Order(Ref)#: 59918 (43881-3819791667) Project Details: ABU-ISA CONDO DOOR REPLACEMENT
Contractor: J&G CARPENTRY, INC. 9600 S OCEAN DRQ, UNIT 1407
FI
7030 S.W. 16TH COURT PEMBROKE JENSEN BEACH, RECEYVCb
PINES, FL
MAR 0 5 2020
Subject: Wind Load Design Pressure Calculations (Components &CI llCWjn&e County, Permitting
Site Information General Calculation
Building Classification: enclosed Directionality Factor (Kd): 0.85
Wind Speed (Volt): 170 mph Gust-Effect Factor(G): 0.85
Exposure Category: d Internal Pressure
0.18
Roof Type: monoslope Coefficient (GC"*
±
Roof Slope (0): 1.2 deg Topographical Factor(K,t): 1.0
Mean Roof Height(h): 127.0 ft Velocity Pressure Exposure
K 1.49
Min. Building Dimension (L): 94.0 ft Coefficient ( n)�
Parapet>: 3 feet? No Velocity Pressure (qh): 93.94 psf
End Zone (a): 9.4 ft
ASD Method: P=0.6w
Mark Qty Elev.(ft) Size: W x H (in) Zone Shutter. Area (ft2) Kz (Kh) qz(q h) GCp+ GCP_ .Pressures (psf)
1 (1) 118.0 36.0 x 80.0 4 No 20.0 1.47 92.74 0.90 -0.90 +60.2/—60.9
A N
' o .
A
No PE82328
NOTES:Design is in accordance with ASCE 7-10(ASD method)and the Florida Building Code Sixth Edition(2017).Results—
are
esults are not valid for use unless approved via original signature and raised engineer seal of a PE from Engineering Express. Vdid Only With Raised/Stampe _
Results are based on contractor-supplied data and shall be field verified by others prior to use.Selection&installation of 73 Engine r Seal44
products shall be approved using these dimensions and pressures as verified by others. �0 S OF CV
•.t IOP..
Note:For openings to be properly rated in Zone 4,no part of the opening shall be within 9.4 feet of any building corner. Mon F'48e r %24\2020
This engineer has not field visited this location and if this cannot be clearly identified by others,the opening shall be re-
evaluated prior to installation of any fenestration. All other information provided above including mean roof height, Gordon I 8ttisto, P.E.
building minimum dimensions,opening sizes,&other supporting data was provided by others. For definitions of the PE82328
above terms,visit EngineeringExpress.com/Wiki" #9885