HomeMy WebLinkAboutProduct approvals, underlayments Florida Building Cade Online Page 1 of 2
�J_()0a` 00 a
P,
1� D
BaS Home Log in i User Registration i Hot Topics ; Submit Surcharge I Stats&Facts Publications l FBC Staff ; BCIS Site Map j Unks Search i
HOdda
">} ai Product Approval
i £ USER:Public User
410
t
Product A"ro aV 1 Menu>Product or Aopitcatlonse4r h>APD-ca600-1.ist>Application D /�
i Q
ITFL Q F1.2569-1114
Application Type Revision ® ` d
Code Version' 2017 3
Application Status Approved
Comments
Archived 1
i
i
Product Manufacturer Soprema,Inc.(Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville,NON-US 00000
(819)478-2400
memath leu@soprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Emali 1688.lean-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
El Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert 3. M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W. Knezevich,PE
'�,.Validation Checklist-Hardcopy Received
1 -
Certificate of independenceFL 52 69 R14 COi 2018 Q1 COI EMINEN.Of
i
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D4798 2011
ASTM D6163 2008
FM 4474 2011
FRSA/TRI April 2012(04-12) 2012
UL 1897 2012
http://www.floridabuildina.oT pr/pr app dtl.aspx?param=VGEVXOwtDasKOFEnckR 14 4/20/1701 R
I'.
Florida Building Code Online Page 2 of 2.
Equivalence of Product Standards
Certified By I
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02/12/2018
Date Validated 02/1412018
Date Pending)FBC Approval 02/17/2018
Date Approve d 04/10/2018
Summa ry of,Products
FL# Model,Number or Description
Name
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL2562 R14 E
Approved for use outside HVHZ:Yes _R1-4--pdf
'i
Impact Res 5tant
-N/A Verlfied,By:Robert Nieffinen,P.E.PE-59166
Design Pressure:+N/A/-150 Created by Independent Third Party:Yes
Other:1.)Refer to ER Section 5 for Evaluation Reports
Limits of Use,.-2.)The design pressure F_12569-
noted herein!pertains to underlayment R14-pdf
systems used beneath adhesive-set tile Created by Independent Third Party:Yes
systems.Refer to ER Section 5.6.4 for
details.
Back Ftext
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.copyright 2007-2013 State of Florida,::Privacy Statement::Accessibility Statement Refund Statement
Under Floridalaw,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,FS.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts-
CHI
Credit Card
Safe
-2
5- 7-
55�
http://ww-w.floridabuilding.org/pr/pr app dtt.ast)x?t)aram=wGEVXOwtDas'KOFFnc-kRIO 4/70/9015Z
11
t
ti NE11401 etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford,CT 06478
(203)262-92245
ENGINEER EVALUATE TEST CONSULT CERT IF;
Soprema, Inc. Evaluation Report 518010.06.09-1112
1640 rue Haggerty FL2569-1114
Drummondville,Quebec J2C 5P8 Canada Date of issuance:06/15/2009
(819)478-2400 Revision 12.:02/12/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the eh Edition (2017) Florida Building Cade
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be!in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
l
CONTINUED COMPLIANCE: This'Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to
the product(s),the Quality,Assurance or the production facility location(s). NEMO Ietc. requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTiSEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTIONS: Upon request,a;copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M.Nieminen,P.E. •,+Yc,s, ti�J?r The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 Ste; o`* Nieminen,P.E.on 02/12/2018.This does not serve as an
=•J�n.. electronically signed document
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LCC is not owned;operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports'are being issued.
4. Robert Nieminen,P.E.does not have,,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically forthat purpose.
I
R
I -
I
NEIVIO etC.
ROOFING COMPONE1 T EVAWATION:
e
Product Category: j Roofing
Sub-Category: ; Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the 6`I'Edition (2017) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
MAEi
D"D
Section ProloeriM Standard Year,
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 j Wind Uplift UL 1897 2012
1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012 2012
FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008
TAS 110 Accelerated Weathering ASTM D4798 2011
f.
Entity Examination Reference` Date:
ERD(TST6049) j ASTM D1970/TAS 110 2968.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ( ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) i Wind Resistance 2779.11.05-R1 04/18/2007
ERD(TST6049) i TAS 103/TAS 110 57120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/'FAS 110 S13190.02.09-111 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 S31370A3.10-1-R1 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.10-R1 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-R2 10/05/2010
ERD(TST6049) i ASTM D1970 537210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 S40540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 15-0508.64 09/24/2015
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.07/18/2020
4.1 Lastobond TU HT �is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof
underlayment;meet's ASTM D1970 and FRSA/TRI April 2012(04-12)..
4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths;36 and 45 inch;meets ASTM D1970.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available in 3.3 ftx 65 ft roils;meets ASTM D1970.
4.4 Lastobond Shield HT is a self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof
underlayment;meets ASTM D1970.
"SEm,0 ETC LLC Evaluation Report 518010.06.09-1132
Certificate of Authorization#32455. 6'FDIT101',J(2017)FBG N NN-HVHZ EIrALUATION F12559-1114
Soprema Roof Underlayments Revision 12:02/1212018
Page 2 of 8
`
\
/
'
,
�. ��E 6�0�etC^
4.5 Lastobond Pro HT N is aself-adering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available hntwo widths;36and 45inch;meets ASTM D1970.
4.6 Lamto6mndPnzself-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof
under|ayment;meet A3TK0D197O.
i
4.7 EoxirmSh(eVd is a se|f-adhering, woven polyethylene surfaced' high temperature, 38S modified bitumen roof
undedayment;meets ASTM D1g70.
4'8 Lasto6ond 195ba!ue|f-adhering, glass'matreinfoned, xan6*urfaced' SBS modified bitumen roofundar\ayment;
meets ASTM D197 '1.
,
4.9 bastobond Eaves Protection Sheet is a'aelf-adhering, glass-mat reinforced, sand-surfaced' SOS modified bitumen
roof undedayment;|meetoASTM D1970.
4.10 Lamtmbomd Eco isa`se|fadherin8, glass-mat reinforced, uand-surfaced, SBS modified bitumen n,ofundedayment;
me$s4ST� D1Bn3/
4.11 LaatobmodSnoctb|Som| HT base|f-adhering, glass-mat reinforced, fi\m-audaced,_SBS modified bitumen roof
under|ayment;meeisASTK8D137n.
4.12 RESISTOL81236is self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,
with a56-inchsheet width;meets ASTM D1g7O.
4.13 PrimeSource Grip-/de Eaxe @. Valley Protector is a self-adhering, glass-mat reinforced, sand*urfaued, SBS
modified bitumen roof underlayment,with a 36-Inch sheet width;meets ASTM D1970.
4.14 RES0TOLW1244is a self-adhering,glass-mat reinforcedsand-sudaced'SBS modified bitumen roof under|ayment,
with a 44-Inch sheet i width;meets AST M D1970.
4.15 Colphene FR GR �is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRl April 2012(04-12).
5.1 This is a bull,ding code evaluation. Neither NEMO ETC, LLC nor Robert Nleminen,P.E.are,in any way,the Designer
nfRecord for any onvxhichthisEva|uationReport,orprevouuvesionsthereotis/\masusedfnrpennitbng
ordesign guidance unless retained specifically for that purpose.
5'2 This Evaluation Report isnot for use inFBCHVHZ jurisdictions.
5.3 Fire Classification ispot part ofthis report;
` refertocurrentApprovedRoofingN1ateria|sDirectoryforfireratin@sof
this product.
�
5.4 Sop,ema gwmf Uu6odayments may be used with any prepared roof cover where the product is specifically
referenced within FDC approval ducun!ents. If not listed, a request may be made to the Authority Having
Jurisd�tionfor approval based unthis eva|uaboncombined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
r�r 1
N ' t .
Wood or State ox:
Asphalt Nail-On Foam-On Composite
Underlayment Metal Composite
Shingles 'life Tile Shakes& Slate
Shingles
Lastobond Eaves Protection Sheet/
Lastobond 195 Yes No No No. Yes Ycs
Lastobond ECO /RESISTO LB1236,
Grip-Rite Eave&Valley Protector J Yes No No No Yes Yes
RESISTO LB1244
Lastobond Smooth Seal HT Yes No Na Yes Yes =+ Yes
Colphene FR GR �� Yes: Yes No: - Yes Yes
See551
5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations.
. w
Adhesive, Florida Product Approval Underlayments'
DowUeBondTM FL22525 Lastobond TU HT
ICP Adhesives Polyset6 AH-160 FL6332 Lastobond TU HT or Colphene FR GR
i
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Lastobond Shield;Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESiSTO
LB1236,Grip-Rite!Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
9 Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41 primed
Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
> Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming
with ElastocoliStick or Eiastocol 600c if the final roof cover is not slated for installation within 24 hours.
> Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of
the self-adhering underlayment.
5.6.2 Bond-to-insulation:
Lastobond Shield,Lastobond Pro HT-N,RESiSTO SA SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195; Lastobond ECO, RESISTO
L81236, Grip-Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
i,
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on
tile systems (Lastabond TU HT only), insulation attachment shall be designed by a qualified design professional
and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D,
Testing Application Standard TAS 114,Appendix 1 or UL1807.
i
_ I
2 Refer to Tile Manufacturer's orAdhesive Manufacturers Florida Product Approvalfor Overturning Moment Resistance Performance.
MEMO ETC,LLC Evaluation Report 518010.06.09-1112
Certificate of Authorization 1132455 6'EDITIMI(2017)FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12:02/12/2018
Page 4 of 8
I
N ERAO etC.
5.6.3 Bond to Mechanically Attached Base Laver:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield,HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip-Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems (Lastobond TU HT only), base layer shall be
attached in accordance with FRSA/TRi April 2012(04-12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012(04-12)does not
address wind ',uplift resistance of all underlayment systems beneath foam-on tile systems, where the
underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determination of design wind pressures.
#1 Maximum DesiAn Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional)Elastoco)Stick,Elastocol 600c or RESiSTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol600C
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
#3 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: : (Optional)RESISTO EXTERIOR PRIMER
Underlayment: i Lastobond TU HT, self-adhered, shall be thoroughly roll using hand roller and/or weighted
roller to ensure there are no voids, and ensure there are no voids/bridging at side and end-
laps.
#4 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
' Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC
1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c, in three (3),equally spaced rows
in the center of the sheet.
Underlayment: j Lastobond TU HT or Colphene FR GR,self-adhered
5.6.4.1 All other direct-deck, adhered Soprema underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf.
I
MEMO ETC,LLC I Evaluation Report 518010.06.09-RI2
Certificate o/Authorization#32455 G 6'EG{TlON(2017)FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underiayments Revision 12:02/12/2018
Page 5 of 8
I
NEN10jetc.
5.6.4.2 For mechanically;attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012(04,12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FISC 1609. In this case, Zones 2 and 3 shall employ an attachment
density designedi by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WDI, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117.
Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention
Data Sheet 1-29('January 2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Lastobond Eaves{Protection Sheet,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,RESISTO LB1236,
Grip-Rite Eave &,Valley Protector or RESISTO 161244 shall not be left exposed for longer than 30-days after
installation.
Lastobond Shield',Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT or Lastobond Pro HT-
S7,EnviroShleld shall not be left exposed for longer than 90-days after installation.
Lastobond TU Hf or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)):
When loading roof tiles on the undeflayment in direct-deck the assemblies,the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
`
2
-A -r-4 -
xim
Underlayment Tile Profile Staging Method MaSlop
.lopum
e
Flat Max,10 file stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack
shall be inverted,followed by 8 tiles high 6:12
on slope,as shown below)
Yf
Lastobond TU HT
Lugged
Q-
lat Max.10-tile stack 5:12
Colphene FR GR i
Lugged Max.10-tile stack 6:12
it
MEMO ETC,LLC Evaluation Report 518010.06.09-1112
cert1ficate of Authorization#32455 e'EDITION(2017)FBC NOWTVHZ EVALUATION FUS69-RM
Soprerna Roof Underlayments Revision 12:02/12/2018
Page 6 of 8
1
�y� C J 5 y* l�s'�✓' 6. '6fr i �S"�.N � �4�h
6.1 Soprema Roof Underlayments shat( be installed in accordance with Soprema published insta(iation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol 600c or
RESiSTC}EXTERIORIPRIMER(if applicable).
6.3 Lastobond TU WT, Last66ond.Shield,1astobond.Pro-,HT-N, RESISiO SA SMOOTH Ply 40, Lastobond.Shield MT,
lastobond.Pro HT-S,EnviroShieid,_Las.tobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,Lastobond
Smooth Seal HT,RESISTO LB123%.Grip-Rite Eave&ValieyProtector,,RESISTO;LB1244;or Colphene
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.3.2 Non Tile Applications:
While priming is optional,Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTCi EXTERIOR
PRIMER if the final roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of
release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane
tight. Firmly roll th;e membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches,configured to shed water. Vertical seams should be 6-inches and
staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed
using either heat-welding or hot.air welding techniques.
When installing at;slopes above 8:12, Soprema recommends back-nailing in the overlap area at the top of the
sheet at 12-inch o.d.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge. Drape and press sheet into place,working from the center of the valley or ridge in each direction.
For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Lal stobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012(04-12) installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall
outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded!and staged in a manner that prevents tile slippage and/or damage to the underlayment. See
Table 2 herein,and Soprema published requirements for tile staging.
yrs .-`:ixr
As required by the Building Oficial or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
t
I
i
E
I
i
I'
I,
NEN10 ETC,LLC Evaluation Report 518010.06.09-R12
Certificate of Authorization#32455 6'EDITION(2017)FEC NON-HVHZ EVALUATION F12559-1114
Soprema Roof Underlayments Revision 12:02/1212018
Page 7 of 8
I
I
EMO Q etC.
Contact the noted QA agency for information on product locations covered for F.A.C. 61620-3 QA requirements.
The following plants have qualified products under-their respective physical properties specifications.
Planf.. Specification. Prbdiact(s)
Lastobond Shield,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,
Drummondville, Lastobond Pro HT-N,Lastobond Pro HT-S,EnviroShield,Lastobond 195,
QC(Canada) ASTM D1970 Lastobond Eaves Protection Sheet,Lastobond Eco,Lastobond Smooth
Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley
Protector,RESISTO LB1244
ASTM D1910&FRSA/TRI 04-12 Colphene FR GR
Wadsworth,OH Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco,
ASTM D1970 Lastobond Smooth Seal HT,RE515TO LB1236,PrimeSource Grip-Rite
Eave&Valley Protector,RESISTO LB1244
ASTM D1970&FRSA/TRI 04-12 Lastobond TU HT;Colphene FR GR
Gulfport,MS Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco,
ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite
Eave&Valley Protector,RESISTO L81244
IN,
0 e �
M Mo
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-_
I
i
I
i
i -
i
I
i
I
i
I
i
NEIVIO ETC,LLC Evaluation Report 518010.06.09-1112
Certificate of Authorization#32455 6"EDITION(2017)FSC NON-HVHZ EVALUATION FL2569-1314
Soprema Roof Underlayments Revision 12:02/12/2018
Page 8 of 8