Loading...
HomeMy WebLinkAboutProduct Approval _ e a 11 MY = BCIS Nome Log In User Registration Kot Tapirs # Submit Surcharge Stats&Facts 4 Publications SM CUs SCIS Site Map Links ! Search Florida product Approval USER.Public User Product Aoproval Menu>Product or Aoplication Search>Application List>Application Detail LRECEIVED s - _ � •`� FL# FL16842-R5 ." Application Type Re 2020Code Version 2017Application Status Approved ty, Permitting Comments Archived Product Manufacturer ew5outh Window Soltio ns Address/Phone/Email 10741 Crossr merce Blvd. tampa, FL 33610 (813)626-6000 danochstein@newsouthwindow.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative AV Address/Phone/Email FILE U"' 1hVY Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2020 Validated By Ryan J. King, P.E. s Validation Checklist-Hardcopy Received Certificate of Independence FL16842 RS COI (!0) Certificate of Independence. Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2008 AAMA/WDMA/CSA101/I.S.2/A440 2005 AAMA/W DMA/CSA101/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2005 ASTM E1996 2009 TAS 201, 202,203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method I Option D Date Submitted 06/19/2019 Date Validated 06/21/2019 Date Pending FBC Approval 06/26/2019 Date Approved 08/13/2019 Summary of Products, rod ucts Go to Page i Page 1 2 0 0 FL# Model,Number or Name Description 16842.1 a. Series 9000 Model 9500 Slider XO Extruded Vinyl "Non-Impact" Horizontal Sliding Window utilizing a Nail Fin Installation(XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 P5 II—MInst 16$42.1.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.1 for Design Pressure Ratings, any FL16842 RS AE (e) Eval16842.1.12d additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 16842,2 b. Series 9000 Model 9500 Slider XO Extruded Vinyl "Non-Impact" Horizontal Sliding Window with I Flange Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 IRS II (b) Inst 16842.2.Ddf Approved for use outside HVHZ:Yes Verified By; Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.2 for Design Pressure Ratings, any FL16842 R5 AE (a)_EyALj53_42,.2_p_df additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 168423 c. Series 9000 Model 9550 Slider XO Extruded Vinyl "Impact"Horizontal Sliding Window utilizing a -Impact Rated Nail Fin Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R5 II (b) Inst 16842.3.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.3 for Design Pressure Ratings, any FL16842 RS AE (g) Eval 16842.3 pff additional use limitations,installation instructions and product Created by Independent Third Party: Yes particulars. 16842.4 d. Series 9000 Model 9550 Slider XO Extruded Vinyl "Impact"Horizontal Sliding Window with Flange -Impact Rated Installation(XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R5 11—( ) in t 1 2.4.E Approved for use outside HVHZ.Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.4 for Design Pressure Ratings, any FL16842 R5 AE (_e)_fyaLj63_42_4.p_df additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 1 1 16842.5 e. Series 9000 Model 9550 Slider XO Extruded Vinyl"Impact"Horizontal Sliding Window utilizing a -Impact Rated- HVHZ Nail Fin Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL16842 R5 11 (¢)Inst 16842.5. If Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842,5 for Design Pressure Ratings, any FL16842 RS AE (e) Eval 16842.5'pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. `�;1111 ll lit` ... tttr ;4r k�i YS N'e. ,`�Southr �1�+ .�of ro ;`deM �ti ....... . `�ti a S i4 4901 Oa it vd.,Tampa,FL 33610 75'MAX,OVERALL RANGE WiDTN Sedes 9000 Model 9550 7k"MAX.OVERALL FRAME WIDTH SLIDER XOCh IMPACT RATED - HVHX //� ,� 6o wl Flange i GENERAL NOTES F 1. This product has been evaluated and is in compliance with the 61h Edition(2017)Florida i z w Building Code(FBC)structural requirements including the"High Velocity Hurricane Zone" (HVHZ). X # a v a 0 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to of a base material shalt be beyond wall dressing or stucco. x0 a a �. 3. When used in the"HVHZ"this product compiles with Section 1626 of the Florida Building Code a. and does not require an Impact redstant covering. ° v r4. When used in areas outside of the"HVHP'requtring wind borne debris protection ihtspraduci complies with FBC Sections 1609:1.2&R301.2.1.2 and does not require an impact resistant L1XV _ f o o coverfi g.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM -- -___—�. w g` w En E1996 and FBC Sections 1609.1.2.2&R301.2.1.2.1. 8= o U = {f) 5. For 2x slud framing construction,anchoring of these units shall be the some as that shown for 2x buck masonry construction. 4 o 6. Site conditions that deviate from the details of this drawing require further engineering analKa g by a licensed engineer or reglsfered architect. i 7. This product meets wafer Infiltration requirements for"HVHZ". A, QVERAii MAX L1b@RAtt MRX MlXit y o u z TARLE OF COt MNIS rn " SHEET# DtSCRIP170H fUNGt TRXAir DAYGtE >�AlrttfE GUISS AtxfGNPRESSURE 1. I Typical elevations,design pressures&general notes p1M �jENSIQN DiMFhfSiAN 7Yt DAM t9/ta i DIMEJVSiOp1 TNStON` � ° 2 Vertical&hdrizoniai cross sections - 3' Vertical&holizoninl cross sections 75A"X d0.0" 74.0 x 63.Q" 33.6')t 5731" 3315 x 5&56" GT,G2 455,0 -60.0 °"c °" JK 4 Buck&frame anchonng c�K.sr LFS } 5 Components °nsew°No m 5 6 Bl o materials and.glazing details Note:This product,when used with Gl glazing,Is not approved for use above 30 feet In the"HVHZ". FL-i&8a2.6 d P SxFEr 7 or & �, c' 111 !f Q� INN ... NOTE'SheetMetol Screws must penetrate a C� K min.of 3 threads through at least 2 sheets of =-,• — 1111►► d metal{maintain a mtn.3!g'edge distance). k = =z h '.aL"`-�m I I C 1 1 2 E a a �rrtt 11 8 cR Z i C71 G2 M1 m'aa� coati , gE k ul 2 / 11I 1 F B & a J1 ~ C J -- 2 w aQz Note: 2 17 SEENOTE3 No F 1.Lock and keeper located T'from 2 k �� each end of locklmeeting stile. 2.Metal.roller on, mbly located 2"from 4 HORIZONTAL CROSS SECTION m ' each end of the bottom rail. 2 Metal Stud Consiruction Gl 5 z y 5 3.Anti-lift secured to head with " E G2 �� o S EXTERIOR INTERIOR a 1-ii4"MIN. EMB.(TYP.) > m p' G2 G1 3 o zo E ca C C 2 ° INTERIOR a F 6 13 a o 18 10Gl G2 SEE NOTE 1 11 B z i w o 7 o 14 SEE NOTE 2 n rn J 12 o r=a v 1 ib o a a 2� G1 G2 Oa, i LL 3 r ^� o ° .a Y cz h J ro = 4 1 —. ove 2 19114 Z D 9 9 � 1-114"MIN, a z scut: N.T.S. G 1 2 EXTERIOR EMB.(fYP.) owc.BY.. JK m E1 HORIXONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION 3 VERTICAL CROSS SECTION 1 `"s'8Y, LFS $ 2X Buck MT.. Construction 2 IX buck Masonry Construction 2 2X Buck Masonry Construction °�WNC NQ'' a FL-16642.6 a sera_L OFAll 0 6 a ig 6 NOTE:Sheet Metal Screws must penetrate a '`�,�R»;»,... •. 'r K min. Iml3 threads through at least 2 sheets of melot atnWin a min.3f3"edge duiance). 1 2 Ez 3 v n 3 d �, Q X • � . � $ � agz°� Gt G2 �g 9 oa 7 M a a Ia D 40 d Ba 2 � C Note; 3 17 SEE NOT E3 No 1.Lockand keeperlocated T'from 3 pq xw each end of lock/meeting stile. 2.Metal roller assembly located 7 from r4 HORIZONTAL CROSS SECTION Gt a �N each end of the bottom rail. S Metal Stud Construct'wn 5 2 0 3.AntHift secured to head with G2 (6)ti6x1/2"PPHSMS. nE $ �� o s ALTERNATE ANCHORING LOCATION EXTERIOR INTERIOR u t-114"MIN. SHOWN ON THIS SHEET I5iEMB.(iYP.) A G2 Gil 3 d B yr , U Z G C C 215 Al INTERIOR_ INTERIOR t L 10 7 Gl G2 13 °ti ❑ 4� �.. 18 N a g N U SEE NOTE 1 til D 14 SEENOTE2 i rn b G J 12 16 agaa a g G1 G2 C w MQ.oa . Q.Qz% Z 3 a B ^min . a r • N N^NFA- �y f V N N^N Q � . a ° rnrnfism� m Z E Q 0AX, 2/19/14 9 1 2 9 EXTERIOR EMB."MIN, N.T.S. r r z srua m ` MP.) 2 M BY. JK E 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION 3 VERTICAL CROSS SECTION WA e LFS 2X Buck Masonry Construction 3 1X Burk Mas Conshucflon 3 2X Buck Masonry Corutrucflon °u WM N6 a z � �orrY � FL-1fi842.6 n n sHrzr 3 or 6 p 0 I fill .. ' Z a"ttYP•J (tYP.I w { (1Y.J ttRll*111 "�Z ti 4.1 S 0 4" D TYP. cx 0 `v to a c[AFRAME F L 2X BUCK 2X SUB 2X SUB D IXBUCK BUCK BUCK K SIEE7 STUD MASONRYw OPENING MASONRY TYP• z OPENING z i a U z U Q 2XSUCKANCNORING_ PRAMBANCNOWIG N o s N J Z wOB 0 W � W CONCRETE ANCHOR NOTES: a q a t.Concrele anctrorbcaRons at the cornea maybe odfuded to mafntdfn fho'min. CL v a u edgocatonce to mortarjotnts. 2 Concrete anchorloeatrons noted as h1AX.ON CENTER'must be adtusfed to matnttttn the mh edge dstonce fomaI-Aifs,odd thonot concrete anchors N v7^N F- N N^N d F may be requhed to onxRe the"MAX.ON CENIER'dfinension aro rwl exceeded. p 1 I Concrete onchortcbte: ^ z ANCtQR MfN C4EARANCt: MIP('CI,E17kANGE, a n N--o ANCf7Ok MIN z � ..:7i'PE St1'R EM$EDMENT .7OMASQNRY.., 7OAQ71lC : EtSGE 4NC}tORa..:. M7E 21191 ft14 i TAPC N� 1/s 1-tj4' T 4' scAW N.T.S. EtCO 1/4' 7-714' T" Q MD.r7r: JK m . ULiRACON cm ey., LFS +?, wooDSCREWtNNALLATIONNOT S: DRAWING No.: a 1.MafntcM a m67unum 5J9-edge distance,l"end distonce,&1"o,c.spadng of ° FL-16842.6 wood screws to prevent the spOtti g of wood. a SHM 4 OF.6 9 a u !i.{dientslNew South Wndav4 PERMANENT\A-Florida ProductA rowals\FL-16842 Horizontal 5lider\C-Drawin FL-16842120171\FL-16842.6. 5.6 b ' c� rn 3.29" paa N O 4" T O 7A ❑ z r-• 1.24" � � rtTr ,� o 7a L q a n T o � � a 7p (0.4,1 to -•—0.21" p F�----#— 0.5" _ 4 0 �1.66" en V T 11 0 .0.06". y ? S 0 0 L71.29" {�—0.44 0.94" D a aor• 0.07" Alt Tz F ao o�G� 1 I JLL ``1111 II Ili/I,,I. /'rte Na 43400 '" Oatoher 08,2017 iI PRODUCT: o—u—ts F'rnpared Ety:„ •• 4 NewSouth Lyndon F. Schmidt r��• ••'•:� � ���~ 4 922 T7 UPDATE TO 6TH ED. 20T7 FBC JK 1 No. 43409 3 9-26 T6 ADDED ALT,ANCHOR LOCA71ON LFS �11t77I11p 2 T2 T7 i5 REVISE MODEL NAME RDD GLAZIN JK PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. �� nT yl. 7 6 25 15 UPDATE TO.5TH EA.T. FOC LF5 P.O. Box 230,Valrico, FL 33595 NO GATE BY Phone No.. 613.859.9197 REVISIONS COMPONENTS ,FsPE CA. No. 9813 08014 R.W.a.,L m.CoNSULTAHTs IxC. BILL OF MATERIALS % ......... OEM# DESCRIPITON MATMAL %4 • •,ti ,�� B2X BUCK{SG>.=0.55) WOOD C: 1/4"MAX;SHIM SPACE D 114"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI �'� '`•.., „ ' .` o m E CONCRETE 30T OR HOLLOW BLOCK CONFORMING TO ASTM C90 iz d m 6 F #10 X 2"PFH SMS—(IA14"MIN.EMBEDMENT) STEEL ,z J: STEEL STUD Mn.Thk.033" (ASTM A653 GRADE 33 Fy=M ksi min.,Fu=45 ksi min.) STEEL r n 0 k z K #IO PPH SELF-DRILUNG SMSSTEEL �i =A 0 _° 3 -.. L #10X2"PPHSMS(1-1/2 MIN.EMBEDMENT) STEEL g 5U 5/8" 1 EXTRUDED VINYL FRAME(439)' RIGID PVC 7/B"O.A.GLASS THK. 2 EXTRUDED VINYL GLAZING BEAD(736A)' RIGID PVC GLASS BITE o 3 EXTRUDED VINYL GLAZING BEAD(425A)' RIGID PVC GLAZINGFSEALANT d 4 BOTTOMRAIL 424B) RIGID PVC 5 TOP RAIL,(478)• RIGID PVC 118"ANNEALEDGLASS 6 MEETING STILE(477)' RIGID PVC 7. LOCK STILE(476)' RIGID PVC f 0.M'SAFLEX"PVB INTERLAYER; B. HANDLE STILE(4758)' RIGID PVCt�., 0 9 MEETING STILE REINFORCEMENT 6063-T5 ALUMa —1/B"ANNEALED GLASS ��. 10 LOCK STILE REINFORCEMENT 6063-T5-ALUM AIRSPACE m �? 1 i SASH LOCK 1!8 ANNEALED GLASS z n 4 LL 12 KEEPER T—� ! 13' HANDLE STILE REINFORCEMENT 6463-T5 ALUM METAL REINFORCED BUTYL ? �� 0 7d 14 ROLLER(TRUTH#2433-1000). Not approved for use above 30 feet In the"HVHT'. & 15 SILL RISER 6063-TS ALUM a a 16 ROLLER TRACK 6063-T5 ALUM GLAZING DETAIL y N a 17 ANTI-UFT ALUMINUM 6063-T5 ALUM m e 18 BOTTOM RAIL REINFORCEMENT 6063-T5 ALUM zc� 20 1 WEATHERSTRIP(.187'X.290") 0 = nficn f THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY 5!B N o EXTRUDERS LICENSEES IN"AAMA CERTIFICATION'PROGRAMS FOR RIGID PVC EXTRUSIONS". GLASS BRE 7/8"O.A.GLASS THK. W 8 a GLAZING SEALANT zz N (SIKAFLEX-552) 6 to Y 1/8"ANNEALED GLASS a L—JO.OS `SAFLEX�PYB INTERLAYER to.k-.t 4 g 1/8"ANNEALEDGLASS a rz AIR SPACE N rntn^o T I/6 TEMPERED GLASS "s z n° METAL REINFORCED BUTYL DATE 2119114 z scare: N.T.S. a � GLAZING DE7AlL nwC,v*: JK m �S G2 CNK 64 IFS 3 s ortamHc No,: y E FL-16842.6 0 a SHEET 6 OF 6 g a