HomeMy WebLinkAboutBuilding Permit Application4UI APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date:
var-
DL
1. r.
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
PERMIT • • •
Ji
Permit Number:
Building Permit Application
Address: 8608 PENNY LN FT PIERCE, FL 34951
Property Tax ID #: 1301-608-0191-000-8
Site Plan Name: MATTHEW KARRAM
Project Name: MATTHEW KARRAM
REROOF SHINGLE
Commercial Residential X
Additional work to be performed under this permit —check all that apply:
Lot No. 3
Block No. 95
_Mechanical _ Gas Tank —Gas Piping _ Shutters Windows/Doors
_ Electric _ Plumbing _ Sprinklers _ Generator V% Roof J , Pitch
Total Sq. Ft of Construction: Sq. Ft. of First Floor: 195j-A
Cost of Construction: $ 23,500 Utilities: —Sewer —Septic Building Height: 15t
V.0!*
:.
Name t CW a riG-nr`
Name: WAYNE T BURNETT
Addre �►E N 1J m
Company: FHIA LLC
City: {t I l rC_t State:
Address: 3044 SW 42ND ST
Zip Code: �c�1-L`S� Fax:
City: HOLLYWOOD State: FL
Phone No. 8 [d MT-1
Zip Code: 33311 Fax:
E-Mail:
Phone No 954-792-4415
FIII in fee simple Title Holder on next page (if different
E-Mail
from the Owner listed above)
State or County License CCC1331144
If value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
If valve of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required.
=St RR EN ENTAL'C AISTRUCTIQN ""C N'LAW If
FdR ATM -
DESIGN ERENGINEER: _ NotApplicableMORTGAGE
COMPANY: Not Applicable
Name:
Name:
Address:
Address:
City: State:
City: State-
Zip: Phone
Zip: Phone:
FEE SIMPLE TITLE HOLDER: _ Not Applicable
BONDING COMPANY: Not Applicable
Name:
Name:
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
"111►ARMNG TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROYEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAW FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT_0
Signature of Owner/ Lesse /Contractor as Agent far Owner
ntractor/License Holder
SiWUO
STATE OF FLORIDA
SORID
COUNTY OF
CJ(3,j
The forgoing instrument was acknowledged before me
this T day of eA 2t& by
The forgoing instrum nt was acknowledged before me
this � day ArG�+ 20 i
A441 .
of by
'QL)U�
Name of person making statement.
Name of person Vnaking statement.
Personally Known c-"" OR Produced Identification
Personally Known 11 OR Produced Identification
Type of Identification 49YPt MANUELHERNANDEZ
Type of Identificat9l
Produced �'' ommission# GG 004918
Produc
Expires June 22, 2020
BandedThruBudgetNotery$erv1i;N
apy�0 ���ryPul]hCStets?Of
pf4
sFbride
Jusn Andrea Zurita
My Commission {;a S4iia2
(Signature of Notary P lic- State of Florida j
at of Public- o i a
Commission No. (Seal)
Commis I n No. {Seal)
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEATURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
RECEIVED
DATE
COMPLETED
ev. 277719
rage 1 01
Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved.
Property Identification
Site Address: 86os PENNY IN
Se+c/ TDwn/Range: 02/34SJ39E
Map ID: 13/02N
Zoning: RS-4 Count
Ownership
Matthew J Karram
8608 Penny LN
Fort Pierce, FL 34951
Legal Description
LAKEWOOD PARK -UNIT 8- BLK 95 LOT3 (MAP 13102N) (OR 3987-77)
Current Values
Just/Market Va.1ue:
$102,400
Assessed Value:
$81,566
Exemptions:
$50,000
Taxable Value:
$31,566
Property taxes are subject to change upon
change of ownership.
• Past taxes are not a reliable projection of future taxes.
The sale of it property will prompt the removal of all
exemptions, assessment caps, and special
classifications.
Taxes for this parcel: SLC Tax Collectofs Office
Download TRIM for this parcel: Download PDF
Parcel ID: 1301-608-0191-000-8
Account #: 2167
Use Type: 0100
Jurisdiction: Saint Lucie County
Total Areas
FinishedtU'nder Air (SF): 1,440
Gross Sketched Area (SF): 2.096
Land Size (acres): 0.22
Land Sizo (SF): 9,750
All information is believed to be correct at this time, but is subject to change and is provided without any warranty.
0 Copyright 2020 Saint Lucie County Property Appraiser. All rights reserved.
htq)s://www.pasle.org/RECard/ 2/27/2020
Florida Home ImprovemerltAssaCiate, Orlando Tek 407-472-83811
License NO- CGC 0614118014244818 OW I ry Fm 954-792-2170
8034St11npartDr.#401 • Oriand%FL32eog ' + Webslte:-WWW.FKAPRDDLICT5•COM
FI oRIDA l:malb INFO®FHAPRODUl7MX0M
HOME
Job ' f tMPROV MENT
IV ASSOCIATES
Replacement Rooting Contract
[dame2111-Home Phone: E'iiit ' fidS'&m
Address. ati State Zip
This Cantrad Isrnade and entenedinto thisIc 20� by and between Florida Home draprovemerrMAssodata Ma
a Flarlda Corporation r Contrsctor•ar'FHA'l and owner (s)named above of the residence located at the address listed above ('Owner•!.
Thl-W011P Contractor agrees to perform described below
1) Remove existing roofco mring and at aessorles
2) Prepare roof as necessary to Melva installation of new roofing materials
3) Roof Type: Shingles Tile Roof Metal Roof Flat Roof
4) Remove: Shingles--9�,Sq. Tile Roof-----Sq. Metal Roof Sq. Fiat Roof-----5q.
5) Remove: Gutters L17 Lineal Feet Remove and re -hang
6) Install: Shingles_ I Sq. TlieRaaf 5q. Metal Puaf Sq. FlatRoof-------3q.
7) Install: Gutters Lineal Feet
B) Install:ShingieType:
9) InMIL Color -` r/
10) Install, VentType: Ridge Roll Box Vent
11) Install: Underlavment Farr K.-Z. n-6 I
War-ChKk all that apply to this contract" —
Lifetime shingle coverage from manufacturer �j �Tear-off 50years from manufacturer
Nan -prorated coverage 5p years from manufacturer ` plsposal 50 years from manufacturer
�I Materials and labor 50years from manufacturer _ Workmanship 25 years from manufacturer
AddwRml arartc
ftricNat to be dons: _
schedule :Contractar!FWcommencethe work within 7 daysaftertheexecution ofthecontract( the'Comrnenaementpateland
shall endeavor to complete all work hereunder within days aft the Commencement Date.
TheTWAL IWCE for all Labor and Materials I including mw appicable, dbcount) US Z*341 •O
Down Payment Ia S
Balance payable Is S
Contractor wIll provide to Owner a Finalwa[verand Release ofUen andi ontractoes Reel A7rdavtt to Owner. subsWrtlapyshnllar to the forms Included In
chapter713. FkuidaStatues�2M
docleone n(YES ortla)oarelects toapply forfinancingoftheabovestated lump sumamountIfyesisdnded.see fiancingagreement and related
Nntice to the Owner, lfftand ng Fs betng obtained by Owner -
a) Do not sign d4zRome lmprovemantContract iincluding BnmcingdocumrnlslinbhmL
b) Y"ansaMidedtoacopy oftheeonemce■ttWUmeyuusigs.iieepnteprotect ymulegairlghts.
c) 7MA"andaldocumentsattachedtothiFHornelmprovemerltCantradmaycontainamortageorotherwisecmftnlienonyourprop"het
could befor4osed on if you do act pay. Be sure yea understand all provision of fhetentmStmad Gnondaidocuments beftuayou signs.
amen waiver tact contains the entimcontract ofthepartlas.ltMAY not berh"edorally but onybyasigned change orderorothexWd ten
bi' nypartypfabreachofanyprovhfonofthlscontract"IlActoperateorbetonstmedmawaivvDfanysatuequentJam by any party. All transadlpnsare subject torevlewand apprMW by theInstallatlonandCreditdepartmentswhomaymncetandreiunubseqd any down
payment.
IN-VM 4F.thepattleshenetohave exenrtedthis cnniraMuoclarse4asofthe day andyearfirsta
cancel
nIthis contract eH'mpdwhave wdtten.you the buyerrnry
for a»y e>tpiar»nlon Df this riphL famrdnlglstonOn rfierthedateoFthlstransaWonseeattachednottoeofcan,,d Uonform
�
Dwnrr/��
. contractor. -r 15 /'�
AAAGrr Q. 7C �111�1L,14�� $v: �o6r.: r`—,r•a.�t �kv
sw.. oY. er ram - �Gda
Home Owners Assadatfon Name: Phortelf: Z
yES lY J NO( 1 [atrtmunity Name f � Q1�
Scanned with CamScanner
''crida Home Improvement Associates Orlaadalbl.407-472-VAI
11034 S No' CCC 13110461/ R844818 Fm 954-742-2170
4 SynPo" Dr. 0401 . Orlando,FL 328og Webslte: WWWFHAPRDDUM.CDM
as Emaik iNFO@FHAPRODUCTS.COM
FLOPIPA
j HOHE
�O j t C� ' ASSOIMPRC ATES T /
{ !! <, Replacement Roofing Worksheet
Name: f j-kZC/ `'��l49kAJ Home Phone. AM'SU-)Cell-
Address
T1111iffork, Check all that apply to this contract:
City % State Zip
. Remove eAsting roof covering ( NOTE: removed Items are likely to he damaged and cannot be reused?
Replace rotted ar damaged roof decking as applicable to this project
Repair or replace existing fascia board as applicable to this project
Re nail existing mdf deck to meet current Florida Building codes
--_ Install new 15I6 felt underlayment as appbcableto this project (certain warranties may not apply)
Install new 3011; fait underlayment as applicable to this project
Install CertainTeed Diamond Deck superhigh performance underlayment as applicable to this project
Apply AWcemerrt and membrane atoll roof penetrations (certain warranties maynotapply)
Install CertaInTeed MnterGuard high performance underlayment at all roof penetrations
Install CertainTeed standard three tab starter shingles as applicable to this project (certain warranties may not apply)
Install CertalnTeed Swift Start high performance startershingle3 as applicable to this project
_ Install standard drlpedge around perimeter of roof as applicable to this project (certain warranties may not apply)
Install heavy gaugehigh performance drip edge around perimeterof roof as appihable to this project
Install standard valley metal In valleys as applicable to this project (certain merranties may not apply)
Install CertainTeed WrnterGuard high performance underlayment In valleys asapplicableto this project
Install new roofventilat(on to replace existing Icertain warranties may not apply)
Install new certainTeed high perfonnan oe ridge Yentas applicableta this project
Install new standard three tab CartainTsed shingler Color: rift— (certain warranties may not apply)
—Install new CertaInTeed Landmark Pro shingles: Color. ,M.�Ds 6119d
_ Install new standard Hip and Ridge Accessories as applicable to this project (certain warranties may not apply)
Install new[ertain%ed Hip and R1dgeAccessorles as applicable to this project
Cleanup and haul away all materials and debris from roof work
f Check all that apply to this contract:
Lifetime shingle coverage from manufacturer Tear -off 50 years from manufacturer
Non -prorated coverage 50 years from manufacturer Disposal 50 years from manufacturer
Materials and labor 50 years from manufacturer Workmanship 25 years from manufacturer
Total List Price: $ 2' r
Customer Name; Date•
Customer Name.
Date;
Scanned with CamScanner
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form
Maser Permit No. Process No.
Conbsctor's Name FH IA LLC
Job Address 8608 PENNY LN, FORT PIERCE FL 34951
ROOF CATEGORY
0 Low Slope 0 Mechanically Fastened Tile 13 MortodAdheshre Set Tile
0 Asphaltic 0 Metal PoneliShingles 0 Wood Shingwahakes
Shingles 154 PrescripAre there
tive 13UR�RAS Gas Vent Stacks?
Yes ❑ Nod(
ROOF TYPE
Type: Natural ❑ LPGXU
C] New Roof Re -Roofing D Recovering 0 Repair El Maintenance
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) Seep Sloped Roof Area (SF) Total (SF)
0 1454 1454
SeRIgn I [Road P� Ian)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow
scuppers and overflow drains. include dimensions of sections and levels, clearly
IdentlW dimensions of elevated oressu a zones and location of oaraoets.
SHINGLES
SHINGLES
14
N/A
e
N + s
w
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form
Sectl�on_D Meeo SIODed Roof fSSys_�eml
SIGOR Slo ed Roof S stem Description
Deck Type:6. 5/8 PLYWOOD
Roof Slope:
3 •12
Ridge Ventllation?
yes
Mean Roof Height: 150
I DIAMOND DECK W/20" HEADLAP ASTM D 226 TYPE II I
N/A
N/A
Type $ Spacing: -1 4 RS COIL NAIL 6 " OC LAP
1121, OC FIELD
fesive Type N/A
yPe Cap Sheet: N/A
OOf Covering: CERTAINTEED
LANDMARK PRO SHINGLES
Type & Size Drip
ge. 3" GALV 26 Ga
3/20/2019
CERTAINTEED CORP, TFWZ.R684 - UL Product Spec
UL PRODUCT CATEGORY SHINGLES
Prepared Roof -covering Materials
See General Information for Prepared Roof -covering Materials
CERTAINTEED CORP R684
ROOFING PRODUCTS GROUP
20 MOORES RD
MALVERN, PA 19355 USA
Asphalt glass mat shingles designated "Highland Slate", "Highland Slate IR", "Presidential Solaris"
"Presidential Shake", "XT 25", "XT 25 Metric", "XT 30", "XT 30 Metric", "Hatteras", "Carriage House",
"Grand Manor", "Landmark", "Genesis", "Esten", "Landmark Pro", "Architect 80", "Landmark Solaris",
"Landmark Solaris Gold/Platinum", "Landmark Premium", "Landmark TI_", "XT 30 IR", and Patriot for
installation as Class A prepared roof coverings. Suitable for installation on minimum 3/8 in. thick
plywood decks. Also Classified in accordance with ASTM D3161, Class F. Also Classified in
accordance with ASTM D3462. Also Classified in accordance with CSA-A123.5.
Asphalt glass mat shingles designated "CT 20", "CT 20 Metric", "Landmark IR", "Landmark
Solaris", "Landmark TI_ Solaris", "Landmark Solaris IR", "Landmark Pro Solarls", "Arcadia Solaris"
and "Swiftstart" for installation as Class A prepared roof coverings. Suitable for installation on
minimum 3/8 in. thick plywood decks. Also Classified in accordance with ASTM D3161, Class F. Also
Classified in accordance with ASTM D3462.
Asphalt glass mat shingles designated, "Belmont", "Belmont IR", "Arcadia" for installation as Class
A prepared roof coverings. Suitable for installation on minimum 3/8 in. thick plywood decks. Also
Classified in accordance with ASTM D3161, Class F. Also Classified in accordance with ASTM
D3462. Also Classified in accordance with CSA-A123.5.
Asphalt glass mat shingles designated, "Presidential Shake IR", "Presidential Shake TL",
"Presidential Shake TL Solaris" for installation as Class A prepared roof coverings. Suitable for
installation on minimum 3/8 in. thick plywood decks. Also Classified in accordance with ASTM D3161,
Class F or Class A. Also Classified in accordance with ASTM D3462. Also Classified in accordance
with CSA-Al23.5.
Asphalt glass mat shingles designated "Independence" for installation as Class A prepared roof
coverings. Suitable for installation on minimum 3/8 in. thick plywood decks. Also Classified in
accordance with ASTM D3161, Class A or Class D. Also Classified in accordance with ASTM D3462.
Also Classified in accordance with CSA-A123.5.
Asphalt glass mat shingles designated "Firehalt" or "Firescreen" for installation as Class A
prepared roof coverings. Suitable for installation on minimum 3/8 in. thick plywood decks. Also
Classified in accordance with ASTM D3161, Class A.
http:llproductapec.ul.com/document.php?id=TFWZ.R684 113
3/20/2019
CERTAIMTEED CORP, TFWZ.R684 - Ui_ Product Spec
Asphalt glass mat shingles designated "Presidential Starter", "Presidential Starter IR" and "High
Performance Starter" for installation as Class A prepared roof coverings. Suitable for installation on
minimum 318 in. thick plywood decks. Also Classified in accordance with ASTM D3462. Also
Classified in accordance with ASTM D3161, Class F. Also Classified in accordance with CSA-A123.5.
Asphalt glass mat shingles designated "Universal Starter" for installation as Class A prepared roof
coverings. Suitable for installation on minimum 3/8 in. thick plywood decks. Also Classified in
accordance with ASTM D3462. Also Classified in accordance with ASTM D3161, Class F.
Asphalt glass mat shingles designated "CT 20", "XT25", "XT30", "Hatteras", "Highland Slate",
"Carriage House", "Grand Manor", "Shadow Ridge", "Ridge", "Shangle Ridge", "Landmark",
"Genesis", "Esten", "Landmark Pro", "Architect 80", "Landmark Premium", "Presidential Shake",
"Presidential Shake IR", "Presidential Shake TL", "Landmark TL", "Firehalt", "XT 30 IR",
"Independence", "Patriot", "Landmark IR", "Landmark Solaris", "Landmark Solaris", "Firescreen",
"Mountain. Ridge", "Cedar Crest IR", "Presidential IR", "Presidential Solaris", "Landmark Solaris",
"Landmark IR", "Highland Slate IR" and "NorthGate" for installation as Class A prepared roof covering
when used with minimum Type 30 underiayment over existing wood shingle roof.
Asphalt glass mat hip and ridge shingles designated "Mountain Ridge" for installation as Class A
prepared roof coverings and as wind resistant roof coverings. Wind resistance has also been
evaluated in accordance with ASTM D3161, Class F. Also Classified in accordance with ASTM.
D3462. Also Classified in accordance with CSA-A123.5.
Asphalt glass mat hip and ridge shingles designated "Solaris H&R Accessory", "Solaris
Accessory", "Solaris Accessory IR", "Shangle Ridge", "Shadow Ridge", "Ridge" and "Cedar Crest" for
installation as Class A prepared roof coverings and have also been evaluated in accordance with
ASTM D3161, Class F when BASF Sonnolastic NP 1 adhesive or Henkel PL® Polyurethane Roof &
Flashing Sealant, applied as specified in manufacturer's application instructions." Also Classified in
accordance with ASTM D3462. Also Classified in accordance with CSA-A123.5.
Modified asphalt glass fiber mat shingles designated "NorthGate" for installation as Class A roof
covering. Suitable for installation on minimum 3/8 in. thick plywood in combination with minimum one
ply "Shingle -Mate" or Type 15 or Type 30 underlayment. Also Classified in accordance with ASTM
D3161, Class F. Also Classified in accordance with ASTM D3462. Also Classified in accordance with
CSA123.5.
Modified asphalt glass fiber mat hip and ridge shingles designated "NorthGate Ridge" and
"NorthGate Accessory" Metric for installation as Class A roof covering. Also Classified in accordance
with ASTM. D3161, Class F. Also Classified in accordance with ASTM D3462. Also Classified in
accordance with CSA123.5.
Asphalt coated glass fiber shingle, designated "Shadow Ridge".
Last Updated on 2019-01-23
The appearance of a company's name or product in this database does not in itself assure that
products so identified have been manufactured under UL's Follow -Up Service. Only those products
bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service.
Always look for the Mark on the product.
http:llproductspec.ul.00m/document.php?id=TFWZ.R684 213
3/20/2019
CERTAINTEED CORP, TFWZ.R684 - UL Product Spec
UL permits the reproduction of the material contained in the Online Certification Directory subject to
the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems,
and/or Certifications (files) must be presented in their entirety and in a non -misleading manner,
without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online
Certifications Directory with permission from UL" must appear adjacent to the extracted material. In
addition, the reprinted material must include a copyright notice in the following format: "OO 2019 UL
LLC".
UL and the UL logo are trademarks of UL LLC C 2019 All Rights Reserved.
http:llproductspec.ul.com/document.php?id=TFWZ.R684 313
Ml® MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eav�economy
CertainTeed Corporation
20 Moores Road
Malvern, PA 19355
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Landmark, Landmark Pro, Landmark Pro/Archetect 80, Landmark Premium, Landmark Impact
Resistant, Landmark Solaris, Landmark Pro Solaris and Landmark Solaris Gold/Platinum
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 17-1211.08 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy Semino 8
—� NOA No.: 18-1114.02
MIAMHUMECOUNTY Expiration Date: 02/28/22
. • ,4mApproval Date: 05/09/19
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Cates Roofing
Sub -Category: Asphalt Shingles
Materials Dimensional
Deck Type: Wood
SCOPE
This acceptance is for CertainTeed Landmark, Landmark Pro, Landmark Pro/Architect 80, Landmark
Premium, Landmark Impact Resistant, Landmark Solaris, Landmark Pro Solaris and Landmark Solaris
Gold/Platinum Shingles as manufactured by CertainTeed Corporation described in Section 2 of this Notice of
Acceptance.
PRODUCT DESCRIPTION:
Test
Prndnrt
Certainteed Landmark
Manufacturing Locations #1, 2, 3, 4, 5, 6, 7, 8, 9,
13 %4" x 38 %"
TAS 110
A heavy weight, dimensional
10
asphalt shingle.
Certainteed Landmark Pro
A heavy weight, dimensional
Manufacturing Locations #1, 3, 4, 5, 6, 9, 10
13'/4" x 38 3/a"
TAS 110
asphalt shingle.
Certainteed Landmark Premium
A heavy weight, dimensional
Manufacturing Locations #1, 3, 4, 5, 6, 8, 9
13'/4" x 38 3/4"
TAS 110
asphalt shingle.
Certainteed Landmark Impact Resistant
I A heavy weight, dimensional
Manufacturing Locations #7
13 %4" x 38 3/4"
TAS 110
asphalt shingle.
Certainteed Landmark Pro/Architect 80
A heavy weight, dimensional
Manufacturing Locations #8
13'/4" x 38 3/4"
TAS 110
asphalt shingle.
Certainteed Landmark Solaris
A heavy weight, dimensional
Manufacturing Locations #8, 9
13'/a" x 38 3/4"
TAS 110
asphalt shingle.
CertainTeed Landmark Pro Solaris
Manufacturing Location #9
131/4" x 38 3/4"
TAS 110
A heavy weight, dimensional
asphalt shingle
Certainteed Landmark Solaris Gold/Platinum
A heavy weight, dimensional
Manufacturing Locations # 8
13'/4" x 38 3/a"
TAS 110
asphalt shingle.
Accessory Shingles
Accessory shingles for hip, ridge
various
proprietary
and starter strip applications.
XK. T
i•iHl\ ur HL 1 unuN ky 11VC.A 11L11V b:
1. Peachtree City, GA
2. Ennis, TX
3. Oxford, NC
4. Shakopee, MN
NOA No.: 18-1114.02
MIAMMMDE COON W Expiration Date: 02/28/22
`"' • ' Approval Date: 05/09/19
Page 2 of 7
5.
Avery (Milan), OH
6.
Norwood, MA
7.
Shreveport, LA
8.
Portland, OR
9.
Wilmington, CA
10.
Jonesburg, MO
EVIDENCE SUBMITTED:
Test Agency, Test Identifier Test Name/Report Date
PRI Asphalt Technologies, Inc.
PCTC-01-02-01
TAS 100
01/12/01
CTC-006-02-01
TAS 100
11/12/02
CTC-092-02-01
TAS 100
02/23/12
CTC-091-02-01
TAS 100
02/21/12
CTC-090-02-01
TAS 100
09/02/11
CTC-087-02-01
TAS 100
07/07/11
CTC-086-02-01
TAS 100
07/07/11
CTC-101-02-01
TAS 100
10/05/11
CTC-102-02-01
TAS 100
10/05/11
CTC-109-02-01
TAS 100
01/18/12
CTC-106-02-01
TAS 100
11/02/11
CTC-105-02-01
TAS 100
10/31/11
CTC-089-02-01
TAS 100
07/18/11
CTC-088-02-01
TAS 100
07/18/11
CTC-213-02-01
TAS 100
05/20/14
CTC-212-02-01
TAS 100
05/21/14
CTC-207-02-01
TAS 100
05/20/14
CTC-206-02-01
TAS 100
05/20/14
CTC-110-02-01
TAS 100
02/13/12
CTC-109-02-01
TAS 100
02/13/12
CTC-288-02-01
TAS 100
09/27/ 16
CTC-333-02-01
TAS 100
11/08/17
Underwriters Laboratories, Inc.
94NK9632
Wind uplift resistance TAS 107
11/30/00
R684
UL 790
04/02/01
02NK42448
Wind uplift resistance TAS 107
11/08/02
09CA28973
Letter
07/23/09
l ICA59020
TAS 107/ ASTM D3161
01/25/12
1 INK07864
TAS 107/ ASTM D3161
09/29/11
07CA26696
TAS 107/ ASTM D3161
09/21/07
I ICA38844
TAS 107/ ASTM D3161
01/28/12
11 CA38844
TAS 107/ ASTM D3161
01/27/12
06CA28237
TAS 107/ ASTM D3161
09/22/06
IONK17366
TAS 107/ ASTM D3161
01/04/1 l
4786334383
TAS 107/ ASTM D3161
05/28/14
4786307351
TAS 107/ ASTM D3161/ASTM D 3462
05/13/14
NOA No.:
18-1114.02
MIAM14OMECOUNTY
Expiration Date: 02/28/22
` "' • '
Approval Date: 05/09/19
Page 3 of 7
I INK08333
ASTM D3462
05/15/12
11NK08333
ASTM D3462
04/15/12
I INK07864
ASTM D3462
09/29/11
11NK08333/Letter
ASTM D3462 / UL790
11/05/12
11NK08333/Letter
ASTM D3462 / UL790
11/05/12
11NK08333/Letter
ASTM D3462 / UL790
11/05/12
12NK13474
ASTM D3462 / UL790
05/27/13
4786325932
ASTM D3462 / UL790
04/04/14
4787011023
ASTM D 3462
08/01/15
1 ICA38844
TAS 107/ ASTM D3161
01/26/12
06CA02648
TAS 107/ ASTM D3161
02/23/06
4787084802
TAS 107/ ASTM D3161
03/14/16
4787852839
ASTM D3462
03/24/17
4787011023
ASTM D3462
08/01/15
4788368979
ASTM D3462
10/30/18
4787592174
ASTM D3462
10/21/16
LIMITATIONS:
I. Fire classification is not part of this acceptance; refer to ,i current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit
in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
INSTALLATION:
1. Shingles shall be installed in compliance with Roofing Application Standard RAS It 5.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W, attached.
5. Nailing shall be in compliance with Detail W, attached.
NOA No.: 18-1114.02
MAMIHOXWE COUNTY Expiration Date: 02128/22
` ' ' ' • ' Approval Date: 05/09/19
Page 4 of 7
LABELING:
1. Shingles shall be labeled with the Miami -Dade Product Control approved seal as seen below or the wording
"Miami -Dade County Product Control Approved".
BUILDING PERMIT REQUIREMENTS:
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 18-1114.02
Expiration Date: 02/28/22
Approval Date: 05/09/19
Page 5 of 7
SHINGLE LAYOUT
Eaves
LANDMARK, LANDMARK PRO, LANDMARK PRO/ARCHITECT $O, LANDMARK PREMIUM,
LANDMARK IMPACT RESISTANT, LANDMARK SOLARIS, LANDMARK PRO SOLARIS AND
LANDMARK SOLARIS GOLD/PLATINUM
NOA No.: 18-1114.02
Expiration Date: 02/28/22
Approval Date: 05/09/19
Page 6 of 7
DETAIL B
i _ 38 3/4"
VV10E �
NAILING
AREA
N a i ling area far "low L stand a rd slopes (from 2:12 to 21:12'
Nail hatween upper& lower nail lines.
1"
12" 14 3/4" 12"
dle—
5 fir.
Exposure
LANDMARK, LANDMARK PRO, LANDMARK PRO/ARCHETECT 80,LANDMARK PREMIUM,
LANDMARK IMPACT RESISTANT, LANDMARK SOLARIS, LANDMARK PRO SOLARIS AND
LANDMARK SOLARIS GOLD/PLATINUM
(LOW AND STANDARD SLOPE)
Mailing area for "steep" slopes (greater than 21:12)
Nail between bottom 2 nail lines.
12"14 3/4"
5 5/8"
Exposure
LANDMARK, LANDMARK PRO, LANDMARK PRO/ARCHETECT 80, LANDMARK PREMIUM,
LANDMARK IMPACT RESISTANT, LANDMARK SOLARIS, LANDMARK PRO SOLARIS AND
LANDMARK SOLARIS GOLD/PLATINUM
(STEEP SLOPE)
END OF THIS ACCEPTANCE
NOA No.: 18-1114.02
WMIAMMADECOUNTYM Expiration Date: 02/28/22
• •. . Approval Date: 05/09/19
Page 7 of 7
NIANt
14IIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 209
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175 2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www-mismldade.aov/monomv
CertainTeed Corporation -'
1400 Union Meeting Road
Blue Bell, PA 19422
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their j urisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Shangle Ridge, Shadow Ridge, Hatteras Accessory, Presidential Accessory, and
Cedar Crest Hip and Ridge Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miarni-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA# 12-061 l .02 and consists of pages 1 through 9.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0824.05
Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 1 of 9
ROOFING ASSEMBLY .APPROVAL
Cateaory•
Roofing
Sub -Cate o :
Asphalt Shingles
Materials
Laminated
Deck Tyne:
Wood
SCOPE
This approves CertainTeed Shangle Ridge, Shadow Ridge, Hatteras Accessory, Presidential Accessory and Cedar
Crest Hip and Ridge Shingles as manufactured by CertainTeed Corporation (PA) and described in Section 2 of this
Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
Shangle Ridge 12" x 18" TAS 110 A pre -assembled, double layer hip and
Manufacturing Location(s) # 1 ridge fiberglass reinforced asphalt shingle
with an 8" exposure.
Shadow Ridge 12" x 12"
Manufacturing Location(s) # 1, 2, 3,4
Hatteras Accessory 12" x 18"
Manufacturing Location(s) # I
Presidential Accessory 12" x 1217
Manufacturing Location(s) # .2
Cedar Crest 12" x 12"
Manufacturing Location(s) # I
TAS 110 A pre -assembled hip and ridge fiberglass
reinforced asphalt shingle with an 5"
exposure.
TAS 110 A pre -assembled hip and ridge fiberglass
reinforced asphalt shingle with an 8"
exposure.
TAS 110 A pre -assembled hip and ridge fiberglass
reinforced asphalt shingle with an 5"
exposure.
TAS 110
PRODUCTS MANUFACTURED BY OTHERS
Product Product Description
Any approved sealant with a current Miami Sealant
Dade NOA
A pre -assembled hip and ridge fiberglass
reinforced asphalt shingle with an 8"
exposure.
Size Manufacturer
various Any approved manufacturer
(with a current Miami Dade NOA)
Any approved adhesive with a current ASTM C920, Type S, various Any approved manufacturer
Miami Dade NOA Grade NS, min Class 25 (with a current Miami Dade NOA)
NOA No.: 17-0824.05
Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 2 of 9
MANUFACTURING LOCATION
1. Oxford, NC.
2. Shakopee, MN.
3. Avery, OH
4. Norwood, MA.
EVIDENCE SUBMITTED
Test Agen ,v
Test Identifier
Test Name/Reno
Date
PRI Asphalt Technologies, Inc.
CTC-028-02-01
ASTM D 6381
08/06/07
CTC-021-02-01
TAS 100(A)
05/16/06
CTC-029-02-01
TAS 100(A)
08/06/07
CTC-030-02-01
TAS 100(A)
08/06/07
CTC-020-02-01
TAS 100(A)
05/16/06
CTC-072-02-01
TAS 100(A)
02/10/11
CTC-334-02-01
TAS 107
08/29/17
CTC-330-02-01
TAS 107
08/27/17
CTC-310-02-01
TAS 100(A)
0581117
CTC-311-02-01
TAS 100(A)
05/31/17
CTC-312-02-0I
TAS 100(A)
05/31/17
CTC-315-02-01
TAS 100(A)
06/19/17
CTC-314-02-01
TAS 100(A)
06/19/17
Underwriters Laboratories, Inc.
07CA30825
ASTM D 3161
08/06/07
R684
ASTM D 3462
08/04/04
R684
ASTM D 3462
08/05/04
IOCA44960
ASTM D 3462
11/11/10
IOCA44960
ASTM D 3161
11/11/10
4787855169
ASTM D 3161/3462
07/27/17
4787855164
ASTM D 3161/3462
06/27/17
4787867612
ASTM D 3161/3462
07/26/17
4787855162
ASTM D 3161/3462
06/26/17
4787955167
ASTM D 3161/3462
06/30/17
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
INSTALLATION
1. Ridge Cap Shingles shalt be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Layout Details herein
NOA No.: 17-0824.05
Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 3 of 9
LABELING
1. Ridge Cap Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade
County Product Control Approved"-
MIAMi-Dwu2 COUNTY
I,...I
BUILDING PERmn REQUIREMENTS
Application for building permit shall be accompanied by copies of the foIIowing:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
1�
Fklm the
left side
FIRST
.LAYOUT DETAILS
SHANGLE RIDGE
LEFT
Exposures Rem* tape
from the rigt side
and tstan
SECOND
RIGHT
NOA No.: 17-0824.05
Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 4 of 9
SHADOW RIDGE
HATTERAS ACCESSORY
NOA No.: 17-0824.05
Mu1MIlD Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 5 of 9
PRESIDENTIAL ACCESSORY
CEDAR CREST
Sealant
4" Starter
NOA No.: 17-0824.05
MIAMI-SWD; COUNTY Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 6 of 9
1/4" wide bead of adhosive, 7" long,
314"Am from side edge of sap shingle
NAILING DETAILS
SHANGLE RIDGE
12•
1`
6 rr
of
(219
7'
(26 MM)
(457 mm)
Nailing pattern all applications - two naps per shingle.
SHADOW RIDGE
1A" vw 1de bead of adhes lye, 3'-3 1!2' long,
3l411-11" from side edge of cap $hinge
Nailing paltem all applications - two nabs per shingle.
NOA No.: 17-0824.05
Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 7 of 9
HATTERAS ACCESSORY
1/4" wide bead of adhesive, T long, mm)—`j
314"1-1" from side edge of cap shingle
(M m —"OWN(25 mm)
(07 mm)
L
Mailing {pattern all applications - two nails per shingle.
PRESIDENTIAL ACCESSORY
1M" wide tread of adheslva, 3"-3112" iong,
314M" from site edge of oap shingle
APPROV��
10
Nulling pattern all appllvatlons - two malls par shingle.
NOA No.: 17-0824.05
Expiration Date: 11/15/22
Approval Date: 11/16/17
Page 8 of 9
1/4" wide bead of adhesive, 4" long,
3/4"-1" from side edge of cap shingle
CEDAR CREST
V (25 mm)
12"
(305 mm)
(219 mm)
12"
1 (305 mm) I
Nailing pattern all applications - two nails per shingle.
END OF THIS ACCEPTANCE
NOA No.: 17-0824.05
r M°aROYED rrrnr Expiration Date: 11/15/22
• �
Approval Date: 11/16/17
Page 9 of 9
M i AM MDAl
,
A=ffi�.
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.gov/economy
CertainTeed Corporation
20 Moores Road
Malvern, PA 19355
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Ridge Vent 12" Filtered and 9" Filtered
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 15-0831.05 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0213.07
M1AMMADE COUN Expiration Date: 06/14/22
flffl Approval Date: 05/11/17
Page 1 of 4
ROOFING COMPONENT APPROVAL
Catesory: Roofing
Sub-Cateeory: Ventilation
Materials: Plastic
Maximum Desizn Pressure: NIA
Fire Classification: NIA
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test
Product
Product
Dimensions
Specification
Description
CertainTeed Ridge Vent
See detail drawing
TAS 100
High density polypropylene Iow profile attic ridge vent
12" Filtered
herein
for installation in shingle roof systems.
CertainTeed Ridge Vent
See detail drawing
TAS 100
High density polypropylene low profile attic ridge vent
9" Filtered
herein
for installation in shingle roof systems
MANUFACTURING LOCATION
1. Orrick, MO
EVIDENCE SUBMITTED:
Test Agency/Identifier
Name
Repo
Date
Architectural Testing, Inc.
TAS 100A(95)
6457.01-109-18
08/08/06
TAS 100A(95)
65453.01-109-18
08/08/06
PRI Construction Materials Technologies
ASTM G 155
AVIG-006-02-01
10/18/11
ASTM G 1929
AVIG-005-02-01
10/18/11
ASTM D 635
AVIG-005-02-01
10/18/11
ASTM D 2843
AVIG-005-02-01
10/18/11
NOA No.: 17-0213.07
MWMFWIDECOUNTY Expiration Date: 06/14/22
' Approval Date: 05/11/17
Page 2 of 4
APPROVED APPLICATIONS:
Tradename: CertainTeed Ridge Vent 12" Filtered, and
CertainTeed Ridge Vent 9" Filtered
System Type: Mechanical attachment of static vent over asphalt shingle roof systems only.
Slot: Cut a minimum 11/2" slot along the apex of the roof by cutting 3/a" on each side of the ridge.
The slot shall terminate approximately 6" from the rake edge.
Installation: Place ridge vent section centered over the void at one end of the ridge. Plugged end should
be flush with end wall of ventilated space under roof. Pre -fasten first section using roofing
nails through pre -drilled nail bosses. Continue to pre -fasten remaining sections, making
sure support walls are flat on roof and filter is secure between shingles and vent. Cut final
section to length.
Ridge Shingle: Nail cap shingles in place using roofing nails long enough to penetrate through the roof
sheathing a minimum of 3/]6 of an inch. Use nail lines provided on vent.
Net Free Area: Refer to manufacturers published literature.
Minimum Slope: 2:12
LIMITATIONS:
1. Refer to applicable Building Codes for required ventilation.
2. This acceptance is for installations over asphalt shingle roof systems only.
3. CertainTeed Ridge Vent 12" Filtered, and CertainTeed Ridge Vent 9" Filtered Ridge Vents shall not be installed
on roof mean heights greater than 33 feet.
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the
Miami -Dade County Product Control Seal as shown below.
NOA No.: 17-0213.07
Expiration Date: 06/14/22
Approval Date: 05/11/17
Page 3 of 4
DETAIL DRAWINGS
CERTAINTEED RIDGE VENT - 12" FILTERED
s.s
3.5
5,2
11.3
CERTAINTEED RIDGE VENT - 911 FILTERED
END OF THIS ACCEPTANCE
NOA No.: 17-0213.07
MIAMMADE COUNTY Expiration Date: 06/14/22
Approval Date: 05/11/17
Page 4 of 4
M1;I.A�i+i1�lO�QI: :
MIAMI-DARE COUNTY
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES R
PRODUCT CONTROL SECTION
BOARD AND CODE ADMINISTRATION DIVISION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
NOTICE OF ACCEPTANCE(NOA)
T (786) 315-2590 F (786) 315-2599
wwwaniangdade.gov/economv
CertainTeed Corporation
20 Moores Road
Malvern, PA 19355
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Underlayment Systems
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA# 17-0306.07 and consists of pages 1 through 9.
The submitted documentation was reviewed by Freddy Sernino is
a
DADECOUN Y NOA No.: 19-0506.02
Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 1 of 9
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS
SCOPE:
This approves CertainTeed Underlayment Systems, as described in this Notice of Acceptance; designed to comply with
the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions Test Product
Specification Description
WinterGuard HT 36" x 65' ASTM D 1970 Modified fiberglass reinforced, bituminous sheet
Manufacturing Location rolls material for use as an underlayment in sloped roof
#I assemblies. Designed as an ice & rain shield.
WinterGuard Granular 36" x 65' ASTM D 1970 Granular surfaced modified, fiberglass reinforced,
Manufacturing Location rolls bituminous sheet material for use as an
#2 underlayment in sloped roof assemblies.
Designed as an ice & rain shield.
WinterGuard Sand 36" x 32.5' ASTM D 1970 Embedded sand surfaced modified, fiberglass
Manufacturing Location rolls reinforced, bituminous sheet material for use as an
#2 underlayment in sloped roof assemblies.
Designed as an ice & rain shield.
Diamond Deck' 48" x 250' ASTM D 226 Synthetic, scrim reinforced underlayment for use
Manufacturing Location rolls Type II under shake, shingles, slate or metal roofing.
#3,4,A6
MetaLayment' 39 3/8" x 61 ASTM D 1970 A film surfaced, self -adhering underlayment for
Manufacturing Location rolls use under metal roofing.
#I
Black Diamonds" 39 3/s" x 68' 7" ASTM D 1970 Granular surfaced modified, fiberglass reinforced,
Base Sheet rolls bituminous sheet material for use as an
Manufacturing Location underlayment in sloped roof assemblies.
#2 Designed as an ice & rain shield. Not for use as
an Anchor Sheet. Direct adhesion to wood deck
not permitted in the HVHZ.
M1AWDADECOl1A1TY NOA No.: 19-0506.02
' Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 2 of 9
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions Test Product
Specification Desc�tion
Flintlastic GTA 39 3/a" x 32' 10" ASTM D 6222 Granule surfaced APP Modified Bitumen
Manufacturing Location rolls Grade G membrane with non -woven polyester mat
#1 Type I reinforcement for torch application.
All Weather/Empire
Base Sheet
Manufacturing Location
##1
Flintlastic GMS
Manufacturing Location
#1
Flintlastic SA Cap
Manufacturing
Location #1
Roofers' Select
Manufacturing
Location #5
RoofRunner
Manufacturing
Location #6
39 3/8" x 65' 10" ASTM D 4601 Asphalt coated fiberglass reinforced base sheet.
rolls Type II
39 3/e" x 32' 10" ASTM D 6164 Granule surfaced SBS Modified Bitumen
rolls Grade G membrane with non -woven polyester mat
Type I reinforcement for mop application.
39 3/e" x 33' 11"
rolls
36" x 144' rolls
48" x 250 rolls
MANUFACTURING LOCATION:
1. Little Rock, AR.
2. Shakopee, MN
3. Hangzhou, China
4. Silvassa, India
5. Shreveport, LA
6. Dadra, India
TAS 103 Polyester reinforced, self -adhering SBS modified
bitumen cap sheet.
ASTM D226 An asphalt -impregnated, organic felt reinforced
Type I with glass fibers, roofing underlayment.
ASTM D226 Synthetic, scrim reinforced underlayment for use
Type II under asphalt shingles.
NOA No.: 19-0506.02
Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 3 of 9
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
TrinitylERD
3530.12.05-1-111
ASTM D1623
10/05/09
C32240.03.10
ASTM D4977
03/04/10
C30890.03.10-1
ASTM D1970
03/17/10
C3500.04.10
TAS 103
04/01/10
C31860.05.10
ASTM D1623
05/18/10
C40050.09.12-2
ASTM D1970
09/28/12
C45240.01.14-1
ASTM D1970, TAS 110
01/15/14
C32930.01.11-R2
ASTM D1623
01/20/14
C45240.01.14-2
TAS 103, TAS 110
01/24/14
SC6465.05.14
ASTM D 226
05/29/14
SC7470.10.14
TAS 114 B
10/21/14
CTR-SC 11 145.09-3A
ASTM D4601
09/19/16
CTR-SC11415.11.16
TAS 103
11/28/16
CTR-SC11505.12.16
ASTM D1623
12/22/16
ACT-SC14110.06.17-1
ASTM D 226
06/29/17
ACT-SC14110.06.17-3
ASTM D 226
06/29/17
PRI Construction Materials
CTC-071-02-01
ASTM D6222
08/08/11
Technologies, LLC
CTC-093-02-01
ASTM D6164, ASTM D4798
08/09/11
CTC-163-02-01
ASTM D6757, ASTM D226,
05/09/13
ASTM D4869
InterTek Testing Services Ltd.
10103165000Q-002C
ASTM D226
08/13/13
101227796COQ-003C
ASTM D4798
08/13/13
10103165000Q-005C
ASTM D4869
08/13/13
QAI Laboratories
RJ3502-1
ASTM E108
09/29/14
Nemo / etc.
4S-CTR-18-003.09.18
ASTM D4798
9/21/18
4S-CTR-18-003.03.09.A
ASTM D226/ TAS 110
03/13/19
NOA No.: 19-0506.02
Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 4 of 9
APPROVED ASSEMBLIES:
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12 or Above) One or more plies of Diamond Deck with a minimum 4" headlap and a 6" end
lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge
and in a and nattern spaced 12" o.c. in the field of the roll.
(2:12 to < 4:12) One or more plies of Diamond Deck with a minimum 25" head lap and a 12"
end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll. Vertical joints should be offset
72" minimum.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, and metal roof applications. Must Comply with applicable Roofing Application Standards
and Building Codes
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12 or Above) A single layer of RoofRunner shall be applied with printed side up, parallel to
the eaves, overlapping each course with a minimum 4" head lap and a 6" end lap mechanically
fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge and spaced 15"o.c.
vertically and 12"o.c. horizontally in the field of the roll.
Surfacing: Shall be acceptable for use in approved asphaltic shingle applications. Must Comply with
applicable Roofing Application Standards and Building Codes
NOA No.: 19-0506.02
Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 5 of 9
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12 or Above) Two plies of Roofers' Select with a minimum 4" head lap and a 6" end lap
mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge and in
a grid pattern spaced 12"o.c. in the field of the roll.
(2:12 to < 4:12) Two plies of Roofers' Select with a minimum 19" head lap and a 12" end lap
mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge and in
a grid pattern spaced 12"o.c. in the field of the roll. Vertical joints should be offset 72"
minimum.
Surfacing: Shall be acceptable for use in approved asphaltic shingle applications. Must Comply with
applicable Roofing Application Standards and Building Codes
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane: One or more plies of Flintlastic GTA torch applied to anchor sheet or WinterGuard HT,
WinterGuard Granular, WinterGuard Sand, MetaLayment or Black Diamond Base Sheet self -
adhering membrane adhered to the anchor sheet with a minimum 3" headlap and 6" end lap.
Place the first course of membrane parallel to the eave, rolling the membrane to obtain
maximum contact. Remove the release membrane as the membrane is applied. Vertical
strapping of the membrane is acceptable. If membrane is strapped, then anchor sheet must also
be strapped.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, and metal roof applications. Must Comply with applicable Roofing Application Standards
and Building Codes
NOA No.: 19-0506.02
Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 6 of 9
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(5): Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One ply of ASTM D 226 Type II organic felt or All Weather/Empire Base mechanically
attached with a minimum 4" side lap and a minimum 6" end lap. Anchor sheet shall be applied
at a right angle (900) to the slope of the deck with approved annular ring shank nails and tin
caps at a fastener spacing of 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in
the field of the roll of the base sheet.
Ply Sheet: (Optional) One or more plies of an ASTM D226 ply sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Membrane: One ply of Flintlastic GMS adhered in a full mopping of Type IV asphalt applied within the
EVT range and at a rate of 2040 lbs./sq. or Flintlastic GTA torch applied to the preceding sheet
or Flintlastic SA Cap, self -adhering membranes adhered to the preceding sheet with a minimum
4" side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied. Vertical strapping of the membrane is acceptable. If membrane is strapped, then
anchor sheet and ply sheet must also be strapped.
When used in Tile roof systems the cap sheet shall be back nailed to deck with approved
annular ring shank nails and tin caps at a maximum of 12" o.c. at the side laps and 6" o.c. at the
end laps. No nails or tin caps shall be exposed.
Surfacing: •Flintlastic. SA Cap, Flintlastic GTA and Flintlastic GMS may be used with any approved roof
tile system mechanically fastened as specified in their current NOA.
*Flintlastic SA Cap, Flintlastic GTA and Flintlastic GMS may be used with any approved roof
tile system adhered as specified in their current NOA using any foam adhesive listed and
having a current tile adhesive NOA approval.
Must comply with appropriate Roofing Application Standard RAS 118, RAS 119, RAS 120 and
applicable Building Codes.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,
state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County
Product Control Seal as shown below.
NOA No.: 19-0506.02
Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 7 of 9
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this material.
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. CertainTeed underlayment roofing systems utilizing Flintlastic GTA, WinterGuard HT, WinterGuard Granular,
WinterGuard Sand, DiamondDeck, MetaLayment or Black Diamond Base Sheet as a cap membrane shall be
acceptable for use in asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications.
CertainTeed underlayment roofing systems utilizing RoofRunner or Roofers' Select shall be acceptable for use in
asphaltic shingles.
3. CertainTeed underlayment roofing systems utilizing Flintlastic SA Cap, Flintlastic GTA or Flintlastic GMS as a
cap membrane shall be acceptable for use in foam adhesive set and mechanically fastened roof file systems as
specified in the surfacing option of the approved assemblies.
4. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. CertainTeed underlayment roofing systems shall be installed in strict compliance with
applicable Building Code.
5. CertainTeed underlayment roofing systems membranes shall be applied to a smooth, clean and dry surface with
deck free of irregularities.
6. CertainTeed underlayment roofing systems membranes shall not be applied over an existing roof membrane as a
recover system but may be applied over an approved roofing Base/Anchor sheet underlayment.
7. WinterGuard HT, WinterGuard Granular, WinterGuard Sand, Black Diamond Base Sheet, Flintlastic SA Cap,
MetaLayment, Diamond Deck, Flintlastic GMS, and Flintlastic GTA shall not be left exposed as a temporary roof
for longer than 180 days of application. RoofRunner and Roofers' Select shall not be left exposed as a temporary
roof for longer than 30 days after application.
8. CertainTeed underlayment products may be used with any approved roof covering Notice of Acceptance listing
CertainTeed underlayment products as a component part of an assembly in the Notice of Acceptance. If
CertainTeed underlayment products are not listed, a request may be made to the Authority Having Jurisdiction
(AHJ) or Miami -Dade County Product Control for approval provided that appropriate documentation is provided
to detail compatibility of the products, wind uplift resistance, and fire testing results.
9. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
10. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions.
11. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
12. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
NOA No.: 19-0506.02
Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 8 of 9
LIMITATIONS:
13. The maximum roof slope for use as roof tile underlayment in direct -to -deck tile assemblies shall be as follows.
Use of loading boards or batten strips is required on roof slopes greater than that reported in the Table below to
prevent slippage.
TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE ASSEMBLIES
Underlayment
Tile Profile
Staging Method
Maximum Slope
Flintlastic GMS
Flat 1 Lugged
Max. 10-tile stack
4:12
Flintlastic GTA
Flat 1 Lugged
Max. 10-tile stack
6:12
Flat
Max. 6-tile stack (4 over
6:12
Flintlastic SA
2)
Lugged
gg
Max. 6-tile stack (4 over
5:12
Cap
2)
END OF THIS ACCEPTANCE
NOA No.: 19-0506.02
Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 9 of 9