HomeMy WebLinkAboutWind Load Calculation Property Information Building Information
Owner: Will Wind Zone: 160 MPH.
Address: 7 LaVilla Ct Exposure Category: B
Ft Pierce,F134951 Minimum Building Dimension: 15 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) L Pressure(psf)
1 End 26.5 38 7 32.5 -43.5
2 Int 53 55 7 31.0 -33.7
3 V Int 53 55 7 _ 31.0 -33.7
4 End 74 63 7 30.0 -38.5
._......-.._..... —.._.._—....-----._._...................-.___.__......_......................_..---._......-- - .----..........__ ...._._._............__...-----._.-...............--.....
—--._.... -._..
5 Int 26.5 38 7 32.5 -35.2
_ _-..........._-. .......... --
6 Int 37 63 7 31.5 -34.2
7 Int 37 63 7 31.5 -34.2
8 End 26.5 38 7 32.5 -43.5
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1