FL# FL20484-111
it
Application-Type Revision
Code Version 2017
Application Status Approved
, s
I
Comments
Archived �1
Product Manufacturer UNION CORRUGATING.COMPANY
Address/Phone/Email. 701 S.-KING`ST.
FAYETTEVILLE,NC 28301
(910)483-0479 Ext 256
jstieby@un ioncorrugating.com
Authorized Signature John Stieby
jstieby@unioncorrugating.com REVIEWED F®R
Technical Representative CODE COMPLIANCE
Address/Phone%Emaii ST. L��.D p g p(.'9"IE
Quality.Assuranee Representative OC6COUNTY
Address/Phone/Email
Category Roofing
Subcategory' Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalipgam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 09/07/2027•
Validated By Yoosef Lavi,,P.E.
ii Validation Checklist-Hardcopy Received
Certificate of Independence FL20484 R1 COI Certificateindeoendence.odP
Referenced Standard.and Year(of Standard) Standard Year
FM 4470 2012
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Can,
i
I
haps:7/www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgX... 10/12/2019
ionaa tsun(ung Looe umme
Product Approval Method Method 1 Option D
Date Submitte6 08/23/2017
Date Validated 68/28/2017
Date Pending FPC Approval 09/01/2017
Date Approved 12/12/2017
1
_S mmai bf roducts i
FL# Mode, umber or Name Description
0484.1 5V Min 26 ga.,24"wide through fastened panel over 15/32"
khicR.plywood i
Limits of Use' installation Instructions
Approved for'use in HVHZ:No 1`00484 RI II Eva luationReportC2175 1 pdf
Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam,P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-169 Evaluation Reports j
Other:Uplift load of 71.0 psf @ fastener spacing of 24"o.c. FL20484 R2 AE EvaluatlonReportC2175 1 pdf
&169.0 psf @ fastener spacing'of 6"o.c. Created by Independent Third Party:Yes
20484.2 Advantage-Lok II Min 26 ga.,16"wide concealed fastened panel over 7/16" t
thick OSB&15/32"&thick plywood
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL20484 R1 II EvaluationReportC2175 2 ndf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
.Design Pressure:+N/A/-116 Evaluation Reports
Other:Maximumuplift load of 116.0.psf @ seam fastener EL20484 RI AE EvaluationReportC2175 2.Ddf
spacing of 4-5/8"o.c.along seam into min.15/32"thick APA Created by Independent Third Party:Yes
rated plywood with retainer strap.
20484.3 Aluminum Advantage-Lok II Max 16.375 wide,nom 0.032"thick(min.)aluminum
concealed fastener roof panel over min 15/32"thick plywood
deck'or 7/16"thick OSB.
Limits of Use` Installation Instructions
Approved for use in HVHZ:No FL20484 RI 1I Eva luationReportC2175 3)df
Approved,for use outside HVHZ:Yes Verified By:Bala Sockalingam P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-93.5. Evaluation Reports
Other:Uplift load,of 22.5 psf at fastener spacing of 18:5" FL20484 R1 AE EvaluationReportC2175 3 pdf
ox.and 86.0 psf at fastener spacing of 4.63"o.c.in 15/32" Created by Independent Third Party:Yes
plywood-or 7/16"OSB.Uplift load of.93.5 psf at fastener
spacing of.4.63"o:c.with structural sealant in 15/32"
plywood..
20484.4 Aluminum SLi50 Max 16"wide,nam 0.032"thick(min.)aluminum.snap-lack
standing seam metal panel over min'15/32"thick plywood
deck Pr 7/16"thick OSB.
Limits of Use Installation Instructions
Approved for use in HVHZ:No, FL20484 R1 II Evahlatio"RegortC2175 4 pdf
Approved foruse outside HVHZ:Yes Verified By:Bala Sockalingam P.E.62240
Impact Resistant:N/A Created by.Independent Third Party:Yes
Design Pressure:+N/A/-86 Evaluation Reports
Other:Uplift load,of 45.0 psf at clip spacing of 24"o.c.and FL20484 R1 AE EvaluationReoortC2175 4 pdf
78.5 psf at clip spacing of 6"o:c.in 15/32"plywood,or 7/16" Created by Independent Third Party:Yes
OSB:.Uplift load of 86.0-psf at clip spacing of 6"o.c.with
structural sealant in 15%32"plywood.
20484.5 MasterRib Min 29 ga.,36"wide through fastened panel over 15/32"
thick.plywood or 7/16"thick OSB
Limits of Use Installation Instructions
Approveid.for use-in HVHZ:No FL20484 RI 11 EvaluationReportC2175 5 odf
Approved for use outside.HVHZ:Yes Verified By: Bala Sockalingam,P.E.62240
Impact Resistant:N/p. Created by Independent Third Pally:Yes
Design Pressure:+N/A/-124 Evaluation Reports
Other:Uplift load of 56.0 psf,@ fastener spacing of 24"o.c: FL20484 R7 AE EvaluationRenortC2175 5 Ddf
&124.0 psf,@ fastener spacing of,6"o.c. Created by Independent Third Party:Yes
20484.6 . MasterRibMin 29 ga.,36"wide through fastened panel over 15/32"
' thick plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20484 R1 11 EYaluatlonReportC2175 6 pdF
Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam,P.E.62240
Impact Resistant:N/A :Created by Independent Third Party:Yes
Design Pressure:+N/A/-88.5 Evaluation Reports
Other:Uplift to-ad.of 56 psf for Fastening System 1.Uplift k20484 RI AE EvaluationReportC2175 6 Ddf
load of 88.5 psf for Fastening System 2. Created by Independent Third Party:Yes
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param-wGEVXQwtDgsJ9a49YAgX..: 10/12/2019
"Florida Building Code Online -Page 3 of 3
20484.7 ML150
Max 16.5'wide,min 24 ga.steel standing seam panel over
15/,32"thick plywood
Limits of Use Installation Instructions
Approved for use In HVHZ:No F00484 111 IT Evaluation ReportC2175 7.pd
Approved for use outside HVHZ:Yes Verified By:Bala ScCkallngam,P.E.62240
Impact Resistant:N/A. Created by Independent Third Party:Yes
Dealg in Pressure:+N/A/-124 Evaluation Reports
'
Other:Maximum uplift load of 124 psf @ clip spacing of 6" FL20484PI AE EvaluatiorilleportC2175 7.pd
o.c.with 180 seam,self-adhering membrane and fixed clip. d by
I ndependent Third Party:Yes
20464.8 PBP or R Panel Min 26 ga.,36'wide through fastened panel over 1:5/32"
thick plywood
Limits of Use In.stallation Instructions
Approved for use in HVHZ:No FL20484 RI 11 Eva luationRevortC2 175 8.pdf
Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-161.5 Evaluation-Reports
Other:Uplift load of 30.0 psf at fastener spacing of 48"o.c. FL20484 111 AE Eva luationReportC2175 8.6d
and 161.5 psf at fastener-spacing of 6"o.c. Created by Independent Third Party:Yes
20484.9
Max 18"wide,min 24 ga.,snap-lock standing seam metal
panel over 15/32"thick plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20484 RI 11 FvaluationRpnortC2175 9.pd
Approved for use outside HVHZ*Yes Verified By:Bala Sockallngam,P.E.62240
Impact Resistant:N/A , Created by Independent Third Party:Yes
Design Pressure.;+WA/-93.5 Evaluation:Reports
Other:Uplift load of 39.8 psf @,clip spacing of 36"o.c.and FL20484-Rl AE. Evaluation RebortC2 175 9.odf
78.6 psf @ Clip spacing of 8"o.c with felt.Uplift load of 93.5 Created by Independent Third Party;Yes
psf @ clip spacing of 12"o.c.with self-adhering membrane.
FS.- rN..
Contact Q ::2601 Blair Stone Road.Tallahassee FL 32399 Phone:$50-487-1824
The State of Florida Is an AA/EEO employer.Cogyright 2007-2013 State of Florida,::PdXacy Statement::Accessibility Statement Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity,instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees Licensed under Chapter 455;F.S.must provide the Department with an email address if they have one.The
emalls Provided may be used for official communication with the licensee.However email addresses are public record.If you do not Wish to supply a personal address,
please provide the Department with an ornall address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click her
Product Approval Accepts:
DIEM F=99 RE M
Credit Card
Safe
https://www.floridabu'ilding.org/pripx_appdfl.asm?ParamwGEVXQWtDqsJ9a49YAQX... 10/12/2019
_ =
V i
EVALUATION REPORT OF
UNION CORRUGA'T'ING COMPANY
'26 GA.5V PANEL'
r
i
FLORIDA BUILDING CODE 6TH EDITION (2017)-
FLORIDA PRODUCT APPROVAL.,
FLS 20484.1-R1 i
ROOFING
METAL ROOFING '
s
Prepared For:
Union Corrugating Company
701 S.Ding St.
:Fayetteville,NC 28301
Telephoxie: (910)483-0479
Fax: (910)483-1091
Prepared By:
Bala Socltalingam,Ph.D.', P.E.
Florida Professional Engineer#62240
1216 N Lansing Ave., Suite C
Tulsa, OK 747106
Telephone: (918)492-9992
FAX: (866).366-71543
This report consists'of
Evaluation Report(3 Pages including cover)
Installations Details (1 Page)� am�e,�da ,�
Load Span Table(1 Page) ��,�''G :NU N G q4 f ef
°'�� °�yja S°E°
LU
Report No. 02175-1 r^• ,� ���r't 4
Date: 8.23.2017 , '•. �` p�q° ,:
� Eb:u3
I
I
t
I
FL 20484.1-RI
C2175-1
8.23.2017
Page 2 of 3
Manufacturer; Union Corrugating Company
Product Name: 5V Panel
Panel Description: 24"wide coverage with(5) 1/2"high ribs
Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel{ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A75.5).
Deck Description: Min. 15/32" thick APA rated plywood
lvwood or min. W -thick wood-plank
(min SO- of 0.42) for new and existing constructions. Designed by
others and installed as per FBC 2017.
New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1.
Required for new construction.
Existing Underlayment: One layer of Asphalt shingles over one layer of#3.0 felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 20.17 Section 1507.4.2
Design Uplift Pressure: 71.0 psf @ fastener spacing of 24" o.c.
(Factor of Safety=2) 169.0 psf @ fastener spacing of 6" o.c.
Panel Attachment: #10-15 x 2" long wood screw with washer
At interior @ max 12" o.c. across panel width through panel rib
At panel ends @ max 6" o.c. across panel width through panel flat.and rib
Test Standards: Roof assembly tested in accordance with UL5 80-06 'Uplift Resistance
of Roof Assemblies' & UL1897-04 'Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL comply with test procedures
prescribed in UL 1997-12.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined*for each project in accordance
with FBC. 2017 Section. 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacingmay be
computed using rational analysis prepared by a Florida Professional
Engineer or based on Union load span table. This evaluation report is
FL 20484.1-R1
C2M-1
8-23.2017
Page 3 of 3
not applicable in-High Velocity Hurricane Zone.Refer to current NOA
for use of this product. in High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2017 Section 1505 and current approved roofing materials
directory or ASTM EI08/UL70 report from an accredited laboratory
for firexatings of this product.
Supporting Documents: UL580 &UL1897 Test Reports
Farabaugh Engineering and Testing Inc.
Project No. T197-16,Reporting.Date 5/12/16
ai
PANEL OVERLAP
NEW UNDERLAYMENT. PANEL FASTENER
SEE DETAIL 2 SEE DETAIL 'I SPACING PER ALLOWABLE R
ROOF PANEL r f— r UPLIFT LOAD TABLE
4 WE
_ _ a EXISTING UNDERLAYMENT EXISTING SHINGLES a DECK ATTACHMENT AND PLYWOOD
(OPT1ONAl)- (OPTIONAL)
SUPPORTS MUST BE 15/32" THICK (MIN:) e
DESIGNED AND INSTALLED
BY OTHERS
o
MIN. 2X_ WOOD RAFTER/JOIST/
TRUSS AT"MAX. 24" D.C.
TYPICAL PANEL INSTALLATION X—SECTION u
Z KN rn
x{10-15 X 2" LONG WOOD F Y~iry N
SCREW WITH WASHER oz 1
y o
MIN 26 GA. PANEL u pi o
NEW UNDERLAYMENT � o��
z� W
EXISTING SHINGLES
(OPTIONAL)
EXISTING UNDERLAYMENTWOOD A
(OPTIONAL) 15/32' THICK (MIN.)
i
DETAIL 1 a
GENERAL NOTES: z jw
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
��10-15 X 2" LONG WOOD FLORIDA BUILDING CODE(FBC). �,
SCREW WITH WASHER 2. ROOF PANELS SHALL BE MINIMUM 26 CA. EFFECTIVE COVERING WIDTH OF s
PANEL = 24". a
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS o
NEW UNDERLAYMENT MIN 26 GA. PANEL SPECIflED ON THIS DRAWING.. u
4. REQUIRED DESIGN WIND LOADS SHALL BE'DETERMINED FOR EACH PROJECT.
THIS PANEL SYSTEM MAY,NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE'ALLOWABLE WIND LOAD TABLE. .
5. ALL FASTENERS MUST BE IN.ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
EXISTING SHINGLES REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
(OPTIONAL) 6. RAFTERS/JOISTS/TRUSSES' MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
EXISTING_UNDERLAYMENT
(OPTIONAL) DETAIL 2 PLYWOOD5/32"THICK (MIN.)
02175—t EY,
SHEET H0.
1 of 1
I
v � i
I
S
UNION CORRUGATING COWWANY
5V Panel Uplift Loads
(Ifin 26-ga.)
Description. Fastener Spacing Allowable Uplift
along.Panel Length- Load
fix} (psf)
Coverage width: 24" _M..,_ 6 _ — 169.0
8 - 158.1
Panel.Fasteners 10 1472
#10-15 hex lead screws with 121 6.-3
� —
sealed washer 1-4 121.7
16 106.5
Panel fasteners spaced at 12" 1 g 94.7-
o.c. across panel width.
2085.2
through:ribs. 22 77.5
24 71.0
?Votes:
I. The b6 Id numb crs.indicate design loads calculated from test data with safety factor of 2.
2. Panels_inust be installed as per Evaluation Report FL 20484.1 and Union current installation procedure.
i
{
e.�EA$)O�Qdtlp�D�o '
+s0UU�9�� ,LfiTd ,;UgU Y �J
cb
tea. '`Cr
m
co: y� Lu..,
a til
1216 N Lansing Ave:,Suite C - ;`' ! Bala Sockalingam,Ph.D.,F.E.
Tulsa,Olr 74106 FL 62244
918:492 5992 1 ct