Loading...
HomeMy WebLinkAbout07030073 FEDERAL ENGINEERING & TESTING 250 S.W. 131H AVENUE POMPANO BEACH, FLORIDA 33069 1798 AGORA CIRCLE S.E. SUITE 5 PALM BAY, FLORIDA 32909 07-1463 / / , //.1+ ¡ru FIELD DENSITY TESTS OF COMPACTED SOILS 5/24/07 ORDER NO: PERMIT NO. DATE: 07030073 CLIENT: JOHNSON CONSTRUCTION ADDRESS: 1 002 AVENUE E~ FT. PIERCE~ FLORIDA 34590 PROJECT: PROPOSED GARAGE BUILDING PAD LOT 18-19 ADDRESS: 47TH STREET, FORT PIERCE, FLORIDA MATERIAL DESCRIPTION: BROWN SILICA SAND W/SOME CLAY & TRACES OF SHELL FRAGS LOCATION: N.E. CORNER OF PAD S.W. CORNER OF PAD S.E. CORNER OF PAD LOCATION: LOCATION: LOCATION: LOCATION: LOCATION: FIELD DENSITY METHOD A.S.T.M. D-2922 DRY DENSITY P.C.F. IN THE FIELD 1 06.2 104.5 1 05.2 % MOISTURE 8.9 10.0 8.7 % CaMP ACTION IN THE FIELD 96.7 95.1 95.8 % CaMP ACTION REQUIREMENT 95% PROCTOR VALUE, P.C.F. 1 09 . 9 OPTIl\1UM MOISTURE, % 12.7 LABORATORY NO. P-II31 DEPTH IN INCHES 12 PROCTOR A.S. T.M. D-1557 METHOD REMARKS: SOIL NOT TESTED BELOW FOOTERS TESTED BY: JW CHECKED BY: KM Respectfully submitted, ''.All. 5 ~ ~rt1 /., " ~ J 7 --- ...-'WISSAM S. N~v,P.~ FEDERAl, ffi~GrNEERING & TESTING FLORIDA REG. #39584 As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts :trom or regarding our reports is reserved pending our written approval. A density test detennines the degree of compaction of the tested layer of material only. A density does not replace a soil bearing capacity detennination.