HomeMy WebLinkAboutWind Load Calculation Property Information Building Information Owner: Will Wind Zone: 160 MPH. Address: 7 LaVilla Ct Exposure Category: B Ft Pierce,F134951 Minimum Building Dimension: 15 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) L Pressure(psf) 1 End 26.5 38 7 32.5 -43.5 2 Int 53 55 7 31.0 -33.7 3 V Int 53 55 7 _ 31.0 -33.7 4 End 74 63 7 30.0 -38.5 ._......-.._..... —.._.._—....-----._._...................-.___.__......_......................_..---._......-- - .----..........__ ...._._._............__...-----._.-...............--..... —--._.... -._.. 5 Int 26.5 38 7 32.5 -35.2 _ _-..........._-. .......... -- 6 Int 37 63 7 31.5 -34.2 7 Int 37 63 7 31.5 -34.2 8 End 26.5 38 7 32.5 -43.5 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1