Loading...
HomeMy WebLinkAboutProduct Approval, single hung 398 East Dania Beach',Blvd. BUILDING DROPS L Suite 338 j� A Perfect Solution in Every Drop! Dania Beach, FL 3,3004 Certificate of Authorization:29578 954.399.8478 PH 954.744.4738 FX contact@buiIdingdrops�com Product Evaluation Report Of Silver Line Building Products Series 70— Extruded Vinyl Single Hung Window (Impact Rated) for Florida Product Approval FL# FL 715 ReportNo. 4806 Current Florida Building Code Method: 1— D (Engineering Evaluation) Category: Windows Sub—Category: Single Hung Product: Series 70 Single Hung Window Material: PVC Product Dimensions: See Installation Instructions,SWD011 Prepared for: Silver Line Building Products One Silverline Dr. North Brunswick, NJ 06902 F Prepared by: Hermes F. Norero, P.E. Til ' O Florida Professional Engineer#73778 Date: 12/15/2017 = - )3 4u�: Contents: *.I G Evaluation Report Pages 1-4 ��iSS/ONAU � � %`�` Digitally signed by Hermes F.Norero,P.E. Hermes" I WWI, P.E. Reason:I am approving this documentFlorida No.73778 Date:2017.12.1818:31:30-05'00' i ; BUILDING DROPS FL#: FL19715 A Perfect Solution in Every Drop! Date: 12/15/2017 Report No: 4806 j Certificate, of Authorization:29578 Manufacturer: Silver Line Building Products Product Category: Windows Product Sub-Category: Single Hung Compliance Method: State Product Approval Method (1)(d) Product Name: Series 70 Single Hung Window Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E.(FL#73778)for Silver Line Building Products based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation-Florida Building Commission. Hermes F. Norero, P.E.does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process,of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions SWD011,signed and sealed by Hermes F. Norero, P.E. (FL#73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the Current Florida Building Code, including the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing SWD011 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions SWD011 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No.73778 Page 2 of 4 i I BUILDING DROPS FL#: FL19715 A Perfect Solution in Every Drop! Date: 12/15/2017 48 017 Certificate of Authorization:29578 Report No: 4806 i j Quality Assurance: The manufacturer has demonstrated compliance of window products in Accordance with the Florida Building Code and State Rules for manufacturing under a quality assurance program audited by an approved quality assurance entity through Window and Door Manufacturers Association(FBC Organization#:QUA2515). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E330-02 • ASTM E1886-05 i • ASTM E1996-06/09/12 • AAMA/WDMA/CSA 101/I.S.2/A440-08 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories,Inc. (FBC Organization#TST1589) Report: Dated: NCTL110-16327-1 08/13/2013 NCTL110-16327-2 11/05/2013 NCTL110-16327-3 08/13/2013 2. Quality Assurance Window and Door Manufacturers Association (FBC Organization#: QUA2515) 3. PVC profiles meet requirements of WDMA/HaliMark WD-61 in accordance with AAMA 303 j I Hermes F. Norero, P.E. Florida No.73778 Page 3 of 4 I, `Y //QA% BUILDING DROPS FL#: FL19715 017 A Perfect Solution in Eve Drop! Date: 1 o: 48 6 Every p• Report No: 4806 Certificate of Authorization:29578 Installation: 1. Approved anchor types and substrates areas follows: r Nailing Fin Installation: A. For two by(2X)wood frame substrate(Min.S.G.=0.55),use#8 PH Wood Screw OR11 Gauge Roofing Nails OR 10d Common Nails type wood frame anchors of sufficient length to achieve minimum embedment of 1.50"into wood framing. B.' For steel stud substrate(Min 18 Ga., Fy=33 ksi), use#8 TEK PH or HWH Screw type;steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond steel structure. Through Frame Installation: A. For two by(2X)wood buck substrate(Min.S.G.=0.55),use#10 PH Wood Screw type installation anchors of sufficient length to achieve a minimum embedment of 1.50"into the wood substrate. B. For concrete(Min.f c=3000 psi)or masonry(Conforms to ASTM C90)substrate where one by(1X), non-structural,wood bucking lis employed,use 3/16"diameter ITW HWH Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For concrete(Min.f c=3000 psi)or masonry(Conforms to ASTM C90)substrate where wood bucking is NOT employed, use 3/16"diameter ITW HWH Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25"into concrete or masonry. D. For steel stud substrate(Min 18 Ga., Fy=33 ksi),use#10 TEK PH or HWH Screw type steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond steel structure. I, Refer to Installation Instructions(SWD011)for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions(SWD011)for anchor spacing and more details of the installation requirements. Hermes F. Norero, P.E. Florida No.73778 Page 4 of 4 4 ,r BCIS Home j Log In user Registration 1 Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links ; Search �. ��E Ind .. Product Approval USER:Public User - e Product Approval Menu>Product or Application Search>Application List rz� �,Et� Search Criteria Refine Search II Code Version 2017 FL# 19715.4 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL' Other ALL Search Results-Applications Ft# Type Manufacturer Validated By, Status FL19715-R4 Revision Silver Line Building Products Corp. Locke Bowden P.E. Approved j History FL#:FL19715.4 (334)300-1800 Model:Series 70 Model 2127 Single Hung i Description: Extruded Vinyl Single Hung Window Category:Windows i LSubcategory:Single Hung J *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement I Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: mom ®'RR 0 Uedd Card i �