Loading...
HomeMy WebLinkAboutProduct Approval Sections from the Code RECEIVED Product Approval Method Method 1 Optic n D FEB � 7 Date Submitted 09/28/2017 Date Validated 09/29/2017 ST. Lucie County, Perrnitting Date Pending FBC Approval 10/03/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 16177.1 SH-8100 PVC Single Hung SH-8100 PVC Single Hung Impact Resistant window. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16177 R2 II CWS-812C.Ddf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:+70/-70 Evaluation Reports Other:SH-8100 PVC Impact,no sill anchors required.Safety FL16177 R2 AE EvalRePort812C.Ddf glazing required on outer lite above 30 ft. in HVHZ.Glass Created by Independent Third Party:Yes complies to ASTM E1300-04. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 45S,F.S.,please click here. Product Approval Accepts: m W: 99 HIRm Credit Card Safe CX FOR CODE Ct'/�® kf/f��_U�C TY ST.p LIJUM �:/� BC= File C®py SINGLE HUNG - LARGE MISSILE IMPACT GENERAL NOTES:1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED ��• WINDOW SYSTEMSTO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)AND 1900 SW 44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA,FLORIDA 34474 IN ASTM E 1996 PER THE FBC. WWW.CWS.CC 2.GLAZING OPTIONS:(SEE SHEET 2) 53 1/8"MAX.OVERALL FLANGE WIDTH 3.CONFIGURATIONS:"0/X". 8100 PVC 5177 MAX.UNIT WIDTH SINGLE HUNG 4.DESIGN PRESSURE RATING: IMPACT 4711/16"GLASS DLO -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/O9. A -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER z S INFILTRATION TEST PRESSURE AND GLASS TABLES H -w O cn W o'; -- -- - ASTM E-1300401/09. z zdz_ x Izz�w_ Ej 63• - -- __ I 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED 9 :Q W 3 Z O0 � MAX, IN THE DESIGN OF THIS PRODUCT.SEE SHEET 6 FOR ANCHOR z z M Q D:w O O OVERALL I I DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD OU OU�OF�I a E H� FLANGE ANCHOR CALCULATIONS. -cn z Z)D HEIGHT O Z c c=- "U- B I B 2613/16" 6.PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE Q F=z u co z O L z I GLASS DLO NOT REQUIRED. w � O H F-F z- I I I 7.ALL FRAMES AND VENTS FULLY WELDED.SMALL JOINT SEAM SEALANT w O c w>.p w Q w 66131314" I I USED AT FIXED MEETING RAIL AND JAMB. a z 2 a- 0 JO U)F OUN W HEIGHT 8.SERIES/MODEL DESIGNATION SH-8100. a H F-d w I 9.THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING: 10111111 I I X=OPERABLE SASH,0=FIXED SASH %t"PNOREW fTCi4 303116- I_ I 26 7/8" 10.SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR "00%,• �OENg'...op ' SASH `, I GLASS LOCATION. Z1/_ No 58201 ?�% HEIGHT X I DLO B 11.EXTERNAL WEEP SLOT=1/4"x 1-1/4"LOCATED 4"FROM BOTH ENDS. CX90; .NATE OF 4; 5 �i,�F Z O R 1 Q P'G�=O� 4 I s/ONAI-E. fflllll/1/fit,, LucasTurne 6 q r 451/16" 2017-09-22 GLASS DLO 13:36-04:00 4a 3/e„ 9/22/2017 MAX.SASH WIDTH LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: GENERAL NOTES AND TABLE OF CONTENTS ELEVATIONS DRAWN.BY: DATE: GENERAL NOTES&ELEVATIONS.....1 DESIGN PRESSURE BAT 06/18/12 GLAZING DETAIL.................................2 MAX. UNIT SIZE IMPACT RATING DWG#: REV.: SECTION VIEWS.................................3 RATING EXTRUSIONS&B.O.M........................4 CWS-812 C ANCHOR SCHEDULE&NOTES.........5 51-7/8"x61-3/4" +/-70 PSF LARGE MISSILE IMPACT SCALE: INSTALLATION DETAILS....................6 SHEET 1:15 1 OF 6 WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CWS.CC 8100 PVC SINGLE HUNG IMPACT zazo 1,- owo OO z W—iO W W ZOz7cW_ O=�zH ffi LL I-W�zO�.52 716"OVERALL INSULATED GLASS 7/8"OVERALL INSULATED GLASS z Z 2¢=w O 0 O 0 0 1<�F 118"ANNEALED OR TEMPERED VS"ANNEALED OR TEMPERED UO Z W z Z I-Z)U) 7/16"AIRSPACE 7116"AIRSPACE Z 0 Z O O Z O U - H--LLm0 LLZ T ¢�Ow—xO- 5116"LAMINATED GLASS 5/16"LAMINATED GLASS a: F-~1--Z 1!8"ANNEALED 1/8"ANNEALED W O D U O W t!1 W .090"PVB INTERLAYER BY DUPONT '090"PVB INTERLAYER BY DUPONT 0 W F-K W 1/8"ANNEALED 1/8"ANNEALED a a x a QUANEX DURASEAL QUANEX DURASEAL IG SPACER IG SPACER �.%0 t10f2EW�T.- 4 PURFECT GLAZE"H"OR SIKAFLEX 552 4 PURFECT GLAZE"H"OR SIKAFLEX 552 �GQr .G ENgF GPy lNo 58201 "'�11 14 1/2"GLASS BITE 14 1/2"GLASS BITE .k: 48 48 2ro, * 'ir-z STATE OF .4U: 3 yJ.4ONR1 QP*! ii C+ 1 ��'•Sy�oA�E����, FIXED LITE SASH LITE 9/22/2017 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: GLAZING DETAILS DRAWN BY: DATE: BAT 06/18/12 DWG ft: REV.: CWS-812 C SETTING BLOCKS PER FBC 2411.3.3.1 SCALE: SHEET 1:1 2 OF 6 INTERIOR WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CWS.CC 45 32 27 53 12 38 13 32 32 24 45 8100 PVC D _ 4 SINGLE HUNG o IMPACT 45 Q Z 3� <W-joZ3 0 0 F 0,0 `<Woo 1 e� Qoa w zao�z}or3m 14 I ?' 32 Z ZW�QF-��= 3 14 54 14 65 66 63 19 4 O 0 0 *<=O d SECTION B-B 0 z W—Z IIS--_U) Z 00(=j UA 54 NOTE:LEFT SIDE SHOWS FIXED SECTION VIEW, ¢ —Z o w p 0 W z RIGHT SIDE SHOWS SASH SECTION VIEW. ¢ �-O m U Zvi W OO KcoOwww LL 0- U) 14 -� 39 O WFO d02 of(o 40 a c e n� ad a 2 %Pp10RE W,T epi 1 92 INTERIOR JGQ�?.�.CEIJgFGP2�,: 48 v: No 5820162 =a' rce ' STATE 14 53 ONA"�N,,, 65 10 62 32 3z 3 9/22/2017 1s 6 LUCAS A.TURNER,P.E. 2 4 FL PE#58201 3 1239 JABARA AVE. 30 �oNORTH PORT,-1 34288 PH.941-380-1574 SHEET DESCRIPTION: SECTION A-A SECTION VIEWS DRAWN BY: DATE: BAT 06/18/12 DWG#: REV.: NOTE: ITEMS NOT SHOWN FOR CLARITY: CWS-812 C 20,25-26,36-37,44,51-52,55-56,64,67-68 SCALE: SHEET 1.2 3 OF 6 PARTS LIST FRAME REM PART DESCRIPTION VENDOR MATERIAL 31/6^ •�{ CONSTRUCTION 1 H-6031 Main Fr.,SH,w/Fig.,PVC,Head Mikron Vinyl I WINDOW SYSTEMS 2 H-6031 Main Fr.,SH,w/Flg.,PVC,Sill Mikron VinylI �f 1 15/16^--{ 3 H-6031 Main Fr.,SH,w/Flg.,PVC,L.Jb. Mikron Vinyl 1 I f--2 3n6"— OCALA,1900S44TH AVE. CAFLORIDA 34474 4 H-6031 Main Fr.,SH,w/Fig.,PVC,R.Jb. Mikron Vinyl 3 9 WWW.CWS.CC 6 S-1577 Impact Hook Keymark Alum 410 8 H-6027 Sash Meet.Rail,PVC Mikron Vinyl 211/16" 1 FK 9 H-1497 Reinf.Sash Meet.Rail Keymark Alum 1/ts" 1/16" 1!'s 8100 PVC 10 H-6028 Sash Bottom Rail,PVC Mikron Vinyl CORNER WELD(ALLSIDES) SINGLE HUNG 0 12 H-6004 Sash Side/Top/Bot.Rail Mikron Vinyl L1:6 13 S-1498 Reinf.S.B.R./S.S.RIMPACT 14 S-6064 Glz.Bd.,7/8" Mikron Vinyl PVC FRAME FLANGE-6031 PVC SASH BTM.RAIL-6028 PVC SASH TOP RAIL-6027 18 S-6013 Scm.Adapt.,w/Nib,PVC,Horiz. Mikron Vinyl J¢ Z 3: ¢Z 3� 19 S-6014 Scm.Adapt.,PVC,Vert. Mikron Vinyl 1 112„ F o W O Q w 0 0 20 S-6029 Sash Stop/Filler,PVC,Vert. Mikron Vinyl 3 w z 0 2 0'r Z' 1 3!16" F O ru-}0 0: 23 H-1699 Reinforcement,SBR Keymark Alum 7/6" 1 1 LL ~W z F-W g= 24 P-2190 Balance BSI 9n6 � O O F 0¢M W O O 25 P-3059 Sash Cam,PVC BSI Plastic 1116 1 5l6„ 2 118" 1116" SCREWED TOGETHER WITH Z 0(-0::)C Z 26 P-3046 Take Out Clip BSI SS FIXED MEETING RAIL ❑ Z- -Z Z)U- 27' P-37133 Lock,Impact,PVC Intedock 1/16" OUTERFRAME ¢ -U�Z O W O F -u-CoO z 28 P-4069 Keeper,Impact,PVC Interlock Zamac 1:8 } ¢ O W F F O- REINF.,IMPACT HOOK-1112 QQ Z 30 P-3215 Weep Cover w/Flap Gaer Plastic F o Q Y 5 O� 32 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab PVC SASH SIDE RAIL-6004 FIXED RAIL-1836 w LL rA w O�U)F- 37 P-4638 #8 x 2-1/2 PH Mod.Truss,Type A,TEK 2 Fastenal Steel nom. -=o W O rn 38 P-3768 1#8 x 0.625 Ph PH SMS Hub City Steel 1 5/16" 9116" W 1.-W Lu w U)39 P-4051 W#8 x 1.250 Ph FH TEK,Whit. Hub City Steel 1/2" 1 1/8" a o a 40 P-4264W#8 x 3/4 FH PH w/#6 Head,TEK,Wht. Hub City Steel 20 7Y 5/16" +'trrrrr' 44 P-3342 Seam Sealer,SM-5504 Schnee 7/8" 16 1 51'6" 045" 1!119 ,y,PNOEREVV ITG,Fj 45 P-3752 Cap Plug,1/2"Hole M&M Nylon 1n6" '/1s" ��GP;•�v SF•^•y.� 47 P-3438 Sikaflex 552 or Purfect Glaze"H" Sika/Henkel :z ? �! PVC SCREEN CATCH-6013 PVC FIXED RAIL COVER-6063 PVC SCREEN SUPPORT-6014 :�; No 58201 •t 1� 48 P-3352 Set.Blk.,85 Dur.,1/8"x 5/8"x 2"Lg. F.Lowe Rubber PVC SASH STOP-6025 �*; 51 P-3881 Temporary Lbl.(NFRC/DP) 52 P-3613 CWS Lbl.(logo) Pro Label 3/4",- 5/B' 1/q„ �9; STATE OF ,J" 53 Sash SEE SHEET GLASS 31a'-}- O . •�� 54 Fixed SEE SHEET GLASS ins ,T—I-� 3 Tr��� �q ��.c�Al R tp.C�` 56 P-3281 Spacer Duraseal T 13 15/16^ 1/16" 1" 716" �45jONA������, 62 P-3218 Screen Frame,Horiz. Allmelal I Alum i 1r16" .- L 1/16" l_ �rrrrrrnr+►� 63 P-3218 Screen Frame,Vert. Allmetal Alum REINF.S.B.R./S.S.R.R.-1498 REINF. BTM RAIL-1699 REINF.TOP RAIL-1497 PVC GLAZING BEAD-6064 64 P-3321 Screen Frame Comer Key Allmetal Plastic 65 P-3581 Screen Cloth,18 x 16 Fiberglass Belterwe Fiberglass y 66 P-3228 Screen Spline,.155 Dia.,Bilk. Dapa Vinyl 67 P-3029 Screen Pull Tab Summit Alum 9/22/2017 68 P-3033 Screen Spring,SS FI.Screen SS 70 P-3113 Screw Support for PVC T.Plastics Nylon LUCAS A.TURNER,P.E. FL PE#58201 71 H-1836 Alum.Fixed Rail Keymark I Alum Q 3116" 1239 JABARA AVE. 72 S-6063 Coker,Fixed Rail Mikron Vinyl O 73 S-1112 Reinforcement,Impact Hook Keymark Alum NORTH PORT,FL 34288 74 P-3541 #8x 1/2",Pan Head,TEK Fastenal Steel PH.941-380-1574 Ll 5/16" 112„ SHEET DESCRIPTION: LINE ITEMS NOT USED: 65" 3/16" 3^ BOM AND EXTRUSIONS 5,7,11,15-17,21-22,29,31,33-36,41-43,46,49-50,55,57-61,69 718" lits" "i�� .` T SCREW SUPPORT-3113 DRAWN BY: DATE: IMPACT HOOK BAT 06/18/12 S-1577 DWG#: REV,: CWS-812 C NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. SCALE: SHEET 1.2 4OF6 6 MAX.(TYP.) 17 MAX.O.C.(TYP.) WINDOW SYSTEMS 1900 SW 44TH AVE. 6"MAX.(TYP.) OCALA,FLORIDA 34474 -- -- -- WWW.CWS.CC I I SEE NOTE 2 8100 PVC MAXO.c. I I SINGLE HUNG (TYP.) IMPACT L O INSTALLATION ANCHOR(TYP.) I I 4 Z U)WOp ci 1 I F pw0 p W ZJOZ w-- - _ �y LL I,-W ZI-3ig= {T- ---`MTO PML c O 0 V a=oof 4"(TYP.)J I I p ZU, pZZFF-pW I I Q OZLJ(dZpUU F•—LL200"Z cD 1011 x ~ 0"�}5w�w MAX.O.C. Z W O�!n F (TYP.) O W EE I--0 0 } I ^ to W � 1 4 I Q. d d OF lVaRk, 4"(TYP.) NO ANCHORS REQUIRED IN SILL v' No 50201 '�1A ANCHORLAYOUT-(FLANGE) �9�: BTATE OF O�W� NOTES: 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.NO ANCHORS REQUIRED IN SILL. 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 6. 9/22/2017 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. BE PROTECTED TO PREVENT REACTION. FL PE#58201 1239 JABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 6. PH.941-380-1574 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. SHEET DESCRIPTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. ANCHOR SCHEDULE AND INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7.A MINIMUM CENTER-TO•CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. DRAWN BY: DATE: 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. BAT 06/18/12 DWG#: Rev,: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-812 C 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS),FMA/AAMA/WDMA 300(EXTERIOR DOORS) 1:15 5 OF 6 a TYPICAL HEAD ANCHORAGE MIN.EMBEDMENT WINDOW NEMS SYSTEP9S LL%J MIN.EDGE DIST. SEE TABLE 1 SUBSTRABY OTHERS SEE TABLE 1 1/4"MAX.SHIM SEE TABLE 1 OCA , L 4THAVE. CALAFLORIDA 34474 SUBSTRATE BY OTHERS WWW.CWS.CC SEE TABLE 1 MIN:EMBEDMENT PERIMETER SEALANT SEE TABLE 1 :IN.�EEIDGIE DIST. 81 OO PVC SEE TABLE 1 BYINSTALL NSIDEANDOUT SINGLE HUNG INSTALLATO SEETABLEI1 ANCHOR- IMPACT SEALANT BEHIND FLANGE BY INSTALLER 114"MAX.SHIM a Z ¢Z0 F- MwO Z W�0 ¢r Z W W ZOZ w_—F_ 0 ¢(A}?>.0w3m PERIMETER SEALANT LL F-W Z F-3:g 2 BY INSTALLER O O O -, W O Z INSTALLATION ANCHOR INSIDE AND OUT U U (DZ SEALANT BEHIND SEE TABLET 0 ZOO ZF-0U) FLANGE BY INSTALLER O Z U 2-Z(D U U } Q�0WO�Oz CONTINUOUS DOUBLE 3/16"BEADS OF B HORIZONTAL SECTION �' H-U F Z Ed TREMGLAZE U1600 SEALANT AROUND 6 TYPICAL JAMB ANCHORAGE W 0 0Ir>_-5 W O W PERIMETER AT ALL INDICATED POINTS Z fn W O�(n F- BETWEEN FRAME AND BUCK BY INSTALLER. D- al 0 (LO W O WF-OD- F a it > a 114"MAX.SHIM a(n FLANGE BY INSTALLER ON�PN03181ORESEALANT BEHIND W�T,t ...ENg�G�QZ i PERIMETER SEALANT MIN.EMBEDMENT BY INSTALLERSEE TABLE 1 v No 58201 '�A' INSIDEANDOUT o% STATE OF *40 SUBSTRATE BY OTHERS--/ 1'. '•'� P.'a�� SEE TABLE 1 —MIN.EDGE DIST. i��QS.4 O p 10,.•G\,�� SEE TABLE 1 � ONg1-E�.��� q VERTICALSECTION 6 TYPICAL SILL ANCHORAGE 9/22/2017 TABLE 1:APPROVED INSTALLATION FASTENERS LUCAS A.TURNER,P.E. SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. FL PE#58201 PERIMETER SEALANT 1239 JABARA AVE. CONCRETE(2.0 KSI MIN.) 3/16"ITW TAP CON 1-1/2" 1-1/8" BY INSTALLER NORTH PORT,FL 34288 HOLLOW OR GROUT-FILLED CMU(117 PGF MIN.) 3/16"ITW TAPCON 1" 2" INSIDEAND OUT PH.941-380-1574 C HORIZONTAL SECTION CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" V. 6 BOX FRAME INSTALLATION SHEET DESCRIPTION: GROUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 1-1/4" 2-1/2" HEAD AND SILL SIMILAR FOR BOX INSTALLATION 3116"ITW TAPCON INSTALLATION DETAILS 2X MIN.SOUTHERN PINE(G=0.55) 1.3/8" 716" OR ELCO ULTRACON FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, 2XMIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8" UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: DRAWN BY: DATE: 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILTI KWIK-FLEX OR[TW FULL THREAD BAT 06/18/12 (33 KSI YIELD MIN). TEKS SELF-DRILLING SCREW THRU 0.060" 7115 MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED DWG#: REV.: INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. CWS-812 C 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING 1 FULL THREAD 7/15, PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" SHOWN FOR FLANGE WINDOWS. SCALE: SHEET 1:2 6 OF 6