Loading...
HomeMy WebLinkAboutProduct Approval f —SEMMES 2160 SW Poma Drivel _ s Palm City, FL 34990 (774872-8034 Compliant with Florida Building Code 2017 (6th ed.) RECEIVED Compliant with Florida Product Approval Rule #61G 0-3 Compliant: Keystone Certifications MAR 0 4 "T"O ST. Lucie County, Permitting . Product: 1" Nailstrip 26GA Steel Standing Seam Roof Panel FBC Sec. 1507.4.2 Yield strength: 40ksi: Attached to Wood Deck with screws. 03 16" Coverage REWMWi CD FOR Corrosion Resistant Compliant: FBC Sec. 1507.4.3 CODE CO PUANCE Fastener for Method 1 Attachment # 10 x 1" Pancake Head wood sere Vqp n_9,8r` V NTY 3/16"thru 15/32" min. plywood deck Seam Adhesive: Bostik Chem Chalk 915, one component, polyurethane acllhii eC along male flange the full length of panel. Underlayment: To be compliant with FBC Sec. 1507 I Slope: Shall be in compliance with FBC Sec. 1507. 1.1 File Copy Install Details: Table A Allowable Loads METHOD 1 mainfield METHOD 2 perimeter DESIGN PRESSURE* -69.25 PSF -121.75 PSF FASTENER SPACING-ALONG ROWS 6" O.C. 6" O.C. r FASTENER SIZE: #10 #10 ' ADHEISIVE: NOT REQUIRED 3/8" BEAD (refer to S install details) i` Reference Data: HURRICANE TEST LABORATORY, L.L.C.#TST ID: 1527 Report#:0223-0313-02 TAS125-03(UL 58o-06/UL 1897-041) Report#: 0223-1015-06 TAS125-03(uL 58o-o6iuL 1897-041) EQUIVALENCY:UL 1897-04 IS EQUIVALENT TO UL 1897-12 TESTSTANDARD *DESIGNPRESSUREMARGIN OFSAFETY2.4 Certificate of Independence Locke Bowden,P.E.does not have,not will acquire a financial interest in,0jiV'd6V i oa6y manufacturing or distributing products I under this evaluation. Q• t� . �/'" '_ Locke Bowden,P.E.is not owned,operated,or controlled by any ctutek;ifGdistributing products under this report. R t, .� OF U on«/` - ���1 ly FL 20378.2 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Building Code(FBC)2017 61'ed.. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 Vh ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. Fastener. #10 Pancake-Head Screw Na1st ip'Roof Pani A-1� j /• iJrj k_wa"Bead ScannAdhe!lVe . .1 MT Wood Deck continuous along mate rib (Refer toTable"A') Wood Deck ----- -Integral Snap Lock Seam Adhesive Apply 318"lead Bostik Sealant entire length of panel f Tong male flange #10x1" Pancake-Head Screw I z.