Loading...
HomeMy WebLinkAboutBuilding Permit Application4UI APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: var- DL 1. r. Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 PERMIT • • • Ji Permit Number: Building Permit Application Address: 8608 PENNY LN FT PIERCE, FL 34951 Property Tax ID #: 1301-608-0191-000-8 Site Plan Name: MATTHEW KARRAM Project Name: MATTHEW KARRAM REROOF SHINGLE Commercial Residential X Additional work to be performed under this permit —check all that apply: Lot No. 3 Block No. 95 _Mechanical _ Gas Tank —Gas Piping _ Shutters Windows/Doors _ Electric _ Plumbing _ Sprinklers _ Generator V% Roof J , Pitch Total Sq. Ft of Construction: Sq. Ft. of First Floor: 195j-A Cost of Construction: $ 23,500 Utilities: —Sewer —Septic Building Height: 15t V.0!* :. Name t CW a riG-nr` Name: WAYNE T BURNETT Addre �►E N 1J m Company: FHIA LLC City: {t I l rC_t State: Address: 3044 SW 42ND ST Zip Code: �c�1-L`S� Fax: City: HOLLYWOOD State: FL Phone No. 8 [d MT-1 Zip Code: 33311 Fax: E-Mail: Phone No 954-792-4415 FIII in fee simple Title Holder on next page (if different E-Mail from the Owner listed above) State or County License CCC1331144 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If valve of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. =St RR EN ENTAL'C AISTRUCTIQN ""C N'LAW If FdR ATM - DESIGN ERENGINEER: _ NotApplicableMORTGAGE COMPANY: Not Applicable Name: Name: Address: Address: City: State: City: State- Zip: Phone Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use "111►ARMNG TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROYEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAW FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT_0 Signature of Owner/ Lesse /Contractor as Agent far Owner ntractor/License Holder SiWUO STATE OF FLORIDA SORID COUNTY OF CJ(3,j The forgoing instrument was acknowledged before me this T day of eA 2t& by The forgoing instrum nt was acknowledged before me this � day ArG�+ 20 i A441 . of by 'QL)U� Name of person making statement. Name of person Vnaking statement. Personally Known c-"" OR Produced Identification Personally Known 11 OR Produced Identification Type of Identification 49YPt MANUELHERNANDEZ Type of Identificat9l Produced �'' ommission# GG 004918 Produc Expires June 22, 2020 BandedThruBudgetNotery$erv1i;N apy�0 ���ryPul]hCStets?Of pf4 sFbride Jusn Andrea Zurita My Commission {;a S4iia2 (Signature of Notary P lic- State of Florida j at of Public- o i a Commission No. (Seal) Commis I n No. {Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED ev. 277719 rage 1 01 Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: 86os PENNY IN Se+c/ TDwn/Range: 02/34SJ39E Map ID: 13/02N Zoning: RS-4 Count Ownership Matthew J Karram 8608 Penny LN Fort Pierce, FL 34951 Legal Description LAKEWOOD PARK -UNIT 8- BLK 95 LOT3 (MAP 13102N) (OR 3987-77) Current Values Just/Market Va.1ue: $102,400 Assessed Value: $81,566 Exemptions: $50,000 Taxable Value: $31,566 Property taxes are subject to change upon change of ownership. • Past taxes are not a reliable projection of future taxes. The sale of it property will prompt the removal of all exemptions, assessment caps, and special classifications. Taxes for this parcel: SLC Tax Collectofs Office Download TRIM for this parcel: Download PDF Parcel ID: 1301-608-0191-000-8 Account #: 2167 Use Type: 0100 Jurisdiction: Saint Lucie County Total Areas FinishedtU'nder Air (SF): 1,440 Gross Sketched Area (SF): 2.096 Land Size (acres): 0.22 Land Sizo (SF): 9,750 All information is believed to be correct at this time, but is subject to change and is provided without any warranty. 0 Copyright 2020 Saint Lucie County Property Appraiser. All rights reserved. htq)s://www.pasle.org/RECard/ 2/27/2020 Florida Home ImprovemerltAssaCiate, Orlando Tek 407-472-83811 License NO- CGC 0614118014244818 OW I ry Fm 954-792-2170 8034St11npartDr.#401 • Oriand%FL32eog ' + Webslte:-WWW.FKAPRDDLICT5•COM FI oRIDA l:malb INFO®FHAPRODUl7MX0M HOME Job ' f tMPROV MENT IV ASSOCIATES Replacement Rooting Contract [dame2111-Home Phone: E'iiit ' fidS'&m Address. ati State Zip This Cantrad Isrnade and entenedinto thisIc 20� by and between Florida Home draprovemerrMAssodata Ma a Flarlda Corporation r Contrsctor•ar'FHA'l and owner (s)named above of the residence located at the address listed above ('Owner•!. Thl-W011P Contractor agrees to perform described below 1) Remove existing roofco mring and at aessorles 2) Prepare roof as necessary to Melva installation of new roofing materials 3) Roof Type: Shingles Tile Roof Metal Roof Flat Roof 4) Remove: Shingles--9�,Sq. Tile Roof-----Sq. Metal Roof Sq. Fiat Roof-----5q. 5) Remove: Gutters L17 Lineal Feet Remove and re -hang 6) Install: Shingles_ I Sq. TlieRaaf 5q. Metal Puaf Sq. FlatRoof-------3q. 7) Install: Gutters Lineal Feet B) Install:ShingieType: 9) InMIL Color -` r/ 10) Install, VentType: Ridge Roll Box Vent 11) Install: Underlavment Farr K.-Z. n-6 I War-ChKk all that apply to this contract" — Lifetime shingle coverage from manufacturer �j �Tear-off 50years from manufacturer Nan -prorated coverage 5p years from manufacturer ` plsposal 50 years from manufacturer �I Materials and labor 50years from manufacturer _ Workmanship 25 years from manufacturer AddwRml arartc ftricNat to be dons: _ schedule :Contractar!FWcommencethe work within 7 daysaftertheexecution ofthecontract( the'Comrnenaementpateland shall endeavor to complete all work hereunder within days aft the Commencement Date. TheTWAL IWCE for all Labor and Materials I including mw appicable, dbcount) US Z*341 •O Down Payment Ia S Balance payable Is S Contractor wIll provide to Owner a Finalwa[verand Release ofUen andi ontractoes Reel A7rdavtt to Owner. subsWrtlapyshnllar to the forms Included In chapter713. FkuidaStatues�2M docleone n(YES ortla)oarelects toapply forfinancingoftheabovestated lump sumamountIfyesisdnded.see fiancingagreement and related Nntice to the Owner, lfftand ng Fs betng obtained by Owner - a) Do not sign d4zRome lmprovemantContract iincluding BnmcingdocumrnlslinbhmL b) Y"ansaMidedtoacopy oftheeonemce■ttWUmeyuusigs.iieepnteprotect ymulegairlghts. c) 7MA"andaldocumentsattachedtothiFHornelmprovemerltCantradmaycontainamortageorotherwisecmftnlienonyourprop"het could befor4osed on if you do act pay. Be sure yea understand all provision of fhetentmStmad Gnondaidocuments beftuayou signs. amen waiver tact contains the entimcontract ofthepartlas.ltMAY not berh"edorally but onybyasigned change orderorothexWd ten bi' nypartypfabreachofanyprovhfonofthlscontract"IlActoperateorbetonstmedmawaivvDfanysatuequentJam by any party. All transadlpnsare subject torevlewand apprMW by theInstallatlonandCreditdepartmentswhomaymncetandreiunubseqd any down payment. IN-VM 4F.thepattleshenetohave exenrtedthis cnniraMuoclarse4asofthe day andyearfirsta cancel nIthis contract eH'mpdwhave wdtten.you the buyerrnry for a»y e>tpiar»nlon Df this riphL famrdnlglstonOn rfierthedateoFthlstransaWonseeattachednottoeofcan,,d Uonform � Dwnrr/�� . contractor. -r 15 /'� AAAGrr Q. 7C �111�1L,14�� $v: �o6r.: r`—,r•a.�t �kv sw.. oY. er ram - �Gda Home Owners Assadatfon Name: Phortelf: Z yES lY J NO( 1 [atrtmunity Name f � Q1� Scanned with CamScanner ''crida Home Improvement Associates Orlaadalbl.407-472-VAI 11034 S No' CCC 13110461/ R844818 Fm 954-742-2170 4 SynPo" Dr. 0401 . Orlando,FL 328og Webslte: WWWFHAPRDDUM.CDM as Emaik iNFO@FHAPRODUCTS.COM FLOPIPA j HOHE �O j t C� ' ASSOIMPRC ATES T / { !! <, Replacement Roofing Worksheet Name: f j-kZC/ `'��l49kAJ Home Phone. AM'SU-)Cell- Address T1111iffork, Check all that apply to this contract: City % State Zip . Remove eAsting roof covering ( NOTE: removed Items are likely to he damaged and cannot be reused? Replace rotted ar damaged roof decking as applicable to this project Repair or replace existing fascia board as applicable to this project Re nail existing mdf deck to meet current Florida Building codes --_ Install new 15I6 felt underlayment as appbcableto this project (certain warranties may not apply) Install new 3011; fait underlayment as applicable to this project Install CertainTeed Diamond Deck superhigh performance underlayment as applicable to this project Apply AWcemerrt and membrane atoll roof penetrations (certain warranties maynotapply) Install CertaInTeed MnterGuard high performance underlayment at all roof penetrations Install CertainTeed standard three tab starter shingles as applicable to this project (certain warranties may not apply) Install CertalnTeed Swift Start high performance startershingle3 as applicable to this project _ Install standard drlpedge around perimeter of roof as applicable to this project (certain warranties may not apply) Install heavy gaugehigh performance drip edge around perimeterof roof as appihable to this project Install standard valley metal In valleys as applicable to this project (certain merranties may not apply) Install CertainTeed WrnterGuard high performance underlayment In valleys asapplicableto this project Install new roofventilat(on to replace existing Icertain warranties may not apply) Install new certainTeed high perfonnan oe ridge Yentas applicableta this project Install new standard three tab CartainTsed shingler Color: rift— (certain warranties may not apply) —Install new CertaInTeed Landmark Pro shingles: Color. ,M.�Ds 6119d _ Install new standard Hip and Ridge Accessories as applicable to this project (certain warranties may not apply) Install new[ertain%ed Hip and R1dgeAccessorles as applicable to this project Cleanup and haul away all materials and debris from roof work f Check all that apply to this contract: Lifetime shingle coverage from manufacturer Tear -off 50 years from manufacturer Non -prorated coverage 50 years from manufacturer Disposal 50 years from manufacturer Materials and labor 50 years from manufacturer Workmanship 25 years from manufacturer Total List Price: $ 2' r Customer Name; Date• Customer Name. Date; Scanned with CamScanner Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Maser Permit No. Process No. Conbsctor's Name FH IA LLC Job Address 8608 PENNY LN, FORT PIERCE FL 34951 ROOF CATEGORY 0 Low Slope 0 Mechanically Fastened Tile 13 MortodAdheshre Set Tile 0 Asphaltic 0 Metal PoneliShingles 0 Wood Shingwahakes Shingles 154 PrescripAre there tive 13UR�RAS Gas Vent Stacks? Yes ❑ Nod( ROOF TYPE Type: Natural ❑ LPGXU C] New Roof Re -Roofing D Recovering 0 Repair El Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Seep Sloped Roof Area (SF) Total (SF) 0 1454 1454 SeRIgn I [Road P� Ian) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. include dimensions of sections and levels, clearly IdentlW dimensions of elevated oressu a zones and location of oaraoets. SHINGLES SHINGLES 14 N/A e N + s w Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Sectl�on_D Meeo SIODed Roof fSSys_�eml SIGOR Slo ed Roof S stem Description Deck Type:6. 5/8 PLYWOOD Roof Slope: 3 •12 Ridge Ventllation? yes Mean Roof Height: 150 I DIAMOND DECK W/20" HEADLAP ASTM D 226 TYPE II I N/A N/A Type $ Spacing: -1 4 RS COIL NAIL 6 " OC LAP 1121, OC FIELD fesive Type N/A yPe Cap Sheet: N/A OOf Covering: CERTAINTEED LANDMARK PRO SHINGLES Type & Size Drip ge. 3" GALV 26 Ga 3/20/2019 CERTAINTEED CORP, TFWZ.R684 - UL Product Spec UL PRODUCT CATEGORY SHINGLES Prepared Roof -covering Materials See General Information for Prepared Roof -covering Materials CERTAINTEED CORP R684 ROOFING PRODUCTS GROUP 20 MOORES RD MALVERN, PA 19355 USA Asphalt glass mat shingles designated "Highland Slate", "Highland Slate IR", "Presidential Solaris" "Presidential Shake", "XT 25", "XT 25 Metric", "XT 30", "XT 30 Metric", "Hatteras", "Carriage House", "Grand Manor", "Landmark", "Genesis", "Esten", "Landmark Pro", "Architect 80", "Landmark Solaris", "Landmark Solaris Gold/Platinum", "Landmark Premium", "Landmark TI_", "XT 30 IR", and Patriot for installation as Class A prepared roof coverings. Suitable for installation on minimum 3/8 in. thick plywood decks. Also Classified in accordance with ASTM D3161, Class F. Also Classified in accordance with ASTM D3462. Also Classified in accordance with CSA-A123.5. Asphalt glass mat shingles designated "CT 20", "CT 20 Metric", "Landmark IR", "Landmark Solaris", "Landmark TI_ Solaris", "Landmark Solaris IR", "Landmark Pro Solarls", "Arcadia Solaris" and "Swiftstart" for installation as Class A prepared roof coverings. Suitable for installation on minimum 3/8 in. thick plywood decks. Also Classified in accordance with ASTM D3161, Class F. Also Classified in accordance with ASTM D3462. Asphalt glass mat shingles designated, "Belmont", "Belmont IR", "Arcadia" for installation as Class A prepared roof coverings. Suitable for installation on minimum 3/8 in. thick plywood decks. Also Classified in accordance with ASTM D3161, Class F. Also Classified in accordance with ASTM D3462. Also Classified in accordance with CSA-A123.5. Asphalt glass mat shingles designated, "Presidential Shake IR", "Presidential Shake TL", "Presidential Shake TL Solaris" for installation as Class A prepared roof coverings. Suitable for installation on minimum 3/8 in. thick plywood decks. Also Classified in accordance with ASTM D3161, Class F or Class A. Also Classified in accordance with ASTM D3462. Also Classified in accordance with CSA-Al23.5. Asphalt glass mat shingles designated "Independence" for installation as Class A prepared roof coverings. Suitable for installation on minimum 3/8 in. thick plywood decks. Also Classified in accordance with ASTM D3161, Class A or Class D. Also Classified in accordance with ASTM D3462. Also Classified in accordance with CSA-A123.5. Asphalt glass mat shingles designated "Firehalt" or "Firescreen" for installation as Class A prepared roof coverings. Suitable for installation on minimum 3/8 in. thick plywood decks. Also Classified in accordance with ASTM D3161, Class A. http:llproductapec.ul.com/document.php?id=TFWZ.R684 113 3/20/2019 CERTAIMTEED CORP, TFWZ.R684 - Ui_ Product Spec Asphalt glass mat shingles designated "Presidential Starter", "Presidential Starter IR" and "High Performance Starter" for installation as Class A prepared roof coverings. Suitable for installation on minimum 318 in. thick plywood decks. Also Classified in accordance with ASTM D3462. Also Classified in accordance with ASTM D3161, Class F. Also Classified in accordance with CSA-A123.5. Asphalt glass mat shingles designated "Universal Starter" for installation as Class A prepared roof coverings. Suitable for installation on minimum 3/8 in. thick plywood decks. Also Classified in accordance with ASTM D3462. Also Classified in accordance with ASTM D3161, Class F. Asphalt glass mat shingles designated "CT 20", "XT25", "XT30", "Hatteras", "Highland Slate", "Carriage House", "Grand Manor", "Shadow Ridge", "Ridge", "Shangle Ridge", "Landmark", "Genesis", "Esten", "Landmark Pro", "Architect 80", "Landmark Premium", "Presidential Shake", "Presidential Shake IR", "Presidential Shake TL", "Landmark TL", "Firehalt", "XT 30 IR", "Independence", "Patriot", "Landmark IR", "Landmark Solaris", "Landmark Solaris", "Firescreen", "Mountain. Ridge", "Cedar Crest IR", "Presidential IR", "Presidential Solaris", "Landmark Solaris", "Landmark IR", "Highland Slate IR" and "NorthGate" for installation as Class A prepared roof covering when used with minimum Type 30 underiayment over existing wood shingle roof. Asphalt glass mat hip and ridge shingles designated "Mountain Ridge" for installation as Class A prepared roof coverings and as wind resistant roof coverings. Wind resistance has also been evaluated in accordance with ASTM D3161, Class F. Also Classified in accordance with ASTM. D3462. Also Classified in accordance with CSA-A123.5. Asphalt glass mat hip and ridge shingles designated "Solaris H&R Accessory", "Solaris Accessory", "Solaris Accessory IR", "Shangle Ridge", "Shadow Ridge", "Ridge" and "Cedar Crest" for installation as Class A prepared roof coverings and have also been evaluated in accordance with ASTM D3161, Class F when BASF Sonnolastic NP 1 adhesive or Henkel PL® Polyurethane Roof & Flashing Sealant, applied as specified in manufacturer's application instructions." Also Classified in accordance with ASTM D3462. Also Classified in accordance with CSA-A123.5. Modified asphalt glass fiber mat shingles designated "NorthGate" for installation as Class A roof covering. Suitable for installation on minimum 3/8 in. thick plywood in combination with minimum one ply "Shingle -Mate" or Type 15 or Type 30 underlayment. Also Classified in accordance with ASTM D3161, Class F. Also Classified in accordance with ASTM D3462. Also Classified in accordance with CSA123.5. Modified asphalt glass fiber mat hip and ridge shingles designated "NorthGate Ridge" and "NorthGate Accessory" Metric for installation as Class A roof covering. Also Classified in accordance with ASTM. D3161, Class F. Also Classified in accordance with ASTM D3462. Also Classified in accordance with CSA123.5. Asphalt coated glass fiber shingle, designated "Shadow Ridge". Last Updated on 2019-01-23 The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. http:llproductspec.ul.00m/document.php?id=TFWZ.R684 213 3/20/2019 CERTAINTEED CORP, TFWZ.R684 - UL Product Spec UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "OO 2019 UL LLC". UL and the UL logo are trademarks of UL LLC C 2019 All Rights Reserved. http:llproductspec.ul.com/document.php?id=TFWZ.R684 313 Ml® MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eav�economy CertainTeed Corporation 20 Moores Road Malvern, PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Landmark, Landmark Pro, Landmark Pro/Archetect 80, Landmark Premium, Landmark Impact Resistant, Landmark Solaris, Landmark Pro Solaris and Landmark Solaris Gold/Platinum LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 17-1211.08 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino 8 —� NOA No.: 18-1114.02 MIAMHUMECOUNTY Expiration Date: 02/28/22 . • ,4mApproval Date: 05/09/19 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Cates Roofing Sub -Category: Asphalt Shingles Materials Dimensional Deck Type: Wood SCOPE This acceptance is for CertainTeed Landmark, Landmark Pro, Landmark Pro/Architect 80, Landmark Premium, Landmark Impact Resistant, Landmark Solaris, Landmark Pro Solaris and Landmark Solaris Gold/Platinum Shingles as manufactured by CertainTeed Corporation described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION: Test Prndnrt Certainteed Landmark Manufacturing Locations #1, 2, 3, 4, 5, 6, 7, 8, 9, 13 %4" x 38 %" TAS 110 A heavy weight, dimensional 10 asphalt shingle. Certainteed Landmark Pro A heavy weight, dimensional Manufacturing Locations #1, 3, 4, 5, 6, 9, 10 13'/4" x 38 3/a" TAS 110 asphalt shingle. Certainteed Landmark Premium A heavy weight, dimensional Manufacturing Locations #1, 3, 4, 5, 6, 8, 9 13'/4" x 38 3/4" TAS 110 asphalt shingle. Certainteed Landmark Impact Resistant I A heavy weight, dimensional Manufacturing Locations #7 13 %4" x 38 3/4" TAS 110 asphalt shingle. Certainteed Landmark Pro/Architect 80 A heavy weight, dimensional Manufacturing Locations #8 13'/4" x 38 3/4" TAS 110 asphalt shingle. Certainteed Landmark Solaris A heavy weight, dimensional Manufacturing Locations #8, 9 13'/a" x 38 3/4" TAS 110 asphalt shingle. CertainTeed Landmark Pro Solaris Manufacturing Location #9 131/4" x 38 3/4" TAS 110 A heavy weight, dimensional asphalt shingle Certainteed Landmark Solaris Gold/Platinum A heavy weight, dimensional Manufacturing Locations # 8 13'/4" x 38 3/a" TAS 110 asphalt shingle. Accessory Shingles Accessory shingles for hip, ridge various proprietary and starter strip applications. XK. T i•iHl\ ur HL 1 unuN ky 11VC.A 11L11V b: 1. Peachtree City, GA 2. Ennis, TX 3. Oxford, NC 4. Shakopee, MN NOA No.: 18-1114.02 MIAMMMDE COON W Expiration Date: 02/28/22 `"' • ' Approval Date: 05/09/19 Page 2 of 7 5. Avery (Milan), OH 6. Norwood, MA 7. Shreveport, LA 8. Portland, OR 9. Wilmington, CA 10. Jonesburg, MO EVIDENCE SUBMITTED: Test Agency, Test Identifier Test Name/Report Date PRI Asphalt Technologies, Inc. PCTC-01-02-01 TAS 100 01/12/01 CTC-006-02-01 TAS 100 11/12/02 CTC-092-02-01 TAS 100 02/23/12 CTC-091-02-01 TAS 100 02/21/12 CTC-090-02-01 TAS 100 09/02/11 CTC-087-02-01 TAS 100 07/07/11 CTC-086-02-01 TAS 100 07/07/11 CTC-101-02-01 TAS 100 10/05/11 CTC-102-02-01 TAS 100 10/05/11 CTC-109-02-01 TAS 100 01/18/12 CTC-106-02-01 TAS 100 11/02/11 CTC-105-02-01 TAS 100 10/31/11 CTC-089-02-01 TAS 100 07/18/11 CTC-088-02-01 TAS 100 07/18/11 CTC-213-02-01 TAS 100 05/20/14 CTC-212-02-01 TAS 100 05/21/14 CTC-207-02-01 TAS 100 05/20/14 CTC-206-02-01 TAS 100 05/20/14 CTC-110-02-01 TAS 100 02/13/12 CTC-109-02-01 TAS 100 02/13/12 CTC-288-02-01 TAS 100 09/27/ 16 CTC-333-02-01 TAS 100 11/08/17 Underwriters Laboratories, Inc. 94NK9632 Wind uplift resistance TAS 107 11/30/00 R684 UL 790 04/02/01 02NK42448 Wind uplift resistance TAS 107 11/08/02 09CA28973 Letter 07/23/09 l ICA59020 TAS 107/ ASTM D3161 01/25/12 1 INK07864 TAS 107/ ASTM D3161 09/29/11 07CA26696 TAS 107/ ASTM D3161 09/21/07 I ICA38844 TAS 107/ ASTM D3161 01/28/12 11 CA38844 TAS 107/ ASTM D3161 01/27/12 06CA28237 TAS 107/ ASTM D3161 09/22/06 IONK17366 TAS 107/ ASTM D3161 01/04/1 l 4786334383 TAS 107/ ASTM D3161 05/28/14 4786307351 TAS 107/ ASTM D3161/ASTM D 3462 05/13/14 NOA No.: 18-1114.02 MIAM14OMECOUNTY Expiration Date: 02/28/22 ` "' • ' Approval Date: 05/09/19 Page 3 of 7 I INK08333 ASTM D3462 05/15/12 11NK08333 ASTM D3462 04/15/12 I INK07864 ASTM D3462 09/29/11 11NK08333/Letter ASTM D3462 / UL790 11/05/12 11NK08333/Letter ASTM D3462 / UL790 11/05/12 11NK08333/Letter ASTM D3462 / UL790 11/05/12 12NK13474 ASTM D3462 / UL790 05/27/13 4786325932 ASTM D3462 / UL790 04/04/14 4787011023 ASTM D 3462 08/01/15 1 ICA38844 TAS 107/ ASTM D3161 01/26/12 06CA02648 TAS 107/ ASTM D3161 02/23/06 4787084802 TAS 107/ ASTM D3161 03/14/16 4787852839 ASTM D3462 03/24/17 4787011023 ASTM D3462 08/01/15 4788368979 ASTM D3462 10/30/18 4787592174 ASTM D3462 10/21/16 LIMITATIONS: I. Fire classification is not part of this acceptance; refer to ,i current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION: 1. Shingles shall be installed in compliance with Roofing Application Standard RAS It 5. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail W, attached. 5. Nailing shall be in compliance with Detail W, attached. NOA No.: 18-1114.02 MAMIHOXWE COUNTY Expiration Date: 02128/22 ` ' ' ' • ' Approval Date: 05/09/19 Page 4 of 7 LABELING: 1. Shingles shall be labeled with the Miami -Dade Product Control approved seal as seen below or the wording "Miami -Dade County Product Control Approved". BUILDING PERMIT REQUIREMENTS: 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 18-1114.02 Expiration Date: 02/28/22 Approval Date: 05/09/19 Page 5 of 7 SHINGLE LAYOUT Eaves LANDMARK, LANDMARK PRO, LANDMARK PRO/ARCHITECT $O, LANDMARK PREMIUM, LANDMARK IMPACT RESISTANT, LANDMARK SOLARIS, LANDMARK PRO SOLARIS AND LANDMARK SOLARIS GOLD/PLATINUM NOA No.: 18-1114.02 Expiration Date: 02/28/22 Approval Date: 05/09/19 Page 6 of 7 DETAIL B i _ 38 3/4" VV10E � NAILING AREA N a i ling area far "low L stand a rd slopes (from 2:12 to 21:12' Nail hatween upper& lower nail lines. 1" 12" 14 3/4" 12" dle— 5 fir. Exposure LANDMARK, LANDMARK PRO, LANDMARK PRO/ARCHETECT 80,LANDMARK PREMIUM, LANDMARK IMPACT RESISTANT, LANDMARK SOLARIS, LANDMARK PRO SOLARIS AND LANDMARK SOLARIS GOLD/PLATINUM (LOW AND STANDARD SLOPE) Mailing area for "steep" slopes (greater than 21:12) Nail between bottom 2 nail lines. 12"14 3/4" 5 5/8" Exposure LANDMARK, LANDMARK PRO, LANDMARK PRO/ARCHETECT 80, LANDMARK PREMIUM, LANDMARK IMPACT RESISTANT, LANDMARK SOLARIS, LANDMARK PRO SOLARIS AND LANDMARK SOLARIS GOLD/PLATINUM (STEEP SLOPE) END OF THIS ACCEPTANCE NOA No.: 18-1114.02 WMIAMMADECOUNTYM Expiration Date: 02/28/22 • •. . Approval Date: 05/09/19 Page 7 of 7 NIANt 14IIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 209 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175 2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www-mismldade.aov/monomv CertainTeed Corporation -' 1400 Union Meeting Road Blue Bell, PA 19422 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their j urisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Shangle Ridge, Shadow Ridge, Hatteras Accessory, Presidential Accessory, and Cedar Crest Hip and Ridge Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miarni-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA# 12-061 l .02 and consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0824.05 Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 1 of 9 ROOFING ASSEMBLY .APPROVAL Cateaory• Roofing Sub -Cate o : Asphalt Shingles Materials Laminated Deck Tyne: Wood SCOPE This approves CertainTeed Shangle Ridge, Shadow Ridge, Hatteras Accessory, Presidential Accessory and Cedar Crest Hip and Ridge Shingles as manufactured by CertainTeed Corporation (PA) and described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications Shangle Ridge 12" x 18" TAS 110 A pre -assembled, double layer hip and Manufacturing Location(s) # 1 ridge fiberglass reinforced asphalt shingle with an 8" exposure. Shadow Ridge 12" x 12" Manufacturing Location(s) # 1, 2, 3,4 Hatteras Accessory 12" x 18" Manufacturing Location(s) # I Presidential Accessory 12" x 1217 Manufacturing Location(s) # .2 Cedar Crest 12" x 12" Manufacturing Location(s) # I TAS 110 A pre -assembled hip and ridge fiberglass reinforced asphalt shingle with an 5" exposure. TAS 110 A pre -assembled hip and ridge fiberglass reinforced asphalt shingle with an 8" exposure. TAS 110 A pre -assembled hip and ridge fiberglass reinforced asphalt shingle with an 5" exposure. TAS 110 PRODUCTS MANUFACTURED BY OTHERS Product Product Description Any approved sealant with a current Miami Sealant Dade NOA A pre -assembled hip and ridge fiberglass reinforced asphalt shingle with an 8" exposure. Size Manufacturer various Any approved manufacturer (with a current Miami Dade NOA) Any approved adhesive with a current ASTM C920, Type S, various Any approved manufacturer Miami Dade NOA Grade NS, min Class 25 (with a current Miami Dade NOA) NOA No.: 17-0824.05 Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 2 of 9 MANUFACTURING LOCATION 1. Oxford, NC. 2. Shakopee, MN. 3. Avery, OH 4. Norwood, MA. EVIDENCE SUBMITTED Test Agen ,v Test Identifier Test Name/Reno Date PRI Asphalt Technologies, Inc. CTC-028-02-01 ASTM D 6381 08/06/07 CTC-021-02-01 TAS 100(A) 05/16/06 CTC-029-02-01 TAS 100(A) 08/06/07 CTC-030-02-01 TAS 100(A) 08/06/07 CTC-020-02-01 TAS 100(A) 05/16/06 CTC-072-02-01 TAS 100(A) 02/10/11 CTC-334-02-01 TAS 107 08/29/17 CTC-330-02-01 TAS 107 08/27/17 CTC-310-02-01 TAS 100(A) 0581117 CTC-311-02-01 TAS 100(A) 05/31/17 CTC-312-02-0I TAS 100(A) 05/31/17 CTC-315-02-01 TAS 100(A) 06/19/17 CTC-314-02-01 TAS 100(A) 06/19/17 Underwriters Laboratories, Inc. 07CA30825 ASTM D 3161 08/06/07 R684 ASTM D 3462 08/04/04 R684 ASTM D 3462 08/05/04 IOCA44960 ASTM D 3462 11/11/10 IOCA44960 ASTM D 3161 11/11/10 4787855169 ASTM D 3161/3462 07/27/17 4787855164 ASTM D 3161/3462 06/27/17 4787867612 ASTM D 3161/3462 07/26/17 4787855162 ASTM D 3161/3462 06/26/17 4787955167 ASTM D 3161/3462 06/30/17 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION 1. Ridge Cap Shingles shalt be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Layout Details herein NOA No.: 17-0824.05 Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 3 of 9 LABELING 1. Ridge Cap Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County Product Control Approved"- MIAMi-Dwu2 COUNTY I,...I BUILDING PERmn REQUIREMENTS Application for building permit shall be accompanied by copies of the foIIowing: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. 1� Fklm the left side FIRST .LAYOUT DETAILS SHANGLE RIDGE LEFT Exposures Rem* tape from the rigt side and tstan SECOND RIGHT NOA No.: 17-0824.05 Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 4 of 9 SHADOW RIDGE HATTERAS ACCESSORY NOA No.: 17-0824.05 Mu1MIlD Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 5 of 9 PRESIDENTIAL ACCESSORY CEDAR CREST Sealant 4" Starter NOA No.: 17-0824.05 MIAMI-SWD; COUNTY Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 6 of 9 1/4" wide bead of adhosive, 7" long, 314"Am from side edge of sap shingle NAILING DETAILS SHANGLE RIDGE 12• 1` 6 rr of (219 7' (26 MM) (457 mm) Nailing pattern all applications - two naps per shingle. SHADOW RIDGE 1A" vw 1de bead of adhes lye, 3'-3 1!2' long, 3l411-11" from side edge of cap $hinge Nailing paltem all applications - two nabs per shingle. NOA No.: 17-0824.05 Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 7 of 9 HATTERAS ACCESSORY 1/4" wide bead of adhesive, T long, mm)—`j 314"1-1" from side edge of cap shingle (M m —"OWN(25 mm) (07 mm) L Mailing {pattern all applications - two nails per shingle. PRESIDENTIAL ACCESSORY 1M" wide tread of adheslva, 3"-3112" iong, 314M" from site edge of oap shingle APPROV�� 10 Nulling pattern all appllvatlons - two malls par shingle. NOA No.: 17-0824.05 Expiration Date: 11/15/22 Approval Date: 11/16/17 Page 8 of 9 1/4" wide bead of adhesive, 4" long, 3/4"-1" from side edge of cap shingle CEDAR CREST V (25 mm) 12" (305 mm) (219 mm) 12" 1 (305 mm) I Nailing pattern all applications - two nails per shingle. END OF THIS ACCEPTANCE NOA No.: 17-0824.05 r M°aROYED rrrnr Expiration Date: 11/15/22 • � Approval Date: 11/16/17 Page 9 of 9 M i AM MDAl , A=ffi�. MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy CertainTeed Corporation 20 Moores Road Malvern, PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Ridge Vent 12" Filtered and 9" Filtered LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 15-0831.05 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0213.07 M1AMMADE COUN Expiration Date: 06/14/22 flffl Approval Date: 05/11/17 Page 1 of 4 ROOFING COMPONENT APPROVAL Catesory: Roofing Sub-Cateeory: Ventilation Materials: Plastic Maximum Desizn Pressure: NIA Fire Classification: NIA TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description CertainTeed Ridge Vent See detail drawing TAS 100 High density polypropylene Iow profile attic ridge vent 12" Filtered herein for installation in shingle roof systems. CertainTeed Ridge Vent See detail drawing TAS 100 High density polypropylene low profile attic ridge vent 9" Filtered herein for installation in shingle roof systems MANUFACTURING LOCATION 1. Orrick, MO EVIDENCE SUBMITTED: Test Agency/Identifier Name Repo Date Architectural Testing, Inc. TAS 100A(95) 6457.01-109-18 08/08/06 TAS 100A(95) 65453.01-109-18 08/08/06 PRI Construction Materials Technologies ASTM G 155 AVIG-006-02-01 10/18/11 ASTM G 1929 AVIG-005-02-01 10/18/11 ASTM D 635 AVIG-005-02-01 10/18/11 ASTM D 2843 AVIG-005-02-01 10/18/11 NOA No.: 17-0213.07 MWMFWIDECOUNTY Expiration Date: 06/14/22 ' Approval Date: 05/11/17 Page 2 of 4 APPROVED APPLICATIONS: Tradename: CertainTeed Ridge Vent 12" Filtered, and CertainTeed Ridge Vent 9" Filtered System Type: Mechanical attachment of static vent over asphalt shingle roof systems only. Slot: Cut a minimum 11/2" slot along the apex of the roof by cutting 3/a" on each side of the ridge. The slot shall terminate approximately 6" from the rake edge. Installation: Place ridge vent section centered over the void at one end of the ridge. Plugged end should be flush with end wall of ventilated space under roof. Pre -fasten first section using roofing nails through pre -drilled nail bosses. Continue to pre -fasten remaining sections, making sure support walls are flat on roof and filter is secure between shingles and vent. Cut final section to length. Ridge Shingle: Nail cap shingles in place using roofing nails long enough to penetrate through the roof sheathing a minimum of 3/]6 of an inch. Use nail lines provided on vent. Net Free Area: Refer to manufacturers published literature. Minimum Slope: 2:12 LIMITATIONS: 1. Refer to applicable Building Codes for required ventilation. 2. This acceptance is for installations over asphalt shingle roof systems only. 3. CertainTeed Ridge Vent 12" Filtered, and CertainTeed Ridge Vent 9" Filtered Ridge Vents shall not be installed on roof mean heights greater than 33 feet. 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. NOA No.: 17-0213.07 Expiration Date: 06/14/22 Approval Date: 05/11/17 Page 3 of 4 DETAIL DRAWINGS CERTAINTEED RIDGE VENT - 12" FILTERED s.s 3.5 5,2 11.3 CERTAINTEED RIDGE VENT - 911 FILTERED END OF THIS ACCEPTANCE NOA No.: 17-0213.07 MIAMMADE COUNTY Expiration Date: 06/14/22 Approval Date: 05/11/17 Page 4 of 4 M1;I.A�i+i1�lO�QI: : MIAMI-DARE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES R PRODUCT CONTROL SECTION BOARD AND CODE ADMINISTRATION DIVISION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 NOTICE OF ACCEPTANCE(NOA) T (786) 315-2590 F (786) 315-2599 wwwaniangdade.gov/economv CertainTeed Corporation 20 Moores Road Malvern, PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Underlayment Systems LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA# 17-0306.07 and consists of pages 1 through 9. The submitted documentation was reviewed by Freddy Sernino is a DADECOUN Y NOA No.: 19-0506.02 Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 1 of 9 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS SCOPE: This approves CertainTeed Underlayment Systems, as described in this Notice of Acceptance; designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Product Specification Description WinterGuard HT 36" x 65' ASTM D 1970 Modified fiberglass reinforced, bituminous sheet Manufacturing Location rolls material for use as an underlayment in sloped roof #I assemblies. Designed as an ice & rain shield. WinterGuard Granular 36" x 65' ASTM D 1970 Granular surfaced modified, fiberglass reinforced, Manufacturing Location rolls bituminous sheet material for use as an #2 underlayment in sloped roof assemblies. Designed as an ice & rain shield. WinterGuard Sand 36" x 32.5' ASTM D 1970 Embedded sand surfaced modified, fiberglass Manufacturing Location rolls reinforced, bituminous sheet material for use as an #2 underlayment in sloped roof assemblies. Designed as an ice & rain shield. Diamond Deck' 48" x 250' ASTM D 226 Synthetic, scrim reinforced underlayment for use Manufacturing Location rolls Type II under shake, shingles, slate or metal roofing. #3,4,A6 MetaLayment' 39 3/8" x 61 ASTM D 1970 A film surfaced, self -adhering underlayment for Manufacturing Location rolls use under metal roofing. #I Black Diamonds" 39 3/s" x 68' 7" ASTM D 1970 Granular surfaced modified, fiberglass reinforced, Base Sheet rolls bituminous sheet material for use as an Manufacturing Location underlayment in sloped roof assemblies. #2 Designed as an ice & rain shield. Not for use as an Anchor Sheet. Direct adhesion to wood deck not permitted in the HVHZ. M1AWDADECOl1A1TY NOA No.: 19-0506.02 ' Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 2 of 9 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Product Specification Desc�tion Flintlastic GTA 39 3/a" x 32' 10" ASTM D 6222 Granule surfaced APP Modified Bitumen Manufacturing Location rolls Grade G membrane with non -woven polyester mat #1 Type I reinforcement for torch application. All Weather/Empire Base Sheet Manufacturing Location ##1 Flintlastic GMS Manufacturing Location #1 Flintlastic SA Cap Manufacturing Location #1 Roofers' Select Manufacturing Location #5 RoofRunner Manufacturing Location #6 39 3/8" x 65' 10" ASTM D 4601 Asphalt coated fiberglass reinforced base sheet. rolls Type II 39 3/e" x 32' 10" ASTM D 6164 Granule surfaced SBS Modified Bitumen rolls Grade G membrane with non -woven polyester mat Type I reinforcement for mop application. 39 3/e" x 33' 11" rolls 36" x 144' rolls 48" x 250 rolls MANUFACTURING LOCATION: 1. Little Rock, AR. 2. Shakopee, MN 3. Hangzhou, China 4. Silvassa, India 5. Shreveport, LA 6. Dadra, India TAS 103 Polyester reinforced, self -adhering SBS modified bitumen cap sheet. ASTM D226 An asphalt -impregnated, organic felt reinforced Type I with glass fibers, roofing underlayment. ASTM D226 Synthetic, scrim reinforced underlayment for use Type II under asphalt shingles. NOA No.: 19-0506.02 Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 3 of 9 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date TrinitylERD 3530.12.05-1-111 ASTM D1623 10/05/09 C32240.03.10 ASTM D4977 03/04/10 C30890.03.10-1 ASTM D1970 03/17/10 C3500.04.10 TAS 103 04/01/10 C31860.05.10 ASTM D1623 05/18/10 C40050.09.12-2 ASTM D1970 09/28/12 C45240.01.14-1 ASTM D1970, TAS 110 01/15/14 C32930.01.11-R2 ASTM D1623 01/20/14 C45240.01.14-2 TAS 103, TAS 110 01/24/14 SC6465.05.14 ASTM D 226 05/29/14 SC7470.10.14 TAS 114 B 10/21/14 CTR-SC 11 145.09-3A ASTM D4601 09/19/16 CTR-SC11415.11.16 TAS 103 11/28/16 CTR-SC11505.12.16 ASTM D1623 12/22/16 ACT-SC14110.06.17-1 ASTM D 226 06/29/17 ACT-SC14110.06.17-3 ASTM D 226 06/29/17 PRI Construction Materials CTC-071-02-01 ASTM D6222 08/08/11 Technologies, LLC CTC-093-02-01 ASTM D6164, ASTM D4798 08/09/11 CTC-163-02-01 ASTM D6757, ASTM D226, 05/09/13 ASTM D4869 InterTek Testing Services Ltd. 10103165000Q-002C ASTM D226 08/13/13 101227796COQ-003C ASTM D4798 08/13/13 10103165000Q-005C ASTM D4869 08/13/13 QAI Laboratories RJ3502-1 ASTM E108 09/29/14 Nemo / etc. 4S-CTR-18-003.09.18 ASTM D4798 9/21/18 4S-CTR-18-003.03.09.A ASTM D226/ TAS 110 03/13/19 NOA No.: 19-0506.02 Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 4 of 9 APPROVED ASSEMBLIES: Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened to deck. Anchor Sheet: (4:12 or Above) One or more plies of Diamond Deck with a minimum 4" headlap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a and nattern spaced 12" o.c. in the field of the roll. (2:12 to < 4:12) One or more plies of Diamond Deck with a minimum 25" head lap and a 12" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Vertical joints should be offset 72" minimum. Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications. Must Comply with applicable Roofing Application Standards and Building Codes Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(2): Anchor sheet mechanically fastened to deck. Anchor Sheet: (4:12 or Above) A single layer of RoofRunner shall be applied with printed side up, parallel to the eaves, overlapping each course with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge and spaced 15"o.c. vertically and 12"o.c. horizontally in the field of the roll. Surfacing: Shall be acceptable for use in approved asphaltic shingle applications. Must Comply with applicable Roofing Application Standards and Building Codes NOA No.: 19-0506.02 Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 5 of 9 Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(3): Anchor sheet mechanically fastened to deck. Anchor Sheet: (4:12 or Above) Two plies of Roofers' Select with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge and in a grid pattern spaced 12"o.c. in the field of the roll. (2:12 to < 4:12) Two plies of Roofers' Select with a minimum 19" head lap and a 12" end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge and in a grid pattern spaced 12"o.c. in the field of the roll. Vertical joints should be offset 72" minimum. Surfacing: Shall be acceptable for use in approved asphaltic shingle applications. Must Comply with applicable Roofing Application Standards and Building Codes Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(4): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Membrane: One or more plies of Flintlastic GTA torch applied to anchor sheet or WinterGuard HT, WinterGuard Granular, WinterGuard Sand, MetaLayment or Black Diamond Base Sheet self - adhering membrane adhered to the anchor sheet with a minimum 3" headlap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the membrane is acceptable. If membrane is strapped, then anchor sheet must also be strapped. Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications. Must Comply with applicable Roofing Application Standards and Building Codes NOA No.: 19-0506.02 Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 6 of 9 Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(5): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One ply of ASTM D 226 Type II organic felt or All Weather/Empire Base mechanically attached with a minimum 4" side lap and a minimum 6" end lap. Anchor sheet shall be applied at a right angle (900) to the slope of the deck with approved annular ring shank nails and tin caps at a fastener spacing of 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll of the base sheet. Ply Sheet: (Optional) One or more plies of an ASTM D226 ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One ply of Flintlastic GMS adhered in a full mopping of Type IV asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or Flintlastic GTA torch applied to the preceding sheet or Flintlastic SA Cap, self -adhering membranes adhered to the preceding sheet with a minimum 4" side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the membrane is acceptable. If membrane is strapped, then anchor sheet and ply sheet must also be strapped. When used in Tile roof systems the cap sheet shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum of 12" o.c. at the side laps and 6" o.c. at the end laps. No nails or tin caps shall be exposed. Surfacing: •Flintlastic. SA Cap, Flintlastic GTA and Flintlastic GMS may be used with any approved roof tile system mechanically fastened as specified in their current NOA. *Flintlastic SA Cap, Flintlastic GTA and Flintlastic GMS may be used with any approved roof tile system adhered as specified in their current NOA using any foam adhesive listed and having a current tile adhesive NOA approval. Must comply with appropriate Roofing Application Standard RAS 118, RAS 119, RAS 120 and applicable Building Codes. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. NOA No.: 19-0506.02 Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 7 of 9 BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. CertainTeed underlayment roofing systems utilizing Flintlastic GTA, WinterGuard HT, WinterGuard Granular, WinterGuard Sand, DiamondDeck, MetaLayment or Black Diamond Base Sheet as a cap membrane shall be acceptable for use in asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications. CertainTeed underlayment roofing systems utilizing RoofRunner or Roofers' Select shall be acceptable for use in asphaltic shingles. 3. CertainTeed underlayment roofing systems utilizing Flintlastic SA Cap, Flintlastic GTA or Flintlastic GMS as a cap membrane shall be acceptable for use in foam adhesive set and mechanically fastened roof file systems as specified in the surfacing option of the approved assemblies. 4. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. CertainTeed underlayment roofing systems shall be installed in strict compliance with applicable Building Code. 5. CertainTeed underlayment roofing systems membranes shall be applied to a smooth, clean and dry surface with deck free of irregularities. 6. CertainTeed underlayment roofing systems membranes shall not be applied over an existing roof membrane as a recover system but may be applied over an approved roofing Base/Anchor sheet underlayment. 7. WinterGuard HT, WinterGuard Granular, WinterGuard Sand, Black Diamond Base Sheet, Flintlastic SA Cap, MetaLayment, Diamond Deck, Flintlastic GMS, and Flintlastic GTA shall not be left exposed as a temporary roof for longer than 180 days of application. RoofRunner and Roofers' Select shall not be left exposed as a temporary roof for longer than 30 days after application. 8. CertainTeed underlayment products may be used with any approved roof covering Notice of Acceptance listing CertainTeed underlayment products as a component part of an assembly in the Notice of Acceptance. If CertainTeed underlayment products are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or Miami -Dade County Product Control for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 9. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 10. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 11. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 12. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. NOA No.: 19-0506.02 Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 8 of 9 LIMITATIONS: 13. The maximum roof slope for use as roof tile underlayment in direct -to -deck tile assemblies shall be as follows. Use of loading boards or batten strips is required on roof slopes greater than that reported in the Table below to prevent slippage. TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE ASSEMBLIES Underlayment Tile Profile Staging Method Maximum Slope Flintlastic GMS Flat 1 Lugged Max. 10-tile stack 4:12 Flintlastic GTA Flat 1 Lugged Max. 10-tile stack 6:12 Flat Max. 6-tile stack (4 over 6:12 Flintlastic SA 2) Lugged gg Max. 6-tile stack (4 over 5:12 Cap 2) END OF THIS ACCEPTANCE NOA No.: 19-0506.02 Expiration Date: 11/24/24 Approval Date: 07/25/19 Page 9 of 9