Loading...
HomeMy WebLinkAboutThe Sands 29852FORM 900-A86 _. FLORIDA- MODEL ENERGY EFFICIENCY CODE a FOR BUILDING CONSTRUCTION BOB GRAHAM SECTION 9 GOVERNORS ENERGY OFFICE o GOVERNOR POINTS METHOD LEX HESTER, DIRECTOR PREPARED BY: BRABHAM KUHNS DEBAY— CONSULTING ENGINEERS PROJECT NAME AND ADDRESS SANDS BY THE LAKE JURISDICTION AIA - ST. LUCIE COUNTY _ APT: A a F f CrBUILDWG PERMIT NO - BUILDER SOUTHEAST ENTERPRISES, INC. OWNER CONDOMINIUM �TO It TO REF FILLED IN ILLED IN �YDalla11(^AL STATISTICAL DATA ZONE JVRISDI CT CODE FLOOR AREA GROSS OLA.Si WAL AREA WALL R-VA ROOF W E R COf MAXIMUM EPI 6 STD 1600 1500 490 0 12.5 .5y 2L.5 95 92 HEATING SYSTEM TYPE NOTWATER SYSTEM TYPE cox STRUCTION NUMBER of UNITS STRIP pSAT OAS' OIL SOLAR ELEC. h£CT GAt OIL /OLM C// FRAME THIS BUILDING EHTI C PRGJE T ❑ I ❑ ❑ ❑ ® I ❑ I ❑` I ❑ I ❑ © 60 1 60 THIS DATA TO PE SENT TO THE GOVERNON't ENERGY OFFICE by THE IUILDINI OFFICIAL UPON REQUEST Il f _ BASE BUDGET T COMMON W'ALCD COMMON ROOF VAXIMUM ALLOWED X12 = 95 —_ FROM APPENDIX E FEWER TOTAL .ANTE MEANS •REATEII SAVMSI E uI f CERTIFIED BY: DATE. 5/22/81 EPI : 92 9D DESIGN CREDIT POINTS(CP) CEILING FANS FIN CORD, SPACES I PER FAN MULTI ZONE A/C ('PEA Abu DOOR) 5 - OPERABLE WINDOWS °M E DR NO" SIDE a ROOM I PER ROOM 2 WHOLE HOUSE FAN 11 5 cfw/Erl S fi0fi�6 9E DESIGN PENALTY POINTS(PP) WASHER AND DRYER IM can SPACE) 3 1 3 MAX.OPENING OF GLASS( 40% S - TOTAL 3 9G MEASURES _P_ERSCRIPTIVE CHECK POR COMPLIANCE SECTION CHECK HEATING SYSTEM EFFICIENCY 503.4 XCfl AIR CONDITIONING CONTROLS 503.7 A/C DUCT CONSTRUCTION 503.9CULAY X❑ PIPING INSULATION- (CSTITEYs ) I TI 50310 WATER HEATER 1ASHRAE 60-76 LAJAL 504 2 SWIMMING POOLS 604.E O 40W€R i60W 4111 P10Y0RG 604 / E-D II / FORM 900 AND 901-456 RESIDENTIAL CALCULATIONS ZONES- 456 WINTER a11036 SUMMER I cno9f COMPONENT AREA X WPM -WINTER r01NTt COMPONENT AREA -fUYMER Y SPM - POINT Cf J 11,8 00 J u RS•3.9 13.7 985 Ra. 5.9 12, 3 Raeur 8,2 Rea up 11,< J Y wyw �m W u> R11-It.9 _ 4,.1 J-It.f u u ice= u C> 11,4 R19. i6.9 Z,y RI1r. 25.0 8,4 R266U► 145 RL9•ur 6,8 COMMON 400 9,7 3880 COMMON 400 6,3 2520 Ro-2.q 794 1t_S 15483 kD -?.q 794 V&b 118897 Co M600ORMETAL 162,6 WOOD OR METAL 45,9 o O INSULATED 150.8 O O INtULATED 18.4 STORM DOOR 76,6 ETo11M DOOR 36,6 o COMMON 81,3 C01/MO11 11.5 u Rtl-It•9 5,g u RII-If•t1118 RIf-tlt 394 Rif-tl.t 1tt Y1 R2!-t9.f 2, 7 R2t•2 f.f o a z FIX IS UP 2,2 R30a Ur 4 a z - 947 FIG. 7.9 1968 au — W ml- R6.9.9 7.5 RIO-Il.f 6,2 RIO-II.f 12,8 IdJ =p< W =W< V ^"<0 ... V „« ,- R12-10.9 1600 S,5 8800 R12-14.1 1600 9.3 14880 RIfeU► 3,4 R19suP 6,8 COMMON 6,0 COMMON 3,4 RO. 6.9 10,2 NO. 6.9 5,4 R7. 10.9 4,2 R7-10.9 u 0 u G i� ; pa,• t hll-I8.9 3,7 RII. 15.9 hW WK W n19euP 2,6 All sur 1,4 �Rop �o RO.t.9 6,8 O2oRO.2.9 12,❑ O, oc Y W Oz ki R3.6,f 7,6 R3.6.f 4,4 C 0 J= 1C (�=zi o RB-IO,f 5,9 LL.y V s R{-IO.f 3,1 RII-16.9 4,0 RII-16.9 2,5 u� u n- u >� R196UP 2,9 W O R19 &U► 1,7 COMMON 6,0 COMMON 28163 36297 — — 36297 EDGE INSULATION PERIMETERWPM GWP RO-2.9 60s1 R3-5.9. 45acl Lo R6& UP 30.6 low=®® lomm =I ©®mm-® ©®m©mlmm " 1 1 ®-MM-_ ®-MMC-2-�!I�-_ © ' 1 �mm : :: © � 1 mmrmm�_ m ' . -HORIZONTALJ 41111110106 4zalow TOTAL GROSS WINTER POINTS 73007 T0T4L 6R055 SUMMER ►DINTS 159770 � W I�FIBER OLABb 1.16 �„� I�fR1ER0 LAi/ I.IB _�� =<�'d" I.a�FIDE7tOLA5 1.12 I.8T F16E/1GLA58 1.12 p DUCT IN 73007 1.0D 730 f% 60CTa�caro,e 159770 1•00 11.59770 HSM FROM TABLE 9A 73007 X .33 1 24092 1 CSM FROM TABLE 96 1 59770 X .76 1121425 FLOOR AREA (DIVIDE); 24092 16001 15.0 1 FLOOR AREA(DNIOE) 121425,- 00 15.9 WINTER POINTS (WP) SUMMER POINTS(SP) FORM 900 AND 901- 436 WINTER POINTS SUMMER PONTS HOT WATER POINTS CREDIT -DINTS I PENALTY POINTS 15.0 + 7'5.9. — - — 2 + 3 = FEWER TOTAL POINTS ARE ENCOURAGE FOR MAXIMUM ENERGY SAVINGS ZONES. 456 92 EPI FORM 900-456 FLORIDA MODEL ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION BOB GRAHAM SECTION 9 GOVERNORS ENERGY OFFICE "�• GOVERNOR POINTS METHOD LEX HESTER, DIRECTOR PREPARED BY: BRABHAM KUHNS DEBAY -CONSULTING ENGINEERS PROJECT NAME AND ADDRESS SANDS BY THE LAKE FJURISDICTION AIA - ST. LUCIE COUNTY APT. E APT. B & E BUILDWG PERMIT NO - BUILDER, SOUTHEAST ENTERPRISES INC. OWNER CONDOMINIUM 1O99FILLED10BYDEa:aRu` STATISTICAL DATA ZONE JURISDI CODE FLOOR ARfA pR093 OLAS/ AREA WALL R- A ROOF INSULT R COP MAKIMUM EPI 6 STD.B C 1235 1240 266 0 12.5 8.5 2L.5 90 6 HEATING SYSTEM TYPE HOTWATER SYSTEM TYPE coNsJRrtu�'TION NUMBER OF UNITS STRIP PUMP OAS OIL SOLAR ELEC. RCCT GAS OIL /OLAR CB/ FRAM BUILDING PROJECT 01 ElEll ❑ ❑ ID ❑ ❑ 1 ❑ 1 ❑ El ❑ 60 160 THIS DATA TO GE {ENT TO THE GOVEPNDPY ENERGY OFFICE ■Y THE BUILDING OFFICIAL UPON REOVEGT BASE BUDGET COMMON WALLi COMMON ROOF MAXIMUM ALLOWED 100 — 2 X5 — 0 X12 = 90 /Aor An[NDIx E FEWER TOTAL PANT[ Y[ANB GREATER BAY111GB E PI CERTIFIED BY: DATE" 5/22/8 EPI 63' 10 9D DESIGN CREDIT POINTS(CP) CEILING FANS (IN CONO. GPAC[I I PER FAN _ MULTI ZONE A/C OEPEZPA AT A%L[D DOOM1 Br 1 S - -OPERABLE WIN D 0 W 3 ( oN E a DN Yoe[Root1 no[ / IPER ROOM 1 WHOLE HOUSE FAN (1.5 CFM/sr1 5 _ TOTAL 1 9E DESIGN PENALTY POINTS(PP) WASHER ANO DRYER INN CCNNO @PACE) 3 3 MAX. OPENING OF GLASS( 40% S TOTAL E3j 9G 1 PERSCRIPTIVE MEASURES CHECK FOR COMPLIANCE SECTION CHECK HEATING SYSTEM EFFICIENCY 503.4 AIR CONDITIONING CONTROLS 503.7 A/C DUCT CONSTRUCTION 503.9 IRC ULA PIPING INSULATION (Na4 ylus 50310 O WATER HEATER IAGORAE GO-TG LAG[L 5042 SWIMMING POOLS 604,E SHOWER FLOW RE STTIICTORS 004.E CD B-5 FORM 900 AND 901-456 RESIDENTIAL CALCULATIONS zoNEs-45e WINTER anoae SUMMER anoae WINTER SUIWER COMPONENT AREA 7' WPM POINTa COMPONENT AREA If SPY 7 POINTS F R3-3.1 11,8 R3.3.9 13.7 R4-5.9 9,5 u A4-5.1 12,3 JReeur J u 8,2 ASaUP 11,4 �J W�c R11-le.f 4,1 �J < j�,c Fr elf-14.9 11,4 R19-LS.f 2,1 All-ze.9 8,4 Q A m z W 3 <�x Rzeeu► 165 Rzglhw . o' ,,> COMMON 580 1 9,7 5626 COMMON 580 6,3 RC-2.q 358 1R•5 6981 RD-2.9 35$ Z1.b 1 8520 c WOOD OR METAL 162,6 Co WOOD OR MRAL 45,9 O: O INSULATED 150,8 0 INSULATED y8,4 O STORM DOOR _ 76,6 O STORM DOOR 36,6 a COMMON 81,3 COMMON 11,5 u MI-It•9 5.5' ^ RII-I6.9 c Rlf-!L9 3,4 R19-tL9 `9 ID R2L-Y9.1 2, 7 Rtt-29-9 c z R309 UP 2,2 A30aUP 40 m - z - R6.7.9 9,7 Rf.T.9 191 W mh• Re�9.9 7,5 ...: r,�u Aa. 9.9 ,111 RIO-Il.f 6,2 RIO-11.9 12.8 W o W < �4 W iM• V "ii V V „<s niz-1e.9 1233 5,5 6782 R1z•If.9 1233 9.3 11467 R19aUP 3,4 R19RU► 6.8 I 6,0 COMMON 3,4 LCOMMON __ __ — I I I r— RO-e.9 10,2 NO. 6.9 5,4 R7-10.9 R7-10.9 492 u G a~ O ; k11. 1e.9 3, 7 ,a., s RII- 10.9 v1 W R19euP 2,6 W AI9suP �_< �c �" RO•E.9 l21G --- O �o<° y r R3.5.9 7,6 DimcommON =, AB•10.9 5,9 �Wo hl� u RII.le.9 4,0 4.D 3,1 _ > W0 R190.UP 2,9 >2,5 1,7coYYON , 13 663 5726 19998 T747 37 365 23640 mom EDGE INSULATION PE RIME TE WPM GWP R0-2.9 6�•1 Q Na R3-5.9. 45�9 R6& UP 30�6 a® ., . .-MEMO • Immm®�®® mu ©- '®m_ i-_ ®m '®■m_ mmmo NN_ ©® '. �7 om■ m ©®mods +�2M o.,�,9�W := ©-®®m ©m00�m ONE IM■■EMN e : W-MEN 0���� ■mmommm � Is��� ■ENEININIENNEEN IMEMEMEN IMMEMEMME ■IMM■iNEINIMMI ®NMMlE ■NIME10101=111MIN HORIZONTAL GLASS ( SKYLIGH1•J TOTAL GROSS WINTER POINTS 28607 TOTAL GROSS SUMMER POINTS 83485 W 1'FIBERGLAS8 1,15 �„ , t`FroERGW6 1•I6 I6EROLASD IJ2 1.6`►IB£R GLAtS 1.12 =a� cTeRtaro. 83485 Loo 83485 ®i DUCT INC0110.6 M...1•00 28607 UNSM FROM TABLE 9A 28607 X .42 1 1 201 5 ' CSM FROM TABLE 90 83485 X .761 63449 FLOOR AREA(DIVIDE) 1201 5 11235 9.7 1 FL0011 AREA(DNIOE) 63449 --1 2 3 51 51 .4 ,tow WINTER p01HT5 (WP) 9 , 7 SUMMER POINTS (SP) FORM §00 ANO 901. 456 ZONES. IDS WINTER hOtHT4 SUMMER POINTS 9.7 + 51.4 FEWER TOTAL POMTS ARE NOT WATER POINTS CREDITvOINTS PENALTY PONTS — 0 _ 1 + _ ENCOURAGE FOR MAXIMUM ENERGY SAVINGS B-7 •..,. 63 EP( ` FORM BOO. 456 ,, FLORIDA MODEL ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION IL—` BOB GRAHAM SECTION 9 GOVERNOR'S ENERGY OFFICE '��. o' GOVERNOR POINTS METHOD LEX HESTER, DIRECTOR PREPARED BY: BRABHAM KUHNS DEBAY —CONSULTING ENGINEERS PROJECT NAME AND ADDRESS SANDS BY THE LAKE JURISDICTION AIA - ST. LUCIE COUNTY APT. C & D I Hti BUILDING PERMIT NO. BUILDER SOUTHEAST ENTERPRISES INC. OWNER �TO It FILED IN IV CONDOMINIUM TO ME PILLVO IN IV LDt111Nt RUL STATISTICAL DATA 20NE CODE AREAR OROSB LL 9LABB AREA WALL,) ROOF MI E Rral COP MA)QMUM EPI 6 ISTD.B Cl1308 11264 1 270 0 1 12.5 8.5 12.5 90 1 73 HEATING SYSTEM TYPE JHOTWATER SYSTEM TYPE coNsTR�L� ON "BEM Of LIMITS STRIP HEMP OAS OIL SOLAR ELfO �CCT 9A$ OIL SOLAR CBS FRAME BUILDING PHOJE CT ❑ ® ❑ ❑ ❑ ® ❑ ❑ ❑ ❑ ❑ 60 60 TH16 DATA TO If 6ENT TO THE 60YERNOAY ENERGY OFFICE IT THt BUILDING OFFICIAL UPON MEOUE17 BASE BUDGET OOMMON WALLS COMMON ROOf MAXIMUM ALLOWED 100 — 2 X6 — 0 x12 90 FRO. A ENOI%E FEWER TOTAL PaNTI WAN$ GREATS)) SAVINI01 E.PI CERTIFIED BY: %� DATT-5/22/81 EPI: 73 9D I DESIGN CREDIT POINTS(CP) CEILING FANS (IN COND. "ACFI I PER FAN _ t EPA n ATtD IY MULTI ZONE A/C: OPE6 AI LE Door OPERABLE WINDOWS °M t on woq[1 IIDt OI ROOM 'PER ROOM _ WHOLE HOUSE FAN i1.6 CFM/1F1 S _ TOTAL 9E DESIGN PENALTY POINTS(PP) WASHER AND DRYER INICOND $PACs 3 3 MAX.OPENISO OF GLASS( 40% 5 - TOTAL 9G PERSCRIPTIVE MEASURES CHECK FOR COMPLIANCE SECTION CHECK HEATING SYSTEM EFFICIENCY 503.4 AIR CONDITIONING CONTROLS 603.7 ® _ A/C DUCT CONSTRUCTION 603.9 PIPING INSULATION (CIRCULATING) I T GTIwi I 503 10 ❑ WATER HEATER IAIHRAE SO-t1 LA040 504 2 ®.. SWIMMING POOL$ 604.E a SHOWER FLOW RESTRICTOR6 504.5 X❑ FORM 900 AND 9o1-456 RESIDENTIAL CALCULATIONS ZONES-458 WINTER e'0se SUMMER GROSS T WINTER SUMMER COMPONENT AREA % WPM POINT{ COMPONENT AREA % SPM POINT{ co r u ou. R3-3.9 11,8 J U v R3.3.9 13.7 R4-5.9 915 04.5.9 12.3 R60UP 8.2 Re\UP 11,4 J X W V W �m W Ru-1r.9 4.1 J 3 L`' W W iF�� Ru-16.111, 11.4 RID-L6.9 211 R1/•ES.f 8,4 R28SUP 195 REef,IIP 6.8 COMMON 864 947 8380 COMMON 864 6.3 5443 Ro- 2.9 1 30 14LS 2535 R0-Z.9 130 23.5 3094 co WOOD OR METAL 162.6 - WOOD ON METAL 45,9 OINSULATED 15a.8 Q INSULATED 18.4 STORM DOOR 76.6 STORM DOOR 36,6 O O COMMON 81.3 COMMON 11,5 u Rll.lr.f $.5' Y RII•te.f _ F R19-{I.f 314 .4 N1e-{t.f R22-z9.t 217 Rzz•zf.r 0 R30IS UP 2. 2 Z' R30 R UP 40 to R6-T.9 9,7 Rt-7.f 1918 m •' au >u W m� n6,-9.9 7.5 J W�- r Rt•r.r ib< _ W %Mi RIO-IL9 6,2 R10-ILf 12,8 lJ v ""<$ V. ^ii nlz_1e.9 1308 515 7194 R1z.u.r 1308 9,3 12164 R19eup 3,4 RIfRUP 6,8 COMMON 610 COMMON 3,4 RO-6.9 10,2 RO. 6.r R7-10.9 W RT. 10.9 4.2 u G a=i R19DUP 2i6 ° Rirsur1.4 61C Qcu R0.[,r cco 1210 O�Ro•t,9 ° _Jo< W Wmwffi OzA� D 1' �i�Ltj0 =Jumo WO 0(y= u O>cu Rt-10.9 311 >COMM°R19SUP RIt-le,f 2,S 1.7OMMON 18109 20700 I 1A1nQ 20700 ---- EDGE INSULATION PERIMETER WPM GWP W C ai R0-2.9 6011 R3-5.9, 4S,R -j�= NOS R 6 & UP 30,6 . :- ` . Nunn - .• - = loommom -_ ®-mm—_ ommm A! .�_ =- © ' :�mmm • ' © ' mmmmm l mm 'mf __ mmm "'I mmmm ©mm® �� ammo llmm■ mmmmm� mmmommm� a • � � = :: { a • • om2rjsm- RON E ©mmmm� mwoemm� mm�wm� a■ mu -- mm■ mmmmm� mmmmmmm� mm�mm� ■mmmmmm� mmmmm� ■■ mmmmm� im=i■=� mmmmmmm� mm■� =� ■mmmmm�� HORIZONTAL.. .. TOTAL GROSS WINTER POINTS TOTAL GROSS SUMMER POINTS 9574 ��u DV , LID � , VeLDEE1YLA{ O I" I"FIBERWS 'FNElM uDODCC 43003 1.2 1•00 —^ 43003 OFLD { 1L.1I2D CT1Ncaro.{ 95745 1•00 95745 HSM FROM TABLE 9A 1 \43003 X42 1 18061 CSM FROM TABLE 98 95743 x.76 72765 FLOOR AREA (DIVIDE) 1 180.61 -�13081 14 1 FLOOR AREA(DIVIDE) "1 308 56 WINTER POINTS (WP) SUMMER POINTS (SP) FORM 900 AND 901. 456 WINTER POINTS SUMMER POINTS 14 56 FEWER TOTAL POINTS AR€ NOT WATER POINTS CREDIT -POINTS PENALTY POINTS — 0 — 0 + 3 — ENCOURAGE FOR MAXIMUM ENERGY SAVINGS ZONES- 456 >. 71. EPI B-7 FORM 900- 45 6 0T.- FLORIDA MODEL ENERGY EFFICIENCY CODEFOR BUILDING CONSTRUCTION BOB GRAHAM SECTION 9 GOVERNORS ENERGY OFFICE GOVERNOR POINTS.METHOD LEX HESTER, DIRECTOR PREPARED BY: BRABHAM KUHNS DEBAY - CONSULTING ENGINEERS PROJECT NAME AND ADDRESS SANDS ON THE LAKE JURISDICTION AIA — ST. LUCIE COUNTY APT. J BUILDING PERMIT NO. BUILDER SOUTHEAST ENTER RISES Inc. OWNER IT LDEIIIME RDO UL l LLED IN By CONDOMINIUM To O fFILLED IN STATISTICAL DATA ZONE JURISDI CODE FLOOR AREA OROSB WAL OLJuSf AREA WALL R-VA ROOf E R COF MAX]/IUM EPI 6 STD. 1 830 828 224 0 - 8.0 83 82 HEATING SYSTEM TYPE HO'TWATER SYSTEM TYPE `2l,.5 coNsIRA6 TION NUMBER OF UNITS STRIP pEMp GAB OIL SOLAR ELEC. pEg OAS OIL SOLAR CBS FRAME BUILDING ENTIRE ❑ ® ❑ ❑ ❑ D ❑ ❑ I ❑ I ❑ ® ❑ 6o 6 THIS DATA TO BE GENT TO THE GOVERNOMS ENERGY OFFICE BY THE IUILDINI OFFICIAL UPON REGVEGT BASE BUDGET COMMON WALLS COMMON ROOf MAXIMUM ALLOWED 100 — 1 X5 — 1 XI2 = 83 FROM A EMDINE FEWER TOTAL fOINTI MEAMI IME4T01 IAVIMII - Eft CERTIFIED BY: pit; e. DATE �z�' EPI : gz t 9D DESIGN CREDIT`POINTS(CP) CEILING FANS (IN COND. rRACE1 I PER FAN _ MULTI ZONE A/C (IEFARATID IY ORCMILE DOOI1 OPERABLE WINDOWS ON E OR MORE) slog of Room 1 I PER ROOM 1 WHOLE HOUSE FAN 11.5 CFM/IFI 5 _ r ' TOTAL 1 9E DESIGN PENALTY POINTS(PP) WAGNER AND DRYER IIM CONO IRACII 3 3 MAX -OPENING OF GLASBC 4^ S - TOTAL 3 :0 9Gj PERSCRIPTIVE MEASURES CHECK FOR COMPLIANCE SECTION CHECK HEATING SYSTEM EFFICIENCY B03.4 AIR CONDITIONING CONTROLS 503.7 A/C DUCT CONSTRUCTION 803.9 PIPING INSULATION (CIRCULATING SYSTEMS 1 50310 O WATER NEATER IAIHRAE 10-7I La1EL 504 2 SWIMMING ►OOL$ 004.E SHOWER FLOW RESTRICTORS 504.5 X❑ FORM 90o AHD 941-a5$ RESIDENTIAL CALCULATIONS zD1+C3-456 fai J �W.. uR4-5.9 z 0 RS-S.f 11,8 J a RS•3.g 13.7 9e5 R4-5.9 12.3 nQaur (jet RfaUP 11.4 u� m a K d W °> R11-Ig.f 4 s 1 �i= �W a Y i q e 4 `O> RII-I6.0 11.4 RI9-26.f 2:1 R11-25. f 8.4 Rz6aur 115 Ref%Ur 6. COMMON 640 9,7 COMMON 640 6,3 4032 6208 4485 Ro.2.9 230 JR.S RO - ?A 230 716 5474 BLOOD OR METAL 162, E INSULATED 150.8 STORM O09R 76,6 COMMON 8193 u RII_10.0 S,S" RIB-10.011.8 _ RVf-f1.0 3,4 R10�11.0618 R22-29.f 2.7 n22-2g.f p R308 UP 2.2 A30 a Ur 4. 7 fa Ca R8-7.9 9.7 a R6-7.0 v yu m,- J yu a1�F R5.9.9 7,S Rf-f.f W e w < ilk a.9 Rf0-ILf 61 2 R I 0- 11. f 12.8 uJ E a _ v nla-1e.9 5, 5 _ R12-10.0 9, 3 R19a Ur 3,4 Rlfa Ur 6.8 COMMON 830 6.0 4980 COMMON 830 3.4 2822 RO-6.9 10,2 R7•10.9 4®2 R7-10.9 _ p 0 u aa~ 3 < +� ® 9 RII. 15.9 3.7 RII- If.9 a W pd p a R19 aUr 216 Rig aUr p2� R0.2.9 1210 ®p RO•f.! 618 JO< C �n -.. R3.b.9 a,6 pa•a,It �1t G. 10.9 S,9 4. a ;p u RII-1f.9 41D O Rt-10.9 341 u R11-1f.9 2.5 ° R19aur 2 99 > - R19 &Ur 1.7 COMMON 6•0 COMMON ' 15673 12328 tea^; EDGE INSULATION PERIMETER WPM GWP ©oW ZO. 2.9 40 60.1 2404 .yew �o< R3-5.9 45.9 R 6 & UP 30,6 a o N z Q r z m � a a e F O x O O r OR AREA SINGLE DOUBLE WOF GWP o a x 0 co w O 6!9 c ac a z � j a ♦ < h0 X U O OR AREA SINGLE DOUBLE SOF GSP CLR TIN CLn 71N N 101.3 67.2 N 76 149 14 4 NE 1➢1.3 67.2 NE 263 221 E 94 - 101.3 67.2 .93 8855 E 94 3g. 129q 30 .73 244�'8 SE 101.3 67.2 SE 333 285 29 45 9 130 101.3 67.2 87 11457 3 130 272 229 2 93 7 25813 SW 101.3 67.2 SW 339 285 29324S W 101.3 67.2 w 39. 2� NW 101. 3 67.2 Nw 263 221 N 3.5 -21.2 N ;i 494 H+HORIZONTAL GLASS LSKYLIGHTS) FOR TINTED GLASS SL{A 0.83 SEE SEC. 902.2E TOTAL GROSS WINTER POINTS 38389 TOTAL GROSS SUMMER POINTS 62569 I w I"FOBER4 LASS 1.10 r I'FiBGLASS E:n 6.16 F LS�F. ISERGLASS Idd =a��-; LS"FiBLn GLASS 1.12 pucTINCOeO.B 38389 1.00 38389 ® ... _ -,- vi CTIRcONO SF 1.00 Avow -Qwoo� HSM FROM TABLE 9A 38389 161 23A CSM FROM TABLE 98 FLOOR AREA(pIYIDE) 1 6123 'T 830 16123 FLOOR ARE A(DNIDE) WINTER POINTS (WP) SUMMER POINTS (SP) FORM 900AND 901. 456 WINTER POUITS SUMMER POMfTS N07 WATER POINTS CREDIT• OINTS I PENALTY POINTS X.81 50681 T830 61 ZONES. 46 82 EPI BUILDING PLAN CHECK ST. LUCIE COUNTY -FORT PIERCE FIRE PREVENTION BUREAU FORT PIERCE, FLORIDA 33450 TELEPHONE 465-6655 DATE RECEIVED: CONTRACTOR: Cer enni G in"n. _&c PHONE NUMBER: 9*10719&k/ r ARCHITECT: J®ny'e aw'_oA Du cj4 Y PHONE NUMBER: OWNER: rvLe 5wy e/s /'ee.r u .0 %e.,.�i.,,s .� ip - 9 8y✓ LOCATION: /l ,pI,4P TYPE OF OCCUPANCY: TYPE OF CONSTRUCTION: //, r(r!i SIZE OF BUILDING: /so'Aw NUMBER OF FLOORS: sYI+...:fa RECOMMENDATIONS: Soc.e - �Z .._' -- — CONTRACTORS RESPONSIBILITY TO NOTIFY BUREAU ON ALL INSPECTIONS` REVIEWED BY: gc/ //O Signature DATE: FOAM 1195 - PRINTING BY GMRN LEGEND OF SYMBOLS B MATERIALS SYMBOL DESCRIPTION CONCRETE BLOCK REINFORCED CONC. DRYWALL PARTITIONS WOOD PARTITIONS OOR NUMBER B—basement I G —ground fl. B FLOOR LEVEL DOOR SCHEDULE T—typicalfl. PH -penthouse SECTION LETTER R—roof A OR NUMBER SHEET WHERE DIRECTIONAL SECTION IT APPEARS CUT ( FOR PLANS) SECTION LETTER OR NUMBER SHEET WHERE SECTION DRAWING IT_A.PPEARS I DETAIL NUMBER _IDENTIFICATION A I SHEET WHERE DETAIL IDENTIFICATION IT APPEARS SYMBOL ROOM NUMBER B—basement T G — ground ff. FLOOR LEVEL T—t of — PH -penthouse FINISH SCHEDULEIR—roof o WINDOW OR SCHEDULE N _NORTH ORIENTATION ELEVATION IDENTIFICATION N D E COVER INDEX C1 Paving and Grading Site Plan C2 Paving and Grading Details C3 Water & Sewer Site Plan C4 Water & Sewer Profile & Details ARCHITECTURAL PLUMBING P-1 Plumbing Site Plan P-2 Ground Fl. Plan ST. LUCIE COUNTY - FORT PIERCi FIRE O'STI'IrT P-3 Typical F1. Plan - Levels 2 through 9 .,, IRE PREVENTail^i L3f'fREAU f .�fia�. o•, a y P-4 Roof Plan - Level 10 fon CQ-~s 5/�rtT P-5 Ground Fl. - Tower No. 1 F� �drp«?'A� cue ARcI,e4 SUBJECT TO All s P-6 Ground Fl. - Tower No. 2 1. SOUTH t'2. NFrH NO. Ili Ei1 c DEL P-7 Typical Fl. Plan - Tower No. 1 P-8 Typical F1. Plan - Tower No. 2 P-9 Sanitary Risers Firejwarshal P-10 Plumbing & Fire Protection Risers P-11 Domestic Water Isometrics P-12 Typical Plumbing Details j�.. Al Site Plan A2 Ground Fl. Plan Level 1 A3 Typical Fl. Plan Levels 2 to 9 A4 Roof Plan Levels 10, 11 & 12 M E(,.HAN ICAL A5 Ground F1. Plan Tower No. 1 A6 Ground F1. Plan Tower No. 2 A7 Typical Fl. Plan Levels 2 through 9 Tower No. 1 A8 Typical Fl. Plan Levels 2 through 9 Tower No. 2 AC-1 Ground F1. Plan - Level 1 A9 Front (East) & Side (North) Elevations AC-2 Typical F1. Plan - Level 2 through 9 AID Rear (West) Side (East) Elevations AC-3 Roof Plan - Level 10 AC-4 Ground Fl. Plan - Tower No. 1 r All Long.& Transv. Sections AC-5 Ground Fl. Plan - Tower No. 2 Al2 Wall Sections 1 & 2 A13 Wall Sections (not used) AC-6 Typical Fl. Plan - Tower No. 1 AC-7 Typical Fl. Plan - Tower No. 2 A14 Bathroom & Elevations AC-8 Riser & Details A15 Kitchen Plans & Elevations A16 Stairs Details & Trash Chute Details AC-9 Schedules & Details A17 Finish Schedule A1S Partition, Door & Window Det. A19 Door Types & Schedule ELECTRICAL A20 General Details �s E-I Site Plan STRUCTURAL E-2 Electrical Ground F1. - Level No. 1 E-3 Electrical Fl. Plan - Building No. 1 E-4 E-5 Electrical Fl. Plan - Building No. 2 Roof Plan S-1 Foundation & Ground F1. Framing Plan - Level No. 1 E-6 Main Electrical Riser Diagram S-2 Typical Fl. Framing Plan - Level No. 2 S-3 Typical Fl. Framing Plan - Level 3 through 9 E-7 Apartment Riser Diagram E-8 Fire Alarm Riser Diagra1t S-4 Main Roof Framing Plan - Level No. 10 S-5 Typical F1. Rebar - Level 2 through 9 E-9 Riser S-6 Beam Schedule & Roof Tower Framing Plan E-10 Risers- E-11 Legend - Details, S-7 Column Schedule E-12 Calculations S-8 Pile Cap E-13 Calculations & Panel Schedules S-9 General Note E-14 Panel Schedules & Fixture Schedules 5-10 Sections & Details 5-11 Sections & Details d L'feT � • r.A1D IG J__ US. Al-e 2 C./ U. I< S. A./' 0 on 4- (Not dipped go/vor�izcd� k-A Two 3/4"rhrcodod Pods — C1 T(=(= 31c:)c:L-_5 To TYPICAL FIRE HYDRANT ASSEMBLY VALVE SETTING DETAIL NOT TO SCALE NOT TO SCALE p14jg.5_ of end of of type of Joir�f. CONCRETE ANCHOR DIMENSIONS PIPE SIZE "A" DIM. (VERT a HOR.) 1 6 11 2. - 0 // j� j Qr Ck ­ GENERAL NOTES- 1. Site information obtained from plan prepared by CFS a: ciates, Inc., Job No. 731-T, dated 4-18-80, E. Brett C,, R.L.S., Florida Certificate No. 3333. 2. The Contractor shall obtain all necessary city, county, c,. state licenses prior to beginning construction of the worl:. If special permits are required for..any part of the work, they shall be obtained and exibited. The Contractor shal.. give all notices and comply with all laws, ordinances, rui_,, and regulations bearing on the conduct of the work as drawn and specified. 3. The Contractor shall verify existing utilities in the and notify the utility companies in the area before beg4-,, construction. Contractor shall check with gas compaliM.1.1-1 location of buried gas & fuel lines in the area. 4. The Contractor shall submit at the prework confi proposed construction methods and progress view. 5. Contractor shall subictit for review iht!p dra-, wet well.. pumps, electrical fea,.ur,�s and ataa,- rature for all hardware and spec. al fabricat:Loil i.e !i 6. It will be the Contractor's resi�a­_-,ibility, as pc_:L of the work to be done, to coordinate his w�,r;.'_ �,t:h work being installed y other contractors and su *Cantr lr_ tor s. 7. The Contractor shall maintain an ace rate log of Construction progress data and submit it to the-1 rineer upon completion of the. job for Fngineer's use in n,; record drawings. 8. Maintain 10-foot minimum horizontt.,l I between wat-3- lines and sewer lines. Whece wal_­r ris osn SeNier. I with less than 18" clearance, sews z !,j.je. sna'-11 i,e j*. tinuos length for a minimum of 20 fc,3�QL ca-r iron concrete encased, 10 feet on each Of CIOSsic. �, 9. The Contractor shall notify all 10C.'ai reg'"_LaLory arc--ic.ies 4P hours prior to the startofconstruction. 0. Contractor shall obtain satisfactory test results for bater Distribution& Sewage Collection Systems. If a test(s) fails to pass the requirements, the Contiactor, at his own expenses, shall repeat the test(s) until satisfactory results are ob- tained. 11. Concrete used throughout the project, including thrust blocks and general, shall have a minimum strength of 3,000 psi, and, a water -cement ratio which will produce a slums,, f 3 to 5 Ld m ol e TRC 10 PLAN mmiii SCALE: l"=30'-Ci" U z �� A .1 1 W _ U�r4 n : a/, Q Z 4 M W N o z m J a N O 10 11 � z Q Q U ¢ Y = (L a U) o U ¢ z Q. W F Li EIIN —+ a _.,.� _ _ s. J—D' 'i� y� �- � � - _ _ _ _ —___ -- ; - -- — - - _ — Itl f V ' _ / ELEV. LOBBY N•1� �-'�J lj '. �\` • _ �p � �= �---� - � )ELEV. LOBBY N 2 ,�� 1 - - -- - - - �I c+T o o -- - E E L +`-- ENTRY r ENTRY LOBBY.SEC. LOBBY ELEV.1 ;ENollEV.2 N•�� N•2 ELEV.3 ELEV.4 rAPT. _ __ _ TYPE r , UPS i llP ,offI} nt1P �-; l0 J ��� - -- I .1 APT. TYPE? ;�.. _ -_ - _ -- j_ - i i r !J �, i _ _ r � I r � _- � , I 1 K . _ RM . 1 STAIRN I:JSTAIRN -- • •4RB. es A _ —� STAIRN• �STAIRN• R 2 !8UIL1J1 G ABOVE _ 1 ,r Al PUMP. J RTRAN ( SWITCHGErAR EMERG. GEN. i ROOM &PUMP ROOM -114 e pd • N - — , I 1- r. . A -I 1 r W II 5 TOWER N i� - — TOWER . NO ....,._._�_.._ I I .. is r e .... ,.. ,.x :..... .. , ?.. .., r......+. _ , n ... .: ,.. ... .. , ... 5, A.. v r r ..,. I.. i ... .r y ...,. , ., a.. e S x Su . e.. .. i'•. rf ., p n `. .. I { a .... n .. 3 v , ,. , .e.. x .. ... r .::. ., _. ,n C x r �u.. ,.. .... i". f ..e. , Y .... rc �.n �-I r .. 4 w t .n: r aL a-. ,.... . ,p.�r _.' v a _r:. -4.. 'i . ._ r, v s. S Fl. .• ,.., ,. ,.... i.. � 'a .. .: .v k., .,, i .. ..... .. N:.. ,.. _c., a .. J'J .( ,v . ,. ...:: _r ... , d... ,. .. � �:.. r :, ...d Y _ ,,, ,. ,.., , e, ra , . 'S',. '3 , `:. 'R"- ,. ,..r: .. ,... +. e. „... ,,. .. '4.. _..:fi ra a .. .., .. r. .. 7Y.. :. .... ,.. t . ,:.......• >_ .. .. a.. :.. s. . .... .., M, ..:... .., a ,. 4. -,:_. .m, w. .:5 �.. _. ,:... , r*.. fit. <. ... t. ,_.. , ...r � ,.. .. r `ro ku. r.., f 4T ..: .. YX. n, v ..e _.'t. .. ._ a i `Y3.. ka:. .e. ., .b.... rv. , r n. P fir��.. °F.: ., .. rt�„a' .. ,., ... MIh ,. . n.... � n , ... , f ,. _.: { ,...... r .:. vr.• 1. J n va ... :.. ,.. xr -w -, , k:. 4 .. v, ry . ... ,. i„ ! to , .. :..,. ]� C . _.. iH._. .. .. . % 'rh .. ... � .:. .. 'is'. V °1. ,i. x .:. _ C ,•� :r .. r. x.. Y# .. _.,.. < n ..:+, , ,.i .. e 4 :.. 4 1 d :.:� :r ..� Y by ,. s.,.,. _. e. .. ,. S < -'-i4 •.. �+'! �n... - .. 4 .... n ::.:. � .. .... � 1 ..�.,ca , ry ,:. , v ....d r. : „§ .. ,. ,... ,tS, . „ .. ,:,,.,.. ., � 6• , ..nFa. r 7rr _ C., .,.,_ - u'_.. d ,..'t"n ., , .'kr.'.,... t .ir 1 n.. .., .,.. r , .:.. ,.. ,v a v 5 .. ..i, a ..:.._, , >..,.. ,,... .. ,. .. P.. ,.. a s.r. ,..: +, " L r F -• r�, ra..„,rv&, V �@ ., d�:i $1 . �.. ;,_ ,.n•.... 3a Iw �.waAu WrK� 4..:.r :l ,. r �.: �... F.,r..r :.. .. .;>t F LL Q UQ o� No NQ Q� '�1 m w N U) co (, Z m0 I � � i' I it � �t-10" IV _ � 2 � A�-Iy I ' ¢Ire 4�• 4 14"-Q� 4F i 121' ) dip, -" �_. �vU I'Y °`� 121-�11 * LIVING k DEN MASTER DINING g 1 3m BEDROOM ; i i I - I APT g ° APT. --- _ ----_ _ �;� I �� 'TYPE i 35 i.l TYPE, ,. . , I 121_� , _ y . Gh i -.. - - - ---- 4—'g-4- itCLr , i TLIVING KIN ROOM ll ., --- - -- ! r t r4 OR SS&G W. — , B TS H ; � HALL I i ,F T _ N ,6 , i (/ 40�, - 33 44� '� AUNDR�e _� k G1 D 1 N :.INEN --- FOYER w S-1p D_ i .,1!0 I r0ev'E R l_ I i --- -�iLx, SATI - — _ — - - — I i_ O i -1 No —_ I --------- 2� -- -� �: ELECT. i BATH , �1L 6 '7 a` " I \ BATH , L __�N. No TERR CE DRESli p ` t� KITCHEN ,r'' it ELEV. 1.08BY N•I— i L��EN --- - ----- _ At / T! IL - J P I a — — - I i 4 � �;.� ENTRANCE ,-}✓�-_;?r��---Y`.---�1 I , LOBBY OBBY . .�N-�_,•�_ —1ELEVATORSHALL li; �14 G,4 �FOY�ER LIVING CH)-- if - ._ _ i_2..-� �_•i ._ ___ - -r' ffIFf °O _ . , ' MASTER CnL aBEDROOM + ' i , A : 9 I ! APT Cj I -� U I - TYPE D (LAUND YI i O' I _ Ezit � 1 siIMiUP,k 11 1 fC1~/ DINING _ a_1 11 +, BATH I G+ �'- " 5 3 b �a' n r , C.-2 M.o. -� _ , )N• I �, BATH ; GARBAGE N•2 IN•i - -� - -STA STIR N• 2 IR N• 1 - --- - - - — - — Jli 7717 Ell U H 1171 _L I'� BREAKFAS_ : I ; � I P7� - _ CL .L1 5i DEN I CL. BEDROOM I I PUMP ROOM 'RF4F I - ii a i CL. It — T RA.�i TERRACE 1 E'�l '"•°' N- - _— _ -- --- - --- — --- ` 10� pN 1'tr�l.-¢ lr/�2,c'.VL DIM�►.� d�N. � I � GROUND FL. PLAN -TOWER N•i— _ SCALE:1/4°=I'-0°_ t`��'�"•. i MFt F;i��RATE�.p� f�,R?tT:.�N'8 se '5HT. A-' I "I FOFi �ir`i1 H SGH>;tiuL L ' A I FOR POO L `.-G"EC7vL_m �.. ''• -, _- +� P', '- I � _ 1'°;� _fars'`r.'��"'t'1°j-�'�a� J%d�i'c '�:: m/Ij"�pD�✓-.._a'i N sEE ;HF-e.TA. Tr» f/d". 15GA A a0 IJ1 QI r BATH' HALL ^j 1 f � �'4 BATH � 1 ��,.� �I �87— G' fE !. . , 82 r � 11No 7 4�ls� DRESS6 `�i1 ELEV. LOBBY N•2 ;: d upo 4., . w i 1 D KITCHEN r- t sumac - _ Ir 12i,2a �' it ,{ it `rj'II ( 1 .pit ICU 1 I p f It 1 MoN � IGt to 8 _ T r �ea3fi" r( 4 FIRE ��� J_ I t _ — DEPT. 4 suMp �t{��r,a� -� �I ENTRY i I �+ CL. N� G LOBBY HALL ( p N' 2 �� ; 'I.I. � . , '` � a C. r� , � {._._ G� �' �3 ER _,,_ ; •, I s .. -- , r i q 1 q�'- 1 R A 1""yl :, ir... ,' ,• n n 11 S� ro z 4-0' f © E LE VA'FORS s3.4 Ys.4 0 3 a BEDROOM D° 3-� �5 'a \ 1� µ2M- :, L 1V I NO 9 I --r , f > �; �'�'� i � �° Ir, ul — t G �r_-a-•-�-•-a � `»Qn V'K �� }'{ DINING a 1 I, o STIR N•3 i 3'�141R N•'4� `� GN aN t �' APT J Q, �. �p �4 x i 0 I y V✓ I *: � 1 � �. (:: � , , x � `� � -ol I � � �� - -F; �g� � � t * �Y��, _TYPE tlD o - ,. } _- � �, - I --- T � _ UP I 1 (1 Tr 4T 5`_':�a_.._ ,� 6'•Z" u � II i � _- ., y..� � _� ..._.._ f _ €. i, °13 � � \,� � j G � f I fi - , GARB.RM. '.9 I, BATH { - - I s � BEDROOM ACE _ � TE ' 9 , 3g I �� � f 1 � l � � ' I. 11' ij.�� L_.. _.. ' ,'_.. ' I-{ 9 ,., _ _i I I \l r• -. 11 11 _— _� �,�.... _ I ( i i 14-4" n ED&E op Pip l�crrt S j -- - +� _ t `Z._ _} „ t . - - -- --- , I. �ffaFT�h a 4-_1F-��� lit DRESSG NOT t,5z— �. FA%R- '1'Ci0- �. 2 HP,.- l9 — = P.• I 1 Fob —, . ; 3f-f Sct-ID- to — 6E :514F.ET �Z Z 5Or4D, AND CET1"JL`3 t�DfXlF- wrND©*/ I D�r�lc- i 1FRANSF. f SWITCHGEAR RM EMERG. GE( ER. a 01VA0T �, to � �.��.��.,�,�.L � PUMP ROOM BALCONY �Qr- oil 1 BALCONY - --- �--' - — - - _ - — I .i Sy _ _ _ . c_ . �N � wa HxT � t.E ve�4 17 _T 1 �, on 7 4f.4' r'-fir IS,O . j- . _ �_ _� - �� ' �'�4 D I /11 y4' f 14 1 0 �— _ —13 n I �.2 i ,� ',> T / `b 2 . p• 0l4 Ci T ^ti f I It e t �' M 4 11 ,�i fin, Y'' '.^"•Q7'� ., �.i _e - r DINING _I LIVING DEN MASTER, APT. �, ;. - �13 _ I " t TYPE 6E�ROOM .E _ f 1 l I Im, t 4.0 ' I T APT i CLN: `I I LIVE G %� j B . T + d ROOM 14'- KITCH Op 1 , ' TYPE -N' 4 4+ - ORESS'GI _ _ j46_- I , � Q - �- �_� -a� g I 4tr if�n Sl,dI } °q," z -� HALL 15�T = P I DINING * T _ -� - - — - - 1 W.I C. T .�J l — — -- — -- ' I �! r 31 FOYER 9 �, 4: _ v Q -t. ___—jr^ or(1' f - ( •f' j �tii If"!I Itill T M • 1 , I Ii 10n G! 011 �' r}, ap T , 61-4� f j 7d Kt i rd t "l+ir 4n 3,� �r : I FOYER _ B/4 - �- - N IELEC v T j BATH e4i;1i! — - A j� N f _ r s a4 _ q 7: _ ,t 17,411 I BATH - VL�� _ � 0 HALL 2 �?J T ELEV. LOBBY N I 'e, 5�- —�— 5� j , I �. KITCHEN t �I Ar _ — — T j -� —_ ....�T TII l J' i 145 YPE ( �' FOYER ;DEDF400MA MASTER T PL%ATOR 5 T BEDROOM ��a" t LIVING --- - �� 'i , — - — —+ - - - J ti✓ �. V ^!� i� I p T �. i'i 11 ,fi r'M ._i# i q „ , tt 0 11 , It t , u C,y :1. •'2 P. t 1i DR C I j I r �,' , �A LCON h IUP r _ �P - f _ I DN. J BAT A/ r,� 1 1--� --- tt - 3 t=IIL 4„ ' £ TIN• 6 n, �1 — - Y f I �' ,O• f _ _ - C y _ � I I { DINING BATH' - T E 1 JI BALCONY 2� - { N• B I 1 A I 0 v; 0 r7 �- 3 _ �- a r _ T STAIR N I STAIR N °�2 I -^ 1 - �n ------------- 111 K \ _ _ O T - - 3�� H L x ry 5 T r (1 �. Ho -- - (DRESS-GJ , W. I.C. _ 1 i — I _ - 777 ic BREAKFAST J C i �— DEN ' �; T� ' BEDROOM MASTERS — -j �v+ - i - _ �-- BEDROOM �0'? r-- s - - ' Yi2�-f1r17 10t14PAfiL'r N S1a oND Le-\4�L O4LY 0 20K r- n, T�-� i-7L All iOfZ ¢II'tISH �+FHepla L>;, 4 —_ I — t<E �H�r A-1'! --_ � I ` 1=0�c J7�Ji": �,GHEt7UL � ('� A 1 (� ( SCALE: 1/4O• =, 1• A) - �. ! V - " I�- Tar+ , raves - _ T L I— --- - 14- LEVELS 2` THRU 9 -4 TOWER N' 11' � { nr � �t I;f 1 �I r '� I`A l', B CONY .I i7. T LE -._ MATCH U RE11211 a ' : {r e v " t aq 1 v m w r — 2 17 A -I �OI- Q'I�NALF ova-��TN� I , . a - 1I BALL NY i I, `P�Lu�p,"+E�s BALCONY 3{ 011 Sc� n 16 F-x- M 13 1 I , 5-d �b-o 13-0 4n i ,{ 811 -A 1, ►S Ii ,..+6 t o 7 n II � , 19 , �0 2t p � .^ --•_.._� -� . I { n � 'Q 4 �' —_ i $I-2" T I�IiO., 10" Cl-1�" I'�' G _ (e; 2N—.a, I �, C7 T u --- H. on{.rL H -o- ,t �`= f 1 0 DINING- p MASTER _ _. s APT # DEN LIVING" I �� T - BEDROOM lI - ' — T J �7_-_ (, TYPE �'� F _T -� I - 1,7 ,._::.�.__. OC _ SINK QtAE l k c.' I APT. E _J LIVING .t} r —c I t; i KITCHEN I'I ROOM { �• � 4 4� - _ :_--- �- - i TYPE , , REF �4y T I (I�I TBATHI(DD --- II,� N•4 Co-5104 L'?-4 - - - 'a p o' HALL4iWI.0 ED :. - I _ e rr T t 0� �— lam_ DINING �C FOY R _T _- LIN 1 -- — - - -' 14%' �. �y II' `, _ -�: ►I Iaa�-4' �'_a'19 T �I i I 1 �I 44 �jt" {" la g': ; ;�! F' 2 ° rs' N U I -- W.I C. I - -� ' .- — - -- _ - ----t -- - I _ 41 ELECT `1 Ii ! - t N 3 � �-- { r° I I ( A � � � I 47 T77, �,—�14, 1�� , ,� H n` L.. ' 1 �i 1 a 7 .. I. � .r-G ..� '�- 1 $" -t � !l-�-j1A C — {{ r - BATH BATH r h, , 3 a - __... — ! fl, • H ALL - r . till - ....: k. T I I N T ti1 /={r„'. 1� •f IS�Y ..._,� T. , -✓ ;. �' r.',t.1fl. r.:.L.Ca, 77 T, I DRESSG LEV. LOBB Na' 2! KITCHEN =y ' -_ � _!� I T', IK111 i 0 k % REF. RANGE Q, _ G APT 117, FOYER 4° T Y P i MASTER BEDROOM BEDROOM E.E TORS _ : r!o tee- O 1�I I LIVING i y I n II { „ ' A '4„' I ". '... .; r .t' ,1 0 �.. 41 ��yti , ,{.. i h li p I, —` 4 4, i 12.2 4 IQ� A t { { T �, 2' pi.ylN i h a_ 4"° T4-l0?'_'� p 'v-d , Z 4rl T Ig• 2t1 ! {uy -- _ - { i "r pr— - 41 I UP ' DN DN I UP 27 TI �` ! j�� p L— � � o - I Ivry _J — ����• �-tE�T A- I'1 DFII r�i;4-7'1-r1 �I rt C%,I-/ DE rI LC;, . -- b" U1_en o. I"' ce 2'' r✓t.o �1, , — i S s BALCONY T a --- - - 6ALW IY I XT AT L--VriL 1 1�� 1 I .I -YP. FL. PLAN — 'SCALE: 1/4•• I°-0" .EVELS 2 THRU 9 ( TOWER N• 2) ST IR No } 1 , 31 T' C _ "t„ T I I L t Y r —_.. i� �A pig j µI i DINING _ j�,.�p BALCONY �l. STAIR N•4 y23 N•5j `-- r`I I .� (K , 25T f— A ', .. , xt� t x,i, ' '_'i u.,1 a 1tt 1( 2 4 H A L 1� jM..... f l'•d'. s i I .. _ai ~'1�r 1 III V I I { r -u' T Ikll �'!'�ik! '� 3 �i �, 4 - Gn II 1 n A M I ! W.I.C.►" Il I { v T _ ' ICI I �REAFAST �II MASTER (I _ BEDROOM I BEDROOM DEN (-3,-�T �!q I I ' - _ ,r4j t�- i r _ — - a11 Tt ==TK- _ , KITCHEN � p i i�� _4 iku; I dl tt•,�: (�4 I•�F — '--' r,c. r a 3 r o.I { �.d T j ---- - ' BALCONY I KV-- ----= 142 T t - S� Tara �I I� - _._= ... -._�,_,,,_,.,.._„�,,,,_ O — z � w o CE Q Q Y IL U Q Ir S !L Z0 Z Q J N ' o LL � N Z J UJ W w a>3 LLI O t` ,gr .� f f c 0 I - •Y.. r M:. . J''..: " r I•aP i *' n}'_"3 ?;yak . ' -idcA, •� �'`. n ,ems ` "$�,. ,itn ""e.^C" wv � .. r. v. '1 • }.. e �� ". s.. d ,..„fiK v c �� :vr iei� ."': `" "v Y. P`,5:$'W+A.. rat' k i. , f ^"t + R f 1>.>?','h :{.. :.:«^f, iMF `. ° ' ��' "•• t 4 ?.; v..N o S% .i yu tie _, k 2 f x�,p a �j� 4n in £ . .?F' ..3"• , .-,iL..E REVISIONS ' NO. DATA BY t, i F' ui y fY M +frses S .y. tur irararororrrmwSwC• c� W' f rFauz r rc � u r f II „ A SIDE • i � E � R 5 Q� .IA ,r Ana umaiuimadmA t , ,t 2 f N i �r 1 • ' '... } '. ..:. .' � k .,' " Fm .:. •. , , " . .r a. ,.. L. a .. ..,, + .... .. m , .. . .. f:, .r. t. r r, +'ww ... . N ,'7>r'N ,.. s '4•a ,.'s',.., ri ? 4+M..r .:. a ..Y ... € .n . ,Y ,.. ....... '... . ,; ..a. , ..:. i{ r , r '? .. .... :L J .. F i.. _....u. .n... ..rJ ,. J ,. •.. .. ..'.i .... ..... :: r r , rr :.:: a. r n. :,...> ..... n . � .. a t. �. < < .". ... f.,.-i .. .. ,..• f ., . a.,.,.. ., ..T , ._ .... u ..._. ,._ _. ..... r , v .. r. . •. a a ... .:i • u.., r' v... ✓v v . . • r. s E w #'l 6" q AN Sr 'Ak A g �'j Si __ nr 4 41, M,F' ,W � � '� �!, '' I 1� I " 77777' VR5-r,� Telt 77777 V, t -�'7°__ LK\ - i \ M- " P� ELEV. 2_ i �T a r. E; 0' ail BATH No-2 apts C & D ELEV. 6 ELEV. 7 1 1! r—I 1,7 TOAV EL -- - — r o o � �[ 'i1 i - I x I � UA _ ELEV.10 I II T BATH No.3 apt. B & E A - ir I _ nV � BATH No.I apt. C 8c D E LEV, 1 BATH No. 6 apt. H' a No7, apt I - o- -1 _ �.-o 17 LA �, ^owe L i t BATH No.4 apts B a E ELEV. 13 IVN 141 _ I •I � n r ELEV. 17, oo BATH No.5 aptsA& F GEK-Z e.- ELEV. 8 ELEV.,, 11 i 0 Mcp cac-•. " E L E V. ELEV. 14 ELEV. i15 �llr2�'a i ry �z j tzEp, r 1 ELEV.48 tJ ELEV.4_ ELEV. 9 r o E LE V, 12� ELEV//i9\ ELEV. 16., 1 ELEV.�20 ELEV. 5 �G�SS�D 0 0 �.h BATH No 5 apt. H ELEV. No 8 apt. I ELEV.A Q �i CMIRRaF2� 117 7-11 EIF Fol BATH NO 2 apt �G ELEV. o0 i _1 1"_�-- 1 _ ELE V.,2 BATH No. 6 aptsA & F BATH No. I apt. G similar YY��rr BATH No. II apt J �i r- — E LE V: 2�, ELEV. rLE, ELEV. 2 I i O �— n G r I O t _ � DO - � 1 7anrrrF�cli ¢• t-- WL I, KITCH EN PLAN -apt. C,D,H 81 I ELEV.\1 SC: 1/2"=1' 0" ELEV. I2\SC.:1/2"=1'-0" SCALE 1/4"=1'-0" a% I' h' 1 I� ,r r7 t7r - — -1-' Ff -_ - I R KITCHEN PLAN -'apt. BBrE_ ELEV.,'4'\sCl/ z'=1'-0" ; i Y r �• T�. ILD+ KITCHEN PLAN apt. A,F 8 G KITCHEN PLAN apt. J ELEV.5 SC.:1/2"=1'-0" L4' 1 LE V. \3'.sc.. 1/2"=1'-0,,. I ELEV . \8'\ sc. 1/2 "= 11-0° 1 x X X ELEV 6` SC : 1/2°=10" i �( fv Ft:�a s7Z.nrD�FD 1 G��t24c'.nt:~,-?',�?'.� ;�)<('1�=AL �L�GT, i2•f� T1'>�21 DPI -- L %a%( �tl�, �LGTf1)✓ ` %14 �/HAAf�G�C�?yr } G'�laD55I\V, 'jH^�t't�Taai MHO C wn aT �1 �(C t2 l U 2, 10 - � \V��IMGZ M�GH. II � 11 w�V CV\VIA\882DV M m &M INIM I � 1 IIII ® I '— — -fill M/�GHINE RM, R00E- �y�L 12 I Ir Er4-G�lAT'O R� v M.4Gt-+1ntc- Rct sYEL g- LVEEL. 2 UNC;l FL, ✓52L- 1 I \ 'PHIP5 LhpD�R ��" Oi "�TOFV�1 cdLL,4tZ 0-7- STAIR STsdtZ Op 74 -- —�--_ SECTION 2 TOWER 2 , SCALE Ve}" A•17 .LOWER I(mirror) --� Imagg ,^%L Uhl . P I P y RAN PRA. l L a0 N CONCRETE STAIR— TYPICAL DETAIL M SCALE: 1/2 It N 0 3T/rIR F,OX P,dlCTt- No, 4 rloNs I META- Cif �>Cr--t-D6r> IN PAGE 6LA5E> CAP SET IN GA1JLKIr-4 G rCOM6INATIdN ff,64N C.6r & Ve.ti1T 701- p� o1-IUT� - OP Fzc� SL68 /eL_ 1t� r) m �cn1C�i. �ou�MN >rE-=vfsL r r Lt=YEL 8 IL z m �I 4 tt LM1/�-=L 2 1=� �oUNao.TloN >��-,e.i Ls 6C- �2TE-UCTUKAI r TRASH CHUTE DETAIL TOWER Na 2 SECTION 3 TOWER No, I(mirimage) SCALE: Il4 A'I�O 51MILAR aT G2. FL>(�VEL 4.r v i om "r N I S H S C H E D U L E CEILING T ,� s CEILING CEILING ROOM FLOOR BASE WALL CEILING REMARKS No. R®OM FLOOR [BASE WALL_ CEILING REMARKS No. ROOM FLOOR BASE WALL CEILING HEIGHT REMARKS No. HEIGHT HEIGHT ~ .__ _. TYPICAL FLOO - LEVE S 2, HRU 9_ �?NT. i -._. GR�CIUN.D. LOOR- LEVEL I Y --_. �NTr. LO 7 �T�rzYTIL ��Ae2Yn rs r c pF n of �OYi=R C'�'F- �.-1 ��/OUiJ `(Y. L-':l�P .i7 Y j2�' S t:b:fi �I - O I I '" .r ;::A N N zn:r 2dv Lo8i3Y N Gr:t�T caEl II Tli rT sPlr. n i' d'-Pi I' iC Llvit l�o�M P'- I'' �� Sion cLaSi II /'- 1 r jb.IR T7' NON, r+L,1PGOl.r: 1=.XF. Ct%NG. P,L �F-r-49NCIM \/A NowW- -y ISH _. n - r LAUNDRY ARC �a �I NY L II II -T�_ G e - S� II- Sro�eciA� c1GTT II it'_.. " " �uMF'ooN( u u 14cx�c;. GL, VIr+7L coNc, a -� �- �:r I-t�.�1 rl � c.�a.,� �-o vzourio Tura nT�xT 1 K AST�rz Sizi7iGl'1 a i2 [ ` �iopi� -YF spy a TEXT st eai 15 f3A i t+leM ' G IC M l c G" G Gc VVUi-c t '>jF *•� i. I-.i< Y ON \tiR 31 ��T H�v�t � j' II II II Gr P-25 CYO mGY't�. DRE.. SII"Irk-1 GA�3-� -r' �/G C7 6f 1� •�,0,�2 'I. `�f't "ai=''f2A"! 1'-O° ,t. ��LK IN GL✓S i G�.6. F' .`i' wOO G7 T?z=�.a12 L7. TExTKai• n T `( /� �r-t II It a bBEro MEr I II p II �'-D� � vBALK IN GL II-� t3��t2M N' 2 T� G -L OAT M p II 7' n' a r M�SYCZ 6[ dM II 4 II - 1 !m^JC j`�rVai�u - u +Kr��T.SF'FL>Y dN.N�R �S -f,41_L 2 GLOSIEi GoRF"KsT \/Od G�YF C3dAL�CJ II 'I'-�' �� HAL A�F i' WOpD ' P �AE'b 71;; T �� �° d L�W,JIM It 3 }GITCH�1t �1 e II TSrI A/G, CL \iIN `l II U-I" 3 eLnsET I II �� Li SLUM.C.LAll j; ����fJ•� tl D'N II. II TzFzr.cMi`IT 15Fi — QJ�� LI�/INCt II II II b�l' T GLOSi II p If l-d / GYP8 �q 1� II1G7 r� I '}p T 3��aKAST \/IIFYL If 4 DII`tlr, GAr2�7 v✓oOi� I 1 1-1vii-i'l Il II II / J LIr1�tl GL q II It 4 KITGFiEN � � I r 1-r Ip �A?HrM TI'I 1c c,��s1MIG o'c� vN II mM Tex`7 d` w2 � e KITC-HEN VINYL- �I I t=�1 FxP�AY 7- O' �t2 i I3 �LGON i COj�fG. �TVGG4 TEXT Ga Tue./...eGvr.eo� �T,p �`, � LUM.GLc rl =rj I II I, � � tl ' I; `✓ i..�"I,1 hY1�Fz 'T cy. l.. I I; I T>=-M ��+Y � ell L � IL G � l INti I t G� G�.�r ..loon �w hoazr� �T; -ems. 4 1=� Y.EFZ C.T wooD GYP 21- cL VINYL �xPGonc. TroYEK 22 LAUt "r'�M II It II 'Tv:l `i4 LIVING 'GO`M II I I V. :i'- "; 4�a •� LIlNG6- "♦=Ou�rr.'1 C',At'." .:5`. II II I, G II t l c" j � ~ p c M1 h1T �µ — I L71 N-ING-t If- I , , 24 �� � 9� r y�lgirl-r L Tralwl pLurt G L 1 -0 L-Lr T tl l -o ?KllHieM -I' I c �4�IG c MfIr_ aelaab 1 4`� T �Al K ry E �J os t Gd T I I TAT •=PR T �f4 rG 'rrl �JII�YL /pia i�? 8p fis� <T = fi .Y WM.cLc. L 4L�lU r 12AGM V/I N` ' L II r 1 "® �--r II T xr Pea I "r t .TH N' I C� o.M Ic_ I� Tvq �G Q 11 =' GrYP 040^lI2,D ,fir LII'I�(i GL. II p �1 �vALK I C-L. �r GJ.OSET \/I(�ITL n II AExP.G"nr+c, �/ 7� rx�ES�l�ly �I II A II i `� q T t�Ur UONI I it 4 1 31 H.�L G 6T 1 u x �� �I p it �' :=IE=, I, 6C2 a `Mye 7r-xT -T ., MI .:. � o r`+ k1 er t ICY c,Gc R . �r }' f=✓OI'�I —0 — �s1�� CGNC SI.LC.K a{Pa;r� Cw.sJh1GYE:.P .. 5sa T H .a.i..L 11 p II . � ---X _,. pllylha GI�F.T" \\/OO.0 TJB Gal''. C�AA:D G?1'F'30,C.�C7 i'Exr,sr:t' QiLI" G Y f• SP , �� PUM '^s�a✓ITGH 4L1�X. .. EJ1IF::1+c P IP WZ-r — . N II -T ? SAT-H'N'� GF_F2+�11G �Y�yv(IG V-o r[W,AQG�V Tummy �ctYr� r:sn t I d 7- O LI\iING TAM U U it Ia2� T�rSF VA-LLT P - II III- Ir T taaLcoNY colic, — sTVG�v s -f�RRAcE S�POoM FINISH _ _ II 103� � '�'I'`� �N°� p — d n �j� Ir 59 •� >�n,L�cnN'�' II - It � .�C' I x Gr G.M 9N T ��'G L3ES?RM NT /L GpPET ��/o GY�13OaRD II �/ ��G SY?I N` ¢ NON GL If( cvNc_k3.�-r � — n it Vl 3� GLO�ET II II II 71-OII �G. STA11Z t° co`Jcz � — It II V rcl � MASTER g yf<� II tl G T.zE SSINc; II II— A-O \V�LK. I t G L It II b - I'I — �+ I3�TtiRM h®4 (�EC�pn(IG o.MIG o'c�,±N� `Rua G2G1P$o�D �I-OII * TEST 5r''nY oy c✓� c+t rP (3U — 4 GL�cT GLOrr�'T -\/INYL avr�dr� caYr?2�.dF�C> �r�;GOtyc, �-D G — 3jG 44 A�G cLaS T \/1rt L =�oNG. e III TYPICAL FLOORS LEVELS 2 THRU 9 ROOF LEVELS 1SZ � I I 4S L rVING7 RM G b.i�' q I2 TT.Y Lp•To� LdKst'( ll Ga=Fr c�rm7 GrYF ix�Mct3 fcxT�i�r j-� 145.•U I a/c izGbM G©NG, — €xPe:�k cXY �rJc, fi'- l'' G 4� 2 4 •= T,� � Iti°5 2r It` , _ MF'r^Lcx — II II �,a,A=1�S �1 DII`IING C4aP�i` \vooc ,Y? ua II 3 T STAia=� 2 � NON SiIPC — �PGU1G.rSG �F G, �A�I R STARt4'/L oµ,sLP�o�c, — it II `�� KITeHrr �IrrYL a 4 s 4 — R Sralc h+°3 unJ,SL�GGNc.. — `� L�LJrbRT taut n Till��iY Q�I-IP F' T�+�Ii CHUi� tcM" VM(L \✓IN'fl G; fi? {3GFa�D I �jI_,-it . C, So * LOLL cpT II It II }I-o° �° ToY r_6>cr.'r woos IIX`1 71-OII CT E3a-Tt1RM h" s G.a.NIIG c..F�.6.rtic �"o_ � Csaw T' I �G. G LOS'�`T �/ IN"'I L. ��00,T] Gr Y N �BJ�S.'L.iJ �"-�I`I c . � - TJ ra /✓z civr�� iP, rav �2� LII` 1' GL. GpriFET vOOb dwl, �AfQ> iky':SYRpt r �,,lLL GA lET' �I �I 1 s`�R�T 71-e�, DiZ SSINci n It q II 7_D to T !e O CEO, �:Ourl I -jpp- X � , + G1`+ crfF? �, jar•, 5% h�ALK IN GL_ GA.Z✓ET VvOlJe� ctir, rBoa CU x't.Si-�a::*�r` AJ- II 12 T GLQs i ! I t�mar✓I FII.1151-t 13 o I � �EVIF.NT 14 I S�iG pGiTGH Tt /-INYL a 7 Y II_on S � ��iNc II 4 71-ep r Ir- - �E i:JI.Jp �'• s�slric, II II II r 71-or' '� r�.LcoNY coNc'. — s-rucca� -j�xr:=�ea.Y �'_�) � T f3ATHizOOM N' i CSp� IG GMIG �d-o'c�e, ae�u�c� _p tl LIv/IN C G6. 'r �./Do n G Y1? ToL�YGT�. 11j� �'tl Gy �a� tSou (]IN 1N c. II ° L IN�I-I GL a II 2D T KITa t N �I N YL a TcY T �" 6r�G-I C-3ATi ti2M 1`t' 47 G 1� G f►MIc 7UZ*�'..�ouH� -rue'•',ly , B� cs-fP r LI IDS GLQS T II It TE�1 Sh�kAr 71-D'jQ� /L / , i-P LL c o>✓F'E-r \�oOb G7YF 1! ,all Te>er S'+ aY 'z� cl �2ol�M /I-YL II N �gOYi? GctTzi.f i?1.R61 jI�Du -pUNC7fZi GL a IIr caNc. 2`� LI ✓ING II - I- h " :•: _.. it 11 ,-.M INS ONWAMEMMM I DETAILS DOOR DETAILS (SEE DOOR SGHEDJULE WINDOW TYPES 8c PARTITION I 0 N SHEET A- 1`9) concrete O ; I OC) s crew° long ad atilnd head DETAILS lintel or slab c. IPscrews w/ dead rhields at 24" • ass, cont. caulking j 2"x I/8" galy, steel straps masonrywall " "` (tYP) anchors at 24 oc. s 5/8 ahestrock firecods 3 pipe sleeves per 16 gauge galy steel 2" S/8 Is gauge gaiv, steel amb (concrete wall) 2" 5/a as manuf. by "ALLIED as manuf. by "ALLIED i HEAD ■ °" I STEEL" or "KEWANEE" STEEL" or'KEWANEE" 1/2" z o - �,r..:: - tisx: ,_... k.:. `R�. :v. _ ■ ='eau " a 1. V4" removable insect screen n - -. trc: 1 E 1 • for 13/4 doors o 1. 1 ti .. r-: ° s ,, ,•p.., cum C a1 IfS � A 'I ~T" atlChof pet r—_ 1 � a a _C T � d 7/8"X 23/4" metal furrinq 5/8"or (/2" own board where amb masonry ,o _ g :E ekanntis 18 O.C. If occurs(w.p. where ceromif > / - mes occurs)- N aluminum louvers as 3 8 mti. at is .2 4 ac. concrete wail or ~ " asonry wall caulking for 1-3/8"doors \� 0 cont.caulkinq manufactured by TYPICAL FURRING DETAIL a !'m 1, — (typ.) Airolite (E type) 14 638 or 4 mtl stud where required SILL 3" sound att. blanket ETAL FRAME DETAIL METAL FRAME DETAIL IISTC 52 (USG folder 0 so-92:3-40 � 4-O l -2 Q-0 /� exp. con cor I" 4" M 12,3" long &.a.round head NR5 Ai stucco where it occurs screws w/.lead shields and masonry wall metal NOTE: see sheet A- for 1_V aluminum washer w/ neoprene 5 door stop typ. partitions details stud -I 45" gaskets �typ) jambs and tit wires typ. ms al furr. channels TYP. PARTITION BETWEEN as sills 18 o.c. _/7— ofPgyp.boord N OCCUPANCY AND CORRIDOR _ =— _N=E �OR OCCUPANCIES metal stud ii I\ �O O Jol yN t __y_ D E TAI L �, i SCALE. 3"=I'-0" -- -- _--- _- t \ A•1 412,3" long m round head screws � SECTION eL-B=1 folding � removable insect w/ lead shields 19, aluminum washer /adjustable p.t. wooddoor wall 3/4" metal furring , screen w/ neoprene gaskets (typ) Iambs 6 furring brackets channel a sills (18"o.cJ t.., :.-... WOOD FRAME DETAIL '> WOOD FRAME DETAIL 4 �-2 ¢_� AI oe- o Z. TYPICAL FURRING DETAIL WHERE OD store front 8 h where it occurs .— PIPES OR ELECTRICAL FIXTURES OCCURS - — (see tloor plan) N ID _ �•' - JAMB -- see fil lh alum. threshold as mallV8" 1/� 1/2"gypsum board panels ,' 35/8" mtl. studs�0 L_� a PLAN q,l� (where it occuursrs)) 24"_ �� schedule- by'PEMKO mod.*154 A �' CENTER MN cant caulking (typ) 3 STC 39�� FIXED ALUM. LOUVERS DETAILS DETAIL SCALE : 3"- It -0 - -alum. a temp. glass door pd> "�''` ' y''-, SCALE 3 1'-0" TYP PARTITION ' WITHIN OCCUPANCY _� sealant 1 I - 15 :- stucco where It occurs - � 10 — DETAIL'DETAIL' B - —r-- --_ --r— — . SCALE:3"■1=d v=Rr. n+uL�loN UP ro = ALUM. FRAME 'DE TA I L'0 D E TA I L''<o� SCALE: 3 =1'-0' ( ' ��� .Y� �• 2M•• i SLJSIr', GL�O, ocG IjIZS-. concrete �. ahtlt-< l a — steel runner e - 1/4" clear temp. glass caulking 6E I 1 gypsum coreboard H)=�D ~ N gyp• board a quarry file carpet i—J ,' SKIM -18 5/8" firscode gyp. board to occurs) each side of coreboord . I _ each side (when it _ ill I" core board ,I I/2 slope a 0 _ - _ FFL, 6 e 1-ly. 24 go. poE X x co-2 2 HRS- STC (WI bracing ongie o = -- m H vent duct SILL ' sliding glass door _ see mechanical- 2-1/4" typesal,; dwgs . for vent r- 3 Aid A'h screw 12 aa lihaft _ E dimensions i.SLIDING DOOR FRAME DETAILS kD �G JAMB TYP. VENT SHAFT STOREFRONT DETgI LS alum. threshold type 236-4A WALLS a as manuf.. by 'PEMKO' alum. threshold as monut. by sPEMKO' SCALE 3": 1'"0' laminating �_ 2V4' varies 2-1/4 137A ill AV. :button protection compound -- carpet ; 2 Hill see finish hollow mtl door u ~ = partition vinyl schedule 4 a D 1 types ;screws 12� - see det05 I�III IMR o.c at ..a..perimeter " - concrete 5-i/2" D GDN L GAJILK,� MUI.UdN-(NI-el�} DETAIL�� FULL SCALE U�� � TYP VENT SHAFT PLAN � DETAILS SCALE: 3"=1'-0° E DETAIL I� SECTION 1-1 D ETA fL filled y SCALE : I I/2 I' g r p 1 blanket w/ rout(t dd 3 sound atf. blanket to facing resiliently ottac�isd w%rc-1 -�- � channels ketween occupancies a public toilets marble threshold weather stripping see fin. schedule ��Il ceramic ���-- -- thresaluminumtoolswing hold-ce morl Is by"PEMKO"mod.139 iM LIZ 1 J 1 �oLMO 21. E 5-ff2'�— -3-5/8" - -- ._.�_'- NOTE: for in openning N " .. DETAIL(D-'CALE:3"=1'-0" DETAIL 12 FULL SCALE ,door$ aIt lum. threshold ri V2 sheetrock firecode so. side. PEMKO mod.110-A •. . ii/�j° *beat jack firecods S/8° gyp. panel gussets 1*44 mtI. studsa24"oe. Cl =y pocket gp. p0044s ea. sfds _ - ■ ( - door Ill " "/2-soclnd off. blanket r� a '^ — _ - [fL 'Des tY-420 - CS/8 mtI stuAspw Mt to (USG folders so-923-10) - G c. in two rows (UL DES u 412) }!#, .STC 1111111 _ I m, TYPtil o CHASE WALL 2 HR-STC 54 A G � �:T�►I L ;SCALE 3=1'-0,TYPPARTITIOIf - J WHERE 2 HRS. E ETAIL sc��"=1' oIlk WOOD FRAME 'DETAIL Mali a lg r IIIEV MUL IaN FIN,\ . , �HE(7t1t-EJ ---- .i , W .3 A cOi�t'uTc ? _. Its i ML SINGLE HUNG WINDOW DETAILS •'?� �y/cam may' IBOLI TYPE WIDTH HEIGHT THICK.I MATERIAL- FTY EE HNo.RTHRESHOLD REMARKS GROUND,. FLOOR —*LEVEL _ 2(3l ��� 7� III — 'fYMrltfl ; s D 3-0" la/9 NOY1wM(li — I%2 HR r-I6�f, R�4l2 "�"LAeEL 4wmN z 2 a /J G - I 2 Vf a , s' G i 2�-on,l t se �'-o" , �� �� I �4 v✓ooti sc. 2 — -14 GI11 AZ611 r , aD + 3 — x D 2'-2� 3 ®I2 fNI�LS Gr t 3-d' « !v'-�j:� .•iooD�'t 11 y 4 s'I #E fN>~rli,► - r '- II \✓ II 4 - r — 4"Ca/IP GVA'f5 r I -�-I, t--� _p -. III__ T 5 4{2�) -� j3/4 voob sc. 2 PIK6 Iev41W c VAr!7aV I 2 2'-(a � II D 3 11 _ � n I u -� 4 — C�-D� 4ep.N" (2-L 2 PA&xr°/l � � � �I.Or I i' .— '�Pa�l�� 4- G► � 2 Ps�.lk'l�i 01 r P> O — _ - I /!�r 3 r,l 2-COI - D 7 _ — 3-D— G��'-O" 4- i's1Nth _ 84_ — t4 P�1B�5 P�OV7 10 Z j j D �I_On �I-�bl' 13�' 'vooDsc. 2 ----+ — � 3�q. I-IiZ. '�I�► Ra�f�D "C� I�r4C�li 3 1 61 DOOR S(;HEDULE SYMBOL TYPE WIDTH HEIGHT THICK. MATERIAL FRAME IiTYPE No. No. THRESHOLD REMARKS _ — r ,_?' aF-71 r✓ i T Ci j? � � '�'�! �") Co-97° I �� ro✓naD SG.. 2 .___ 3� �-•< �IR� cuaf.><D rG" L�B�. c, I p 2'- q' 3 = - �� ca,„ - e * 11- co" to- 2 , . voo� sr-uW 9 — (s -o" 4 PAN Cly+(2'-� W O _ 4 OAN ro' G 7, 8,_ all ------- , -- O - -- n ■�A�OKOMom® irommommommmulma 11011oMINININEMMK%R NIB-Ammommo--IEUR_�®� VommmmommmO©m_�0� — -- -- - {3 494)&1-0 Co-�jl''��apDs.c. 2 %4 Nrz. �I� P,A�t'�DIG 1,ASE9i p cs , TYPICAL ` LEVELS 2_ THRU 9 TOWER I a 2 r i°s 11(2' (,')' ('04' 1 Y¢ He !%Iot� o^-rw yG� 1�r li 3 — v c, 7LColl (o S'2 ouvr, - ¢ (Ga-O" 4PANo-I- +(2Co'� 2 PA40ill; IT�I_ 'T IS tl I' It 2 — i 3/4-i"Z Olef,PAT1W'G kA" - ta 2 —¢NI 12ATfsD �L' �atG4- OP - I� 3 21 ---- q — 4- -- —- 4 c�r+�Yy a=r *&)IO° - ' �Co o°) 4 parl>cLS+(2 O 2 DANf�Ij *.4 004-L,4 ca 4 GAN C 1--4 c m m )OF LEVEL I I I 00 C� YPES I I O I He '1 C3'' I to lylHr p h C3'I p 2 to 8 1 I I I r I I He vioro o froD Ul - _ A B C i - I L_ G H No-f = ANC L D E F � H H i F saturated felt binder •3-O" TYPICAL Sx 6' ROOFWALK SLAB ROOFWALK DETAIL Ago ceramic granule surface weothercoating an saturated felt binder core of asphalt, plasticizer and Inert fillers• see typical roof section metal door w/ 3"x2-1/2"L aluminum threshold cop flashing extended under threshold \�M r 1/2 premolded ,�expansfon 'Joint filler 06 lightweight insulating concrete 0 structural cone. - o o slab r ROOF DETAIL SCALE: 3"=1'-0" A 20 I - 3 NOTE :Vent hole cut out after roofing is Installed, but prior to final roof coating PLAN 1.6 diam• LQ Mi alum vent cap t set in mastic) 5 course flashing system (see specs) rigid foam vent cant (fire retardant) r r= /oao_ insulating concrete A. . struct colic slab SECTION 1 cut 8-1/2% 8-1/2" w insulating plug. STACK VENT DETAIL A2C) SCALE: 1-1/2" = l'-O I B" Z x 3/1Y' — side rails '2"x brae 01 C 7/8.0 rung N nT FIN FLOOR fixed aluminum lad( ELEVATION- 1/2"=i-O' SECTION - V2"= I' o" TOP OF PARAPET WHERE IT OCCURS OR TOP OF ROOF log & shield ROOF ACCESS LADDER DETAIL A2 exposed cone. block or gqyyp boord on metal furring . wherr. t occurs struck joint ( typical) galy, steel dovetail [_ corrugate wall ties at 10" qc. galy. steel dovetail r—anchor slot stucco sealant NOTE typical for all vertical intersections of cone. eolums and masonry walls DETAI L A zo SCALE 1-1/2 "= 1' -0'. 18.. max. to front wall rnOX. Vertical iV rungs — Zx112" steel side rails — ?b�4 0min. - rung(typ ) lag bolt exp. shi 2-1/2" steel side rails Rung' 3/4 0 bars weld to side rails Ist Landing concrete wall m ; .:log bolt in ex p. shield ZX V2� beet bar weld to side rails web of steel beam thru bolt PLAN SECTION - scale: l-i/2"=1'0 bridge weld across top �3 Amin Pit Floor 18" max oa.width 12" min. o a. width ELEVATION -scale :V2"=l-e NOTES LADDER MUST RUN CONTINUOUS TO PIT FLOOR WITH EQUAL RUNG INCREMENTS FROM TOP TO BOTTOM LADDER MUST BE CONSTRUCTED TO WITHSTAND 200* AT ANY POINT LADDER REQUIRED WHERE PIT DEPTH IS3'0" OR GREATER. epa rotor earn PARTIAL SIDE ELEVATION FOR DUPLEX PIT LADDER scale : 1/ 2 = 1 -0 ELEVATOR'S PIT LADDER DETAILS @ 0 SHIP'S LADDER DETAIL D SCALE: 1/2"= I'-0" " e ELEVATION SCALE : V2"-I'-O" 3" aluminium post m n. ^/ epoxy non- shrinking DETAIL SCALE:3"-I'-Oe r DETAIL. D SCALE: 3*4-0" ALUM. RAILING DETAILGA j I ( y I '+ ► I + I ' N m - F a / - i I 1 Gb-1 L J Gt3-1 I Gis_, I Gt3-1 jj 60-1 I Ii4_ G&-1 1 G6-i G4.1 d�Ra-1 I G6-t -o I f39 3�_ 4Pc. L_I L_ _ _ _ �!� _ u4F>G. I _ L *PC. PC, { N ( °� Ip° I t a 24 Pc. i m p I 1 _ a I 0 } N i -'t t__-J L__!_J 1 - L- —.__L _ a__ I r�C, F'.!.� I. i pC I !_..-.—. F-.`._._ CONc. 5LA*6 REINF. 1 , ( J L-.J: 1--�E-Jl �-.. � + I I t W� Gk6 %10 `r^ WCi aVF2 I ' i , I I q,G. i q�%G. s'- 1 Q t 1 �1 QPG C .,�_ q s_g ,f " � ntL rlsn�,��:�, or+ wat.�. - / E�- _ _ _I _' _ .� r�L� r -1- Goo r - - - --}- cl,J -� - _ --- t / \ ___L- -J-- - - �_--_ _ __--___._. __ _. _� - _/__ �__...__ -. i$1 _. y _ ._._ T�11� __...--- _ _�1 - I- �- ems,}-� �� ( I , I Ll I I I - - - I _° sal' 1 f —t y+ 1 3Pc. --I- I__ _ _ _ -- L_ _ 1 �' L. _ J � _ _ _; �� — =p 6„ _ c ;FG. 22 PG. 4 P<_. 4FL, t 4 PG. 2,1 PG 3 Cs j - I ' co _tl I t _. 1 I ➢1 , �-- 4'- 3 It D t� r, 1-11-#- `�'-''--�`I- - - _ _ O J 1¢_ -;- - 3PGi 3' 1 0 i7-D t_� r 3 ? i 1- ` l- m tac PG,aISW f G• ��I PC. CID Go , ! C. SU?�Lj1 a:.' i .¢Pc. { 5 71 i /' 1 .. '_- 'i _� �{, "' n 1 25 PG, f _ _ -I_ -) I-- 25 Pc. _ _ -"` '2 J }�\ G 3 PC, -- J 1 _ �I I ... _ ( . - OI PC.- i I t_ _ --- 66-I - j C I J L I L_ 3 Pc. n 3 Pc Al8 9. � n C. — 1 s Qom. $„ _ -� Q 3 �C �� {" K a u o r- y it o -\ r -;- -, 2 1 ` 1 L T - � 3PC, „ 3p.., - -- Qc I ,� IF)c r l a Lp apc L —J L- --j L_�_� 4 : ��� Pc, Pc. 2 Pc I' - — - � - Q 0 , G6 1 _ ,CPC. i I PC. , � P , {I 3 P r , • 3 PG. " , f � �, 6u 113 Pe. 1 4,11 (1llllllllllllllMi SLAB ON F I LL 1- SLAb ON FI Zn bT 42' GANG. 2EIh1F02CF-D W/Corp-4°�td iVWM,t ON WL-LL CO"PACTEO FILL WtTR 2SOO PSM CONG- 2- FILL HATE.9-IAL TO ll CLEAN SAND 4 MOCIGA A+-10 SHALL oc 40PP6CIF-V TO 41.540 OF NRX. DC+J51-ry, IN Lir-T NOT EXree0tN4 1211 OePTM! ^( 3- POU2 $LAP, ON PA17F-f-N, HO PANEL EXCLCC Dtt44 > 2$F'r of LENGTH r OR GOo F'T o1= A2f.Ai ojj_ pt2aV.ot coNT2oL J°tN-'.S. TOWER No, i OWER 1\io n _ 4- ELf: VAT1oN TOP Or- GOVIC. 5LAZ TO 5E + 5- WAl cOLS, &SAMS, PENETCATtN6 5LAS ON FILL-, SHALL bL I5oLATD 6-( PRE Ill o011-4T FILLM I THtcv- U.O• H. Co ` SLAG ..+•JRLL• bbePouaeo over- LAKL e4F t'r- PLASTID "SRAMh'- GMIL VI1bIUFEI"1 09- S+HILAP,. FOUNDATION & GROUND FLOOR FRAMING PLAN. (ever- 1 -r- 6rzou�4o rLOO - It+--tv-CCI0V- PA2'TI'i'1ON A (>MA arNC., ON ThF_ 411 cdNC. -- -- SLIP ^"1 6 VL_ SHALL IaA /2 �C G:fIL DL T'a 1L�p "FL6KI 3LE I- ca FlE cTta To ANy CON(, GoLSt4r- t el wA.l A t+,rl4 x.4 c1. STIQv tsAKAL, SL F1 AT Lf.vE 1, `Z U�m W Z 1 1` Oui U) V U w ^" _ o :: • • CIO WF7 Q LL w UQ o\ U) C6 LO .__ ti 7 SHEET— O Li J i r ■ U 1- Z 0 0) u LO... w o .., U a� - 01 Q co C . C� w� Fw- �� U� o„ U� 0 U) Q 0 Lo U (D lz- ism L9 z o-SHEET mLO 0 :. f M C* A LG , T7�8'T4-YQ If'-4" `t 5 6 15'- O d _ pi _ _�—_ 3-G 4-4 or 13 14 I5 15.5 I6 4'-4" 3�-G t�6M8'-a° N _ 18 I9 rr I }-f -- - - CF I s 5 j j I r i ro - It 5W C° ?� 5TAfR- tnf 15-rAlR A j STAIR�ItnSTARaV! m EI II I- Nn A A x . — NOTE5 1 -SEA DWQ 5-5 FOR REDAR DETAIL' 'Z- 5EE OWG 5-2 FOR SECTION A-,Z . VETAIL. Ip-2 TYPICAL FLOOR FRAMING PLAN - tevels 5 to ScaLE _Z= f,_4"�F, a 3000 p52 �. solo, a r , 0 0 m �1 Gb N C P_E- "E WE. A t $CH E D V f_.E. MARK SIZE ELEV,TV REIt4FORG1N6 3 S.TImeOPS t1 O N. %>✓MA,P_K$ WIDTH DEPTH OFOtA NT o E. r10 SPACING EA. ENC> I o" - li, �b i7 2 C `I- �oC u_ --__ ° PR°vlpt< Wop1'L SLr3£V¢ N6AQ SW. AT 0h. MID -OEM Avv 1 ;TIRRoP re.R1'Z.. VA Ip - _ !c4'I- 6e6"--e12" 4"_ &C (o"- eE 2` 4TIES II o% -X 2 cAYE2 ADO 2. 6 bT n-o 1 EA Ft,c S LAYC.{L — ��• 2 ,5 $, Chu • GoNT. rttRv eb-lo 1 io 2�p 2u n q in --- -- •TNRu R4-12. 24 - 4- 2 o2111• + � . -rlkwv 9-6- IS - Ib 1 2 4-i:S ._� - IPA 24 5 -20 10 '.JO 2* LW& IDe Io' (Z� iC'� Aoo 2 5 AT h-D� t �5 h' -21 2 30 2µ� 2A. 4i3TtEs iio°% 01 2408 A7 HBO i MAiRA}cE -22 0 30 2N _� 2N #4T n dllo% Ap= z&6 Ar nortILA r,a -23 1 20 2$ y 3T+�sci l2'I% ?Q� jcs _ a1 `( Y(,. I4 c 5n- 12 a s, tc 2 LA If E25 - 1 n'� S1h1 IH I1..__ A� N'C�IN C.✓_ a' II is bTAllt ) TQR.n. LAHO+NG - „ p p - 2 PA ILWORI'L• 34E 6vt• NBRCL $.1I+/. AT f.•AK 1 P 620 A,.5s+2a.0 -S2> 1G 21& -� 12. 16 2 6 24 c Io+Io�c. _ 26- 1 -rH v Sr.,SaAA eaia " ��r, 245 r7- -- To r 2 J f I{OI5T iew m s w l 41 I CI NC, SLAG a �w 4RMT h STIII 6VAS. AS Pc 2 , ELEVATOR. NANVF. Q" CONC- 5uPFD W/ 4-ei2'' %. EA. W AY.-. J11-' I .el.44-olZ`.T('ASIDES � RR-Z�. To- to t � K11 _'AL �� i t3 e 1=I!5coNc. L� N � J S,#1 Jt4t1� 2" cc f5zw t-- FQgr!IxG AT Towtia- Ha 2 , SIn4Lg(Z, ReYgm.!�O) ELEVNIOP 'APtCHINE 200H FLOOR- 3 �t2AMir-d,c> PLA,N ..:..., ,. -.... — -jcj P e>_iq R[s- I q cs a t WOYE;T-V AN.N6 AT TOwE2 Na?., S 11•IILA tZ, R C- VS(vta0 E+LE`bIW7O` 1, +" ROB R00F .. PROW,- -6 1_ p O DETAIL —p N - RB- 2I : b- C -- a r c* �`C: _ NIV W I COOLING Tow sY I 6Locla WALL F" p -• e+ 2 el 4 +f A6 64TION X-6 -....... -.. _ .. .. ..... .... .. . C. 00L(N6, TOWED- 5UP90P'T r-lZA LING , 1, .1 - �) D E TA.I L fa - R�-23 r ce RBa-2'y L. CdOLING 'To wErz q, c-a pL AFd s = - t2oMl-AU j 'To P. thaT, hIo-DI I 4t4t sIZL' AS (yK Rw bart,5 DETAiL FS-� -.. CHEDULE & ROOF TOWER FRAMING PLANS A u 44 w 0 6' U, Z Q c�Qcr=a Q 0 co U Q W J � W Z 0 � O Q J H rn U. Z p d a a ui m di LL 4 ic REVISIONS OREDATE BY 1 r • )HEET —OF I _ c Oj, L u M N GRID LIN E-_— e QF) 10 Al ' ��..�.' �..4 � 1 r4i1e18 1? i 1 • r _ 1 I I , KI(3) (4) 03 r M N O w ( ? 4- ; s I b. 14 EL`- VATGW MACHINEROCY. WOOF t 1 ELEV. P AC H I NEE :_ 4 Lo!c� MAIN RQOF Jr 1 CO r tt1 `q `EVI EL O j1 LE` E L. S4; I i CL x , i i j [ I j i j , • I t f cV 1 Q[ LEVEL -_ _ } op tv Lli N Ui 1 t t(1 y h N 111 N t11 LID t 00 may, r 4n LEV E L to _ i d- f i 4 i r i j `i N 9 j t (C1 n ,1 I L9 to P I I x# I x#c x# Xi# c"li► ! c} N qr ( [ Ct 3 O �{ N '� N �i l9 J 00 1 1 I.EWE s r I t xit J a r�LA C4 � xt jr #, x ik x 1 j� td1 _ ( k�_.I I LE'✓LL4 ( sc�CY[N d _ i ;r 3 I o e_ aa� n 1 #^ { ! x x #t i �O) j tv xV Oo VC1 § vN 0 0 0 # �* N r, � xx zi #O 0 N O �NNt I, ���2 x I LE V L Z I j �✓ `� j f f ! CO110 X U X _ t� CL v ; f - ' � 9 `? f I <' s� x` I `*s vt + .9 . h ¢� .S 9 ! D L) 6 ei r ! ei e4 t� r* N x N.9�- f t t7 x h k x K > ° CJ i- h C X .T r t N N ai N t ra N o() x x O Z — , U <t U .} N �' rJ c� d' N '�' �•f •-j'. �'- �_ cy �t o d- N LEVEL } q O Cf N t .,6 TOP o F _-.s...a i,._,-_.,».R...,. V...i.. _,C..-_",u. r..a ,, __ _»...,_..._.,___'1.. ..... zs.-.,.,.r:. ,. s:..:i ..__.,_�-.".w...,.,-.c:.a..c......_-'.......&.... _:.�:..._s.: •.- .. __...a, .«. ._,.... .__,_.,. ,._. ,._..._..w ,. ..... .. ... _..,. ... ....... ...... ... .. ,.,._< ...,. ,.. _.. ,.... _ ... ,. _ __ ,. _...-..,.._ ,,... .. _. .. .-. _.,,_._,. ... .. ,__. TELEVATOR MACHINE Room RC)cF LEVEL 12 j ELEV.M.ACHtoa ROOM FLOOR LEVEL. 1 i MA N RCD F IC) r i i { s lqo LEVEL 'f ! i -h ' LIEW L r. r to LEVEL 4, I t LEVEL 3 # Q EVEL 2 GR.FL LEVEL T yam" <t c CO uw Z{y W ML rn U cr. 4+ • ` ! 00 cd r O __ - Y J w zi o J > q !r uj J uj uj y z Q l= u � v► 1 W � rJ REVISIONS NO. DATE BY -NOT ES ---- - t — SEE DWG., FOR COLUMN t�CTE5 2- SEE, pWQ. FOR ADDI"I"IONAL CO!. OF-TAJL. , / a — COLS. MARKED !Iv CCNC. 5HEAR WAL'- 5HAL1. HAVE. ��AaS LAPPED CLA55 O.`,E4 PLACINCt r, Di--rA'L IN DW _- G• 5-10 24" 4 H G VEVZ7.--- Sn 4d 1-:� VE't 'Y- .4-a.T,t'_S SEts sEGT1 bETA.k_ h1-;O �• om N-IO JOB NO. I,zuMtY, 4N'I VFaT # 3'itPS � 1zt'%, SHEET ■ ' _OF w: 2� q• l3�-n IS-0 2� I IbG loT x2� 14 1 Pix Z'�`_o 20� q uK11'�ALCE2NATL t4�iD P�X2$}m - I - L — L ltJ - (� {•L - --r I � F L• Fil a T L J Ii In f (" I r LU N jr _ f �� ,a rn L- J L J L I_l i i-3 GG 1,-G 6 6 T l 12g f- 0 IilK4�. CIO�a �' X.q 24 (mac. a bars 4.A a kFEE - r , L 1 J O _ mil _ ram_ Y l`• - 0 t 8 1+ -1 T ID fi y i _i m L _1 , 22 Pe- DEP-N 15G" n SW IA., PILE CAzP OF -TAIL 14. - II- o (sW �6 F. c. DETAIL S�nIL�z 2�v�ct as J } iny9p y i� � 6 f f } rt t ��� a A v C 5• SW G P ILE C.AP LDETAIL- 14n 1-o (gw`o PC, DEThiI 5%tljL-, L REVOR.feP) --- SEcTt®cam! A-E PILE GAP laEi5rktz.S ao/!_ 89irT £.w, t2°"L/ Ta P E.VJ am q�f4 ,. 1 0- ( 1 114 6152 I?; ..I:•f� }i} 2.IT� 3 1•i `�0 1 �' 0'C r ,F'3'. �yl a 0"i ' rQ� r i Or CI 1=J - _ " rl, T Ul I.J © �•� w7N� 0 i J Uen -.. _ 1 ti9 f 'Vf __ rl r.�. ' -,.G>' fl rl 'c•r 1." �,,,� rll .1 r � "G.1 �'� G.7 :iw �.�. t, LJ - .� L, N.. "1�J LJ m--••�—,..�:_. w• 15, DEPTH 22� DEPTH 24 DEPTH 24" I3EPTti 2$11 _ OE.PTH 54 DEPTH 341' E; * ro LONG WAY 3 P)AND5 OF 15*5 EACH WAY i5*6 EACH WAY � 10*8 LONG WAY, I4#co EACH WAY 4* 5 SHORT WAY -7 *5 EACH WAY ��ql��'i�� 15*5 15HORT WAY 2 PC 3 PC. 4 P. C. 5'P. C. Ga P. C. ? P. PILE GAP DETAILS �4-11 PILIt,S o' 40 704 PILE wsuW I � V: - r 4.. I DE PT Se 11' $ EACH WAY 9 P, C . GENERAL NOTES NOTES 1 - CONCRETE SHALL HAVE 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS UNLESS OTHERWISE NOTES 2 - ALL REINFORCING STEEL SHALL BE DEFORMED BARS, AND SHALL HAVE -A MINIMUM YIELD STRENGTH OF 60000 PSI GRADE 60 , AND MES'T ASTM A-615 SPECS �'3�_ ALL STRUCTURAL S'TEEC. SHALL HAVE A MINIMUM YIELD STRENGTH OF 360M PSI , AND MEET ASTM A-36 SPECS 4 - ALL DETAILING , FABRICATION AND PLACING OF REINFORCING BARS MUST FOLLOW THE ACI "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES " , U.O.N. 5 - CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE BEFORE STARTING WORK. DISCREPANCIES SHALL BE BROUGHT TO THE ATTE>NTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK 6 - STRUCTURAL DRAWINGS SHALL BE WORKED TOGETHER WITH ARCHTTECTURAL, A/C . ELECTRICAL AND MECHANICAL DWGS AND MECHANICAL DI TO LOCATE OPENINGS, DRAINS, SLEEVES, SLOPES, DEPRESSED SLABS, BOLTS, CURBS, ETC 7 - ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS " ACI - 301 SPIES " 8 - REMOVAL OF FORMWORK SHALL BE IN ACCORDANCE WITH ACI- 341 " RECOMMENDED PRACTICE FOR CONC. FORMWORK 9 - CONTRACTOR SHALL SUBMIT SHOP DWGS FOR ARCHITECT/ENGINEERS APPROVAL i` 10 - DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN REBARS SHOWN ON SECTIONS ARE FOR PLACEMENT DETAIL ONLY, SIZE AND AMOUNT OF REBARS AREAS PER SCHEDULES 12 - CONTRACTOR SHALL OBTAIN LATEST STET OF DWGSa INCLUDING ANY REVISIONS, BEFORE STARTING CONSTRUCTION NO CHANGES OR SUBSTITUTIONS SHALL BE MADE WITHOUT THE WRITTEN APROVAL OF THE ENGINEER 14 - THIS OFFICE DOES NOT ACCEI'T ANY RESPONSABILITY FOR THE INTERPRETATION OF 'THESE PLANS BY OTHERS, UNLESS REQ,UhSTED IN WRITING, AND IT TS GIVEN__THE AUTHORITY TO CHECK AND APPROVE SHOP DWGS , AND TO VERIFY _.�. F. .� , - -, •_.., _ DOWELS SAME NO. .,. o { - VISQRFEN NEHBAANe �p� ysZE AS GO G BARS !fie -,� ,. Q Ik•''' '�' .. Ex 1'C1-Ho P I LM SA RCS �-.......-.._ar,._... 3 I 14'" I��rO G b- Z s-, o Ic vIS9ulN u c iNly nitie P S1orN GAw t3E REINFORCING' MentuRAws { w �� pe-r µa, Iw mov, EI+ 1 M CLEAR COVhFI FOA REBARS TC B jr ^_- ZYpuXc&G� TU 12 PRov nC. - C E AS FOLLOWS1 ove`RPouR [xTe:Ho p��e p ._._' ' 1". COLUMNS - If" to tie FOOTINGS - 3" BEAMS - 1� d W -._ I, sHTo ab .�,� ^� L� W%TN Awy PIPE Oft y AI,g - 2 " to tie SLAB ON FILL - 2" from top SLABS - 1" { FrtENU PILS I -12AVe eFArl - � .. - - UWO R�ftOJNp GONSTRaC'tiaM LnNC, 1hro (,b over PILE C-0mC. PILE. tat. w I _ 1 phlE :Ap`: *s [L { t 2 _ALL REINFORCING SHPILL BE HELD SECURELY IN POSTTION WITH STANDARD ACCESOAIES. �2 f�•G.� - CO�IG. PILL LTSWO Pitt 2" 3 } T r — — — — B -SLAB REINFORCING SHOWN THUS 1 HTO PI4e GAP 4 - SPLICES 1TI CONT. TOP REBARS SHALL BE MADE AT MIDSFAN N SPLICES IN CONT. BOTTOM BARS SHALL BE OVER SUPPORTS 5 - SPLICES IN REINFORC:INC, WHERE PERMITTED, SHALL BE AS FOLLOWS; T f 0 N A- 9 S E C T 10 N 8 -9 T Y P t C A� L COLUMN PILE CAP D E TA t L COLUMN VERT. BARS - 30 BAR DIA. TEMPERATURE MAR - 12" MIN. SEC FOOTING DOWELS - .30 BAR DIA. t 8" WFi3.DID WIRE MESA •• 6" TE3NSION SPLICE - CLASS " C " ALL OTHERS - 30 BAR DIA. S E CT I ON C-9.AL COL. --- 14L 14.E pp EAR NON -t3EAaING ! — --- -' MLOGV- WALL ILI d1I 2M Stu O oI � vc0 < FP 6I — PG-..„ QA P aAe A 6A2 I DROP BEAM PILE TO TOP of P.G. DovJEL'S 7 L _ L GA.P Li PP-ovIDE DOWELS WHSR:M� GR.ADEE e>rPms DO MOT �L FQAMt INTO COLS. TY PI CAL 6v-ADE BEAM SUPPORT DETAIL DETAIL D-9 \ \ \T\ \,�\ Elm N, \ \ \1111 ,j / N — 212 CL, TYP. 5 CIAQE WIRE SPIRAL 2CL• CX SP: �— EGL. 5PACE5_TYR, _ CO sP-@ 3� CL. I TYPICAL PILE 1414p i 3 5PECIFICATION5 - PRE15TRE55ED CONIC, PILE -a�ol CONCRETE MINIMUM , C= 3000 p.51, AT RELEASE j f'C = 5000 R15•1. AT DRIVING " STEEL STRAND', UNCOATED 7- WIRE ASTM A-41G 597 5PIRAL BRICSHT HARD DRAWN WIRE 14x14 PILE l4xi4 PILE INITIAL P =14K/Peg STRAND (3®�) _ 10.9 K/Pee STRANDC�i6"�� MAX=50.0" MAX ,=50'-0', PRESTRESSED CONC. PILE DETAIL 1 - ALL PILES TO BE PRECAST PRE44TRINSM CONCRETE PIERS DRIVEN TO 14" PE.ES- 40 TON 12" PIL S- 25 TON 10" PILES- 2 - SEE SHEAR WALL NOTES FOR TENSION PILICS AT S.W. P.C. SPECS. 3 - SEE DWG. S- 9 FOR PILE CAP DETAILS 4 - CENTER LINE OF P.C. IS CENTER LINE Or COL. , UNLESS OTHERWISE NOTED S - WHERE GRADE BEAMS ARE SUPPORTER BY ONi PILE, EXTEND PILE CABLE 16" INTO BEAM , U.O.N. 6 - CONCRETE AT -PILE CARS, GRADE BEAMS, STRUCTURAL GROUND FLOOR SLAB TO HAVE 4-000 PSI COMP. STRENGTH 7 - PROVIDE ROUGH & CLEAN SURFACE BETWEEN TOP OF GRADE BEAM & STRUCTURAL GROUND FLOOR SLAB 8 - ELEVATION TOP OF FINISH GONG. SLAB SHOWN THUS �r j 19EEk` PILE NOTES 1 - PILES SHALL BE DRIVEN WITH A LIHX-BIELT 520 , OR 131?tIIJIR 2 - MINIMUM PILE LENGTH IN GROUND .FOR SHEAR WALE. PILES TO BE I5'.0" i FOR COL PIECES - 12'-0" 3- IF A PILE , IN A GROUP OF PILES BEGINS TO TIGHTEN -UP BECAUSE OF SOIL CONSOLIDATION, EACH PILE IN THE CLUSTU MUST BE DRIVEN TO WITHIN 2'--0" OF THE FIRST PILE IN THE GROUP, OR UNTIL A BLOW COUNT OF TWICE THE REWIRED BLOW COUNT IS REACHEID, WHICHEVER.CCIGS FIRST 4- IF A LOAD TEST PILE HAS BEEN MADE, THE FIRST P'n-1 IN ANY CLUSTER SHALL BE DRIVEN TO THE SAME DEPTH AS THAT OF THE LOAD TEST PILE, OR TO TWICE THE STANDARD BLOW COUNT, WHICHEVER COMES FIRST 5- IF JETTING IS USED, A MINIMUM OF 4--3" PENE'TRATION BY DRIVING IS REQUIRED FOR COLUMN FILES . AND A MINIMUM OF V-3" PENETRATION BY DRIVING IS REQUIRED FOR SHEAR WALL PILES 6- DRIVING OF ALL PILES & PILE LOG SHALL BE DONS UNDER THE SUPERVISION OF A TESTING LAB. , AND A FINAL CERTIFICATION REPORT SHALL BE SUBMITTED TO ARCHTTEICT, ENGINEER AND BUILDING DEPARTMENT CONCRETE 1 - ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI-301-72 SPECS. 2 - NO SLUMP OVER 5" SHALL BE PERMITTED FOR ANY STRUCTURAL CONCRETE 3 - MAXIMUM SIZE OF CONCRETE AGGREGATE = 3/4 " 4 - ALL SLABS , ON FILL OR STRUCTURAL , SHALL BE CURED FOR & DAYS 5 - NO WATER SHALL BE ADDED TO CONCRETE AT JOB SITE 6 - NO CONCRETE BATCH SHALL BE DEPOSIT IN FORMS AFTER THE MIXING TIME IS OVER 90 MINUTES 7 - REMOVAL OF FORMWORK SHALL BE IN ACCORDANCE WITH ACI-347-6.9 " RECOMMENDED PRACTICE FOR FORMWORK " 8 - IF PEA GRAVEL CONCRETE IS USED, CONCRETE STRENGTH SHALL BE INCiREASED BY 500 PSI OF THE SPECIFIED IN THESE DWGS. COLUMN NOTES ..,_ 1 - FOR COLUMN ORIENTATION SEE FRAMING PLANS ... 002 - USE #4 TINS IN ALL COLS. HAVING VERTICAL BARS AN11 OR LARGER , AND USE Ara TIES IN ALL COLS. HAVING ¢ #10 BARS OR SMALLER- USE M2 TIES AT CONC. TIE COLS. 3 - ALL TIES SPACED AT 12" e/c OR LEAST COLUMN DIMENSION , WHICHEVER IS SMALLER. 4 - OFFSET ALL COLS. VERTICAL BARS WHERE IN CONFLICT WITH BEAM BARS , SO THAT BEAM BARS CAN GO THRU IN THEIR PROPER POSITION 5 - FIG. DOWELS SAME SIZE AND NUMBER AS BARS OF COL. ABOVE. LAP FTG. DOWELS 30 BAR DIA. f 8" 18" MIN. `6 - COLUMN BARS SHALL. LAP 30 BAR DIA. , U.O.N. STELL PIPE OB TUBE COL. SHALL CONFORM WITH ASTM A-53 SPECS, GRADE "B" WELDED & SEAMLESS , Fy - 36000 PSI FILLED WITH CONCRETE , WITH J" DIA. PRESSURE RELIEF HOLES, AT TOP , BUT, & MID -HEIGHT. $ -ALL CONCRETE TIE COLS ( MARKED ) SHALL BE POURED Il DIjL RECT CONTACT WITH BLOCK BEARING WALL U.0-14 SECTI ONS, NOTES &-DETAILS E .. Rm . SEE SECTION FOtt NoRIZ. VerZT• Rill - I t2 FILLE2' dolt4T' LAP DOWELS IN SAME PLANE AS VERT. REINF. SHEAR WALL V u TOP RF-INF. —� ! q I cLA sS '- i'SPLI cf_- _- #41t loot as" DETAIL F-10 ,q1 4 s" 6_I ___.-__3 FIRS? TIE 15 3" OR MORE. FROM FLOOR Q4-1 CTYP) a OFFSET ('BARS — P ROVIOL GL6AC! Q :. ROUGH SURFACE SECTION 13-1 k SEE SEGTIO F02 NORIZ, VEQ-1. REINF.-- I21 F I LL11i JOINT — tsa, , LAP DOWELS IN SAME PLANE AS VEQT'ICPL QEINF, SHEA2 WALL_ .V s Yw-4 S ECT ION C-1 0 V >N w v � J V IZ F1LLM. lot ?jr_ SECT ION D-10 il]I 4-e-Iz" V. 6 A, - FACE - MAIN VERTICAL j ' �VEFz RE6AZ FIll 'T0P OF PC. To LEJEL r REINFORCINt4 FArE 51=E coL. Satt>douLE 4� IFS V A. N Fi a L-FVc-,. -6 To 20oF 3 EQ• SPACED eG"t2 T #2 HARPINS @ 24"% HORIZONTAL , MAXSPACING. VERTICAL 5PAcINC, EVER`( OTHER HORIZONTAL_ f$AR �TION c ' sow J I U *STIe5,5Ame] L42oe 1-1AgPIN5 (1 1211% --`v Ho�tzorr"iAL 2Et�Porz SPACING A5 HORIZ, SPACING. # 4as 01 `G C,,, rl 1=Ron LEVFI. 4 To RcoF MAIN HORIZONTAL VERTICAL 5pACING AS # , 121' a�G EA FACE FRort LFie, TO [ o BAR HORIZ, L'>AR5 TYPICAL e AT MAIN VERTICAL 5AR� �"5 % £A. FAcE Floes 'TOP of P.e. TO Lsvew 3 Min a 1 I 47 OR LARGER o m� r-DOWEL5 ), � _ Q Q OFFSET 1! G ALL Fi * 7 OR LARGER OFFSET SLOPE I10 m — ANY SIZE P>AR`o TO MAINTAIN 6EAM 13AR5 IN PROPER P0517I0N OFFSET POINT MAY 13E 5ELOW DF-AM DOTTOM COLUMNS 15AME COLUMNS DIFFERENT DIMEN51ON DIMENSION COLUMN SPLICE DETAIL COINC. COL. ( OR TIE'. COL) n $ BLOCK NON- BI'_AfZING WALL e U'V•o -- - ANCHOR SLOT W/ GA C.V. DOVETAIL/ Co2R VGATE0 A NCHORS , AT EVrR'J ; THIRD CoOrSE C^Z¢10/C) UP 1b LEVr-L 6 5ECOHO courage Ct r. % FROM LEVEL to TO 2OoF DETAIL L-CO qn } 4- (3A25 Qo E5 pS 8 bAIZs 10 e>ARb I TIE 1PE12SET 2TtEZ, PF-R 2TIE PER SET 2.TIe5 PER 5F-T SET TYPICAL COLUMN D E TA I L coL TIE. --;-4 'Z"x211 STIROFOArI �LOCI� 2-7g1� DIA. PLAIN $A25v „ o C2 r co u! Q f- 3 it ST (RD FoaN _ ' r Q NON- $TRVCTURAL N0N-OEARINC, TIE C.OL. - DLOcK 1� COL. CONSTRUCTION DET, DETAIL M-10 DETAIL T=( WRAP REll Z't#-7 t*, DIA. PLAIN WITH TAPE 7— TIyNT. 1'Z ST16'-OFOA►A COL, � [VON -ORE . NoN STRUCTURALvSHOWN THUS. 21x2 Si1ROFoAM� COL. 0 13C ocv - --A J- SECTION _- mM INTERh1.. LANDING #4e1Z„ KEY D E TA 1--C—R =-CD STAIR 5EAK A-f' INTERMEDIATE LANDING A6 poWELS a-- Q"key COL 1 I- o _ 2" SECTION P-10 13eIo J 10�� it 5 e 6" O STAIR$ AS SHOWN IS To ge USES Fog RP_f?aAk DETAILING ONLY. SEE 42cH. DW(as. Foo- DIMEN510NS 4 AvOIT• DETAILS 111•CE-CLM- LAHoigc #- � 4eli i� 3eiO11 � f� P(LOV1oc 1200611 E CLEAt,I SORFACE SHEA,e WALL SEE PLAt-t DETAIL K-10 see P!_AIV 1 I�t kk 5eC° • c SeO" G+ lol' u � u S �� 4 a C.Rovur; FL,O ?:>• LEveL I STAIR REINFORCING PLACING DIAGRAM SECT ION S & DETAILS ® i FLAT SLAB - SECTION A-11 SECTION F-II EXTEND BA2 INTO � 14 (_) OR 14 L 2 4 LZ o2 L3 SLAB IF CALLED I L WHICHEVER 156PEA7ER WHICNE R_ IS IN 6M. SCHEDUL 4 1 R CsREATEQ T12 �-3 0A —� `TOP BAR) ToP BA -TOP �% _ ¢A 4N 4 11„ DR2 'D BARS ' �p BA2S�� P�BARS IkOT2�lrlp, HK(G 8A2 I I I I I A 12 ( I I ( I ( I IZa 2rf PSTIRRUP 2 ,� ,A� BARS 61' MIN I�AI: BA2S I/� BAQS TIE 'F FIRST BOTTOM BAR LAP IF REq p) `BOTTOM BAR, tBOTTOM BAQ STVP.RUP gPAN L i 21'M Ax. SPAN LZ — SPAN L5 v o 1`(01_, BEAn)WALL I P I Lfr, FT61 P.C.) N 07 F. 5 w.OTH 1-WHEN C BARS ARE GALLED FOR AS COHTINUOu5,THCY SHALL BE7 BARS IA*D TO BE CO►rr. SPLICED IN THE HIDpLC_ THIRD OF THE SPAN • SPLIC6 BARS 30DIA ONLY IF SO CIaLLF,D IN 2- WHEN 'A OARS ARE CALLED Fog AS CoNTINUOuS I THEY SHALL BE THE BEAVA SCHEDULE BY. SPLICED OVER SUPPORTS . SPLICE BARS 30 DIA• _� A HFAvY QOT= o , 3- IGI eAQS 15. ovE2 RIGHT SUPPORT AS asAMS ARE CLBAD 1220M LEFT To RIGHT R WINDOW N@AD RovlDfi 2*S BEND BARS. 4- DROP N07ToM OF TtEBEAM TO TOP OF 0002 OP ADD 'ZN S. &wrrorI P.DDIT. 3A.QS C8" EA, SIDE OF OPRNI N6% [AT COQ.NER$ OF ALL- T•B. BEAM REINFORCI N;G PLACING DIAGRAM ,1 L LI L 12 1 LI MIN .301-k or L COL S? I P 14 L1 14 Ls col. "VIE P_L N. - COL• I 141Z sToe Sol or Tag EAL. TOP So. DF cOL. STRIP STOP So% oc STRIP BALS PARS Col. ST2tP ILS EH AIOR ToP COL, STR,P (TARS NOTE 3 ToP I COL• S1RtP 6A2S i Top COL- STRIP BARS Top MID SIRI9 BAPS ;TOP 111D. STRIA BARS I'ZLAP I 1- SEE R.t*.INFoRU HG STEEL GLANS Fog LAYERS D/RQcTIOY T• WHHKE A ISOTTON MAT R61N1; AAR.S. IS CALLED P1OPIC, LAP - - (SA Ry OVER GO LL, 3- TYPICAL FLa.T SLAB BA2 PLAC►N�:TAIL�-~ 8 ove - �s_� _..._ • a a tb_f GO L. Dowe LS ; 1121 TYP. /� �ou4LG T'IE� 6IRi11-2 SECT10N 'R-4 N•T,5, W®►D BOTTOM NIAT IZC 5 h,- DDITIONhI_ REBARS 9 4DoTTA /Z Z c W K 3 az ------------ Z p Q v 4 Ui PLACE 2 R'A4Ls (AODIT, RE KA-fLS) V d p' OVEIZ COL. ( PLACE 113Pr, IF: ONLY p 4 ,U ONLY I A.DDIT• GAtZ IS GALLen Po(z, TII�POR Q� F' CLA-all'f PURPOSES, ON Ly Q1r.3RRS�'III _ I,LQ i1 LIN ONE t0(FZE GTIOer 15 SMOwnI L J V, uj ul _j DETAIL N-il, 05E. LIN"CEL. WHERE. APPLIES LONG. LINTEL u 5 L �"x3 x14 x O'-lSg GALv. �� I W ITN 2-5g' 4P AN tN oR 60LT� �WE3-IT OR SIHILAR� �_._._. CONC. COL, a" 5LOCK BRG. WfILL fYPI(AIL CONCRETE LINTEL SUPPORT De"TNIL D ETA I L.------ RIi SrCON VARY POUR [— SEE PLAN r- gM4 co HT. 4YCoNC SLAB' Fz �-/C A 4. coI2 I ° DOWELSLi I CLIP L 4' $E ARtu6 —STEEL BEAM. 5EE dL EL EVVT0 R. MA NUF., Do d]i SECT 10N 3 i a� z a c cr_ v, Q C m W s ca W co `- � V a� N � rG WSJ 4 • 'o z > LU J K LL) �- Q Y 2 v c C-- =,a n o 0 Q lco to co i rrm P-1 1 4 w 0 J v z _J m _ T7 TRACT C I UNDER4ROUKJD DIESEL I FUEL WANK ---- " UNDERGROUND 011!S01L FUEL TANK .e01LWW BLDG.'`. --- �� o 4„ 1 {3es Awy 4•3 �p�Zec.loa ea �R` 1%01NChT1G. ryB Q' - Es SRN t1 o.R'� 2yq x 2�2' do S,6NVAf �a N, \� I 6," RL , I 3' SANIT42-( i PLUMBING !SITE PLAN SCALE: 1' : 30'-0' I LAKEVIEW i SOv� N CIRCLIE. PLUMBING LEGEND - ---- COLD WATER CW ,WATER CLOSET _.WC ---- SHOT WATER HW LAVATORY IL ----- HOT WATER CIRC., HWC URINAL. UR SANITARY DRAIN SAN BATHTUB BT ... VENT V SHOWER SH SAFEWASTE SW SERVICE SINK SS GATE VALVE GV WASHING MACHINEWM tCHECK..VALVE CV FLOOR DRAIN FD NON -SLAM CHECK NCV ELECTRIC WATER —— PLUG COCK PC COOLER EWC —01 FIRE SPKLR. HEAD WATER HEATER WH SLEEVE/GUIDE GU, CAST IRON CI —c-- .A.NCHOR AN VITRIFIED CLAY VC WATER HAMMER ARREST. WHA VACUUM BREAKER VB. FLEXIBLE CONN.. �, FC CORRIGATED - CMP L FIRE HOSE CABINET FHC METAL, PIPE --- SUPERVISED VALVE SV CATCH BASIN CB _ FLOW -SWITCH FS THEMOMETER TH FIRE HOSE VALVE FHV ACCESS PANEL AP HOSE BIBB/VACUUM BREAKER HB BACKWATER VALVEBWV -�G�-- GAS G VENT THRU ROOF V.TR —A--- •COMPRESSED AIR A DRAIN OR —LS-- L,AWN SPRINKLER LS MANHOLE.. MH AW=-,AC'ID WASTE AW' GAGE COCK GC ---AW—'GACID VENT AV EXTERIOR ECO F —F— -,FIRE PROTECTION CLEANOUT. —'CD-- CONDENSATE DRAIN CD FLOOR CLEANOUT FCO RL --RW— RAINWATER LEADER WALL CLEANOUT WCO :KITCHEN SINK KS PRESSURE GAGE PG FIXTURE UNIT FU THERMOMETER TW ROOF DRAIN RD WELL D R A I N S MARK TYPE. MATERIAL MODEL NO. MFG, FD-1 FLOOR DRAIN CAST IRON/NICKEL BRONZE TOP 30003. JOSAM FD-2 FLOOR DRAIN CAST IRON 32123 JOSAM AD-1 AREA DRAIN, CAST IRON 34424 JOSAM RD-1 ROOF DRAIN CAST IRON BODY & DOME 21000 JOSAM C L EA N 0 U T S MARK TYPE MATERIAL MODEL NO. MFG. FCO FLOOR CAST IRON BRONZE TOP 56000-14 JOSAM WCO WALL CAST IRON/STAINLESS STEEL COVER 58710 JOSAM ECO EXTERIOR ICAST IRON 58860 JOSAM W A T. E R H E A T E R S DEGIS GALLONS KW VOLTAGE WARRANTY MFG WH-1 40 4.5 208V 40 5 YEAR *KSK-040KK LOCHINVAR WH-2 120 208V-10 5 YEAR *ETK-120HH LOCHINVAR WH-3 20 1.5 208V-10 5 YEAR *JRJ-020E LOCHINVAR F I R E S P R I N K L E R S SYMBOL TYPE MODEL MFG REMARKS RECESSED PENDENT A CENTRAL CHROME PLATED —� —+•r SIDEWALL HF-17/32 CENTRAL CHROMEPLATE 15 EXTENDED_COVERAGE EXTEND *WITH BUILT-IN HEAT TRAP GENERAL NOTE THIS BUILDING IS TOTALLY SPRINKLERED. SPRINKLERS ARE SHOWN ON SOME DRAWINGS FOR COORDINATION PURPOSES AND OMITTED FOR C,IARITY ON OTHER DRAWINGS. THE CONTRACTOR SHALL SUBMIT DETAILED DI- MENSIONED SHOP DRAWINGS AND CALCULATIONS TO THE ENGINEER AND BUILDING DEPARTMENT FOR APPROVAL. THE FOLLOWING ROOMS ARE PROTECTED WITH SMOKE & HEAT DETECTORS AND ARE NOT TO 8E SPRINKLERED: MAIN SWITCH GEAR ROOM, PUMP ROOM, EMERGENCY GENERATOR ROOM, ELEVATOR MACHINE ROOM, AIR CONDITIONING ROOMS, METER ROOMS AND MAIN VAULT ROOM:4 ^' �L� l� i -w1.50 T_ DETAIL APT i li i APT © APT LIVING DENMASTER ROOM.IVINGI -DINKCILIVING MASTER DUN _. I LIVINCA °BL, SLA .' BEDROOryA - - -n - i � I I a Y ITGNEN n .' �{.LTCHEN - --- - E� - = Z -- A -CH Na OR ,� $. 4 7 -' J — 4 SAT lol DINING, kUfLL II CW I 2w Ti LL ] I ',._� ��� 1 'dLAUND :Y l _- } .� -_ M.A. CL. ; r� (/-DVNING - - -. - ve __ FOYER 1 20 _:_ "7 8 �' S RL J q" -� PO 5 34 /� �O DRY � � { l h ) ..___. _ -1 .... _ _ _. _ _ p J VZ '� �t �_ •._I' _- 50AKAGE PIT '� - - 4'' 5EE DETAIL �- .-. ' - - - _ -._ :-�� w 1 �. ( i. /' q j _ I}--- 11w. — — < I~ ' d 5 22 --- - - 'BATH Iro9 - > i� ---------- -,1- ` -- CC HIGH. Z6RiTi - : _. _. _ 4" 5 I{ C �., ,�„ E v �.._ rI TC>OEIflc. . HL R - -- 7J 13 -- --- -- i; E LIP ; - -- CiATN o SST . MIQK J w N u n BAZN. 8 1 -Bet P T PIT , KITCHEN d $w �. V.FL.- G7 q - 4 4'I e ��i 2 --YI1�N 7- NE ,Jq+ 5EE ACHE II - _ U TLHEN L F.EXT. _—J i Lam- I i --- _ -ELEV• BUMv W LEV. SUMP - - _- - APT O , (po PUMP SEE DJTAI I ENTRAAIGB.L_OBBV Nw.l - ENTRAUCE LOW(No2 DETAI SEE iI FOYER E IL._ I - �- Fsv 2�ppRAIN ISER RAL �.�' _"aR.. -� -- - i ((�A57FK F1RYc. O! ' I-L.IVINCj-.::..- - .� E 2'DRAIN-LING 'It gE6iFi53M _BEDROOM Sl..... _ FSP 1 N- - - - -- -- A DiN1N I `FIRE s , — -- 1 • _ 3" IRE SPR ME DE E PIT 41' RL 5 u'�V _ j." - --.._.., .-•: - " _ - 3�' 6 ?.., �- __. .....___ I 1 SEE DETAIL _ '� r - = co - _ 1 t 50AKACgE PIT DINING C } -•l I qu i 10�..1 �I y �.�� I _ i ROOM. 'SEE DETAIL u f G'11K' / K .. .. WPI :.STAIR WI STAIR'°L - __._._ .. , ,- _ _- SEFM-W,3 STAIR N-4 s o I BED I '.'_- - -__- _ - - }. - - __ A No l , 3" FD-2 ^.T._-r-._.- FD-2- i - _ IBA NN"Z - 5_ II 5/4. IA. O/va WITH lo'.HOSO —V _-- - ___ _J - i 1 ' / �' L�.:. ✓7V ! - BELOW CiRADE F 1fN.OF 645E ITH r lD ATL1 i QF,_---� B �. �L _ QISW)_._ _ ' - I __ - ' - _ - /C 7-1 - FOR GONT. 5EE 51TE+._P4AN -_ --(COOLING TOWER - _ b :. -.. - - ---_. -. .. _. - '. Y Ant s I oA T K .. _.-_ c� 1 I. FIRE Ex T• i • 'J. I ,V I-. I L (FIR2 EXT. _ ,I - 1-___ _ 29 3 - Ems PUMP RODM CO.QLINOITOWL*R - / naY TRANSF. VAULT H FDENBEDROOM PUMP M F RE PUMPLFOR ELFcLGRourlD - / �, _ I 5w1TCH 4.Eu.R ti M --- --- ---- -- - �. .KITCHEN I 'i: ___- • .:.i..:u - FIRE E%T• �I� I i V401USE PUMPS- O GRADE F 7 —F - F CHECK vnwE 4'' I 33 O 1 IN VALVE 80)( pll 6J v -To sIAMESE FIRE.DEPT CONN• SEE - - NOT E LOCATIONS OF SOAKAGE PITS ARE APPROXIMATE L.0-I NTE PITS IN Ca RASSED AREAS GLHASZ OF _. FOOTINLIS, WALKS AND MAIN - GROUND FLOOR LEVEL ( SCALE I/8"=1'-0" ENrPANLHS ,I 8 N "... 7 ...._.,vim i � ._ Lf°' '"1® .. �,. � .,,a ,< . � ,:,r , : .__ . ,... t "m l i BEDROOM ,i 3�,I- BL. LA5 S�---- - - ------ �� i C, 0 LE j I j x i y r. 1 i KITCyNt —_- — - _ LIVING �4' ROOM — -- I BATH HALL DRESS' N• 3 i f AUN 7- ,LINEN � . ; + - o' DINING �:__ r { /�_ I FOYER --1 F i 4 Ii FOYER _ I I �! - - R� _/ _ r :; — _ -- — -- - I.C. i N• ELECT -- t ° , 1 cl ' E L - ! i _... SOAIGAcaE PIT n p C- L `_.__., �L. I __ SEI: DETAIL 4' A r 3' 4 f'"-'" - - 4' I= I B Tr a- - H I r — A i -- -- ---------- - ii — - s t 5" 5J111° j TERRACE I HluN EN oNr. UP-FIErm KITCHEN ( T-- St . F�. S" 4 4, o j I � ; I ELEV. LOBBY N•I .... ' INEN J O t i L I — — -- — I / - >m A ENTRANCE ELEVATORS i FOYER HAL LOBBY Nei <i ELE'.V. SUMP PUMP I R ( ( �S'E: DETAIL. Fs � I - - LIVING "! I H MASTER C ° W I I — —F BEDROOM j 41� I , -,2,'. DRAIN LI�� ` i D 1 LAUNDRY 1 • SOAKA4E FhT �dn.RL 5„--- q f�SS _GE TAIL, �_ � •a N RIBAGE it C " — -- -- 4 _ N, --h- , --_ i FD STAIR - .-- hIR N• I STAIR N• a I W17H Wt 105E of BREAKFA 1 F { - - - - -FIRE EXT GROUND FLOOR TOWER # 1 � I '' / I� I�ISCALE 1/4" V-0 C DEN CL. `BEDROOM ! I' OM COOLINCa TOWER MAKE - UP PUMP • 00, , D 2 -- - i HOUSE. PUI-APS k •�i I ' cL. ! I I I- I KITCHEN - — - - - -- -- _ _ - - -- --- --- --- - i�; 0, Q Ile ---WATTS No. q00 .. > S�'IGFLOW PREV6NT0R FOR SRRCa,ATION SYSTEM - - 1 TERRACE Ptr IS' f TERRACE-� qg rxmtyz xx s . pw § mx^t \ TRANSF. WITCH tMERG. GENER. a GROUND FLOOR TOWER2 REFER TO DWG 'P-2. VAULT EAR PUMP ROOM C SCALE 1/4 = V-0" 1 , r F - TO PtRls FEP'f GOIJW, -owl 'b1TE' 1W1.-AN% -- V r-I,AE.GK VALVE IN V AL.v 0 p..agX SOQKAy6 PIT_. $ems Pvr RUN M A K \ K} 110 AM u I LIVING ROOM 1 I DEN. MASTER I I BEDROOM APT BO TO CC HPIZESSIOQ TA1.11C I' I ( �s & G #5 DUAL UV7 'I t , 1 I I WATTS 90 ``TO SYSTEM llllll pREVE TE2 BATH NO. If��� .L =1 {-L= DR ESS' G HIAL L < < W. I- C I MAKE-UP DETAIL q , DINING © i - r I FCC( F --��- 3 4 CAPPED NO SCALE II v -lL.� I g_I oR ELgtT� I �__ ,;ROUND I FOYER zsue p _ GOND. W i A V. iif - - o -� 1 BATH N0.2. r ELECT. CLO. t� l _� ry .. V I KITCHEN / _ 21/a'; D - - :. - \_ GN. - -- I ELEV. KS - 1 / I i , - AL UNIT ABOVE If , i ii, V. LOBBY NO.I °/w I F BACONY I I I I r O� 2�/2 NIGit Zo'NE FEED cJ 'If (n�rrT�l ._ ELEV�NQ. INQ. I 'i ELEV. NO. 2 - - - H16AH LONE HEADEIq,� 13RD FL. GEIL, ONLY(=.�,,,.+-<y.--.---- •_ li., I LIVING ROOM FOYER ' F ; 1 W/MjS(AIR NO' J Fs STF IR NCB - -�� TRASH GAUTE 1. ' _'YBorrpm _ _ FLRS APT A . RIseR -.r Tot' EL ONL I < > WASH I GOLD 4"RL__ O 24X8 DUCT GOND,W. YJG 1 k - moo'_ oc,- wc- 1 B_I i j I APT CO LIVING ROOM DEN. 'KITCHEN I LD PLUMBING TIGHT TO — - — ILING TAB TYP. I I AG UN1 ABOVE i- - I ,w'M R- ' .. a lit W.I.C. o GOND. W- I tZ \c' r DliGT ZDX -BATH �T_ --- � BATH N , I • in I HALL p - T —_ - C, W.J.C. . 1 iSzRUNPIWING UNDER C-1RpVND TO ?UtAP ROOM (6`( AC COI FOR CONT, SEE 5117E PLAN A_A.v .. - I I -SEh DETAIL "THIS. KITCHEN 4i ?- _ _"- •__ IV N>!/ - NOTE I II� —• - I + - HOT COLD WATER SHALL BE HELD ' . T146 HT TO CEILING LA , FS IRE PRINKLER " " PIPINCq 5HAL'L Be RUN UNDER DUGTWOtZK HOLD PLUMBNG YIGHT TO LEILI9(::7 5LAla CTYP.) _ BEDROOM MASTER BEDROOM - DEN FLOOR _PLAN TOWER 1 r ( SCALE 1/4'„1'-0' — ' _ Li KS-1. -- - -1 -- O O —_I I BALCONY M ..SHEET - V ' 7Q) BOILER - c3}laP. Rf! IQN TANK I g' i BOILER ROOM SCALE 1/4"-1'-O I MATCH LINE !' .SEE SITE PLAN t F`VF f u Y. .:n n:, IVa �. � • �i ry •y. 5. �.. € ,.r ., C _5 A I u.. a aw �...� .. .r. �.n ., .'•:� .�"`�,�..., ..�_.+ .. v. .,a.,. o ,w �d1. e ,...... , �u,,.e ... '�kc a . .7w ..� ,. .:.. ..>w... ..,... ,.... ..: �.;. , . . � �y[ivrrv. .,, �..... �a -.. ,rea..� .. .. „*,C? 4 ` .— ,.g,.. ; -. .:W •� 4����: a" b ry iF%. a a.. 1. Y. :a .u..... n.v .... q Y. .. r '�• A4 IK.r: - 'A' �. 4.. �� 1 � e.i.:•.iY.aR �" .x. %µme :QV.I. n� t.4,yY�F:L.X'uE:,n ', ✓.4..1:P�h..-.. .n....�.+ri�{....��,:..� r i ... .. d.. • Si. iid .I<:.v. ,.. .- €xn6 ,:- ._. _......... ........ {w. tixz...�r. �. ,.- ".4r. »F.a'm; �s z-i'•„r. � ,'-: r, r : .. ., .. T BALCONY •3 , DEN APT �D MASTER APT. E� ` BEDROOM LIVING ROOM DEN i LIVING ROOM --� _ J 1.� I I I i KITCHEN BATH 4 HOLD PLUMBUWGi T1C14HT To 3 D R ESS G NO HALL . 4 j ` _- �' I I I GEILINCi 3L A6 al - — - WC -I � _ W. I. C W/M ABOVE J ! I. f I o 0 � - I FOYER :- - _4°RL Q t W4 CAPPED ��-- DINING o W. I. C_ o {1 FOR E%LECTs-ID Q — rAR rOND• W. — 1! FOYER --- - - W GUN). ._ ' � 6T;1 j' r+- - - - I ( - F�ri f c Br pI iELECT. CLO,I - HALL 1 ap _ — of - — KITCHEN (H,fCaH ZONE L 1 e-1 O ATH N 0.2 i-- 2,• -- 21 O -= --j Ks-1 - E LEV. LOB13Y NO.2 UNIT ggovE I __ _1 I -- � D R ESS G _AC u �`NO. � I � , jI -- . i I I t ��. F 1. y-`—COOLING TOWER I� I - I "� MAKE -UP ZONE - O FEED r- ��i t ' F. EX7. -- ---- I � I FOYER I ELEV. N0. 3 EI-EV. NO.4 -. HIGHzoNeHF-ADER _ SRO FL. CEIL. ONL--( t� ' MASTER BEDROOM BEDROOM i ST. IR NO 3 t FSP C-TAIR NO 4 I i 1i APT. FL, LIVING ROOM i BALCONY ffI TOP SOTO FLRS ' CtoP �4'I TR}3 c - ONLY A? I H AQ Te wsea O - !' 4t, R I _ I Awl , r-r--- --- -- — _ OLQ W -Z xGONDET 1 � — — 1 tl + BACONY — - - ! pp -- T - a- I wc- _ _ BATH DINJNG a BATH N0.5 I la , �Iw LAlcT. HALL NOTE: HOT E' GOLD WATER SHALL Ze HELD TIGHT TO GEILIKIG SLAB. 1=1RF- SPRINKLER PIPINCq SHALL HE RUN UNOER DUG"fWORK - ' FLOOR PLAN TOWER #2 SCALE 1/4'ci°-O VAT ' HOLD PLUM61Ncq II TIGHT To CEILING I. KITCHEN (: SLAG (TNP.) MASTER BEDROOM BEDROOM DEN , K5-1 I t L i, (L I u I u KS-f DEW r 4" V-T VZ I \� i` J1� 5" v ftz _ J,,d"VTR ate 4" 4-M O 33 CD4ICJ CEO O�c1 OCR ZIFU lo3FU lwFU qPU 3toFzU 2 FU I a SANITARY RISER NO SCALE " J " I B-i f VC -I ear 8rnF L I r" I 7T"FL. r I I 6T"F L. t- I 5 T" F L . I f 4TH FL. y i I 3"" F L . - I" if I � i I f 3" JND F L. 0003„ ,-�,r J � L-I � �-i �_ Y- wco I we-i I`T FL. t4t 7 �' 8� 25 1 l 12 y 24 tE�4rw iF;Fu a tv -� l 0 DOMESTIC WATER SYSTEM DIAGRAM NO SCALE ol i / S/4u i I 3/4 _ L_I a a Il2,l c.owlo. ORAtN. GOLD WATER SOFT COPPER TO REF. AN -"'"-'SYPHON DEVtC.E 3/4 AWE T4P R'rLll`F ow \l. HEATER PAN.,,. 3/a W �� �iJ2 • WAA RE-L IEF R1--�ER \ S/A`1 DOMESTIC WATER ISOMETRIC APTS 'A, F, & G' NO SCALE j Po Ft REf^. , r- ANTI - SYPHON 1GE ])/YV. V % wr V4-1 m Vo 5OFT GUPpEF; FOR �- Qw ,_ ' - 'A„ �T 1 / v ` ANT%- SYPHON OEVI6 HEAT TRAP Vy 75Ar Ae*A$ T4P ct_AV- META PAI.1 Ile HEAT TFLAP 5/4 V U A.'*ME TeP PEUEF wvi"I ? p _, G,L.Av. ML-PA.L. Pam.► �-� R�LtEF R15ER 'u coL-P. WATER RisFR GQhiP>=NSATE 4Z1'-7ER ¢jELIEI� FZ\S�iZ 1/'Z' WIM 7 IR5EP. DOMESTIC WATER ISOMETRIC A `� Coto wATEr R%seR. NO SCALE Ct?Ni:>1'�N�'ATE RtsEFZ DOMESTIC WATER ISOMETRIC APTS NO SCALE PTS'By &E' m 1 t l' w Q W'¢ Z Y Q U u) Q OC O = U t1n Q w F Q U V F- � H w q w ON REVISIONS 0. DATE TBY JOB NO. SHEET P_ o Ii_OF ._ a: t; .n �..": ,,..�� f,6w-,rks...... ; ..:,#.._} ,. � .:F ,, -. >�`. % :...,. ,. :, r� i.._,...~ ^,.•. .. a .: . , a ... E. , ..,,...,...<�. ,: .Tr . ,•:- .... ,.. .. �u.. ,..- .. i7, .- ... .:. mo , +_.:. ad. .an a .. v„ .,. >. _._..�. , ,s..K�'. �. ,. .x ,.. ..• q �. ..f,,. . .., ,. � a ..{ ,.a,. �. .. ,, i * G ,., ,. ,« ✓'. .. ,n .:. t �.. n: • . _�.. � ssaF� �.7' '�•, mi• ++. �.li;�i ,mrv+.., �„x, s ",.tC„ _ - . , >i+:• < , =. ra ,h3 ,rv�; PUMPS -- SEAT Or K vALVE� /j JEN T FIN G eADE (..OVER SECURED , STAINLESS STEEL COVER' ` I USFGi 'To R� ST WITH SCREWS SCREWED TO THREADED _ r - "(21ZA► >,rSFR , u THREADED C.O. PLUG C.O. PLUG 4T G- LA,-,s ADJUSTABLE COLLAR a �t-fs-yS W lq�.Tw VAIN II THREADED C.O. PLUG FACE OF WALL GONGR.ETE Go�EtL GRADE FIN. FL.O R ♦o; ,+1.;. .1` J I - - - 4' STAN'OR1'1?C _ _____ _ .l -- —'- - `.1 GaNt?ENSATE 4exCONC. iJOTE:-THIS )S REQUIRE.D AT b�?° by PAD FLUSH IN/FIN. GRADE I SLIP JOINT -- a�� sPRu.ICLeK caN- ___ -tactTloNy _ I RC. co 0 o G 0 C ?ELIEF { - - :EDUCER b d, oo(, � GI(ZA�eL Y I?' GAGES p0 •� � w/c,C.� 0 -zoo:* 00 � b EXTERIOR -T`fPE FLOOR WALL I 0 0 ECCEF ITRIC - o O co O REDUCER p N �.N F�'� f b � ° a ° O �►�� ��� �.i - TYPICAL CLEANOUT DETA ILS fl I FIRE PUMP DETAIL NOT TO SCALE NO SCALE SOAKAGE PIT DETAIL 44 CONCRETE VALVE 60X TYPICAL INSPECTORS` EST NOT TO SCALE W/FINISH GRADE FLUSH PROVIDE TRAFFIC COVER IF UIUDER •PAVIIJG. TRAFFIC COVER W NOT TO SCALE / GRADE U.S. FDRY #2 SNORT VALVE BCVC IIII- IIII P IIII=I I LEVEL COWTIZOL=IIIIIA-4 11�2" To 4" FROM VAULT DRAW � VFQT �oSpM t2��2 AccEsS IIII=. _IIII- �ove�L 58�-�0 IU= Auk oup. -4 Skaygx�y� carxln�.. 1�2 LNSIve ���. 1,to i2P ,,S �1.4 2Ggv _ i 604�L /��i wblc, SEAL. OPEWIFJG e= t1 Lei M AT 61 E-I1iv PRECA57 SEPTIC I I<UEL PIPE - BLACK IRO1.1 TAIJIC OIL LEVEL I TAAIYJK ESAGKWATER VALVE e ' SEE PLt,,M FOR CAPACITY)I _ 11 TL9T VALVE I I - I = {III 0 z,. QuMIQ coNTRoa_LE'D Y OIL TRAUSFER PUMP - _ N f�f ZIONTf2ol-LER W ITa _ FCLR i I sLOPe 111 rj oN , 0IMF SELELTOQ _ . CHECK VALVE INLET 1I11r IT= F.O.S � _ I GATE VALVE I STRAIIJER ={III-IIII -III III- OUTLET-rLs%7-CMN1T4. I�{ I GATE VALVE IIII TO EUGI►JE AULT DRAIN SUMP VACUUM -r _ AUGE -_ RELIEF G FLOW �" N) L� iloN wL�TE2 VALVE '2HAIJD PUMP C? —►- `pc �� FILL BOTTOM OF VALVE NO SCALE 0 0 0 . PIT W/ PEA GRAVEL GUY GRAY UNIT 0BED- L TALK - j �p o •a 200 W/4"DEEP BOX FOR �� • o . °o 000° METAL 5TUD WALL FUEL OIL PIPING SCHEMATIC NOTES: NO SCALE BACKWATER VALVE DETAIL 30 Amp DR1?ER OUTLET kiI�c.W. H05E (� COQIJECTION5 I. DAY TAIJK I EMERGF-QCY GENERATOR FUEL PUMP) FLEX, NOT TO SCALE ` COOLING TOW MAKEUP PUMP W/ VACUUI�1 BREAKEk5 FUEL cowuECTOR) FUEL STORAGE TAJK , HAMD PUMP AIJD ELECTRIC I (WATTS OR EQUAAL) LEVEL COAITROL ARE FUR►J15HED BY ELECTRICAL OUTLET • " Co11TRAGTOR. •,I,.N12LTO. SCALE 1 2• PLUMB. CONTRACTOR SHALL IW5TALL ALL ABOVE ITEMS 2 a FILL PIPE TERMIUATED WITH WATERTIGHT N. G.W. PiPIUC; Ilk' pvI W&WV- %IA ,AM-EV- EXCEPT GENERATOR. FILL CAP LOCKIWCB TYPE FILL BOX. 3. PLUMB. COUTRA- SHALL FURWISH AND IW5TALL ALL PIPE r1,411HOLE GRAvEL AWO PIPE ACCESSORIES FOR A COMPLETE ItJBTALLATIOIJ. 241x 241xroll CORR. 1ROW SLEEVE - 4.. TAR GOAT Uv-AoevAP_ouND 'Pt'Pkm6t. CONIC. PAD 2$� MANHOLE 24'I EXTEIJ510►J WITH 2" WASTE COVER AND �ASKET,) SET IIJ FINISHED FI)JISHED FLOOWALL 481I x48"xSo CO►JCRETF_ PAD. �I R I .•_ U FLOAT VALVE RETAIUII.IG WALL_ i I 1.110N " SLOPE (FURUISHED BY 2" VEIsr LIIJE TO l_h CHECK VALVE ION DETAIL A.C. COWTRACTOR) FUEL OIL APPROPRIATE LOCATIOU --fi TYPICAL WASHING MACHINE CONNECT � RETIJF2IJ LIME WITH APPROVED WATER `� _-�a GATE VALVE � PROOF/FLAME ARREST T T FUEL OIL SUPPLY LIVE CAP. (SLOPE TO TAWK.) NOT TO SCALE-- \ GoFrl Inc�7nuS I t7umv Wmk 441-0%E SLOPE FIRE SPRIUKLER DRAIaYSTEM 4 \ 2" TO NAGE '. .. .f :, .,��_ --' :_-...••:__ _" STEEL GRATE WA5HUJG SPRIIJKLER SOLELIOID VALVE- TRASH M -IIII IIl�1QbGK. IQ TOWER BASIAI I FELT III LOCATE APPROX. 6' DOUBLE' SWIfv931 TOP 'ABOVE FLOOR. JOIN,Pi OR FLEXI _ •�%..- — o ' ,gg. ;: _ . _ d ° . . COIJI,IECTIOt 1 % - 12 PEA :. C.L. OF TAUK O OF 113" IMIAI. I I ROCK _ �000 GALLOIJ G ° �IBED - FIBERGLASS TRANSFORMER V PIPING DETAIL AT TOP OF TRASH CHUTE MAKE-UP DETAIL AURORA KIS5- • • • '• • '1,• • �•• i• iv • ♦I• • I I• E.W. TOP 4- g0'T`POM- _ I I 1--=D I I I —_I I I —_ — I/2° GALVAWIZED g"CLEAR-- - WIRE ROPE. SUMP PUMP DETAIL - DIESEL FUEL STORAGE TANK DETAIL F�® NO SCALE NO SCALE I AIR CONDITIONING LEGEND AP ACCESS PANEL STR STRAWER ---fl4-- GATE VALVE SR SUPPLY REGISTER 0 THERMOSTAT -— CHECK VALVE SG SUPPLY GRILLE O HUMIDISTAT BALANCIQG VALVE RR RETURN REGISTER ® FIRES -VAT BUTTERFLY VALVE RG RETURN GRILLE FC FLEXIBLE DUCT COMM. 2-WAY VALVE ER EXHAUST REGISTER © PRESSURE GAGE 4i 3-WAY VALVE EG EXHAUST GRILLE BD BOILER DRAW --sue- FLEXIBLE PIPE COLIM. FF FILTER FRAME AAV AUTOMATIC AIR VENT /1� AMCHOR co CEILIQG DIFFUSER TH THERMOMETER %------ GUIDE'. OR SLEEVE CB CURVED BLADE REG. GC GAGE COCK EXPANSIOTJ JOINT FA FRESH AIR TW THERMOMETER WELL CH5 CHILLED WATER SUPPLY LO LOUVER SR-S 5UPPLY REGISTER -SPECIAL CHR CHILLED WATER RETURN FD FIRE DAMPER Ur_ UNDERCUT HW5 NOT WATER SUPPLY DG DOOR GRILLE EF EXHAUST FAN HWR NOT WATER RETURN SO SPLITTER DAMPER 5F SUPPLY FAN 5T STEAM SUPPLY AS ADJUSTABLE SCOOP AHU AIR HANDLING LIMIT STR 5TEAM RETURN EXT EXTRACTOR FCU FAN COIL LIMIT CW5 COMDEMSER' WATER 'SUPPLY MD MAMUAL DAMPER DT5 DUAL TEMP. SUPPLY CWR COUDEUSER WATER RETURQ SMOKE DETECTOR OTR DUAL TEMP, RETURU 915 REFRIGERANT SUCTION SO SMOKE DAMPER CFM CUBIC FEET PER MIUUTE RL REFRIGERANT LIQUID QCTE: ALL SYMBOLS AND A66REVIATIOM5 DO NOT MECE5SARILY APPEAR OU THE PLANS, t\rT l IPA f a �c--- I I ' nk -- ---- - - o 2,Z TE Q �..- ------ _ JJJ nDE 2_; ELGl. 1 ;AEfi TYY 3° ��v.I Pa_eu2 i - l I 05-1CD i } � �•I r �l�l= I r �^ '�2 K --- -- -- -- 3p \v/FD AT Fi-� I Above) , .. ' l _ I t s —._— --- — L_ O J t ry , a o, GROUND ,FLOOR - LEVEL a — SCALE 1/8"=1'-o T6=7ELLE T Lt alai . I �K (IIJSUt.A'(FA� RU�I UNp i�UNt7 -Pp I APf' T{I'E OLZIC- �,- Icv" FLUE IF < i ' PSG• I I u _- �Y/�1���J E { -- BOILER ROOM - - -- Q =-z•4u---=- � yn � 1 cwe EF• I I� - 5�1 -- - � - - -•I DE-5 Cr �-"r' SCALE: 1/4' 1'0' A oQ�) u , i ItV a p cou . rfmj(o El � � U�l��2CoRou � - IQiIIJ. 1=�1PUa� T� C�ILF2 Rr�. Ida: Fob Y'T• LoYotxr� � - PG -el - - 6pilcW'5 C F Ga-.�itE PIa�rJ FoR /GI'iL 3 LoGof1oN of erases �ht. f�G-� waTER — N (PP�JE 7e-12 (�6�vE� TfcE? T ctil I �.- 2° -IWta� CIfJd✓J(AT)p� \y axl2lEr�( CaS;4Sw orL 114 _ T i s PPE Cyr �L�T.) vaLILT 1 t ��l 24ui� rJ7oKF I,oWEfC. `� C �1' ) `�, ��� EtL FIrZI= OaMPER T •R ,. .-- 5���7r'IE7caL 24XIG DI£Kf1. c �(�UC7 FIrcE< �,�-hpErey I DID`- LoJvE2 I I of APT.TYPEt' APT. TYPE APT. TYPE APT.TYPE - i AC -I �� !1- - AC 1 III , - i 'II TE-3 }� _ iTE- -o [—) (r D..------ (AC 2) It 7E'9 TE-10 .r -- �, LD _ _ � 1 - of AC-2 f , x LE E G V TE-G TE-1 _ -- I -- �t - - z,, AC-1 (AC-2) AC-1 (AGE) - ELEV. LOBBY No. i �Tf �_ - �� ELEV. LOBBY No.2 DE5�r I�TE-5 - �4� 6 ` v - - , r - ELEV.I �ELEV.2 Itl� }ELEV.3 ELEV.4 x I L _ GARBAG� O ;'GARBAG DE-G w II, APT. TYPE DE-)� , (C-A— RM. �. , RM. I Acs f ( APT. TYPE i L� it [ - Tom- 4� o �l u up. uP _ I A _ i STAIR Noi�,STAIRNat STAIRNo� STAIRNoA i _ TEI I TE•12 7 7E-I TE=2 TOWER No.1 I TYPICAL FLOOR PLAN levels 2 to 9 SCALE I1g"= IT_0"-- r���, TO zWER No.2 _ NOTES I- INFORMATION IN PARENTHE515 APPLIE5 'To Top LE EL (9%A9 FL.) ONLY.. : a Ij F4 O •l _j Z Q Q Q U . Q 01 Y 2 O_ a.- W C] U Q z Q rn J a. O cc ~ O N O _j J W LL 9 a w J H REVISIONS 0.1 DATE I BY JOB NO. 8I22 - I$ SHEET µ +y74 r rn ^.i W I ti r . v.i n 'h .. u G u a. i:.. ✓r .t'. _r � v.. M- .. . N 'm., ... 5. r , w.. Sr 4 .fi.'..ur ..:::hi` ,.. ....r .. ,.: .•. a :.:.,., , 1.. .,: r a.�. .y�:I,+hy«� , -.. x Sf �i Yf•9 r� WK0."1YY1aetis�.m'wsr+rw rvmse®mpaani. -_. -. AC-2 —OF9_ tI °ram el-)u Gt-m �c — I .+ 77 111 } IAL Ila, p 11 T�'3 28x(o iGx4C-13 18 X 8 ISx za cF � x 4 sIZ TE * 25 C FM I LINEN 10 + 64 I DINING _%� J O `. 28x8 I I 175 GFM v-� 411 ----I 14xGo I E 6x4 GPa. J z5 cF �xa s I I � - TERRACE 1-75 cFM �-4 4 �� 230 GFM KITCHEN l� �i�E7�) �y j -� ELEV. LOBBY N•I I i 14- I I I I I { L II L J, I x b� � — A �� HALL ELEVATORS 350 GFM - 6XA GB LIVING 25 GFM y--- - — - 1 CL w� D A NDRY _ 6-7 y _uG T �v/FD. /TT-� ,"�'IIf12 — �U/E�Bow d f,D 1 n Sox g 1, A/ �—, D Rd iL �� + :1 DINING -- 10 sHAFt �F-► WITH r. ' TH GARBAGE 1�N _1 -- —1 Jk ---- — 6 x 4 CQj A rP A -= a � 12 x � sR 25 GFM __ � fi uP Ta (( - -- sHaF-r \ F� � STAIR N• I STAIR N• 2 K T _ fl:. 25o c FM -- __ ii I LF I --Z --4-, �I 4 r ' I ' L_ J N PUMP ROOM 4'l� GROUND FLQ( SCALE : 1/4" = V-0- TRANSF. SWITCH ItMERG. GENER. a VAULT GEAR :4 PUMP ROOM T7 - TOWER #2 I 0 mh J�Jfl m I r ■ w ■ of NOTES I- INFORMATION IM PARENI`NE515 APPLIES TO 10P i 2- EF/Cf COMOINATION EXH. FAN $ y LIGHT F`UIZ"51HED AMP _IN5TALLOD D`r E1.50T CON-rRX_foK, Pucf 13Y A/C, GOMTRAGTO(t f 3- ALL 1ol .ET (Tf) � DRYER (pE) EXNAU5i 5HAFT5. I CHANGE 51W 'Co GONNEGT TO I I 'rZ I I Ye t 4 LOOP OPPNINra. AP��- , i :APT. OG I. Asa-T� 2Oo GFM 5F 325 CFM R F 2 C 1-- --- _ -- So GFM -- _ - _ _ y -- >- �IUKq GB �� f ao •* t - - 20 x (0 5fz -OF 75 3 FM G 1 � - � r 1 dLj 18X8_- I 4 - 20GF�},� I-_ L)<� 4 sK AG- I --- -- - - IOX8 25 l�E-3, 4`� I � "� 3 _ � / ��L 2F3 � ( 6n4 c6 0 b x A F_ ,. tL91 n 8 TO x co `siz I — aU7 P , 1 -�, fF x r \ _ / O �x I , � I I 175 GFM KA 7llfii _ _� A 6 8', II I!, a� ( L U\r. DOc7fZ vv 0 O C 1! i5000P51 _-'V - L— ^._ 8 14x4( l J 20X8 8 xG O 25CFM 6xq 5R ---x4SIZ i I 3RRlI l C17V i 1 i� _ 'I - 1 O � `, 20 -- _y — _ __ xT�j AC l n4G6 G G 2� F5 GFhA l ` j. X4 GB f S h x C3 � 176 CFM► i� J - , MFrAL) bnA �� dI , i ( 9 :9 CD - 25 c FM — ; I 20 rm G q 1- 1 li j / � � � � (270 C FM) �-- ' � y 1 1 I _ i 1 �— � I4 1 IGxG 512 IL r x -- - - 22o GFM 4 f _ 04 It 1 4 ! 1.a 4Ob Cx� SK IkX6�-� I� j 2O CrM j 300 CPM (35 0 GFM ) f /o x 4 GD 14^ 4 bUG'( S 1TH 1 i 25 CFM 1 L.Ooly { FD w, ELF? og- - .d _ I . I r" 2n8 K&.I �A 186 j Af 8T� 4 i (w AL) _ I ( oog OMfi APT STALIZ _ 2 _r�� - T -j2x6.. 5U13- DUG'( -- r AC-_5 i - - - - -- - -- _ Ijy �J ,- - ` — -- f -- cc 28x) 1 U J L 5 GFtvf ( �f (- 2 L__1 - 25 GFNI --- 1 _-- - I j (25o CFM) xa 2+XG Ore 6 xk 5K_ I rr xg — 25 cFM 1+- i A x rr ----—Z4�8-- — ��-- - - -- - ------ j SGOO PS ! 1 -2. WAY -50 _CJ14 wo (5 � M I - FIE- 6 , 5K (300 GFfv1) - - f2x6 5g_ ISO O FM — - 1175 CFM). IFTIK- ,L---dC'O I -i I �_- 00 I TYPICAL FLOOR PLAN'- TOWER #1 MATCH LINE SCALIE :: 1 /4' = V-0" 1i 1 I Nik DUCT 1 C L.G I z- FILTER I 4 NOSE CONK, (SEE DETAIL) -J 0 DOU8LE R188ED NEOPRENE _ SHEET ROCK V2" PLYWOOD II WATER WOOD SUPPORT HEATER SEALER STRIP ON (BY PLUMB. CONTR) ( FRONT EDGE OF I SHEET ROCK / FLOOR -- I PLYWOOD PARTITION - A. C. CLOSET. DETAIL -'- - SCALE 1/2" Ca" DUCT) 19 � 20 i 21 i j ry NOTES: 12x G 5R T I- INFORMATION IN PARENTHESIS APPLIES TO TOP 230 CFM 2- EF/LT 0E51GNA7ES C0118IN4, 10N EXH, FAN t L)GHT 12X(� SR FURNISHED AND INSTALLED BY ELCCT, CONTRACTOR. 200CFM I DUCT 3Y A/C CONTRACTOR . S 3- TOWER - I SAME AS TOWER 4L2 (THIS DWG,) -- 112 _-----�-' i (6xG 5R EXCEPT OPPOSITC HAND, Gx 6 SR 3ALL TOILET (TE) � DRYER (OE) EXHAUST SH4FT5 CHANGE 250 CFNI --- -__ __ . --_ 5tZE TO CONNECT TO II'/2 x II%2 ROOF OPENING lOx4 C6 f r � `5CFa r 20xG SR f: _ n 375 CFM I �---- � �;�I � _ i� 4��0 � IBx 6 ACI -1 6x - to D A (A ). T 28 6 K 4 5R 20CFtl Sx8 x G I — r C) 1i C 2 I 1 -- 14x8 25cFr1 4 - f Gx4--9 (/�\/) r 0' i - - T 11 SCOOP �(YP� ID S C 5R 14 -��-�- xG o I----- -� I { FM f8x8 wr1 lox$ , 4 2sxa 14xG 12x8- - � I --- -- - — --- - - -- . � x 4 6 ---+ 25GA 4FM SCOOPS TYPICAL r CPx4�2, 25CFM-- �� EF/LT�i ��. �.r- _,• I O E� --- -- --- I I - - -- ! - �- EF/LTri UI- „ C -- +------ —I p' T �E ONLY) Gx4 Gx4C8_ AC-1 O UUU I EF 1 _ _ --- w 25CFM —. I— - D tL x,?- (At, 2) is 'A G f 14x4 CB\.- 6x4Cg G)(4C5 (MET4L) I 175CFM 25CFM ! 'e DE-5 I I - -- — - - 12 x 6 Jam~ TE B J ELEV. COpeYSR ¢ Wm 1 24 X G220 — IG x G FM-- -- _ _ - IV - x ...m, 14 y , !2o GFR ---- 4 I f,. 14x GxG sfz I FIRE SPRINKLER b "a PIPING a NW CW PI PING ti I I n �\ 8"DUCT $., I to,, I 2' --- �% v PARTITION APARTMENT DUCT / PIPE COORDINATION NO SCALE APT' E� M: r (350 CFM) - Gx 4 C5 3 ELEV. 4{ 14x 4 DUCT WiTN I 25CFM y� ELBOW + FO t - STAIR # 3 STAIR 112%8RG � /- APT, 18 _ I I AT 6 TN F.Do� 1wn f j - 2xG 5u8-Duc la r1bNLFDS , t -- 4„� (METAL ) - $ -- - OR ' (AG-3 L. -' C I- - - r 24x8 4„� — - � — — 25CFM 4,� iTE II '25Cp 6 �� EFILT 6R I� - T 225 CFM' - --- I 2-4 C. 24xG (250 CFM) G>x4 SR f 25CFM Gx4 �(lox 8 I . c.. (24 X 8 ) -� -T — 4XCo Y� .12 zO x 8 1 12x12 CD 20 x Ge 5R 2 WAY 250 CFM (300 CFM) 3oocFM 12xGSR 12xCa5R 14XG(550c-FM) 150 CFM 150CFM 175 cFM ' ( ) (IlSCFM) 1 LL— I f� TYPICAL FLOOR PLAN - TOWER *2 SCALE : 1/4 1' - 0" OB OC i 9 7 TH_ I-. -a-L I Y;2, _2 it 2 5TH FI ooK } 21 2" nc AC AG cc 41, — ,�c' C1YW:4 ALL Ac (1WICAI, ALL AC (TYPICAL All, 1.D1V� C Af . BEi atV'J i APZ. BEtAW) 3 FlP(S, 6El�JiV) 12 12 11 — � z a 2 2„ � N 4yY > > > ' OL > 4TH FL—Wf� 12 7 17 I y2 I 2" I 2,. ,3 FLOOfC 2'r2' f`!,I 2 ND Ft1JoR _ -_>__ ST FLooK (GKO) i— Z _ „14 ,,i 0 a� O Q CONDENSER WATER RISERS . NO SCALE L, GiXXING-Tbwf5K tTrPIGAL) 22'' HIGH -k Sue - DUCT ("(T'PicAL) -- SHEETWfAL- DUCE (SG E AG-5 FOK SIZES) RaoFlu� C�LIIl..IC� �oK E�F-•3 4 4- , . I IIY� * lliz C'�'Pj�tu.) i (-ror� F�aot2 otiL� �„ C� 2 HhI Ia -4-4 5ub-D G•f f OYFICAQ 1 � I, �Xt-f�USt- _ 1� AT 3-W F-00K FAN -CURB DETAI NO SCALE FIRE RATED ENCLOSURE 6Y GELI. COWT.) SUB -DUCT 4 i,�d METAL .DUCT DRYER NO SCALE SUB- DUCT 22" MIN. FLOOR G G .Opg - :,R0--'0`O O is 2)( 0 ,.,.. , I iv , W-v w13 1 f O� 5 O • :. THIS APT. IS SLMLAR 'I DEN 19 13 '� •I/o ®+-®� a APT. B i. TV APT. "I' eyC:EPT OPPOSITE A PT. APT O 14 HAND. SEE APT,°I"LAYOUT LL 19 SEE APT 5 LAYOUT' FOF, CZUAf TkT1ES AUD LIVINrg ROOM 1 I SEE APT. E LA`foUTl SHEET E•3 FOR II C1RculT5. 5HEET E_4WKLAYOUTt. LAYOUT TW5 APT. '! A PT. H 14 KITCHEN\ _ I� TNI5 APARTMENT. QD _ I F �P 2 ,AT(�7 [I�f FaYE R_ I �; p 21 IT Eli I\.� `gPLE _. 0711- 1�.�n" Ifo L-_ IS -- - -- CAPLE 0901.1` �I.._(1 1 , C- - '! (�' W 1 n� Ew - 15 q /,' � s - (o I P�OC .TEvBDARD 1 E p,���-1 JSP .i T t3 V O { So __ ..� SBA-n IS IIR Is 3 F I - A 1 D Io 1 :_. .4' - - . J _ _. 5O :I -�� -__ ,. I GFI �I� J F S I L C 7 is o 11 iwig a- 5 _ ------ -------__— � � _ �.�• , .% 6 © ® n0 ^J _ %EFRAGE ' ? I �A 9 01 fj -- to 'GiGGN sl?•'t-'`Y �I' ��� f21 2S� Z.3 A I I�-� I BRACE ® a Rp V17 GFI WP in Q , I A 3 I ISVia 5P^ E1 EI L� j FIRE LP¢M i/0 EI.4 r_- -'Bbc' =.�- 15 13 _ wP(6Fi) FoYC-F --_--- 3F, N` ELE, N=2 _ `19 F PneEL l C DD I APT.© 3 � AP 15 J =� 1 I L V It. �'ar!tI; U� ELL-V N ELEV, N=4 0 15 `-' FOYER I i7 --� 2 X2 1 a � , ..F IS 24; LIVINC=a RooN1' LIVIN( Roots - rl, ao I 1 i Q 15 Uu rr I ,.,,._�' ' - _ ICJ.- `I" v D ':. 1 Q,. ._.. �n ♦ - �1' Ii� � I, J 9 �-_2 _ � _ _. _ __._.- _ -�` � ,�- i n. !�_> sD J ,-' _. ,. �, b rc .<_15t~-�'--1 I--�--f `®Q f�"'11 C LI. _ F--[Pb---4 t--�-� :I I 1 _ 13 .-_vER1FY I 1 0 O�SECTORY ia,-OIRECTo v c A ID ,,._ '�ocAiloN all- g, nTA,.-... r l4' W 1,J) 3 g �-y pvc EWk e ' ' .. ' I i �1l M� % ••:e=_ei .....:-I` - _. ... ,11� ?•----_•__ ! `-'r i I i _ _ �' r -.ji _ J _ •� 11 { ' Il r._ pp I - - 5'�_..'?I-...�.._., �',N--� F-___-,. i��. '.�.... '•60. ;:.-. .:. ' L I'f _:..- IF } i_I 6,R 2°C. To Mn.ry I7 Il I -'-_Iit 5 T ; ti{�. qq CC ;t,. _.�t.,((�+ "; .. +. yLl 1 LLI TEL. EALK,L.oAkV ..0 To MAN... -. t�` 1111 . _-„�, i _ F% — __ rCRIZACE i �i - I(•P.. 4. p ! I m r 13 20 �NH �2� -, p 1 CT 5 D 6 - TEL. SACKBo I' �� a 32 I l pD i, EF, 6EDRooM L, _ _ 1' �1----�f-i 1•-14 �..-� Ir5 1 } 6ATH j Fj 20 GFI• / O STA12 N�2 I STAIK h1%3 W,;� .. .. LI-2 PNL-7 1 RC _: 8- _. +8-o'APF 1 R FF 32 ..,��g, _ �2O L2o GAFB. RM_1 _ C i R.�� +8'-o %a ®i �wd.� Icy _ + Ila I(o�., 13 CODU PpE WATER TRR"ajM EIJT _.__.-_.___--.-- 12 7�. 3 SD LI-10 GFI vJ.P. _-.-- 0...._-ram. �GF__. 1Z_ j(i$ LI 10 GFI> > GG / Q EQUIPMENT r p - HI 14 Ib,IB... ; GAr<6. RM, c. .�- -- /�-- n 914 1/0 , 16 5 5 Uf..l RP ~H J COOLING TOWER. , E ��JL�i`I I'I.I�i ;l la nit ERr b 19 'B P_I _. ._.. %j EI �... a LI •'S. -__ . _. O .._ l.L ._ -._ �I1C22 O2 +I� ? �`, �. '� 11 �E MEj R F AN OZ�SE/OG EF`` TI 014 A HI -I �P-Z 3 I MAKE-UP PUMP KK I nts-I — 2 KITCHEN EF EI I =r^ oEMERG@NcY GENE�ATaIZ �EM-1,3,5 MPId k'NISICe M HI-19,15J1 14� DEN .� `a ._. EI-1 NF NaFO RNIE GF, r QooM OM1NKS EI-3 BEDR ' M { WIc_ 1 0 - ` ..9..-.rT �•'_'; I . _PUMP ROOM MPtN Mat so 6 Imo. I 22 17 EL Ev (ro en q_ EL6 1'3\-2 t'I Ire Ib�.7. eM _ wv .. a= - .:. EO 1 GENEQhTp _ .. 13 12., I % 'Ito '17 I D 12 TE2G02 FIRE Puy J ,0 11. a .I 1 I Q ; HoUSL PUMP : F R. EN E,T. V ll-2 .._.. MP CGF® TE 22HcE ! 1 DAMPE2 tN GA SE of lR ® FIRE PUMP (S6T. R15k Q� f PQIMaRt puCT Bpu� I CHECK. WITH F,Q,#L.S PK•S, Folz a NOTES: .. R64Ule6t-lEui4, EI�.EL6V,Dl5GOUNEcTS l . PROVIDE ,AND :INSTALL FUSED DISCONN`ECT• coNN. FOR DpK TANKI SWITCHES FOR ALL A/C UNITS. FUSE IN ACCORDANCE WITH MANUFACTURER'S RECOM pp----� MENDATIONS . ATWALL of swua .Rn, t'I-o"pFF ALL WINDOWS, SLIDING GLASS DOORS, DOORS, ETC." 'IN EACH APARTMENT AT GROUND FLOOR, SHALL BF 2. ALL DISCONNECT SWITCHES SHALL BE IN-. PROTECTED BY INDIVIDUAL SECURITY PANEL. STALLED IN A MANNER SUCH THAT THE AT EACH APARTMENT PROVIDE WIRING AND MAGNETIC LOCATION WILL MEET NATIONAL ELECTRIC TRIPS AS 'NECESSARY, CODE CLEARANCE REQUIREMENTS. t (ARTICLE 110.16). 3. COORDINATE BATHROOM RECEPTACLES WITH RECESSED MEDICINE CABINETS TO AVOID PIPING CONFLICT. GROUND FLOOR - LEVEL I, —' SCALE 1/811=1-011 4• WASHER AND DRYER RECEPTACLES INCLUDED WITH GRAY BOX, SEE PLUMBING• DRAWINGS FOR EXACT LOCATION.- � i E F; - G K L �-- 0 BALCONY WP i ■ • k ■ • • NY I �t — ` i �. 4: •ifi e c �Ir �',�� z_'■i • 1 F • - ■"O' • LNYOUT I%I 0, qUAR • M All LIVING ROOMoil a _ Cv,y,l O .. IV:"R I b ILI XF�i: a' 4 ��I � • • �II f }kI - rip KITCHEN M) LOBBY • • • Q 0QD- i I Omy, LO LDL�� w • i■�5 a I BALCONY WP t NOTE 3 3 OTHIS APT IS SIMILAR E TO�j o APT. E. XCEPT OPPOSITE HAND. SEE O MASTER APT. E LAYOUT FOR DEN I BEDROOM QUANTITI ES At ID CIRCUIT% LIVING ROOM I i I © •ELEV. NO.2 pi BEDROOM MASTER BEDROOM - • • � �17�.'#`.'-" � t4�?+'liSwrniwNP.-�i'�;,k• . —_a _ � r _ Y � � =: M N • — r...- \ ~ • II' I, ' 1.1 1� .� ,�., a II ® —I l ! 0- ��I"SF/, • �;; ©© — � ,� � :- �iinmalvuuNlwi�, �iNUNnu���u■� �� ,: am S •t LAI -- ALL• DISCONNECTSWITCHES SHALL BE IN- STALLED IN A MANNER SUCH THAT THE LOCATION WILL MEET NATIONAL ELECTRIC RP CODE CLEARANCE REQUIREMENTS. {--------- (ARTICLE 110.16). COORDINATE BATHROOM RECEPTACLES WITH RECESSED MEDICINE CABINETS TO AVOID PIPING CONFLICT. BEDROOM KITCHEN II I i� 1 DEN MASTER BEDROOM 44 \ P ®el� ij 0 - WIF 6a_ 'I/ t FLOOR PLAN - 6nwe r .n �w* •� — N• OWER #1 (1(611 ( / I 4 BALCONY 12 BALC 0 NY 0 � ,---r,+s � mm �f I 13 1� ll'ok=" DEN \� DEN MASTER `� 13 APT. BEDROOM KK APT., �E 16 i Is LIVING ROOM I LIVING ROOM 14 15 JJ ( IG, I + ) 13 i5 131 14 I ° DA: 4 \\� A0 i _ J , I KITCHEN AAALL 5OAFF of rt11 —� ,----�FH J r ' I i3 1 Flo 114, i I I Il BATCH _ - ,o N0. i' 12 12 W.I.C. DRE_SS�G O °D �- CC ' FOR EXACT LOCATION OF III 11 (HALL IB�13 O I 15 � i GFI N )7 ,.-- � DINING ROOM LT, CHECK w'/ ----- I ARCHITECT. (TYPICAL) W. ®D �—� c — FOYER 15 ee r� -_ 2i 3 ii {_ 3 I4�1 `W.I.C. � I . I EWH � i S.P. - — — - — r-- S,-I Il g He2,4 I6 19 - 15 is s PN'L"E SIP DINING EE O I(o p Po",L 22 -5 CFI 'B,AT H 6 g FOY ER ELECT. CLO. - �! jN�0.3 DD 1� BATH s -- HII 5 6 ) 11 t _ i 12 _ -- NO.I — GF�- Iln IIB 15 1 �� S0 29. - / _ 17 �� _IT_ - _T12 r - _ DRESS•IG �IS FF — L� HALL I 15 e 20 --- �- 12 22 �Ewµ c ®O I KITCHEN BATH OO O O N ELEV. LOBBY NO.2 - -- GFT _r O18 ----\-}I _ _—.I G� !. O N RP' i I ALL I I I -. — - - -'a - Ig 21 23 ' f ® - ` I -- ,� - — - - - 13 C� O C� I — — — 14 zo - - - -� �- - -- Iz11 t4 I' .1 _12 : - BALCONY F -- 15 13 wP ELEV. NO. 3 ELEV. NO.4 I j' 15 FOYER " 17 19 rI MASTER BEDROOM � + I A 91 I DD I APT. G OF BEDROOM ie> 1I O b I7 I SMOKE --� U J 31 oNo\�A ! �N'L'F' f LIVING ROOM PROOF Q n _ �) - O � 17 EXIT STAIR NO3 STAIR NO. '-I ®� 2A 2,44I Is 17 t9 _ I IS 13 , W �- _ O 28 rae -BATH 1 - ---�-T" - r wP � I 1 .EWH 15 BALCONY DD s,7 DINING !BATH 15 ' O 2c 3o D 32 N 0.5 20 CC FF 2. 1 - - -- 7 5 �-- 9 19 3 KTES ; `� ' II I 1. PROVIDE AND INSTALL FUSED DISCONNECT 'SWITCHES FOR ALL A/C UNITS. FUSE IN ACCORDANCE WITH MANUFACTURER'S RECOM- MENDATIONS. 2. ALL DISCONNECT SWITCHES SHALL BE IN- STALLED IN A MANNER SUCH THAT THE LOCATION WILL MEET NATIONAL ELECTRIC CODE CLEARANCE REQUIREMENTS. (ARTICLE 110.16). 3. COORDINATE BATHROOM RECEPTACLES WITH RECESSED MEDICINE CABINETS TO AVOID PIPING CONFLICT. 4. WASHER AND DRYER RECEPTACLES INCLUDED - WITH GRAY BOX. SEE PLUMBING DRAWINGS FOR EXACT LOCATION. - MATCH LINE u GFL t— 3GFM I 28 — — 77 - �� I DRESS�G 513 D zo II HALL Piro a qp �20 15 W.1C. _�7 7 12 22 RP _. 3 13 1-7 KID Q KITCHEN 22 BEDROOM i9 I I¢ 5' OAFF 12 MASTER BEDROOM �11 DEN I ' I L 20 3Ow 12� ALl - 3 IS 22 22 11 1� - -- - it - - --- 1(0 IMF 13 II , zz BAL(Ooyi L - - - 01i H - - --I 14 13 14 i FLO,OR PLAN - TOWER 2 SCALE . 1/4" : '1' - D" F) r (G 1 Ca r 4 .' �2 �C3) 41.� i� 7,. y .. y.i ... ... i.. � ..-., . ...E .. I I I - I I I I 1 1 I f I I I� EF F M 3 E3 �- _ _ _)_� ~'GF-4� JF EF4__._._— - -:- t-.___ —_ �... _MWP F4 '1-61 Lj - I DISCONNECTS FOR M EF-4 M I COOLING •TOWER PNL: TO AC RM. I F•3 s ------ RY EF-4 T — — I EF 3 " e n E 3 I ,Imam - E2-12,14 �T57A oLINRRTCRS E2 ` E2.13,15 I _ _I 1 w I I— -10 T b\ 4 eF2 ® E2 io I OOD 5 D 0 PNL. Sp 1—PD- I p 0 : ® EF-2 ` EF 4 0 I ®� i E2-lo ,� dlL I (� Q I EF 4 dn. _ E2-10 1 } AC, I DOWN T0l' I f�sF 7 ~ > ♦ Pj E2-10 - w12 I I FI2 ^- L E2.19I 5W FOR n —� _ I I WP i F-12 BOND A:R SHElI __.. .a I _•a (TYR) , CHUTE i4 -- — _-'' =- -- _ i7 EF3 M - F 12 I—�—I p f Amok EF'3 � M I I Eup M EF•� F-3 _ _ I WALL LT. UP To DOWN TO SW. WALL I F 1 TRASH CHUTE LIGHT 1 ,I I WASHER 1 1 I I fi . it I 14 IS 16 . 96 i fit - - - -----�-- I I N CA III J8� is +4'a• I.ai I AI I R TERNII AL (TYP L) RUN DOWN CONDUCTORS ON COLUMNS DOWN TO GROUND FLOOR IN I" PVC, CHECK FOR OBSTRUCTION PRIOR INSTALLATION ( TYPICAL) TOWER # I r ROOF PLAN level to SCALE—I�8"-1r O" 20 ' TOWER # 2 6 1 OBSTRurTION L*HTS E2-I$ EF 5 f� IF I� I r-•9 (TOWER F•II (TOWER ;-2) I. I 00OWN LEVEL 12 TOWER #1 (TOWER #2 SIMILAR) 101*60,16110 low �." ao- 9T" FL. 1 6`4 V 7TH p 10 > 1 57H FL, 4 2 F m OBSTRUCTION LTS. EZ-13 TOWER # I a Y �,- �LEVP.ToR CON-Tf�OLLE(R. - �" 2G E L.EvA`Co RS CA5 LIG 3„ t23-t'a_ K COIdTR r WARE WAY E2-t5�t�,1��'y—s� 1E2-12,14 2-# t2 Tw. - 1/211c. To F.A.P. CoNTRot - SEE A1C DWG.S $ SPEc15, PN,L EM.. M- 2,4,4o z ,r0 MA4N DISC 2„C 3 °t2/0 t 1, CoGGLING -r yvJEK DfSGON NEcT HOUSE METER L '; i"C. To TRANS FoRn VAULT ........_ _. a: ELEV%{-sc�R. CQh1TRpLLER. ELEVATORS _ AC-5 E'c�-15,11�i9 � SIN DISGotil�yEcT 3 '12/a 4 I "8 T IAYV TOWER, *2 r��i JE2 ;rTJ--7r i. AUTOMATIC TRANSFER SMTCH SCHE.DUL- — ATS # 1 (i RE PUMP) 8 A-3P- 208V. - ONAN NO. OTOM-80DA-4/la ATS#2 (PANEL EM) 400A-3P- 208V. -ONAN No, oTUCK- 400A-4/101g ATSu3 CELEVAroK5) 40OA- 3P-208V. -ONAN No. o-CUCK,- 400A-4/loi 3- 350 MCM 4 TO PHOTOCELL -roRK 21oo 1- 250 MCM -n-Fw � OU75IDIE 6LD'G FACING NORTI IN 3 C, / 53gT{lw $ ills -r {w- i'/4c, xA/-♦,3tn,,., -W-ti- It t it, tt,� -� u "', -n� v,tyf Ch It: I'M 4U w --- ". 3 - M, - R va a.10 ow NP m to -OWN 1-0 WS, 't, AT, -4 m wn,�qe� ITRZ11,11- �`Zlllrl "OF f I JR, vol 8 0,..,. MilMA l is°:..,: x ....'r<y .w.. .. a..,.,.. , „ .. .,. x ..... .r.. r. va � .+... ..._.. ..... x. ._:..,� . .. ..<. .,. "k„ ,.x.: , e^:,.« ,....9, i .. '•'', r. .l ,. ♦.. .. .. ... b :�'.. ...., .. d , Y ,:.... .a .X. tR.. _...,. _,. ,. .: -H ._ !y.{ .. ,A.. ..... .., ... .. ...r. 5 ,a: .. _1: n ♦ F .. Se� w... '"l. ,, a 1 J. v. . 5 x a.., a. . x Ulf ., s5 G"'ae ., ..,a, 6^ ,e A s, �. , : £a:* <._. ,..r. x �.. .. ... 3. .. _: ,,. ,. a ... a ,.a". .. ' �s ,,. .. .£. .,., ,� :z. �� rH.ht�Fl n���x .E- ;� _a1r .ti,(t �' s, �;fz ,.s@,,.; Jr, _ •:r- x a ^.., v. 'I:;—`,3I ..."..@s p 1 , I sr. r y I'. � t as Fx bi �.+� .. ! 51 5. ♦.. ^ Imo.. { ro^�•=!'�^ !• ! s:, a:- ,>x x`wq P'r ta- '"d, •+ a C+-x. ::...^,� 1:. o-.. .... 6y h_... �,y lek ,'. f .7�"d V d'� 'saaF 's45w xi.[ ..., �xrF' , Ctf:": n 3` s, L � _,.. o .�f, ...%'iy�rai.k ,.:.:: xG, :. .a ♦5 k"'ti .a4 -k',.>': .5a,71,v?. E:"�.",' ♦ . e;. rn 5.:. •f:.+ .... r , ::. , a, :, v,,,. tk , k �*;, ✓1§'`, . r .Yee ;� , . aC ... t s a+". ra,{, ex ",fi1 r.5+ • „a.,c. E,; .,:. , ,. ro� -.:.9 � , t. "� 4 �f ,m .�` » ..... sh dF. ^� � sa'i''my, �. @y f . %, ., ," ,y,.,,, a. .+ ,,.:. <.a ;:! _ . .. axs"i F,.. £S^nl3ie_.�� ,� ..r-a ( ,.:. .,. c to n` .l� W `:. .:; J��, .a. ... 2+m! �.. .+' Sk ig' - ,5,�.♦$d r:1 � ,ti+.. . t :tc. !. ..i'.x ..[. .. . .. n.'i _ ... i. Jlr ,,. .:- ...... : „^. . >.. ._ ,� _a _ _... s .. fi n. Ti/. A m ♦.. 1 . x. ,n G AT �. ... .... .... S a_.. r .. . c . .. :.. _. ^. \ t Y 5 }` ., V t ... ... . ♦. r. ti.. ,L^. i u,. i a.. i..9 .. . .... e .. .,..f ,. ... , «.E ,♦. ,.. A .. '.... ..: rr .......3 Ji•. .. .. ».. St, .ro.ce ,...r 4' ,'S 'u, 4,.... o ry c r , ,. .... ,.. _.. .. +. ... ... p.. . .a.., , -.. .k , '1. n , . .a:, ,. a:J a 7s ,..o,.S }r .!C . .,y• r: x `4's,.` R � ,4 A 1 :,5'Fi �' ! M.: r ^r . . i . C }, ♦,. ,' .� ins, ♦t � .. � � x�� mm ���,� r f!, F I^ J^tyu z ...-.;r?yy & xa �"e :�: ,. 5 .., sv, .'., , 5..,, f „ !. a "J h ', , a. ,;ti 1 r r y. . d f �.,, ::3x+ksE•`t 's �'tTj ,eE .'�� Ys ' A"sa ,+ t a� v w, I @ x +, °!z<' . .,. , �' ax'�i`s „_.�. *.�v � ,. :, _ .rr I, .a.l. Mr-n. ,., . . ..,,. �.. ... ., .> ♦ . .m,x �ast's..�,5uu><.'fS ��...�Y ,.�sc'*,.. s.,x; t ;,.♦ +~,...., w:?a ':v., a�i`:aPr?;6 k=:x, 4Ax. .; .d �"� g3rvn`Y 0 "AS -19 n. 8 PHOTO RELA ToRK # 21oo 1'�4+ GALV. OBST NO SCALE i 31 FINISH FLOOR FEEDING CONDUIT cR RELA`i (115V.) EDUCING BUSHING AI.V. CONDULET RUCTION LIGHT DETAIL O O O fSSOR FOS "CONDULET" (THREADLESS FOR RIGID THICK WALL CONDUIT) O O ow-i am / -THICK WALL CONDUIT NOTE: USE 2 HUBS ON ALL STUBS 3/4" i AND SMALLER BRASS COUPLING FLUSH TO FLOOR I LOOPING CONDUIT FEEDING 2ND OUTLET OR STUB ONLY FOR STRENGTH OUTLET STUB UP DETAIL NO SCALE ABBREV IAT IONS A AMPERES AMPS AMPERES N ' A/C AIR CONDITIONER ELECTRICAL CONDJ AFF ABOVE FINISH FLOOR AL ALUMINUM "T" CONDULET O ,I, NDUIT CU COPPER FLEXIBLE CONDUIT O 11' �I' CWP COLD WATER PIPE MOTOR OUTLET BOX ® i� EC EMPTY CONDUIT MOTOR �I 2 EF GND EXHAUST FAN GROUND CONCRETE BASE O HP HORSEPOWER SEE SPECS FOR R TYPE OF ISOLATION 7 i1 4 O JB JUNCTION BOX II j1 KW KILOWATT FINISH SLAB ® iiY iI Co LTS LIGHTS MLO MAIN LUGS ONLY CONDUIT COUPLING PROVIDE O I MT'G MOUNTING f UNTIL USED. y PC PULL CHAIN �` PH PHASE I� PVC POLYVINYL CHLORIDE REF REFRIGERATOR RE CPT RECEPTACLE MOTOR CONNECTION DETA`; RM. ROOM S C A SW SWITCH TEL. TELEPHONE TV TELEVISION V VOLTS j W WATTS W/WITH V h WP WEATHER PROOF 1 SEALING BUSHING "OZ" CAT. KR300 CONDUIT RISER GRIP SPLIT, WITH LACING HUBBELL CAT. 022-12-026 CABLE SUPPORTS NO SCALE "SEALTITE" EXHAUST FAN FS "CONDULET"__ I WEATHERPROOF SWITCH COVER PITCH PAN ROOF SLAB FOR 120 VOLT 10 FANS: INSTALL SINGLE PHASE MANUAL MOTOR STARTER W/ O/L FURNISHED BY MECH. CONT'R.; WHEN OTHERWISE INDICATED FURNISH & INSTALL 1P/20 AMP FLUSH TYPETUMBLER SWITCH. FOR 30 FANS: FURNISH & INSTALL GE TYPE "RB" SWITCH, AT N0 23685 FOR UP TO 1 1/2 HP @ 208V 15 HP @ 480V TYPICAL ROOF FAN DETAIL NO SCALE LEGEND Q LIGHTING FIXTURE, INCANDESCENT, SURFACE MOUNTED LIGHTING FIXTURE, INCANDESCENT, RECESS MOUNTED LIGHTING FIXTURE, FLUORESCENT, SURFACE MOUNTED LIGHTING FIXTURE, FLUORESCENT, RECESS MOUNTED F-- O—{ LIGHTING FIXTURE, FLUORESCENT, STRIP TYPE, SURFACE MOUNTED 4 LIGHTING FIXTURE, WALL MOUNTED, HEIGHT AS INDICATED ON DRAWINGS e EXIT LIGHT, CEILING MOUNTED, ARROWS AS INDICATED ON DRAWINGS AND FIXTURE SCHEDULE EXIT LIGHT, WALL MOUNTED, ARROWS AS INDICATED ON DRAWINGS AND FIXTURE SCHEDULE, HEIGHT AS INDICATED ON DRAWINGS Q POST LIGHT C�0 POLE FIXTURE SWIMMING POOL LIGHT - SEE DETAIL ONDRAWINGS O FIXTURE SYMBOL - SEE FIXTURE SCHEDULE ® CROSS -HATCHED FIXTURE INDICATES CONNECTION TO AN EMERGENCY CIRCUIT QS SPEAKER, SURFACE MOUNTED S; SPEAKER, RECESS MOUNTED (f)j TOGGLE SWITCH, SINGLE POLE, 48" AFF cl), TOGGLE SWITCH, 3-WAY, 48" AFF C P1 TOGGLE SWITCH, WITH PILOT LIGHT, 48" AFF ELECTRIC PANELBOARD, FLUSH MOUNTED ® ELECTRIC PANELBOARD, SURFACE MOUNTED e- SINGLE CONVENIENCE RECEPTACLE - 18" AFF UNLESS OTHERWISE NOTED DUPLEX CONVENIENCE RECEPTACLE - 1B" AFF UNLESS OTHERWISE NOTED DUPLEX CONVENIENCE RECEPTACLE - SPLIT BUS, ONE-HALF ON SWITCH CONTROL, 18" AFF UNLESS OTHERWISE NOTED DUPLEX CONVENIENCE RECEPTACLE - ABOVE COUNTER - KITCHEN 48" AFF - BATHROOM 42" AFF ELECTRIC RANGE RECEPTACLE - 18" AFF l�'NLESS OTHERWISE NOTED (B - DRYER OUTLET, 48" AFF CONDUIT IN CEILING, OR CONCEALED IN WALLS - ARROW INDICATES HOME RUN TO PANEL, LONG SLANT INDICATES NEUTRAL CONDUCTOR, SHORT SLANTS INDICATE CIRCUIT CONDUCTORS OR SWITCH LEGS. - - - - - CONDUIT UNDERGROUND OR IN FLOOR SLAB �- FLEXIBLE CONDUIT ELECTRIC MOTOR - NUMBER INDICATES HORSEPOWER CO MANUAL MOTOR STARTER ® TELEPHONE TERMINAL BOARD Q JUNCTION BOX JUNCTION BOX, WALL MOUNTED, HEIGHT AS INDICATED ON DRAWINGS Q THERMOSTAT - 60" AFF (BI TV OUTLET - 12" AFF TELEPHONE OUTLET, MASTER, 60" AFF UNLESS OTHERWISE NOTED D TELEPHONE OUTLET, EXTENSION , 12" AFF UNLESS OTHERWISE NOTED © FIRE ALARM -MANUAL PULL STATION - 52" AFF © FIREMAN TWO-WAY VOICE COMMUNICATION JACK. 0 SMOKE DETECTOR AND HEAT OF RISE COMBINATION, CEILING MOUNTED RP = REMOTE SECURITY PANEL - MASTER. BEDROOM Ml SECURITY T.V. CAMERA O DOOR BELL - PUSH BUTTON DOOR CHIME & TRANSFORMER Fa�li DISCONNECT SWITCH - 3 DESIGNATES NO. OF POLES - 20 DESIGNATES FUSE SIZE - 30 DESIGNATES SWITCH SIZE. (� COMBINATION DISCONNECT SWITCH AND STARTER 0 SECURITY DETECTORS (BUGS W/T.V. CAMERA) © DOOR RELEASE (FIRE & APT. ACTIVATED) ® FIRE ALARM RELEASE (FIRE ALARM ACTIVATED ONLY) DOOR RELEASE (SERVICE DOOR RELEASE FROM FRONT OFFICE) INTERCOM STATION (TIE UP TO TV CAMERAS) W/PUSHBUTTON FOR CHIME AT OFFICE NOTE; ALL SYMBOLS SHOWN ARE NOT NECESSAR11 ILY USED. .N lw ■ APARTMENT A LOAD COMPUTATION (NEC 220-30) AREA 1840 SQ. FT. (APT. F SIMILAR) GENERAL LIGHTING = 3 x 1840 = 5520 W (3W/SQ.FT.xSQ.FT,) SMALL APPLIANCES 3 x 1500 = 4500 TRASH COMPACTOR = 1 x 860 860 DISHWASHER = 1 x 800 = 800 GARBAGE DISPOSAL 1 x 800 800 RANGE = 1 x 12000 12000 WATER HEATER = 1 x 4500 = 4500 CLOTHES WASHER = 1 x 860 = 860 CLOTHES DRYER 1 x 5000 = 5000 LAUNDRY = 1 x 1500 = 1500 + 36340 DEMAND LOAD FIRST 10,000 W @ 100% REMAINDER 26,340 W @ 40% COOLING LOAD &,FC 4000@ 100% HEATING LOAD & FC @ 65% I = 24206 = 118.0 AMPS NEUTRAL LOAD GENERAL 5520 SMALL APPLIANCES 6000 I1 +11520 3000 WATTS @ 100% 8520 WATTS @ 35% PENTHOUSE 10000 10000 10536 10536 4000 4750 25286 24536 25286 I = -2M = 121.0 AMPS GARBAGE DISPOSAL 800 TRASH COMPACTOR 860 DISHWASHER 800 CLOTHES WASHER 860 f 3320 x .75 RANGE (8,000) x 0.7 DRYER 1200 15272 1 = 208 73.4 AMPS FEEDER 2d2 THW IN 1' "C 1N4 THW APARTMENT B LOAD COMPUTATION (NEC 220-30) AREA 1200 SQ. FT. (APT. E SIMILAR) 3000 2982 2490 5600 1200 L 15272 GENERAL LIGHTING = 3 x 1200 = 3600 W (3W/SQ.FT.xSQ.FT.) SMALL APPLIANCES = 2 x 1500 = 3000 TRASH COMPACTOR = 1 x 860 = 860 DISHWASHER = 1 x 800 = 800 GARBAGE DISPOSAL = 1 x 800 = 800 RANGE = 1 x 12000 = 12000 WATER HEATER 1 x 4500 = 4500 CLOTHES�WASHER = 1 x 860 = 860 CLOTHES DRYER = 1 x 5000 5000 + 31420 APARTMENT C LOAD COMPUTATION (NEC 220-30) AREA 1450 SQ, FT. (APARTMENT D SIMILAR) GENERAL LIDHTING = 3 x 1450 = 4350 W (3W/SQ.FT.xSQ.FT.) SMALL APPLIANCES = x 1500 = 3000 TRASH COMPACTOR 1 x 860 = 860 DISHWASHER = 1 x 800 = 800 GARBAGE DISPOSAL = 1 x 800 = 800 RANGE = 1 x 12000 = 12000 WATER HEATER = 1 x 4500 = 4500 CLOTHES WASHER = 1 x 860 = 860 CLOTHES DRYER 1 x 5000 = 5000 LAUNDRY RECEPT. = 1 x 1500 = 1500 + 33670 DEMAND LOAD FIRST 10,000 W @ 100% REMAINDER 23,670 W @ 40% COOLING LOAD & FC 3600@ 100% HEATING LOAD &,FC @ 65% 23068 1 = = 111.0 AMPS 208 NEUTRAL LOAD , GENERAL 4350 SMALL APPLIANCES 4500 3000 WATTS @ 100% 5850 WATTS @ 35% GARBAGE DISPOSAL TRASH COMPACTOR DISHWASHER CLOTHES WASHER RANGE (8,000) x 0.7 DRYER 1200 14337 1 - 208 69.0 AMPS FEEDER 2#2 THW IN I� "C 1N4 THW AREA 112D SQ. FT PENTHOUSE = 10000 10000 9468 9468 3600 3300 + - 22768 23068 22768 • I 109 AMPS 800 860 800 860 + 3320 x .75 APARTMENT H LOAD COMPUTATION (NEC 220-30) AREA 1180 SQ. FT. (APARTMENT I SIMILAR) GENERAL LIGHTING = 3 x 1180 = 3540 W (3W/SQ.FT.xSQ.FT.) SMALL APPLIANCES = 2 x 1500 = 3000 REFRIGERATOR = 1 x 860 = 860 DISHWASHER = 1 x 800 = 800 GARBAGE DISPOSAL = 1 x 800 = 800 RANGE = 1 x 12000 = 12000 WATER HEATER = 1 x 4500 = 4500 CLOTHES WASHER = 1 x 860 = 860 CLOTHES DRYER 1 x 5000 = 5000 LAUNDRY = 1 x 1500 = 1500 32860 DEMAND LOAD FIRST 10,000 W @ 100% = 10000 REMAINDER 22,860 W @ 40% = 9140 COOLING LOAD & FC 3600@ 100% = 3600 HEATING LOAD & FC @ 65% _'* - 22740 I - 220840 = 109.0 AMPS NEUTRAL LOAD GENERAL 3540 SMALL APPLIANCES 3000 LAUNDRY 15+ 00 8040 3000 3000 WATTS @ 100% 3000 2047 5040 WATTS @ 35% 1770 GARBAGE DISPOSAL 800 REFRIGERATOR 860 DISHWASHER 800 CLOTHES WASHER 860 TRASH COMPACTOR 860 2490 4180 x .75 3140 5600 RANGE (8,000) x 0.7 5600 1200 L DRYER 1200 1200 t 14337 14,710 14710 1 - = 71.0 AMPS 208 FEEDER 2N2 THW IN 14 "C 1 #4 THW APARTMENT G LOAD COMPUTATION (NEC 220-30) GENERAL LIGHTING = 3 x 1120 = 3360 W (3W/SQ.FT.xSQ.FT.) SMALL APPLIANCES = 3 x 1500 = 4500 REFRIGERATOR = 1 x 860 = 860 DISHWASHER = 1 x 800 = 800 GARBAGE DISPOSAL = 1 x 800 = 800 1 x 12000 = 12000 nA _R HEATER = 1 x 4500 = 4500 C'OT'lES WASHER = 1 x 860 = 860 CLOTHES DRYER 1 x 5000 = 5000 LAUNDRY = 1 x 1500 = + 1500 DEMAND LOAD PENTHOUSE DEMAND LOAD FIRST 10,000 W @ 100% 10000 10000 FIRST 10,000 W @ 100% = 10000 REMAINDER 21,420 W @ 40% = 8568 8568 REMAINDER 24,180 W @ 40% = 9670 COOLING LOAD & FC 3600@ 100% = 3600 3300 COOLING LOAD & FC 4000@ 100% = 4000 HEATING LOAD & FC @ 65% _ -T96B HEATING LOAD & FC. @ 65% = - + t 22168 I = 21Bg = 105.0 AMPS 23,670 22,168 23,670 1 = 106.5 AMPS 1 = 208 = 114.0 AMPS 208 NEUTRAL LOAD NEUTRAL LOAD GENERAL 3600, GENERAL 3360 SMALL APPLIANCES 3000 SMALL APPLIANCES 4500 + LAUNDRY CIRCUIT ♦ 15nn 6600 9360 3000 WATTS @ 100% 3000 3000 WATTS @ 100% 3600 WATTS @ 35% 1260 6360 WATTS @ 35% GARBAGE DISPOSAL 800 GARBAGE DISPOSAL 800 TRASH COMPACTOR 860 REFRIGERATOR 860 DISHWASHER 800 DISHWASHER 800 CLOTHES WASHER 860 CLOTHES WASHER 860 + TRASH COMPACTOR t 860 3320 x .75 2490 4180 x .75 RANGE (8,000) /x 0.7 5600 RANGE (8,000) x 0.7 DRYER 1200 t 1200 DRYER 1200 I = 13208 65.1 AMPS 13550 I 15„l70 = = 73.0 AMPS 208 FEEDER FEEDER 202 THW IN 1y „C 2#2 THW IN 1 <'"C 1N4 THW I # 4 THW APARTMENT U LOAD COMPUTATION (NEC 220-30) AREA 800 SQ. FT. GENERAL LIGHTING = 3 x 800 = 2400 W (3W/SQ.FT.xSQ.FT.) SMALL APPLIANCES 2 x 1500 = 3000 REFRIGERATOR = 1 x 860 = 860 DISHWASHER = 1 x 800 = 800 GARBAGE DISPOSAL = 1 x 800 = 800 RANGE = 1 x 12000 = 12000 WATER HEATER = i x 4500 = 4500 CLOTHES WASHER 1 x 860 860 1{ CLOTHES DRYER 1, x 5000 5000 LAUNDRY 1 x 1500 1500 + 31720 DEMAND LOAD FIRST 10',000 W @ 100% = 10000 REMAINDER 21,720 W @ 40% = 8688 COOLING LOAD & FC 3100@ 100% = 3100 HEATING LOAD & FC @ 65% _ - + 21788 21,788 I = - 208 =; 105.0 AMPS NEUTEA-L LOa GENERAL 2400 SMALL APPLIANCES' 3000 LAUNDRY CIRCUIT 1500 6900 3000 3000 WATTS @ 100% 3000 2230 3900 WATTS @ 35% 1370 GARBAGE DISPOSAL 800 REFRIGERATOR 860 DISHWASHER 800 CLOTHES WASHER 860 TRASH COMPACTOR + 860 3140 4180 x .75 3140 5600 RANGE (8,000) x 0.7 5600 * 1200 DRYER 1200 i1200 15170 14310 14310 I = 69.0 AMPS 208 FEEEEF 2#2 THW IN 1; "C 1H4 THW "..ETER BANK I LOAD COMPUTATIONS A APARTMENT 40,340 x 2 80,680 B APARTMENT` 35,020 x 3 = 105,060 C APARTMENT 37,270 x 2 = 74,540 G APARTMENT 38,180 x l = 38,180 H APARTMENT,` 36,460 X 1 = + 36,460 334,920 DEMAND FACTOR .43 (NEC 220-32) DEMAND LOAD = 334,920 x.43 = 144,020 144,020 IO = 208 x fi�]3 = 400.0 AMPS NEUTRAL LOAD 1. GENERAL LIGHTING A = 2 x 5520 = 11,040 B 3 x 3600 = 10,800 C = 2 x 43.50 = 8,700 G = 1 x 3360 = 3,360 H = 1 x 3540 = + 3,540 2. SMALL APPLIANCES 37,440 A = 2 x 6000 = 12,000 B = 3 x 3000' 9,000 C = 2 x 4500 = 9,000 G = 1 x 6000 = 6,000 H = 1 x 4500 = + 4,500 TTI= FIRST 3000W @ 100% 3000 REMAINING 74940W @ 35% + 26230 + 29230 (*) 3. FIXED APPLIANCES 7 x 3320 x 0.75 = 17430 (*) 2 x 4180 x 0.75 = 6270 4. RANGES (NEC 220-19) 9 x 2/3 = 6 UNITS DL = 21 KW 21 x 3/2 = 31,5 KW NEUTRAL 0.7 x 31,500 = 22050 (*) 5. DRYERS 9 x 2/3 =6 55%DEMAND 1200 x 9 x 55% = 5940 + 5490 ADDING (*) 80920 TOTAL WATTS IN ZUB = 80x .73 = 225.OAMPS 1 - 400 AMP-3P MAIN BREAKER W/ 42,000 AIC (INTEGRATED RATING) 9 - 125 AMP-2P (APT .A,B,C,G&H ) MAIN BREAKERS 9 - 125 AMP METER SOCKETS 400 AMP BUSWAY TAP 30-4W METER BANK II LOAD COMPUTATIONS D APARTMENT 37,270 x 2 = 75,440 E- APARTMENT 35,020 x 3 = 105,060" F APARTMENT 40,340 x 2 = 80,680: I APARTMENT 36,460 x 1 = 36,460'0 J APARTMENT 34,820 x. l = + 34,82a= 332,460,,' DEMAND FACTOR .43 (NEC 220-32) D M ,ND LOAD = 332,460 x .43 = 142,960 p Id = 14[68 x'� 73 = 397.OAMPS " NEUTRAL LOAD 1. GENERAL LIGHTING'' D = 2 .x 4350 = 8,700 r E = 3 x 3600 = 10,800 F = 2 x 5520 11,040 I = 1 x 3540 = 3,540 ` J = 1 x 2400 = + 2,400 ' 36,480 2. SMALL APPLIANCES D = 2 x 4500 = 9,000 E = 3 x 3000 = 9,000 F = 2 x 6000 = 12,000 I = 1 x 4500 = 4,500 J = 1 x 4500 = + 4,500 39,000 FIRST 3000W @ 100% 3000 REMAINING 7248OW @ 35% + 26420 2942.0 (*) 3. FIXED APPLIANCES 7 x 3320 x 0.75 17430 (*) 2 x 4180 x 0.75.-� " 6270 4. RANGES (NEC 220-19) _ 9 x 2/3 = 6 UNITS I DL'= " i 21 x 3/2 = 31'.5 KW NEUTRAL 0..7 x 31,500.' 5. DRYERS ,, 9 x 2/3 6 55% OEMAND 1200 x 9 x 55% = 5940 + _5940_ADDING -T 1110 TOTAL WATTS IN = 81��g x �0 = 225.OAMPS 1 - 400 AMP-3P MAIN BREAKER W/ 42,000 AIC (INTEGRATED RATING) 9 - 125 AMP-2P (APT.D,E,F,I& J) MAIN BREAKERS 9 - 125 AMP METER SOCKETS 400 AMP BUSWAY TAP 30-4W 11 I-V L DATA: 120/208V-3l6-4W, SQUARE D NQOB PANELBOARD, SURFACE MT'D ,CATION: CTRICAL II;`L*#A' TOWER #2 100A-MLO "IRCUIT NO, POLE CB TRIP DEMAND LOAD N0 DEMAND LOAD DESCRIPTION OF LOAD W[RE & CONDUIT N(JTLS 1,3 " 1 QOB 20 - 2400 LIGHTS #12TW-C 2 f - 1350 LIGHTS #12TW-C ON PHC 4 _ 1500 EF-6 #12TW-C 5 _ 1000 'WATER TREAT. 6,7 - 2000 T.V. EQUIPMENT 8 - 1200 SPARE - 9 - 1200 SPARE - 11 - 1000 SPARE - 10 - 800 GROUND FLOOR #12TW-C 12 i 1200 SPARE - 13,15 - 2000 SPARE - 14 { _ 1'D00 SPARE _ 1 6 ,1 8 2 On B 1 $ 0 - 34Oo OuTst9% L.Ts. wr. w !NC 17,19 2 QOB 20 006%61LLti. MNT%-%% sNtc. 20 1 - - - - SPACE - ui%o it i iT1i0 ' 44,0 AMPS FEEDER 4#4 THW-1,"C 4A4EL _'zH/208V-30-4W, SQUARE D NQOB PANELBOARD, SURFACE'MT'D AT I oN c ELECTRICAL ROOM TOWER #2 100A-MILD 'IRCUIT NO. POLE CB TRIP DEMAND LOAD NO DEMAND LOAD DESCRIPTION OF LOAD WIRE & CONDUIT NOTES 1,3 1 OB 20 - 2400 PUMP ROOM LIGHTS #12TW-C 5 80Q SPARE 2 1000 SWITCH GEAR ROOM 4 -. 1200 ELEVATOR PIT 9 1200 ELEVATOR PIT 8 600 FIRE DEPT. DOOM 11 Boo DIRECTORY BOARD 6 - 1200 DAY TANK PUMP 7 - 1000 BATTERY CHARGER 10 1200 TELEPHONE BOARD 12,14 - 2400 FIRE ALARM PANEL 2400 SECURITY EQUIPMENT 16-18 - 3600 SPARE 19-24 - - - - SPACE ` j 19800 19800 IL = - 6C 55 AMPS FEEDER 4#4THW-1;"C A^;EL DATA: 120/20$V-36-4W, SQUARED TYPE NQOB E2 OCAT10N: 4TH FL, ELECTRICAL ROOM (TOWER N0, 1 & TOWER NO, 2) 100A-MLO 1 CIRCUITS NO. ROLE CB TRIP DEMAND LOAD No DEMAND LOAD DESCRIPTION OF LOAD WIRE & CONDUIT NOTES I 1 QOS 20 - 1050 EXIT LIGHTS #12TW-C 3,5 - 1750 EMERGENCY LIGHTS 7,9 - 2300 2 - 1200 EXIT LIGHTS 4,6 - 1950 EMERGENCY LIGHTS 8 - 1000 SPARE 10 - 1200 IROOF LIGHTS 9,11 1000 TEL. EQUIPMENT 12,14 2 1 - 1830 EF-2 1 HP 15,17,19 3 40 7700 AC-#5 3#I0THW-C 13 1 20 300 OBSTRUCTION LIGHTS #12TW-C 16,18,20 1 20 3600 SPARE 21-30 - - - - - SPACE - 24880 a 25% LM 2690 27570 1L 275 0 70 = 76.0 AMPS FEEDER 4#4THW-11,"C ..ram s;A%EL DATA. 120/108V-30-4W, I LINE PANELBOARD, SURFACE MT'D EM, LOCATION: MAIN SWG'R ROOM, TOWER #2 40OA-MLO CIRCUIT NO. POLE CB TRIP DEMAND LOAD NO DEMAND LOAD DESCRIPTION OF LOAD WIRE & CONDUIT NOTES 1,3,5 3 F48 50 - 12038 HOUSE PUMPS 3#8THW-111C 2-5HP 2,4,6 3 90 - 22680 PANEL E-2 TOWER 1 4#4THW-1;"C 7,9,11 3 90 22680 PANEL E-2 TOWER 2 4#4THW-1;"C 8,10,12 3 90 - 19800 PANEL El 4#4THW-1V'C 13,15,171 1 20 - 3600 SPARE - — 14,16,18 1 20 3600 SPARE - — 1.9-24 _ _ - - SPACE - - + _ 84398 25% LM 4356 _ 2 _ 88754 1 = 88754 = 246.5 AMPS 360 FEEDER 3-350MCM _ THW 3"0 1-250MCM A P T F I X T U R E S C 11 E D U L E DES MTG LAMP TYPE VOLTS NO.OF LAMPS DESCRIPTION MANUFACTURER 3 ATALOG NO. NOTES AA S F 120 2-35W SS/CW 8STRIPS LITHONIA 8TC140 BB` S F 120 2-35W SS/CW 4' STRIPS LITHONIA C240 Cj S 1 120 - DINING ROOM LIGHT BY OWNER OD' S F 120 2-60W HALL LIGHT LIGHTOLIER 4364 EE S I 120 1-60W CLOSET LIGHT LIGHTOLIER 5701 FF R 1 120 1-1Dow FAN & LIGHT COMBINATION NUTONE 8672 GG S I 120 B-25W VANITY LIGHT - 4' LIGHTOLIER 4326 HH S I I20 6-25W VANITY LIGHT - 3' LIGHTOLIER 4324 II S I 120 1-1DOW BALCONY LIGHTS HALO H2471 KK STEM 1 120 1-1DOW BREAKFAST LIGHTOLIER 5556 LL S I 120 1-22/32W DEN LIGHTOLIER 10148 FIXTURE SCHEDULE DES MT6 LAMP TYPE VOLTS NO.OF LAMPS DESCRIPTION MANUFACTURER b ATALOG NO, NOTES A S F 120 1-22W SQUARE SURFACE MOUNTED HALO H2541 B S F 1-30W MINISTRIP LITHONIA 5130HRS C S F 1-40W MINISTRIP LITHONIA S140HRS D S F 1-40W STRIP WITH ANTENNA GUARD ACME 7351-4R-H E _ - _ _ NOT USED F S I 120 LOBBY ELEVATOR AS SELECTED BY ARC ITECT G S I 1-60W/130V CEILING MOUNT HALO H2412-AL H S F 4-35W/SS 8'STRIP WITH GUARD LITHONIA 8TC240-14 I S F 2-35W/SS 8'STRIP WITH GUARD LITHONIA 8TC240-14 K R F 3-35W/SS 2x4 LAY -IN ACRYLIC LITHONIA 2GP340-Al2 L S F 2-35W/SS 4' WRAP AROUND LITHONIA VC-240A M S F 4-35W/SS 8' WRAP AROUND LITHONIA 8TVC-240A N F 2-35W/SS 4' STRIP WITH GUARD LITHONIA C240 0 1 S I 1-100W VAPORTIGHT HALO H2410-AL I P S F' 1-22/32W CIRCULUME LIGHTOLIER 10148 Q W I 1-10OW VAPORTIGHT WALL BRACKET WITH GUARD STONCO VWXL-11GC R W HPS 1-70W PARACYL MOLDCAST 89120-12-BZ S W I 1-100W PORCELAIN LAMPHOLDER WITH PULL CHAIN LEVITON 29816-C , T S F 1-60W OPAL GLOBE LIGHTOLIER 5596 U R M 1-10OW RECESSED MULTIGROOVE LIGHTOLIER 33012-A8 V R M 1-100W RECESSED MULTIGPOOVE TH At_XF„1f1 LIGHTOLIER 33012-A8-AUX - W S M 120 1-100 MULTI -BAFFLE SURFACE LIGHTOLIER s` 32822-EB Y' P I 120 2-100421=T OBSTRUCTION LIGHTS HUBBELL pYMB- - HQ- - AP-53-R-7-AP-3 Z P HPS 120 1-70W BOLLARD -SQUARE BRONZE FINISH LIGHTOLIER NCCG-7617 Xi R I 120 2-8W-T5 RECESSED EXIT LIGHT ALKCO ERUG-I2-FL-2 X2 S I 120 2-8W-T5 SURFACE EXIT LIGHT ALKCO UG-12-FL-2 X3 S I 120 BATTERY PACK CHLORIDE CNM25-TS-2-18/3