Loading...
HomeMy WebLinkAboutProduct approval I i BCIS Home Log In User Registration Hot Topics i Submit Surcharge.i Stats&Facts I Publications S FBC Staff' Bcls Site Map Links Search - Product Approval dl �, USER:'Public User P-oduct AQQLaj2LMMU>Product or AD ficatiioo Search>application Us t>Application Detail FL# FL17443-R1 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer J A TAYLOR ROOFING Address/Phone/Email 302 Melton.Drive FT PIERCE,FL 34482 (772)466-4040 kylewhite228@aol.com I Authorized Signature Kyle Taylor kylewhite228@aol.com Technical Representative Address/Phone/Email i Quality Assurance Representative j Address/Phone/Email i Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida.Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect.Name who developed the Locke Bowden Evaluation Report Florida License PE-44704 Quality Assurance Entity PRI Construction Materials Technologies,LLC Quality Assurance Contract Expiration Date 01/23/2023 Validated By Zachary R.Priest,P.E. 9 Validation Checklist- Hardcopy Received Certificate of Independence FL17443 R1 COI FL 17443 J A Taylor 2017 Code Eval Report with Details RSSS.pd Referenced Standard and Year(of Standard) Standard Year TAS 125 2003 UL1897 2012 UL580 2006 Equivalence of Product Standards 2�3—b0ZB� Certified By ; REVIEWED FOR Sections from the Code COE COMPLIANCE To LUCIE COUNT � � ' BOCC< , i I Product Approval Method Method 1 Option D Date Submitted 01/24/2018 Date Validated 02/14/2018 Date Pending FBC Approval 02/17/2018 Date Approved 04/10/2018 Summary of Products FL# Model,Number or NameDescription ! i 17443.1 5 V Crimp 26GA 1/2"rib height over 15/32 APA plywood 1 Limits of use Installation Instructions Approved for use in HVHZ:No ( FLI.7443 RI II FL 17443 1 A Taylor 2017 Code Eval Relagrt Approved for use outside HVHZ:,Yes with Details RSSS.pd Impact Resistant:N/A Verified By: Locke Bowden,P.E.49704 - Design Pressure: +N/A/-129,25 Created by Independent Third Party:Yes Other:-129.25 @ 6"o.c.-69.25 @16"o.c. margin of safety Evaluation Reports 2,1 with 24"max,coverage Install per manufacturers detail. FL17443 RI AE FL 7443 7 A Tay!Qr-201.7 Code EvalRe[?-QA Not for use in HVHZ. with Details RSSS.pif Created by Independent Third Party:Yes .............. 17443.2 JVICTORIAN CRIMP SHINGLE 26GA 1/2"RIB-PANELS LOCK INTO PREVIOUS PANELS,VOVER CDX/APA 15/32"PLYWOOD ------------------- Limits of Use Installation Instructions Approved for use in HVHZ:No FL17443 R1 II FL 17443 1 A Taylor 2017 Code Eva[Rept Approved for use outside HVHZ:Yes with.Details RSS4 pdd i impact Resistant:N/A Verified By: Locke Bowden,P.E.49104 Design Pressure: +N/A/-105 Created by Independent Third Party:Yes Other:-105PSF margin of safety 2:1. Install per ?Evaluation Reports, manufacturer's details and in compliance with FBC 2017 6th FL17443 R1 AE FL 17443 A Taylor 201;Code Eval'Repr�k ed, Not for use in HVHZ. with Details RSSS.pdf Created by Independent Third Party:Yes y i - Dark ':Vax1 ' I Contact Us::2601 Blair Stone Raad,Tallahassee Ft.37399 Phone:850-487-1824 The State of Florida is an AA/EEO employer,Qp_y b_t 2007.2013 State of Florida. Pryvdcy Statement;:Accessibiilty Statement;:Refund Statement, Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not sera electronic mail to this entity.Instead,contact the offlce by phone or by traditional mail.if you have any questions,please contact 850,487,1395.'Pursuant to Section 455.275(1),Florida Statutes,'effective.October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one,The emails provided may used for official communication with the licensee.However email addressesare public record,if you do not wish to supply a personal address,please provide the Department with anemail address which can be made available to the public.To determine If you are a licensee under Chapter 455,F,S., please dick Lore_. Product Approval Accepts; :¢: ® r! i Credit Card Safe I , i i I 4 r I I i8 ' "► 9 6 9 0 9` 302 Milton Drive I Fort Pierce,Fl.34.962 (772)466-4040 � a ° ® ► t ► e a 3 i q* g-' ► ► . s ► Compliant with Florida Building Code 2017(61h ed.) Compliant with Florida Product Approval Rule#61G20-3 Compliant Quality Assurance Program:PRI CONSTRUCTION MATERIALS TECHNOLOGY FBC Sections:1504:3.2,1507 s• MMEE= ► ... SV Crimp thru fastened W'rib at each panel edge and 1 fastener in the center of the panel,24"net coverage,'26GA ASTM A792;G-50,AZ55,.018,SOW min.over min.15/32"thick COX plywood deck. Corrosion Resistant fastener#9-15 HWH with) sealing washers,metal to wood connections with fastener length to penetrate 5/16"thru substrate. Fasten along the crown of the rib in the center of panel and along the lap.First fastener to be within 3"of panel edges. Min.8Dxr annular ring sh ink nails spaced W O.C.reroofing,with less than 19/32"plywood (min.1S/32"),this.attachment is to be used in addition to existing attachment. Deck slope 2:12 or greater and shall be com liant with FBC-2017 0 ed.Underlayment:See FBC 201716TH ed.,Sec.1507 Table 1507.1.1 "*Design Pressure: . Spacing: -69.25 PSF 16.O.C. 129.25 PSF 6"O.C. I 02112Mi 26GA ASTM A792,G-50,AZ55,.018,SOW Victorian Crimp Shingle over 15/32"COX/APA Plywood attached to roof trusses. Corrosion Resistant Fastener#10 x V Zincplated,MTW Pancake Head,installed at 2 per panel into lock seam. Panels applied with 12"exposure,adjacent shingles Inserted.into lock seam of previous shingle.Deck slope 2:12 or greater and shall be compliant with FBC 2017 61 ed,Underlayment:See FBC 2017 61"ed.,Sec..1507 Table 1507.1.1 Design Pressure: ** -105 PSF "*DESIGN PRESSURE INCLUDES A SAFETY MARGIN OF 2:1 Reference Data: TEST REPORTS Hurricane Test Laboratory(TST 1527) #0224-0501-06 TAS 125{UL SSG,-941) PRI Construction Materials Technologies(TST 5878) #FAE-023-02-01 UL 580-0611JL 1897-041 1.UL 580-94 test standards are equivalent to UL 580-06 test standards. - 2. UL 1897-04 test standards ore equivalent to UL 1897-12 test standards. Limitations: 1. Underlayment to be compliance with current Florida Building Code(FBC)20i7 6T"ed..see Chart 1507.1.1 2. Minimum slope to be compliant with Florida Building Code 2017 611 ed.,and per with Manufacturer's installation reference. 3. Products are compliant with State of.Floncla product approval per Rule 61620-3. Compliance Method: 1-D 4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is all by other registered .engineers. S. Fire classification is not part,of this acceptance. Shear diaphragm values are.outside this report. 6. Support framing in compliance w/FBC 2017 61 ed.,Chapter 22 Steel,Chapter 23 Wood and.Chapterl6 Structural Loading. 7.. This report does not imply warranty,installation,recommended product use outside of this report. Certificate of Independence: Locke Bowden,P.E.does not have,not will acquire a financial interest in any company manufacturin uting products under this evaluation. � aO W� lop Locke Bowden,P.E.is not owned,operated,or controlled by any company,manufacturer,or •+ tvA-1 tjc�t$iu er this report. ��¢ `" • • '. sdal I M1000% `' I i I 5 V Crimp Fastener-#9-15 corrosion resistant w/sealing washers i i i 24"coverage i 42 Fastener:#9 x;15 corrosion resistant with sealing washers I in Compliance with 2017 Florida Building Code,.Section 1507 Perimeter fastening: 6"o.c... Main Field fastening 1 2"o.c. Panel Width:26" Panel Coverage: 24"maximum 26.GA Architectural Metal Roof panel t MINIMUM 2 FASTENERS Fastener.#10 x 1" ,- AT LOCI{SEAM Zinc Plated MTW z� Pancake Head FIELD CUT 112 SHINGLE TO CREATE STAGGERED PATTERN � VICTORIANS CRIMP, " '; SHINGLES s f'F 4 I i VICTORIAN CRIMP SHINGLE..... I D LOCK SEAM O X r i j r 9"EXPOSURE r: 3. biro, SCIS Home log In i User Registration 3 Hot Topics Submit Surcharge ! Stats&Facts i Publications j FBC Staff 80S Site Map Links ? Search Honda product Approval USER:Public User ro Product Approval Menu>Pmduct or Application.§earth>.Aoolication List>Application Detail r *' FL# FL9777-R11 Application Type Revision Code Versiom 2017 Application on Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659• (740)404-7829 greg.keeler@owenscoming.com I Authorized Signature Greg Keeler greg.keeler@owenscoming.com Technical Representative Address/Phone/Email I Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R.Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden a` Validation Checklist-Hardcopy Received Certificate of Independence FL9777 R1I COI OCRd4002.8a 2017 FBC Evaluation Report Weatherlo k Non-HVHZ.D-df Referenced Standard brid Year(of Standard) Standard Year ASTM D 1970 2015 ASTM D 226 2009 ASTM G 155 2005 TAS 103 �, 1995 UL 1897 I�EY C® PLIANCE IEWE FOR 2012 Equivalence of Product Standards CODE Certified By j ST® LUCIE C®IJNTI( Sections from the Code cc, e COW I ! s � Product Approval Method Method 1 Option D Date Submitted 10/1.1/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 9777.1 Weathercock G Weatherproofing Underiayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R11 II OCR14002 8a 2017 FBC Evaluation Report Approved for use outside HVHZ:Yes Weathercock Non-HVHZ.pdf Impact Resistant:N/A Verified By:Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE 0CR14002 8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ pdf Created by Independent Third Party:Yes 9777.2 WeatherLock G(High Tear) Weatherproofing Underlayment Limits of.Use Installation Instructions Approved for use in HVHZ:No FL9777 R11 II OCR14002 8a 2017 FBC Evaluatiop$gp-(? Approved for use outside HVHZ:Yes Weatherlock-Non-HVHZ.pdf Impact Resistant:N/A Verified By: Zachary.R.Priest PE-74021 Design Pressure:N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation)Report Weatherlock Non-HVHZ pdf Created by Independent Third Party:Yes 9777.3 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9777 RIJ II OCR14002 8b 2017 FBC Evaluation Report Approved for use outside HVHZ:No Weatherlock HVHZ:pdf Impact Resistant:N/A . Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCR14002 8b 2017 FBC Evaluation Report Weatherlock HVHZ.p1d I Created by Independent Third Party: Yes 9777.4 Weatherlock MAT Waterproofing Underlayment Limits of Use installation Instructions _ Approved for use in HVHZ:No FL9777 R11 II OCR14002 8a 2017 FBC Evaluation IRenort Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.odf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes. Other:Seeevaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Renort Weatherlock Non-HVHZ.r)df Created by Independent Third Party:Yes 9777.5 WeatherLock Metal Weatherproofing Underlayment Limits of Use Installation Instructions -Approved for use in HVHZ:No FL9777 R11 II 0CR14002 8a 2017 FBC Evaluation Report Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.odf Impact Resistant:N/A Verified By: Zachary R.Priest PE-74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See;evaluation report for limits of use. Evaluation Reports FL9777 1111 AE OCR14002 8a 2017 FB E4a1uation Weatherlock Non-HVHZ.idf _ Created by Independent Third Party:Yes 19777.6 WeatherLock Metal Weatherproofing Underlayment _-- ✓ — FL9777 R11 II OCRI4002 8b 2017 FBC Evaluation Limits of Use Installation Instructions Approved for use in HVHZ.Yes Report Approved for use outside HVHZ:No Weatherlock HVHZ.Ddf impact Resistant: N/A Verified By:Zachary R.Priest PE-74021 Design Pressure N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL9771 RiI AE OCR14002.8b 2017 F-(-Evaluation Report Weatherlock HVHZ,pdf Created by Independent Third Party: Yes 9777.7 _ Weathercock Specialty Tile&Metal Weatherproofing Underiayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R11 :II OCR14002.8a 2017 FBC Evaluation Report Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.odf Impact Resistant: N/A Verified By: Zachary R.Priest 74021 Design Pressure: +0/-142.5 Created by Independent Third Party: Yes } Other:See evaluation report for limits of use. Evaluation Reports 1f FL9777 R1 AE OCR14002 8a 2017 FBC Evaluationl Report Weatherlock Non-HVHZ.odf -^ __ --- Created by Independent Third Party: Yes flack NAX2 � Contact cls r:2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do notmant your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to;Section 45S.275(l),Florida.Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address ff they have one.The emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,FS., please dick here_. Product Approval Accepts: Wwal NO Bea ® i45e. 3S 4 I. I I i i ' I Certificate of Authorization bur 29824 C R K17520 Edinburgh Drive Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,C EDITION(2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017 1 Owens Corning Parkway Toledo,OH 43657 (800)438-7465 www.owenscorning.com Manufacturing Location: Brentwood,NH Houston,TX Quality Assurance: UL LLC(QUA9625) SCOPE I Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507-1.1 Properties: Physical properties REFERENCES Enti Report No. Standard Year. PRI Construction Materials Technologies(TST5878) NEI-039-02-01 ASTM D 1970 2015 � PRI Construction Materials Technologies(TST5878) NEI-042-02-01 REV2 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) NEI-045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) NEI-053-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) NEI-053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) NEI-093-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies(TST5878) OCF-237-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies(TST5878) OCF-252-02-0.1 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF253-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-272-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) OCF-296-02-02 ICC-ES AC 188' 2012 ICC-ES AC 48 2012 PRI Construction.Materials Technologies(TST5878) OCF-297-02-01.1 ASTM D 1970 2015 ARI Construction Materials Technologies(TST5878) OCF-3,18-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OGF-320-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) OCF-320-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) OCF-321-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies(TST5878) OCF-322-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST5878) OCF,355-02-01 UL 1897 2012 'Determined to be equivalent to ASTM D 226-09,Type I and II I I 0CR14002.8a FL9777-R11 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. I i CREEK OWENS.CORNING ROOFING AND ASPHALT LLC WeatherLock®Self-Sealing Ice&Water Barriers TECHNICAL,SERVICES, LLC PRODUCT DESCRIPTION AND LIMITS OF USE WeatherLock@ G WeatherLock@ G is an ASTM D 1970 self-adhesive underlayment constructed from SBS (Brentwood,NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq.rolls with nominal dimensions of 3-ft.x 66.7-ft. WeatherLock@ G is permitted to be lused.as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood,NH or SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- Houston, 7X) sq.rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@)Metal WeatherLock@ Metal is an ASTM D 1970 self-adhesive undedayment constructed from (Brentwood,NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock@ WeatherLock@ Specialty Tile &.Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tile&Metal constructed from SBS modified asphalt and surfaced with a non-woven polyester fabric. (Brentwood,NH or Houston, 7X) The product is supplied in 2.14 sq.rolls with nominal dimensions of 3-ft x 71.3-ft. WeatherLock@ Specialty Tile & Metal is permitted to be used as prescribed in. FBC Section 1507.1.1. WeatherLock@ Specialty Tile& Metal isl permitted to be used with adhered clay or concrete the roofing using either ICP Adhesives Polyset AH-160 (ICP Adhesives and Sealants, Inc.)or TILE BONDTm Roof Tile Adhesive(The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum m 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. WeatherLock@ G(High WeatherLock@ G(High Tear)is a self-adhered,underlayment used as an alternative to Tear). ASTM D 226,Type I or Type II roofing felt and ASTM D 1970 self-adhering polymer (Houston. M modified bitumen underlayment. The underiayinent is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. WeatherLock@ G (High Tear) is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002.8a FI9777-R11 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. .y CREEK OWENS CORNING ROOFING AND ASPHALT LLC V L� K WeatherLock@ Self-Sealing Ice&Water Barriers TECHNICAL SERVICES,LLC PRODUCT APPLICATION ' Min. Roof Slope: 2:12 in accordance with the FBC - Application: All underlayments shall be installed in accordance with the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the undedayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck.The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3"side laps and minimum 6"end laps staggered min.6-ft.from.preceding course. Additionally,if applying WeatherLock@ Specialty Tile 8 Metal, end laps shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to back nail the underlayment 12-inches on-center as.needed(nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Additionally,WeatherLock@ Specialty Tile&. Metal shall be back nailed when installed on roof slopes greater than 3:12. Min.Application 40°F;Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. i WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Undedayment System No.1 —Weathert-ock Specialty Tile&Metal Only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c. Undedayment: Weatherl-ock® Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions to the fastened deck and backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga. k 1-5/8-inch 0 tin caps spaced 12" o.c. The applied underlayment shall be rolled with a minimum 751b steel roller immediately following application. Maximum Design -142.5 psf Pressure: OCR14002.8a FL9777-R11 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed heiein. I CREEK OWENS CORNING ROOFING AND ASPHALT LLC C �L••aa WeatherLock®Self-Sealing Ice&Water Barriers TECHNICAL SERVICES,LLC i GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the-more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5). The space under the deck.area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used asdescribedin other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others,in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underiayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 6"'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. v���itu�trtrr� i'v.s€. s�.,� 2017.10.11 No 74021 "09:06:29 r r -�- -0400' p STATE OF :41: �,�'•,.� y..; �.`. Zachary R.Priest,P.E. iii '• O R 1 V.. �N�.` Florida Registration No.74021 % Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing. products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest,P.E. does not have,nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14002.8a FL9777-R11 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report.is valid. This evaluation report does;not express nor imply warranty,installation,recommended use, or other product attributes that are not specifically addressed he rein. I