HomeMy WebLinkAboutProduct Approval, single hung 398 East Dania Beach',Blvd.
BUILDING DROPS L Suite 338
j� A Perfect Solution in Every Drop!
Dania Beach, FL 3,3004
Certificate of Authorization:29578 954.399.8478 PH
954.744.4738 FX
contact@buiIdingdrops�com
Product Evaluation Report
Of
Silver Line Building Products
Series 70— Extruded Vinyl Single Hung Window
(Impact Rated)
for
Florida Product Approval
FL# FL 715
ReportNo. 4806
Current Florida Building Code
Method: 1— D (Engineering Evaluation)
Category: Windows
Sub—Category: Single Hung
Product: Series 70 Single Hung Window
Material: PVC
Product Dimensions: See Installation Instructions,SWD011
Prepared for:
Silver Line Building Products
One Silverline Dr.
North Brunswick, NJ 06902 F
Prepared by:
Hermes F. Norero, P.E. Til ' O
Florida Professional Engineer#73778
Date: 12/15/2017 = -
)3 4u�:
Contents: *.I
G
Evaluation Report Pages 1-4 ��iSS/ONAU �
� %`�`
Digitally signed by Hermes F.Norero,P.E. Hermes" I WWI, P.E.
Reason:I am approving this documentFlorida No.73778
Date:2017.12.1818:31:30-05'00'
i ;
BUILDING DROPS FL#: FL19715
A Perfect Solution in Every Drop! Date: 12/15/2017
Report No: 4806
j
Certificate,
of Authorization:29578
Manufacturer: Silver Line Building Products
Product Category: Windows
Product Sub-Category: Single Hung
Compliance Method: State Product Approval Method (1)(d)
Product Name: Series 70 Single Hung Window
Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E.(FL#73778)for Silver Line
Building Products based on Method 1d of the State of Florida Product Approval, Florida Department
of Business and Professional Regulation-Florida Building Commission.
Hermes F. Norero, P.E.does not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process,of
the product named herein.
This product has been evaluated for use in locations adhering to the Current Florida Building
Code.
See Installation Instructions SWD011,signed and sealed by Hermes F. Norero, P.E. (FL#73778)for
specific use parameters.
Limits of Use:
1. This product has been evaluated and is in compliance with the Current Florida Building Code,
including the"High Velocity Hurricane Zone"(HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Chapter 16 of the Current Florida Building Code and does not require an impact resistant
covering.
4. Site conditions that deviate from the details of drawing SWD011 require further engineering
analysis by a licensed engineer or registered architect.
5. See Installation Instructions SWD011 for size and design pressure limitations.
Hermes F. Norero, P.E.
Florida No.73778
Page 2 of 4
i I
BUILDING DROPS FL#: FL19715
A Perfect Solution in Every Drop! Date: 12/15/2017
48 017
Certificate of Authorization:29578 Report No: 4806
i
j
Quality Assurance: The manufacturer has demonstrated compliance of window products in Accordance
with the Florida Building Code and State Rules for manufacturing under a quality
assurance program audited by an approved quality assurance entity through
Window and Door Manufacturers Association(FBC Organization#:QUA2515).
Performance Standards: The product described herein has been tested per:
• TAS 201-94
• TAS 202-94
• TAS 203-94
• ASTM E330-02
• ASTM E1886-05
i
• ASTM E1996-06/09/12
• AAMA/WDMA/CSA 101/I.S.2/A440-08
Referenced Data:
1. Product Testing performed by National Certified Testing Laboratories,Inc.
(FBC Organization#TST1589)
Report: Dated:
NCTL110-16327-1 08/13/2013
NCTL110-16327-2 11/05/2013
NCTL110-16327-3 08/13/2013
2. Quality Assurance
Window and Door Manufacturers Association
(FBC Organization#: QUA2515)
3. PVC profiles meet requirements of WDMA/HaliMark WD-61 in accordance
with AAMA 303
j
I
Hermes F. Norero, P.E.
Florida No.73778
Page 3 of 4
I,
`Y
//QA%
BUILDING DROPS FL#: FL19715
017
A Perfect Solution in Eve Drop! Date: 1 o: 48 6
Every p• Report No: 4806
Certificate of Authorization:29578
Installation: 1. Approved anchor types and substrates areas follows:
r
Nailing Fin Installation:
A. For two by(2X)wood frame substrate(Min.S.G.=0.55),use#8 PH Wood Screw OR11
Gauge Roofing Nails OR 10d Common Nails type wood frame anchors of sufficient
length to achieve minimum embedment of 1.50"into wood framing.
B.' For steel stud substrate(Min 18 Ga., Fy=33 ksi), use#8 TEK PH or HWH Screw type;steel
stud anchors of sufficient length to achieve minimum 3 threads penetration beyond steel
structure.
Through Frame Installation:
A. For two by(2X)wood buck substrate(Min.S.G.=0.55),use#10 PH Wood Screw type
installation anchors of sufficient length to achieve a minimum embedment of 1.50"into
the wood substrate.
B. For concrete(Min.f c=3000 psi)or masonry(Conforms to ASTM C90)substrate where
one by(1X), non-structural,wood bucking lis employed,use 3/16"diameter ITW HWH
Tapcon type concrete screw anchors of sufficient length to achieve minimum
embedment of 1.25" into concrete or masonry.
C. For concrete(Min.f c=3000 psi)or masonry(Conforms to ASTM C90)substrate where
wood bucking is NOT employed, use 3/16"diameter ITW HWH Tapcon type concrete
screw anchors of sufficient length to achieve minimum embedment of 1.25"into
concrete or masonry.
D. For steel stud substrate(Min 18 Ga., Fy=33 ksi),use#10 TEK PH or HWH Screw type
steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond
steel structure.
I,
Refer to Installation Instructions(SWD011)for anchor spacing and more details of the installation
requirements.
Design Pressure:
Refer to Installation Instructions(SWD011)for anchor spacing and more details of the installation
requirements.
Hermes F. Norero, P.E.
Florida No.73778
Page 4 of 4
4
,r
BCIS Home j Log In user Registration 1 Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links ; Search �.
��E Ind
..
Product Approval
USER:Public User -
e
Product Approval Menu>Product or Application Search>Application List
rz� �,Et�
Search Criteria Refine Search
II
Code Version 2017 FL# 19715.4
Application Type ALL Product Manufacturer ALL
Category ALL Subcategory ALL
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model,Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL'
Other ALL
Search Results-Applications
Ft# Type Manufacturer Validated By, Status
FL19715-R4 Revision Silver Line Building Products Corp. Locke Bowden P.E. Approved j
History FL#:FL19715.4 (334)300-1800
Model:Series 70 Model 2127 Single Hung i
Description: Extruded Vinyl Single Hung Window
Category:Windows
i
LSubcategory:Single Hung J
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
I
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),