. TP=TEMPERED 3)FOR RADIUS TOP WINDOWS,FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. A LYNN MILLER,P.E. 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF+65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. HS=HEAT STRENGTHENED P,E.0 58705 TABLE 3: Bottom Sash sash Height fqr Given Range RanDesign Pressure(lbslfe)for Glass Type 3 Descriptionage Range(in) 71p to Tip Width 18" 1 25" 33° 1 3T' 41" 45" 49' 53-116" 13116" 24" Equal-lite 12464 +65.0 -80.0 +65.0 -80.0 +65.0 -00.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +55.0 -80.0 +65.0 -80.0 �I GLASS NOM. GLASS STACK Equal-lite 15.964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 1 -80.0 1+65.0 -80.0 +65.0 -80.0 +65.0 -80.0 31" Standard Preview 12994-15.963 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 .090"PVB AIRSPACE Shortest 12454-12.993 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/8"TP GLASS 4pproved m complying with ttr:. Equal-lite 19.652 +65,0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 +65.0 -80.0 1/8"AN GLASS F1o13 8pldlegC Standard Prouew 15.944-19.651 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 .80.0 +65.0 A0.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 31 75 Dale 38-3/8" Custom Size 15.131-15.943 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 $0..0 +65.0 X0.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 'q0 ° Custom Size 14.131-15.130 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 tdgmi Dade 1'mduct trot 5®OR 5B 112"NOM.BIT Shortest 12.464-14.130 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 430..0 +65.0 -80.0 +65.0 •80.0 +65.0 430.0 +65.0 -80.0 GLASS BITE ••.Equal-lite 22954 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 '-80.0 +65.0 -8D.0 +65.0 -80.0 IXTERIOR Custom Size 20.131-22963 +65.0 -80.0 +65.0 -60.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +6.5.0 -80.0 +65.0 430.0 a Standard Pm%Am 18.594-20.130 +65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 45' Custom Size 16.131-18.593 +65.0 -80.0 +65.0 •80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 430.0 70-73 Custom Size 15.131-.16.130 +65.0 -80.0 +65.0 430.0 +65.0 -80,0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -B0.0 +65.0 -80.0 35 0R 356 .19 Custom Size 14.131-15.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -B0.0 +65.0 -80.0 GLASS TYPE 3 12 Shortest 12464-14.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 1.80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Equal-lite 24.964 +65.0 •80.0 +65.0 "-80.0 +65.0 -80.0 +65.0 -80.0 +65.0 1-80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 Custom Size 22.131-24.963[+65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Standard Protim 20.194-22130 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 430.0 +65.0 -60.0 +65.0 -80.0 LU z � 49' Custom Size 18.131-81.193 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 16.131-18.130 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 w O 0 '^1N Custom Size 14.131-16.130 -80.0 +65.0 •80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 O O r Shortest 12464-14.130 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 N iw M. Equal-lite 25.777 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 *65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Q A n Z oCustom Size 24.131-25.776 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 •80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 O J O y W O o Standard Prolew 20.844-24.130 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.1) -80.0 +65.0 -80.0 +65.0 -80.0 Z LL (D mi ' t-- Custom `Custom Size 20.131-20.843 +65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 =111 `- o rc -J 46 I` IE 50.518° U U oro Custom Sae 18.131-20.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 W- 00 < � uMe.O oN Custom Size 16.131-18-130 +65.0 430.0 +65.0 430.0 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 F-'LU u Q J.NO Custom Size 14.131-16.130 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 r co Shortest 12464-14.130 +65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 1-80.0 1 0, Z _ Equal-lite 31.954 +55.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 C0 Custom Size 28.131-31.963 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 *65.0 -80.0 ? LL O Standard ProtJew 25.794-28.130 +65.0 •80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 = M Custom Size 24.131-25.793 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 mLu 63" Custom Size 22131-24.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 ® J Custom Size 21.131.22.130 +65.0 .80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 .+650 -80.0 +65.0 -78.0 j� 11145 Custom Size 18.131-20.130 +65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 +65.0 -80.0 *65.0 -75.8 CO Z Custom Size 16.131-18.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -73.8 Shotes[ 13.194'-16.130 +65.0 43D.0 +65.0 430.0 +65.0 •80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.7 +65.0 -71.0 O J 0 f Z lb 1� Equal4ite 38.464 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 l-77.7 +65'0 80.0 +65.0 -80.0 2 n Custom Size 36.131-38.463 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 80.0 +65.0 -60.0 U I-- 2 Custom Size 34.131-36.130 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 80.0 +65.0 -79.1 J d Q O 7G Standard PrW- 30.994-34.130 +65.0 430.0 +65.0 430.0 +65.0 430.0 +65.0 430.0 +65.0 430.0 +65.0 430.0 80.0 +65.0 -75.8 1112 -�sa0 sa�a5 Custom Size 30.131-30.993 +65.0 430.0 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 410.0 -80.0 -+65.0 -74.8Custom Sae 28.131-30.130 +65.0 -80.0 +65.0 430.0 +65.0 430..0 +65.0 430.0 +65.0. 430.0 +65.0 430.0 -80.0 +65.0 -727Shortest 26.194•-28.130 +65.0 430.0 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 •80.0 -77.7 +65.0 -71.0 �� tJY LYNAIEquel4ite 42.464 +65.0 430.0 +65,0 -80.0 +65.0 430.0 +65.0 •80.0 +65.0 •80.0 430.0 +65.0 -79.1 \ ' c84" Custom Size 38.131-42463 +65.0 430.0 +65.0430.0 +65.0 -80.0 +65.0 430.0 +65.0 410.0 +65.0 -80.0 -80.0 +65.0 -74.8Standard P.4- 34.194'-38.130 +65.0 430.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 *65.0 430.0 +65.0 -80.0 -77.7 +65.0 -71.0 `* No.58705 *= •MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 '0 ':'` IT IAS MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIPTOTIP HEIGHT-49.806 Op^MINIMUM SASH HEIGHT FOR INTEGRAL FINAND EQUAL LEG,RADIUSTOPWINDOWS IS:BUCK HEIGHT-48.806 �O TE OF [(/�` •. 1)TIP TO TIP DIMENSIONS SHOWN.FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 7�7/S 10 1) t,%\\` 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXT AVAILABLE SIZE. AN=ANNEALED TP=TEMPERED 3)FOR RADIUS TOP WINDOWS,FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FR WITHIN. A.LYNN MILLER,P.E. 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF+65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. HS=HEAT STRENGTHENED P,E.#58705 TABLE 4: TABLE 5: Design Pressure for Glass Ty es 8-15 Design Pressure(Ibslfiz)for Glass Types 4-7 5/76"NOM. 3/16"AN GLASS 3116"HS GLASS 9 -�I .080"SG .090"SG GLASS STACK Bottom Sash TIP To TIP Bottom Sash Tp TO Tp Sash Heigh Width 3116"A GLASS 3/16"H GLASS Sash Height 118"HS GLASS DesOdplion 30 30 Description Width .0901,PVB Range(In) Range(in) for Ghen Range 53-7/9" for Ghen Range 53-118". 1/GLASS 26 26 24" Equal-lite 12464 +65.0 BO.D 30 24" EquaFlde 12.484 +80.0 -110.0 12"NOM. 12°NOM. EquaHile 15.884 +65.0 -80.0- 26 Equal-lite 15.964 +80.0 -110.0 EXTERIOR GLASS BITE EXTERIOR GLASS BITE 31' Standard PmNeW 12.994-15.963 +65.0 -80.0 1121,NOM. 31" Standard Pm14ew 12994-15.963 +80.0 -110.0 a a EXrERIOR GLASS BITE Shortest 12464-IZ993 +60.0 -110.0 74 Shortest •12.464-12993 +65.0 80.0 74 Shortest Equal-lite 19.852 +65.0 80.0 a Equal4ile 19.652 +60.0 -110.0 34 34 spproved az comNYrR81dt9 tiaa 74 Standard Pro i w 15.944-19.651 +80.0 -110.0 GLASS TYPE 8 GLASS TYPE 9 1 Ilk Bidding Standard Pm�7Bw 15.944-19.651 +65.0 80.0 Bate 38818° Custom Size 15.131-15.943 +80.0 -110.0 f(OAtl 353/8" Custom Size 15.131-15.943 +65.0 80.0 GLASS TYPE 4 13116'NOM. �_ 13116"NOM. 611 qd Dade Product Cantrdl Cuslam Size 14.131-15.130 +65.0 80.0 Custom Size 14.131-15.730 +80.0 -110.0 Shortest 12464-14.130 +80.0 -110.0 If- GLASS STACK GLASS STACK Shortest 12464-14.130 +65.0 80.0 7/16°NOM. .090"SG .090'SG !•. Equal-lite 22964 +85.0 80.0 GLASS STACK EquaHile 22.964 +80.0 -110.0 AIRSPACE AIRSPACE Custom Size 20.131-22963 +65.0 -80.0 Custom Size 20.131-22963 +80.0 -110.0 iB'AN GLA 118°HS GLASS 1/8°AN GLASS 3116"AN GLASS 3/I6"AN GLASS Standard Pmuew 18.594-20.130 +80.0 410.0 31 74 31 74 Standard PmUew 18.594-20.130 +65.0 80.0 .090"PVB 45" Custom Size 16.131-1B.593 +65.0 80.0 30 3116'T GLASS 45° Cust-Size 16.131-'18.593 +80.0 -110.0 TOR 5 OR 5 Custom Size 15.131-16.130 +65,0 80.0 27 jl Custom Size 15.131-16.130 +80.0 -110.0 ® 12"NOM. ® 12"NOM. Custom SIZE 14.131-15.130 +65.0 -80.0 12°NOM. Custom Size 14.131-15.130 +80.0 -110.0 EXTERIOR GLASS BITE EXTERIOR GLASS BITE Shortest 12.464.14.130 +65.0 -80.0 EXTERIOR GLASS BITE Shortest 12464-14.130 +80.0 -110.0 a a a EquaHile 24.964 +65.0 -80.0 Equal-lite 24.964 +80.0 •110.0 70-73 ®OR 5 70.73 Custom Size 22.131-24.963 +65.0 80.0 74 Custom Size 22131-24.963 +80.0 -110.0 5®OR 5 Standard Pmdew 20.194-22130 +80.0 -110.0 GLASS TYPE 10 GLASS TYPE 17 Standard Prodew 20.194-22.130 +65.0 -80.0 � � 49' Custom Size 18.131-20.193 +65.0 80.0 GLASS TYPE 5 49" Custom Size 18.131-20.193 +80.0 410.0 W K U) Custom Size 18.131•18.130 *65.0 -80.0 Custom Size 16.131-18.130 +80.0 -110.0 w O 13!16°NOM. 13116'NOM. '^a21 Custom Size 14.131-16.130 +65.0 80.0 •--� i.�. 13/16"NOM. Custom Size 14131-16130. . +80.0 -110.0 �- GLASS STACK �- GLASS STACK 0 o 0 Shortest 12464-14.130 +65.0 80.0 I I GLASS STACK Shortest 12484-14.130 +80.0 -110.0 .090"SG .090°SG } �� a100 O m AIRSPACE AIRSPACE c Ir Q Equal-Tile 25.777 +65.0 BD.O .090'PVB 'p EquaHile 25.777 +80.0 -110.0 U N z O i AIRSPACE = Custom Size 24.131-25.778 +80.0 -110.0. 118'TP GLASS 118'HS GLASS 1/8'TP GLASS 3116"AN GLASS 0 F w U7 Z Custom Size 24.131-25.776 +65.0 80.0 F 3/16'AN GLA 7/8"AN GLASS o Standard Plouew 20.844-24.130 +80.0 -110.0 31 74 31 74 Q J p a rn W O Standard PrcMm 20.844-24.130 +65.0 80.0 LL Custom Size 20.131•20.&13 +65.0 80.0 31 74 F 50518" Cuslan Size 20.137-20.843 +80.0 -110.0 ®OR 5B 12"NOM. ®OR 5 12'NOM. =I1J o X I= 50-S1B' atom Size 18.131-20.130 +65.0 80.0 CualOm Size 78.131-20.130 +80.0 -710.0 GLASS SITE GLASS BRE 1 EXTERIOR EXTERIOR U L V O o Custom Size 18.131-18.730 +65.0 80.0 ®OR SB 12'NOM. Custom Size 16.131-18.130 +80.0 -110.0 a a W Z 00 i< J uM 0 ON Custom Size 14.131-16.130 +65.0 80.0 EXTERIOR GLASS BITE Custom Size 14.131-16.130 +80.0 -110.0 W .-. 0110 Shortest 12.464-14.130 +65.0 80.0 a Shortest 72464-14.130 +80,0 -170.0 35 OR 5 70-7J ®OR 5 70.73 ^O a V (p Equal-lite 31.964 +65.0 •80.0 70-73 Equal-lite 31.964 +60.0 -110.0 GLASS TYPE 12 GLASS TYPE 13 r Z Z Custom Size 28.131-31.963 +65.0 80.0 5@OR 5 Custom Size 28.131•31.963 +800 -110.0 (� Standard Pmvlew 25.794-28.730 +65.0 80.0 GLASS TYPE 6 standard PmNew 25.794-28.130 +80.0 -110.o Z LL Custom Size 24.131-25.793 +80,0 -110.0 Imo, 13116"NOM. Lam. 13/16"NOM. Custom Size 24.131-25.793 +65.0 80.0 I GLASS STACK I GLASS STACK = V' 63" Custom Size 22131-24130 +65.0 80.0 I 13!16"NOM. 63" Custom Size 22131-24.130 +80.0 -110.0 .090"SG .090"SG ® m W CD Custom Size 20.131-22 730 +65.0 -80.0 r~ GLASS STACK Custom Size 20.131-22130 +80.0 -110.0 AIRSPACE AIRSPACE J AIRSPACE .090"PVB Custom Size 18.131-20.130 +80.0 -110.0 3118"AN GLAS 1!8°HS GLASS 3/16"TP GLASS 1/6"HS GLASS # laay5 Custom Size 18.131-20.130 +65.0 80.0 Z Custom Size 16.731-16.130 +65.0 80.0 3116"TP GLASS 118•AN GLASS Custom Size 16.131-18.130 +8D.0 -110.0 31CGLASS S1 74 �j fn Shortest 13.194'-16.130 +65.0 80.0 Shadest 13.184"-16.130 +8D.0 -110.0 Q Q 31 Equal-liter 38.464 +65.0 80.0 74 Equal411a 38.464 +80.0 -110.0 25 DR 5B OR 5 72"NOM. p J CUsIOm Size 36.131-38.483 +85.0 80.0 ®OR 5 12'NOM. Custom Size 36.131-38.463 +80.0 -110.0 tRIOq E EXTERIOR GLASS BITE 34.131-36.130 +65.0 80.0 E%T GLASS BITE Custom Size 34.131-36.130 +80.0 -110.0 a V76' SlerWard PrOtlew 30.994-34.130 +65.0 80.0 78' Standard Prauew 30.994-34.130 +80.0 -110.0 30.131-30.993 +65.0 80.0 Custom ze 30131-30.993 +80.0 5@OR 5 70.73 Q p ®Oft 5 Custom Slze 28.131-30.130 +65.0 80.0 70-73 Custom Size 28.131-30.130 +80.0 -110.0 GLASS TYPE 14 GLASS TYPE 75 a17f1 asap saua5 OR 5 Shpdest 28.194'•28.130 +65.0 80.0 GLASS TYPE? Shortest 26.794'-28.130 +60.0 -110.0 `tt Equal-lite 42464 +65.0 BD.O Equal-lite 4z4sa +eo.o -170.0 `��` aNY LYN/V 84' Custom Size 38.731-42.463 +65.0 80.0 84° Cullom Size 38.131-42483 +80.0 -110.0 \'��.•'.tGENSF •/�C Standard PloAew 34.194'-38.730 +65.0 80.0 Standard PlrnAew 34.194'-38.130 +80.0 •110.0 Qa;' •.1<`��� •MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIPTO TIP HEIGHT-49.391 =*; No.58705 = MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-46.391 - - MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.606 MATE �0�'. F 1)TIP TO TIP DIMENSIONS SHOWN.FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. SI NAL W `\` 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXT AVAILABLE SIZE. AN=ANNEALED TP=TEMPERED 3)FOR RADIUS TOP WINDOWS,FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. A.LYNN MILLER,P.E. 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF-65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. HS=HEAT STRENGTHENED REA 58705 TABLES: Anchor Quantities Required for Tip to Tip width "Through-Frame"Installation ilamb 25" 33" 37° 41" 45" 49" 53.1/8° Us In Glass T es 1-7 Jamb Jamb Jamb �1-b Jsmb Jamb Jamb KBottom Sash SashHeighOescrtptionfor Given Range Rang ") 8 B - 8 TABLE 6B: a a m" a m a m 24" Equal-lite 12.464 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 Glass Description(Listed from Exterior to Interior) Equal-lite 15.964 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 Type Approved as rampt)'iog l Ith tb 31" Standard Pror4 w 12.994-15.963 2 2 1 z 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 1 1/8-AN,.090"PVB,1/5'AN Florid B'ddln9C Shortest 12464-12.993 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 13/16"LIG:1/8"AN CAP,AIRSPACE,118"AN,.090"PVB,118"AN Dula (p Equal-lite 19.652 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 13116"LIG:1/8"TP CAP,AIRSPACE,1/8"AN,.090"PVB,116"AN ------- anrProdud Control Stdard Prouew 15.944-19.651 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 4 1/8"HS,.090"PVB,1/8"HS 38318" Custom size 15.131-16.943 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 5 3/15'AN,.090"PVB,3116"AN - Custom Size 114.131-15.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 6 13/16"UG:3/16"AN CAP,AIRSPACE,118"AN,.090"PVB,1/8"AN Shortest 12.464-14.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 7 13/16"UG:3/16"TP CAP,AIRSPACE,1/8"AN,.090"PVB,1/8"AN EquaHite 22.964 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 20.131-22.953 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 _ Standard Proim 18.594-20.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 45° Custom Size 16.131-18.593 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 15.131-16.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 14.131-16.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Shortest 12.464•14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2_ 2 3 2 2 3 2 2 3 2 2 W Equalaite 24.964 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 z o 0 as Custom Size 22131-24.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 w. O Standard ProNew 20.194-22.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 D O U) c.. 49" Custom Size 18.131-20.193 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 r 4140 o O Q Custom Size 14.131-16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 D Cl) cc, Z Z O J p a'rm- W O Shortest 12.464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Z LL °i EquaHite 25.777 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 o t9 i LL g Custom Size 24.131-25.776 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 W U 0 ®� J ^`e�0 ,oN F Standard Prrniew 20.844-24.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 F-W 50-518- 20.130 Custom Size 20.131-20.843 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 0) 1-- F Custom SIZE 18.131-20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2, Z O Z Custom size 16.131-18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 W J e Custom Sim 14.131-16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Z m LL Shortest 12464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 5 )¢.. O LD Equal-lite 31.964 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 m = } Custom Size 28.131-31.963 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 0 m J H Standard Prc iew 25.794-28.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 3 2 # O Z ., laagS Custom Size 24.131-25.793 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3'2 2 3 2 2 83" Custom Size 22131-24.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Custom Size 20.131•22.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2[33 2 2 3 2 2 LL 7 O O Custom Size 18.131-20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 2 2 3 2 2 f; Z O Custom Size 16.131-18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 2 2 3 2 2 w U =Shortest 13.194'-16.130 4 2 1 4 2 1 4 2 1 4 2 2 4 2 2 4 2 2 2 2 4 2 2 J Z U) Equal-lite 38.464 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 2 3 3 2 Q QCustom Size 35.131-38.4633 3 1 3 3 1 3 3 1 3 3 2 3' 3 2 3 3 2 3 2 3 3 2a/1� 'asapCustomSize 34.131-36.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 2 3 3 2 76" StandardProiew 30.994-34.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 1 31 21 31 31 2 �``�711Y1LYN N,� Custom Size 30.131-30.993 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 `�� �Q*...... Custom Size 28.131-30.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 �.•' _ICENSF'•..(� Shortest 26.194•-28.130 4 2 1 4 2 1 4 2 1 M42 2 2 4 2 2 4 2 2 4 3 2 Equal-lite 42.464 3 a 1 3 4 1 3 4 1 a 2 3 4 z 3 4 2 3 a z 1)TIP TO TIP DIMENSIONS SHOWN.FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS, No.58705 r Custom Size 36.131-62.463 3 4 1 3 4 1 3 4 1 a 2 3 4 2 3 4 2 3 a 2SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE _WINDOWSIZE. Standard Proiew 34.194'-38.1304 3 1 4 3 1 4 3 1 3 2 4 3 2 4 3 2 4 3 2 --D •MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXTAVAILABLE SIZE. ?J '.• (V MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 Oma'. VAT01, ((�` MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIPTO TIP HEIGHT-49.806 3)FOR RADIUS TOP WINDOWS,FINDTHE SMALLEST WINDOW SIZE IN THE TABLE ABOVE �s .,F(OR1DP,•' MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. % S+ 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TOA MAXIMUM POSITIVE DESIGN /ANAL 0,��`` PRESSURE OF+65 PER NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. A.LYNN MILLER,P.E. P.E.#58705 TABLE 7: Anchor Quantities Required for Tip to Tip Width "Through-Frame"Installation 18" 25" 33" 1[2 41" 45" 49" 53-118" usln Glass T es 8-15 Jamb Jamb Jamb JaJamb Jamb Jamb Jamb Bottom Sash z rc ¢ W.w ¢ w � K " W m Sash Height d m u ki o Description = 3e = _for Giten Range Range(in) _ _ 8' _ $¢ to ¢ m ¢ m ¢ ¢ ra ¢ m ¢ m ¢ toTABLE 78: 24" EquaNite 12.464 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 Glass edvscoMpyf19g1$1bM Equal-iite 75.964 1 2 1 1 2 1 1 2 1 i z z 1 2 2 1 2 z t 2 2 Type Description(Listed from Exterior to Interior) Ato�B)+11finB brie31" Standard Protlew 12.994.15.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 3 2 2 2 8 3116"AN,.090"SG,3/16"ANte aShortest 12.464-12.993 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 AirEqual-Ills 19.652 z z 1 z 2 1 2 z 1 2 z 2 z z z z 2 2 2 2 2 9 3116"HS,.090"SG,3/16"HS SAf tial ePredLe! nStandard Promm 15.944-19.651 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 10 13116"LIG:118"AN CAP,AIRSPACE,178"HS,.090"SG,1/8"HS 38-ale' Custom size 15.737-75.943 2 2 1 2 2 7 2 2 7 2 2 2 2 2 2 2 2 2 2 2 211 13/16"LIG:118"AN CAP,AIRSPACE,3116"AN,.090"SG,3116"ANCustom Size 14.131-15.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 12 13116"LIG:1/8"TP CAP,AIRSPACE,1/8"HS,.090"SG,1/8HSShortest 12464-14.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 13 13/16"LIG:118"TP CAP,AIRSPACE,3116"AN,.090"SG,3116"AN Equal-lite 22.964 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 2 14 13/16'LIG:3/16"AN CAP,AIRSPACE, 118"HS,.090"SG,1/8"HS Custom Size 20.131-22.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 2 15 13/16"LIG:3116"TP CAP,AIRSPACE, Standard Pro J" 18.594.20.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 45' Custom Size 16.131-18.593 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 Custom Size 15.131-16.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 Custom Size 14.131-15.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 Shortest 12.464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 3 W z rY Equal•lite 24.964 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 Custom Size 22131-24.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 w O O naa D' Standard Prm7ew 20.194-22.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 3 y ro O U) r. 49" Custom Size 18.131-20.193 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 n o- alo0 w Q Custom Size 16.131-18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 3 O r w O Custom Size 14.131-16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 1 a Z p U J O H W O Shortest 12464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 Z LL ms -" Equal4lte 25.777 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 ' r nCustom Size 24.131-25.776 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 W 00 F W C� W ®� J n 'oN Standard Pro�iew 20.844-24.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 3 F-W 'd' 2¢ Q a Dma F 50-5/B' Custom Size 20.131-20.843 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 Custom Size 18.131-20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 3 3 Z .�. o Z Custom Size 16.131-18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 W J a-• Custom Size 14.131-16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 Z m LL Shortest 12.469-74.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 EquaNite 31.964 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 4 3 fO LU } (D Custom Size 28.131-31.963 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 3 3 4 3 ® rn J F- StandardPro�iew 25.794-28.130 3 2 1 3 2 1 3 2 1 3 2 2 3 3 2 3 3 2 3 3 3 3 3 3 ~ Z 1aay5 Custom Size 24.131-25.793 3 2 1 3 2 1 3 2 1 3 2 2 3 3 2 3 3 2 3 3 3 3 3 3 FD 3 W. Custom Size 22 131-24.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 3 2 3 3 3 3 3 3 ¢ CY Custom Size 20.131-22.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 3 3 3 3 3 u- Custom Size 18.137-20.13D 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 4 3 3 O =_ O Z U Custom size 16.137-18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 4 2 3 4 2 3 w U = Shortest 13.194'-16.130 4 2 1 4 2 1 4 2 1 4 2 2 4 2 2 4 2 2 4 2 3 4 2 3 U J Z 1n Equal-lite 38-464 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 4 2 3 4 3 3 4 3 Q Cuslom Size 36.131-38.463 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 4 2 3 4 3 3 4 3 aplJ 'asap sauas Custom Size 34.131.36.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 4 2 3 4 3 3 4 3 76' Standard Custom SizeeW 30.131-0.993 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 4 3 3 4 4 3 `` Y1LYNll7j777i Custom Size 28.131-30.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 4 3 2 4 3 3 4 4 3 \ Shortest 26.194'.28.130 4 2 1 4 2 1 4 2 1 4 2 2 4 3 2 4 3 2 4 3 3 4 3 3 �a'��••'�,tcENSE'••�(���' Eque14i1e 42.464 3 a 1 3 2 1 3 4 1 3 4 2 a a 2 3 4 2 3 a 3 3 5 3 1)TIP TO TIP DIMENSIONS SHOWN.FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS, ' F- 1 Custom Size 38.131-42.463 3 4 1 3 4 1 3 4 1 3 4 2 3 a 2 3 4 2 4 4 3 4 5 3 SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE No.58705 WINDOW SIZE. * •1 1�.- StandardProiew 34.194•-38.130 4 3 1 7-3 1 4 3 1 4 3 2 4 3 2 4 4 2 4 4 3 4 4 3 _ 'MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXT AVAILABLE SIZE. MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT.48.391 3)FOR RADIUS TOP WINDOWS,FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE ��0�.. STT F !(7�� MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. i '•.;°CORIOI'`,•'• \_� MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT.48.806 WHICH �i�s •••••••"' �G`�` 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN '77S 70NAL E��` PRESSURE OF+65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. A LY44 MILLI?d,P.E P.E.#58705 INSTALLATION DETAILS FOR FLANGE FRAMES INSTALLATION OPTION 2 INSTALLATION OPTION 3 INSTALLATION ANCHORED THROUGH FRAME ANCHORED THROUGH FRAME AND 1X OPTION 1 EDGE DISTANCE DIRECTLY INTO CONCRETE'/CMU. BUCKSTRIP INTO CONCRETE/CMU.SEE NOTE 2,THIS SHEET. ANCHOREDTHROUGH r T EMBEDMENT EMBEDMENT FRAME INTO 2X WOOD � 1/4"MAX SHIM 1/4"MAX SHIM FRAME OR BUCKSTRIP. ° EDGE SEE NOTE 2,THIS SHEET. I EMBED. I T 4 SASH VISIBLE 17 ° —{ MENT EDGE " I LIGHT WIDTH � approved na sooe{uylnB wLW llw DISTANCE DISTANCE fulldp/4I;((.EC. 1/4"MAX SHIM 19 FIXED VISIBLE •° x"'m1IDt Pro�uc1 ami L--- — ----1----1 If'� LIGHTWIDTH 1 SEE TABLE "•- NOTE B,FOR 30 18 HEAD TYPE FIXED TYP.ANCHOR TYPE, 44 ° EMBEDMENTAND VISIBLE EDGE DISTANCE PER LIGHT SUBSTRATE,SEE 31 5 R@ HEIGHT TABLE 8. �+ TIP TO TIP WIDTH - TYP.ANCHO\NT 32 EMBEDMErYEXTERIOR EDGE DISTANLU TYP.ANCHOR TYPE, HORIZONTAL SECTION A-A SUBSTRATE,SEE ? INSTALLATION DETAILS FOR EQUAL-LEG'FRAMES INSTALLATION OPTION 2 INSTALLATION OPTION 3 INSTALLATION ANCHORED THROUGH FRAME ANCHORED THROUGH FRAME AND 1X E DIRECTLY INTO CONCRETElCMU. BUCKSTRIP INTO CONCRETE/CMU. EDGE DISTANC OPTION 1 =�______ SEE NOTE 2,THIS SHEET. ANCHOREDTHROUGH r EMBEDMENT EMBEDMENT FRAME INTO 2XC WOOD - 1 1l4"MAX SHIM 1/4"MAX SHIM �I t+-- FRAME OR BUCKSTRIP. J_ d EMBED- SASH VISIBLE 17 7' mv'4dwwm SEE NOTE 2,THIS SHEET. T ( EDGE „ LIGHT WIDTH 'I ° DISTANCE f7Drlt!a B aft °$ (— DISTANCE—Ei9a1z 'v;aft 114"MAX SHIM milia*Pt� 27 L__ FIXED VISIBLE ^ SEE TABLE ° I LIGHT WIDTH 3 NOTE B,FOR 18 HEADTYPE 30 44 TYP.ANCHOR TYPE, FIXED EMBEDMENTAND °• VISIBLE EDGE DISTANCE PER ' LIGHT SUBSTRATE,SEE HEIGHT TABLE8. 31 5 R@ 6 BUCK WIDTH - TYP.ANCHORTYPE, 32 EMBEDMENTAND d Y EXTERIOR EDGE DISTANCE PER UJI TYP.ANCHOR TYPE, HORIZONTAL SECTION A-A > w 45 EMBEDMENT AND EDGE SUBSTRATE,SEE o, O O ^18 45 TABLE 8. c d' DISTANCE PER SUBSTRATE, O to 14 SEE TABLE 8. N z w °I0p O --{ 114"MAX.SHIM VISIBLE LIGHT FORMULAS: O w Z 46 55 I (SHOWN FOR HI-RISE SILL;SEE p J o a w W o SHEET 9 FOR STANDARD SILL) Z m g r 43 DADE APPROVED MULLION,FBC WIDTH U U a J FB r BUCK 13 COMPLIANT ALUMINUMISTEEL FRAMING 'NO�p HEIGHT 63 USE EITHER 1 OR STEEL STUD.MAY BE VERTICAL OR @ SASH&FIXED LITE:BUCK WIDTH-4.12" 1W-LU < S SWEEP LATCH @ HORIZONTAL.SEE SUBSTRATE 0 j E HEIGHT(EQUAL-LITE) a MIDSPAN OR 2 PROPERTIES,TABLE 8. occ BOTTOM LOCKS BUCK HEIGHT2-3.23" r Z Z INSTALLATION HEIGHT(PROVIEW)SASH zLL VISIBLE EQUAL OPTION 4 @FIXED LITE:BUCK HEIGHTl2+4,28" ZO O HRO LIGHT LEG/BOX ANCHOREDTUGH @SASH:BUCK HEIGHT12-11.43" 2 H 00 HEIGHT FRAME FRAME INTO METAL J ICJ SHOWN HEIGHT(CUSTOM SASH) O. @FIXED LITE:BUCK HEIGHT-SASH HEIGHT-2.55" Z 0? 7aaV5 @SASH:SASH HEIGHT-4.60" 1 X EXTERIOR TABLE 8: O O J 33 Anchor Substrate Min.Edge Min.Embedment NOTES: 12 Distance I w 15 P.T.Southern Pine(SCx0.55) 9/16" 1-318" 1)USE ONLY SUBSTRATE-APPROPRIATE ANC HORS LISTED ON O J O OPTIONAL HI-RISE #12 Steel, TABLE 8.FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS.ANY Q LU 10 42 SILL SHOWN.SEE 18-8 Of 410 Aluminum,6063-T5 min. 3/8" 0.063" INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF aoll asap saua5 l"WEEP SHEET 10 FOR A36 Steel3/8" 0.063 THE WINDOW. NOTCH AT STANDARD SILL. SS SCreW \`11111111j1/�; EACH END rv4"MAx Steel Stud,Gr.33 Mn. 3/8" 0.045" 18 Gia 8)M WOOD BUCKSL LESS THAN 1-10 Y BE D INTO CK ARE ASBE PERTABLE � ONV LYNN4� 1 SHIM Concrete(min.3.35 ksi) 1" 1-3/4" '��•'' ,\CEN&, 1 114"410 SS CONSIDERED 1X INSTALLATIONS.1X WOOD BUCKS ARE OPTIONAL F'•• �_ CreteFlex Ungrouted CMU,(ASTM C-90) 2-1/2" 1-1/4" IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE.WOOD BUCKS P.T.Southern Pine(,913--0.55) 1" 1-3l8" DEPICTED AS 2X ARE 1-1l2"THICK OR GREATER.1X AND 2X BUCKS No.58705 '�r NO ANCHORS (WHEN USED)SHALL BE DESIGNED TO PROPERLY TRANSFER •: 1¢ REQUIRED IN Concrete(min.2.85 ksi) 1" 1-316" LOADS TO THE STRUCTURE.WOOD BUCK DESIGN AND , 1/4"Steel INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR FLANGE OR •� ° Ultracon Ungrouted CMU,(ASTM C-90) 2-1/2" 1-1/4" ARCHITECT OF RECORD. %�O.•. 5 T Q EQUAL-ILL ° P.T.Southern Pine(SG=0.55) 1" 1-318" ' '�`•'• �� FRAME SILLS 3) A)MIN.OF 3 THREADS BEYOND THE METAL SUBSTRATE. VISIBLE LIGHT WIDTH OR HEIGHT(ALSO REFERRED TO AS CORIDP,.•' \��` i,S "'••••" G�� B)USE ONLY FLATHEAD ANCHORS IN JAMBS.PAWHEX/FLAT HEAD TYPE IS DAYLIGHT OPENING)IS MEASURED FROM BEADING TO BEADING. �S�ONA- VERTICAL SECTION B-B ALLOWABLE FOR ANCHORS IN THE HEAD. 77/1111 l 11111` C)"UNGROUTED CMU"VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. A LYNN MILLER,P.E. P.E.N 58705 INSTALLATION DETAILS FOR INTEGRAL FIN FRAMES EDGE EDGE DISTANCE DISTANCE ��-- EMBEDMENT -- O 0 EDGE DISTANCE 1/4"MAX SHIM 1/4"MAX SHIM 5 SASH VISIBLE 17 AP)vUvarl an°°©p4ylaa etr3 rCa LIGHT WIDTH ! B ding $ EMBEDMENT is rtUhd 19 821s®1IDaic mdprt " . 27 �1/4"MAX EMBEDMENT (�. FIXED VISIBLE ���JJJ t 2 SHIM I I LIGHT WIDTH I &0 18 TYP.ANCHOR TYPE, PE—, EMBEDMENT AND EDGE FIXEDDISTANCE PER SUBSTRATE, 44 VISIBLE SEE TABLE 9. LIGHT HEIGHT 31 5 OR 58 5 BUCK WIDTH 00 32 TYP.ANCHOR TYPE, 9 Y HORIZONTAL SECTION C-C EMBEDMENT AND EDGE j w .as 45 DISTANCE PER SUBSTRATE,SEE Of TABLE 9.(NAIL SHOWN) o DADE APPROVED MULLION,FBC COMPLIANTALUMINUM/STEEL FRAMING OOa bW a1Dp W 14 1/4" MAX.SHIM �-I OR STEEL STUD.MAY BE VERTICAL OR O cc''�� HORIZONTAL.SEE SUBSTRATE —1 J O a m Z o PROPERT1Es,TABLE s. VISIBLE LIGHT FORMULAS: z'� m= 43 (SHOWN FOR STANDARD SILL;SEE U V BUCK 13 SHEETS 7 OR 8 FOR HI-RISE SILL) W °p J " HEIGHT 69 USE EITHER 1 F—Z v ¢ J °N SWEEP LATCH @ #10 OR STEEL WIDTH o LUF amp MIDSPAN OR 2 46 55 SELF-DRILIL LING @ SASH&FIXED LITE:BUCK WIDTH-4.12" 1` V }a rn BOTTOM LOCKS SMS(G5),SEE TABLE 9. Z o Z HEIGHT(EQUAL-LITE) Z .- SASH BUCK HEIGHTI2-3.23" Z O u- VISIBLEINSTALLATION LIGHT HEIGHT(PROVIEW) m = U 0) HEIGHT OPTION 7 @FIXED LITE:BUCK HEIGHT/2+4.28" ® rn LU W ANCHORED THROUGH @SASH:BUCK HEIGHT/2-11.43" ' (D INTEGRAL FIN INTO METAL = Z X ways HEIGHT(CUSTOM SASH) j (n STANDARD SILL @FIXED LITE:BUCK HEIGHT-SASH HEIGHT-2.55" < g EXTERIOR 16 SHOWN.SEE @SASH:SASH HEIGHT-4.60" p Z W Op 33 PREVIOUS SHEET O n 42 6 FOR OPTIONAL V :D � _ 1"WEEP HI-RISE SILL ¢ Z U) NOTCH AT EACH END 114" TABLE 9: au!1 rosap saua5 SHIM Anchor Substrate Min.Edge Min. NOTES: S SHI t —1Distance Embedment 1)USE ONLY SUBSTRATE-APPROPRIATE \\��SONY LYNN�� 2-1/2"x.113"Box Nail P.T.Southern Pine(SG=0.55) 5116" 2.438 ANCHORS LISTED ON TABLE 9.FOLLOW tGENgF'•.�( T 2-1/2"x.131"Common Nail P.T.SouthernPine(SG=0.55) 318" 2.438 EMBEDMENT AND EDGE DISTANCE LIMITS.ANY INSTALLATION OPTION SHOWN MAY BE USED No.56705 TYP.ANCHOR TYPE, 2-1/2"x.145"Roofing Nail P.T.Southern Pine(SG=0.55) 318" 2.438 ON ANY SIDE OF THE WINDOW. *; * EMBEDMENT AND EDGE EDGE DISTANCE 2-1/2"x.145"Roofing Nail P.T.Southern Pine(SG=0.55) 3/8" 2.438 ; DISTANCE PER SUBSTRATE, _� P.T.Southern Pine SG=0.55 1/2" 1.375 2)VISIBLE LIGHT WIDTH OR HEIGHT(ALSO .-0 41 SEE TABLE 9. #10 Steel Tmsshead Screw or ( ) REFERRED TO AS DAYLIGHT OPENING)IS V.TT --� EMBEDMENT 0.125"Aluminum,6063-T5 min. 5116" 0.125 MEASURED FROM BEADING TO BEADING. ��'., ((/�` (SCREW SHOWN) #12 Steel,18.8 or 410 SS 0.050"A36 Steel 5116" 0.05 '••FZORIDP.•'' VERTICAL SECTION D-D screw 0.645"(1a Ga)Steel Stud,Gr.33 min. 5116" 0.045 '!SS�0NAL j ,\\\� 11111 A)MIN.OF 3 THREADS BEYOND THE METAL SUBSTRATE. A LYNN MILLER,P.E. P.E.#58705 2.560" 3.185" 2.060" -� � 2.848" -� 2.848" T T f� .062" 1.125" j I 2.848" � .062" .062" L .062" r 2.724" 2.112" 2.724" 2.724" -T approved as complying wiW"r- -T PFT1 GFuri a,,riling c .062" � .062" � .062" .987• � 1.125" b3iara7 c to 9ro� INTEGRAL FIN FRAME EQUAL LEG FRAME HEAD 1 O4 FLANGE FRAME JAMB FIN FRAME 0 FLANGE FRAME HEAD O HEAD O O INTEGRAL O EQUAL LEG FRAME JAMB �- 2.798" 2.798" -+{ 2.798" •---� 2.798" 2.798° �I 2.798" U Y 3.006" W 2.841" 3.466" O 1.125" O 3.508° 1.125" 4.133' 00 .062" .062" .062" .062• .062" .062" ,co apto0 . z, (�-n aW o v g -Ta- FLANGE FRAME SILL QFRAME W co -ia �a FZFLANGE FRAME SILL EQUAL LEG FRAME SILL OSRW co =OHRSE JrQZMOnna• On OINTEGRAL FIN FRAME SILL 11 INTEGRAL FIN FRAME Z Z 2273" �� SILL-HI-RISE Z LL 1.300" .120" 2.273" -►I = �- .170" SILICONE HOT-MELTBUTYL m T+I ® N W POLYISOBUTYLENE 1/4"NOM. STRUCTURAL 3/16"NOM. ( j 2.772° T* WITH SILICONE = Z 1aa45 i1 2.150" 2.211" 2.105" •062" 1 I " DESICCANT WITH U) DESSIICCANT 6 j z o '�2" .062" EXT.GLASS O Z to o EXT.GLASS �I II I 1.300" I ANT.GLASS INT.GLASS U J X U .062" �+-. 1.300" �- '"'� 1.300" �+-- I f�T Q W 70 KODISPACE 45G TPS 71 SUPER SPACER®NXT rm a+1 'asap saua5 to SASH TOP RAIL to FIXED MEETING RAIL isSASH BOTTOM RAIL- to HI-RISE SASH BOTTOM RAIL t7 SASH SIDE RAIL �. NY LYN �•, ALUMINUM DESICCANTFILL ��.•"' NhI/ POLYISOBUTYLENE ,. Or- 1.446 •.• �-+ 1 446" �{ {{��-- I REINFORCEMENT SEAL 5116"NOM. ��,. (G �Oe I .634" 1 .465" -+{ �.61 T' I - •496"I� ROLL-FORMED SILICONE SEAL * N0.58705 1.522" 1 I_L _ 627, BUTYL& STAINLESS STEEL .040" DESICCANT - MAT%.813" . .802" .802" .802FOAM 'EXT.GLASS EXT.GLASS O •. '-"CORIOP,. N --�- 1.370° .070" .045" �I .050" ''7 i�lSs� ' o INT.GLASS INT.GLASS �,1'/7,,'O \� 18 HEAD ANCHOR is SASH STOP COVER-_ IG BEAD Zss IG SNAP BEAD xs 5/16"LAMI BEAD 27 7116"LAMI BEAD ® 111/NAL 1 tt� 72 DURASEAL SPACER 73 XL EDGE SPACER A LYNN MILLER,P.E.P.E.#58705 TABLE 11: Item PGT Part# Description Material 51 ASSEMBLY DETAILS FOR 1 642001 Head,Flange Alum.6063-T6 FLANGE FRAMES 2 624017 Head,Integral Fin Alum.6063-T6 (OTHER FRAME TYPES SIMILAR). 3 624028 Head,Equal4eg Alum.6063-T6 a 4 624004 Jamb,Flange Alum.6063-T6 4 4A Jamb,Flange(Used For Alternate Radius Top Head) Alum.6063452 1 5 624020 Jamb,Integral Fin Alum.6063-T6 51 1pnrovcd did ldW ti"..tngwl 5A Jamb,Integral Fin(Used For Alternate Radius Top Head) Alum.6063 .IE T52 Dekln aril.V e 6 624031 Jamb,Equal-leg Alum.6063-T6 N ml��produetCoave , 6A Jamb,Equal-leg(Used For Alternate Radius Top Head) Alum.6063452 40 HEAD 7 624002 Sill,Flange Alum.6063T6 1" 8 624018 Sill,Integral Fin Alum.6063-T6 INTERIOR 41 9 624029 Sill,Equal-leg Alum.606346 JAMB 10 624003 Sill,Hi-Rise,Flange Alum.6063-T6 11 624019 Sill,Hi-Rise,Integral Fin Alum.6063-T6 12 624030 Sill,Hi-Rise,Equal-leg Alum.6063T6 q 14 13 624006 Sash Top Rail Alum.6005A-T61 INTERIOR 14 624005 Fixed Meeting Rail Alum.6005A-461 15 624012 Sash Bottom Rail-Hi-Rise Alum.6063T6 JAMB W °° 16 624068 Sash Bottom Rail Alum.6063-T6 17 624007 Sash Side Rail Alum.6063-T6 FIXED MEETING RAIL o o o "tea w v o 18 624051 Head Anchor Cover Alum.6063-T6 } �' aro0 O 19 624015 Sash Stop AIum.6063-T6IJW t7 N z 25A 624009 IG Bead Alum.6063-T5 OJ M Z Z 25B 624011 IG Snap Bead Alum.6063-T5 Z LL m m W o 26 624013 5/16"Lami Beading Alum.6063T6 0 V SASH BOTTOM RAIL 9 t` =LL 27 624026 7/16"Lami Beading Alum.6063-T6 W U 6 �mo�0 30 6TP247 Glazing Bead,Bulb Vinyl for#624023 Vinyl SASH zLLI �' ;¢ 'MN 31 6TP248 Glazing Bead,Bulb Vinyl for#624009򘖋 Vinyl 4 SIDE 1s r> a 32 724046 Sweep Latch(@ Top Rail) Cast Zinc RAIL z �.' 0 z 33 624049 Bottom Latch(@ Sill) Alum.6063-T6 JAMB 0 w 34 Setting Block(1/8"X 1/2"X4") Neoprene Z -1 0 � O 35A IG Setting Block(1/8"X3/4"X4") Neoprene 2 W 35B 724014 IG Snap Setting Block Vinyl 17 ® p 36 724044 Bottom Rail Weatherstrip Extension a (7 a 37 724053 Sill Gasket Polyethylene Z W laays 37 U) z 38 724054 Sash Top Rail Gasket Polyethylene ¢ 39 724055 Sash Bottom Rail Gasket Polyethylene p Q C) o 40 724057 Head Gasket Polyethylene w Z uC 41 724053 Meeting Rail Gasket Polyethylene INTERIOR O ? O 42 61226D Sash Bottom Rail Bulb Vinyl Polyethylene 39 ¢- m 111 43 Weatherstrip,.270"x.187",Fin Seal(@ MR) 'rr'i -o s""S 44 67S16G Weatherstrip,.170"X.270",Fin Seal(@ Sash Side Rail) 45 Weatherstrip,.170"X.187",Fin Seal(@ Top Sash Rail) \\1 LYNN LYfV 46 varies Balance with Cover&Trim Rigid Vinyl SILL TABLE 10:MATERIAL PROPERTIES USED \��\1 •......N/��� 51 781PSQX #8 X 1"PH SMS(Assembly) Stainless Steel 51 FORANCHORAGE CALCULATIONS: `�A;.•'v\GENSF '•.�� 55 7834AA #8 X3/4"Ph.PN SMS(Balance) Stainless Steel 7 Material Min.Fy Min.F. Q:: P Steel Screw 92 ksi 120 ksi No.58705 63 Alum.Screen with Fiberglass Mesh Varies =s> _ 70 - Kommeding Kodispace 4SG TPS INTERIOR 18-8 Screw 60 ksi 95 ksi _ _ 71 Quanex Super Spacer nXi See Sheet 410 Screw 90 ksi 110 ksi' ='t] = *.A 72 - Quanex Dumseal Spacer 10 for 51 Elco UltraCon@ 155 ksi 177 ksi OF <[/ Materials NOTES: 410 SS Elco CreteFlex@ 127.4 ksi 169.7 ksi %�T '•.•F(ORID P•.•' \?� 73 - Cardinal XL Edge Spacer %CC ••.....•• C, 74 - Dow 791,899 or GE 7700 Backbedding Silicone 1)ALL CORNERS TO USE GASKET AND/OR SEALANT. 606 AN Slteelnum 36 ksi 58 ksi "."/"/j0NA1- Gr.33 Steel Stud 33 ksi 45 ksi 2)SOME PARTS/OPTIONS NOT SHOWN ON DRAWING FOR CLARITY. A LYNN MILLER,P.E. P.E.#58705 Ii