HomeMy WebLinkAbout05080181
DATE FILED: 10 1,1 :& ~ oS"
REVISION FEE: ~. OÙ
PERMIT #: 050.g· 0 I 8' I
RECEIPT #: ~~(00
ST. LUCIE COUNTY
DEPARTl\1ENT OF COMMUNITY DEVELOPMENT
BUILDING & ZONING
2300 VIRGINIA A VENUE
FORT PIERCE, FLORIDA 34982-5652
772-462-1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCA TION/SITE
ADDRESS: "550 <0 SU-h se-f
B J vd ~
2. DETAILED DESCRIPTIONS OF PROJECT
REVISIONS:- l='O{2GoT \D Äe>:o F\AT 'RooF ON ·"?ê'RJ\.Alr-¡·
3. CONTRACTOR INFORMATION:
ST. OF FL REG/CERT..!:-CC- (!D 5,73 qq ;a ST. ~UCIE COUNTY CERT #: I to 11 If
. BUSINESS NAME: 1 véLCle J1) t'f1d.5 OÙç-¡ Y'1g.
QUALIFIERS NAME: ¡UICh.ae.I·, T- .¡U.(ller- -
ADDRESS: eX? 14- 6·'x 7'1-jJ .5ï
CITY: _ 1-0121 P /£12.( c..-::: STATE ¡.c, ZIP: 3l¡q 9$
PHONE (DAYTIME): (77 ).) 4 (j & Ql.{dO FAX # c.¡ IPfp QUrY-C
4. A RCHITIENGINEER:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
STATE
FAX#
ZIP:
12/19/02
5è ~~ ~~,-,~.,
......r -..,..- ~r.-"",;;;:;.~;...~..-.u'~
BuildinSiJ
Fee Receipt
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1148
Date: 13 October 2005
Receipt #: 0000026866
Job Address: 5506 SUNSET BLVD
Permit Number: SLC- 0508-0181
Received By: serranob
Amount: $25.00
Paid With: CK
Credit Card Number:
Check Number: 268
Paid By: TRADE WINDS ROOFING
Sign:
_·ID
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
PRODUCT CONTROL NOTICE OF ACCEPTANCE
Johns Manville Corp.
717 17 Street (p.O. Box 5108)
Denver ,CO 80217
BUILDING CODE COMPLIANCE OFFICE
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 37S-2901 FAX (305) 375-2908
CONTRACTOR LICENSING SECTION
(305) 375-2527 FAX (305) 375-2558
CONTRACTOR ENFORCEMENT DMSION
(305) 375-2966 FAX (305) 375-2908
PRODUCT CONTROL DIVISION
(305) 375-2902 FAX (305) 372-6339
Y our application for Notice of Acceptance (NOA) of:
Johns Manville Modified Bitumen Roormg Systems Over Wood Deck
under Chapter 8 of the Code of Miami-Dade County governing the use of Alternate Materials and Types of
Construction, and completely described herein, has been recommended for acceptance by the Miami-Dade
County Building Code Compliance Office (HCCO) under the conditions specified herein.
This NOA shall not be valid afte e stated below. acco reserves the right to secure this
product or material at any time lant for quality control testing. If this
product or material fails to ped CO may revoke, modify, or suspend the
use of such product or materi imm e rve the right to revoke this approval, if it is
determined by acco that this product or material fails to meet the requirements of the South Florida
Building Code.
ACCEPTANCE NO.: 01-0206.17
EXPURES: O~14n006
The expense of such testing will be incurred by the manufacturer.
Raul Rodriguez
Chief Product Control Division
TIllS IS THE COVERSBEET.. SEE ADDmONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS
BUILDING CODE & PRODUCT REVIEW COMMITTEE
This application for Product Approval has been reviewed by the BCCO and approved by' the Building
Code and Product Review Committee to be used in Miami-Dade County, Florida under the conditions set
forth above.
-¡~
APPROVED: 06/1412001
Francisco J. Quintana, R.A.
Director
Miami-Dade County
Building Code Compliance Office
\\5045000 I \pc2000\\Ĺ“mplates\nodc8 acceptance cover page.dot
Internet mail address: postmaster@buildingcodeonline.com . Homepage: http://www.buildingcodeonline.com
JOHNS MANVILLE CORPORATION
Acceptance No.: 01-0206.17
ROOFING ASSEMBLY APPROVAL
Cateszorv:
Sub-Cateszorv:
Roofmg
APP Modified Bitumen
Approval Date: June 14. 2001
Expiration Date: June 14. 2006
Deck TVDe:
Maximum Desio Pressure
Fire Classification:
Wood
-52.5 psf
See General Limitation # 1
TRADE NAMES OF PRODUCTS MANuFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Soecification Descriotion
1M APP Base 150 sq. ft. roll ASTM D 5147 APP modified asphalt, fiberglass reinforced,
smooth surfaced base sheet.
APPeX 48 32.8' x 3.28'; 90 lb. ASTM D 6222, APP modified asphalt, polyester reinforced,
roll type I, grade S smooth surfaced membrane.
/.:::ex 4.5M 32.8' x 3.28'; 90 lb. ASTM D 6222, APP modified asphalt, polyester reinforced,
roll type I grade G mineral surfaced membrane.
APPeX 4.5MFR 32.8' x 3.28'; 90 lb. ASTM D 6222, APP modified asphalt, polyester reinforced,
roll type I grade G fire-retardant,· mineral surfaced membrane.
APPeX 180 32.8' x 3.28'; 90 lb. ASTM D 6222, APP modified asphalt, polyester reinforced,
roll type I, grade G smooth surfaced membrane.
Bicor MFR 39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester I glass
reinforced, granule surfaced membrane.
Tricor MFR 39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass
reinforced, granule swfaced membrane.
Bicor S 39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass
reinforced, smooth surfaced membrane.
Tricor S 39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass
reinforced, smooth surfaced membrane.
Glasply Premier 36" x 180' ASTM D 2178 Type VI asphalt impregnated glass felt for use
Type VI in conventionw and modified bitumen built-up
roofing.
Glasply IV 36" x 200' ASTM D 4601 Type IV asphalt impregnated glass felt for use
Type IV in conventional and modified bitumen built-up
roofing.
2
Frank ZuIoaga, RRC
Roofing Product Control Examiner
JOHNS MANVILLE CORPORATION Acceptance No.: 01-0206.17
Test Product
Dimensions Specification Des eriotion
36" x 108'; roll ASTM D 4601 Type II asphalt impregnated and coated glass
weight: 84 Ibs. fiber base sheet for use in conventional and
modified bitumen built-up roofing.
permaPly 28 36' x 108'; ASTM D 4601 Type n asphalt impregnated and coated glass
72 lb. roll fiber base sheet
Ventsulation 36" x 36' ASTM D 4897 Heavy duty fiber glass base sheet impregnated
Type II and coated on both sides with asphalt with or
without fine mineral stabilizer.
JM Ultrafast various PA 114 Insulation fastener assembly (steel decks
only).
JM CD-lO Various PA 114 Insulation fastener for concrete decks.
JM ISO-lor various ASTM C 1289 Rigid polyisocyanurate roof insulation for use
Tapered ISO-1 in conventional built-up and other roof
systems; available flat or tapered.
JM Fesco or Tapered Fesco various ASTM C 728 Rigid perlite roof insUlation board for built-up
rooting systemS; available flat or tapered.
JM 112" Retrofit various ASTM C 728 A high density perlite roof insulation board for
use in conventional and modified bitumen
built-up rooting systems.
E"NRG"Y -2 or Tapered various ASTM C 1289 Polyisocyanurate insulation for use with
E'NRG'Y -2 single-ply, BUR and modified bitumen roof
covers (includes all Factory Mutual approved
roof covers)
1M Fesco Foam various ASTM C 1289 Rigid polyisocyanurate roof insulation with
perlite board facing bonded to one side for use
in conventional built-up and other roofing.
1M Fiberglas Roof various PA 110 Fiber glass roof insulation
Insulation
1M Topgard Type B ASTM D 1227 Fire rated, fibered, non-asbestos, clay water
base asphalt emulsion.
1M Fibrated Aluminum ASTM D 2824 Fire rated, fibered, non-asbestos aluminum
Roof Coating coating.
1M Premium Fibered ASTM D 2824 Fire rated, flbered, non-asbestos asphalt
Aluminum Roof Coating aluminum COB ·
3
Frank Zuloaga, RRC
Roofing Product Control Examiner
JOHNS MANVILLE CORPORATION Acceptance No.: 01-0206.17
Test Product
Dimensions SDecification DeseriotiOD
36" x 108'; roll ASTM D 4601 Type II asphalt impregnated and coated glass
weight: 84 Ibs. fiber base sheet for use in conventional and
modified bitumen built-up rooting.
PermaPly 28 36' x 108'; ASTM D 4601 Type IT asphalt impregnated and coated glass
72 lb. roll fiber base sheet
VentsuIation 36" x 36' ASTM D 4897 Heavy duty fiber glass base sheet impregnated
Type II and coated on both sides with asphalt with or
without fme mineral stabilizer.
1M Ultrafast various PA 114 Insulation fastener assembly (steel decks
only).
1M CD-IO VarioDs PA 114 Insulation fastener for concrete decks.
1M ISO-lor various ASTM C 1289 Rigid polyisocyanurate roof insulation for use
Tapered ISO- I in conventional built-up and other roof
systems; available flat or tapered.
1M Fesco or Tapered Fesco various ASTM C 728 Rigid perlite roof insulation board for built-up
roofing systems; available flat or tapered.
1M 1/2" Retrofit various ASTM C 728 A high density perlite roof insulation board for
use in conventional and modified bitumen
built-up roofing systems.
E"NRG"Y-2 or Tapered various ASTM C 1289 Polyisocyanurate insulation for use with
E'NRG'Y-2 single-ply, BUR and modified bitumen roof
covers (includes all Factory Mutual approved
roof covers)
1M Fesco Foam various ASTM C 1289 Rigid polyisocyanurate roof insulation with
perlite board facing bonded to one side for use
in conventional built-up and other roofing.
1M Fiberglas Roof various PA 110 Fiber glass roof insulation
Insulation
1M Topgard Type B ASTM D 1227 Fire rated, fibered, non-asbestos, clay water
base asphalt emulsion.
1M Fibrated Aluminum ASTM D 2824 Fire rated, fibered, non-asbestos aluminum
Roof Coating coating.
1M Premium Fibered ASTM D 2824 Fire rated, flbered, non-asbestos asphalt
Aluminum Roof Coating aluminum coa
3
Frank Zuloaga, RRe
Roofing Product Control Examiner
JOHNS MANVILLE CORPORATION
Acceptance No.: 01-0206.17
Deck Type 1: Wood, Non-insulated
Deck Description: 19/32" or greater plywood or wood plank decks
System Type E: Base sheet mechanically fastened.
Base Sheet:
All General and System Limitations apply.
Ply Sheet:
Membrane:
Surfacing:
(Option #1) One ply of 1M APP Base, 1M PermaPly 28, JM Glasbase, JM
Glasbase Plus or 1M VentsuIation mechanically fastened to the deck with 1M
Ultrafast, Olympic or Tru-Fast metal plates and fasteners at a 4" side lap 12" o.c.
and two rows staggered in the center of the sheet 18" o.c.
Maximum Design,Pressure -4S pst - See Géneral Limitation #9.
(Option #2) Minimum two plies of 1M PermaPly 28 or JM Ventsulation
simultaneously fastened to the deck with JM Ultrafast fasteners and Square Metal
Plates spaced 9" o.c. in a 4" lap and 12" o.C. in two staggered rows in the center of
the sheet.
Maximum Design Pressure -52.5 pst - See General Limitation #7.
(Optional) One or more plies of 1M APP Base, APPeX 48 or APPeX 180 heat
welded to base sheet.
One or two plies of APPeX 48, APPeX 180, APPeX 4.5M or APPeX 4.5 MFR
heat welded.
(Optional) Install one of the following for all systems that do not achieve
acceptable fire ratings through the use of FR membrane sheets.
1. 400 IbJsq. gravel or 300 lb.lsq. slag in a flood coat of approved mopping
asphalt at a rate of 60 lb.lsq.
2. Karnak 97, Kamak 97 AF, Monsey Premium Long Life Aluminum Roof
Coating Asbestos Free or Monsey Prograde Aluminum, 1M Topgard Type A,
Topgard Type B, 1M Aluminum RF CT, Grundy AL MB aluminum coating at
a rate of 1-1/2 gaI/sq Monsey Aquabrite, Gardner asphalt emulsion, APOC
8unbright 400 or Henry 229 Aluminum Emulsion at 2~ gaI/sq or APOC 212
Aluminum Roof Coating at 3 gal/sq.
3. Gnmdy 20 F asphalt emulsion, Endure Asphalt Emulsion, APQC 302 or 302
AF applied at 2~ gal/sq with optiona160 lbs.lsq. of roofing granules
embedded in wet coating.
15
Frank Zuloaga, RRC
Roofing Product Control Examiner
JOHNS MANVILLE CORPORATION
Acceptance No.: 01-0206.17
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor
sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The fIrst layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of20-40 Ibs.lsq., or mechanical1y
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 12 Ibs.lsq. Note: Spot attached systems shall be limited to a maximum
design pressure of -45 psf.
5. Fastener spåcing for insulation attachment is based on a Minimum Characteristic Force (P') value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested, are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchorlbase sheet or membrane attachment is based
on a minimum fastener resistance value in co~unction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered
Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. (When this limitation is specifically
referred within this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform with Roofmg Application Standard RAS 111 and applicable wind load requirements.
9 · The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and comers). Neither rational analysis, nor extrapolation shaH be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
16
Frank Zuloaga, RRC
Rooting Product Control Examiner
JOHNS MANVILLE CORPORATION
Acceptance No.: 01-0206.17
NOTICE OF ACCEPTANCE STANDARD CONDITIONS
Renewal of this Acceptance (approval) shall be considered after a renewal application has been
filed and the original submitted documentation, including test supporting data, engineering
documents, are no older than eight (8) years.
2 Any and all approved products shall be permanently labeled with the manufacture~s name, city,
state, and the following statement: "Miami-Dade County Product Control Approved", or as
specifically stated in the specific conditions of this Acceptance.
3 Renewals of Acceptance will not be considered if:
a) There has been a change in the South Florida Building Code affecting the evaluation of this
product and the product is not in compliance with the code changes;
b) The product is no longer the same product (identical) as the one originally approved;
c) If the Acceptance holder has not complied with all the requirements of this acceptance,
including the correct installation of the product;
d) The engineer who originally prepared, signed and sealed the required documentation initially
submitted, is no longer practicing the engineering profession.
4 Any revision or change in the materials, use, and/or manufacture of the product or process shall
automatically be cause for termination of this Acceptance, unless prior written approval has been
requested (through the filing of a revision application with appropriate fee) and granted by this
office.
5 Any of the following shall also be grounds for removal of this Acceptance:
a) Unsatisfactory performance of this product or process;
b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any
other purposes.
6 The Notice of Acceptance number preceded by the words Miami-Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the
Notice of Acceptance is displayed, then it shall be done in its entirety.
7 A copy of this Acceptance as well as approved drawings 3lid other documents, where it applies,
shall be provided to the user by the manufacturer or its distributors and shall be available for
inspection at the job site at all times. The copies need not be resealed by the engineer.
8 Failure to comply with any section of this Acceptance shall be cause for termination and removal
of Acceptance.
9 This Acceptance contains pages 1 through 17.
END OF THIS ACCEPTANCE
17
Frank Zuloaga, RRC
Roofing Product Control Examiner
J¡~
Johns Manville
Two Ply Heat Welded Modified Bitumen Mineral Surfaced
Roofing System. For use over plywood or other nailable
decks on inclines up to 6" per foot (500 mm/m).
for Regions 1, 2 and 3
Materials per 100 sq. ft. (9.3 In2) of Roof Area
Sheathing Paper:
'Nood board decks only
Base Ply:
TRICOR S*, BICOR S*, APPeX 4S, APPeX 180,
JM APP Base, GlasBase or PermaPly 28
Cap: .
2CNN-W- TRICOR M FR* or BIGOR M FR
2PNN-W-APPeX 4.5M FR or APPeX 4.5M
Approximate installed weight: 115 - 175 Ibs. (52 - 79 kgs.)
1 layer
1 layer
1 layer
General
This specification is for use over any type of approved structural deck
(without insulation) which can receive and adequately retain nails or
other mechanical fasteners that (nay be recorllmended by the deck manu-
facturer. Exalnples of these decks are wood, plywood, and approved ori-
ented strand board (OSS). This specification is not for use over light-
'Neight insulating concrete decks.
Design and installation of the deck and/or roof substrate must result in
the roof draining freely, to outlets numerous enough and so located as
to remove water promptly and completely. Areas where water ponds
for more than 24 hours are unacceptable and will not be eligible for a
JM Roofing System Guarantee.
flashings
Flashiny details can be found in the UBituminous Flashings" section of the
J M Cornmercial/lndustrial Rooting ~ystems Manual.
Appl ¡cation
Using one of the base plies listed, start with a piece 193f4" (502 mm) wide.
The remaining plies are to be applied full width 311 (76 mm) side and 411
(102 mnl) end laps over the preceding sheets. Nail the laps at 9" (229 mm)
centers, and down the longitudinal center of each felt ply, place two rows
of fasteners, with the rows spaced approximately 11" (279 mm) apart, and
fasteners staggered on approximately 1811 (457 mm) centers. Use nails or
tasteners appropriate to the type of deck, with 1" (25 mm) minimum diame-
ter caps. For additional fastener information, refer to the fastener data in
the "Roof Decks" section of the current JM Commercial/Industrial Roofing
Systems Manual.
Specification 2CNN-W/2PNN-W
Q)
0)
(0
c:
'ëõ
ð
Nailable Deck
TRICOR 5, BICOR S, APPeX 45,
APPeX 180, JM APP Base, --.1
GlasBase or PermaPly 28 I
Sheathing Paper
(If Required)
. . .
. -..
. .
. . ". .
, ' . · . Approved JM
. '.. APP Cap Sheet .
. .- . .
. . - .
~
. ~. .
Heat-Weld
I~I Bitumen
. . .
. .
2CNN-W/2PNN-W
Heat weld a full width piece of one of the cap sheets listed so that it is
firmly and uniformly set. Subsequent sheets are to be applied in the same
manner, with 4" (102 mm) side and 6" (152 mm) end laps over the preced-
ing sheets. All laps must be rolled with a 31' (76 mm) rounded edge roller.
A 1Æ" to ~II (3 mm to 10 mm) bleedout of APP compound shall be visible at
the edge of all seams. All laps must be checked for good adhesion.
Preparation of the 611 (152 mm) end lap requires scuffing away all loose
granules. Heat and embed all remaining granules. Apply heat to the roll
being seamed while making sure both have a good compound flow to
adhere the two surfaces. End laps must be checked for proper adhesion.
Application of JM APP Modified Bitumen Products may require the use
of an open fla~e propane torch. Improper use of these materials and
application equipment can result in severe burns, and/or other physical
injury, as well as damage to property. In order to prevent these situa-
tions the mechanic must install the materials using the techniques rec-
ommended by JM and those found in "A Guide to Safety: Torch-On
Modified Bitumens" available from the Asphalt Roofing Manufacturers
Association. These techniques have been endorsed by the National
Roofing Contractors Association and the United Union of Roofers,
Waterproofers and Allied Workers.
For cold weather application techniques, refer to Paragraph 8A.14.
Steep Slope Requirements
Special procedures are required on inclines over 2~1t per foot
(208 mm/m). Refer to Paragraph 8A.12.
Surfacing
No additional surfacing is required.
Note: When using metric and English sized sheets in the same system,
care must be taken to avoid lap over lap configurations.
*This is a special order product. Contact your JM Sales Representative
about availability and lead time.
For an identical copy of this specification, ask for RS..4355.
A-74
JUN-19-2007 03:09P FROM:DE&T .
. 06/~8/2007 11:37 FAX 7724892661
561-253-0789
KUNWA~~ ~J)
TO: 7724626443
-+ U' 01.&Dl:øA \:I~I\
P.2
~ v,,~
[)I:£ T D'UNKELBERGER ENGINEERING & TESTING, INC.
REPORT OF ELECTRICAL INSPECTION
JOB NAME:
JOB ADDRESS:
CLIENT.
CONTRACTOR:
ENGINEER:
ARCHITECT:
DATE;
SHEET:
PROJECT NO.:
BUILDING NO.:
PEI\MIT NO..:
SUMMARY OF INSPECTIONS/ST A TUS OF WORK
I J T~ml)urary PO\\'tr Inspettion I ] Elttlrical Servie~
I) Underground Inspection f I Trbu-out Jnspeetion
( 1./Slab Jnlp~ti()n (I Other (use orea bètow)
I fÁ Rough-In Inlpection 2"?>~ I) Final Jasped'on
I J Initial IDsp~.ioQ ( ~rti.1 JnspeetioD I . Work in Progress
] Rciftspectloll
Jz I' ,luf-
IV~~
G/~~t¡ ~u~~ Q~·~S,,~tyl~ t~
RESl~TS ----·INJEC"fl0~ -
~. ß~~
e«lk,"~~..
..CORRESPO~DENCE RECEIVED FROM CONTRACTOR f7:
Ii, ¥Ie..
. " , .
DEFICIENCIES OBSERVED:
r/NO
J YES (See Above)
o Rejected
ß¡jl
Michael J. O'Connttr, P.E.
Executive Vice President
Florida Reelstration No. 44082
Speci.IIDspe~tor No. 981
Standard In8p~ctor
BN#: l3 t 6
cc: Contractor (Site)
1225 Omar Road, West Palm Beach, Florida 33405
PJ,one: (56J) 689·4299. Fax: (561) 689-5955
..o),n70. r'C:Clr;cnJ
JUN-19-2007 03:09P FROM:DE&T
561-253-0789
TO: 7724626443
P.1
Ðl:s T
West Palm Beach
Voice
(561) 689-4299
Facsimile
(561) 689-5955
E-mail:
info@detwpb.org
;,'i.:.~:,.6 ,.~~.~~:,~:: .~. ,;:;',..~ :f: ;ô; .::;;',...:.' ;,~'4..:..L: :J';;S;::::;;:ø/~
Geotechnical
Materials Testing
Inspection
Environmental
DUNKELBERGER ENGINEERING & TESTING, INC.
Facsimile Cover Sheet
To: Mr. Ken Arnold
Inspections Supervisor Fax No. 772-462-6443
Company: St. Lucie County
Code Compliance Division Project No. 05-23-5664
From: Rita Gorman Date: 6/19/07
r::;ø:.~;:gr/l/&::~:ø ~J::I J:W/Z;::.:!::;Æ-S;; :9~.¿g: z: s:-;!;;:g;.:ø:::x S:4'D/I/I/ß.;&;;Jì;Zf4:Z:: ~:r;;4::J:I/S·R:g:8.·9/.Ø(~~;S;S:~;;P;~1G::.t:::U/¿¡;~;O: ;gy';:::;:~'&G:':'!{: :s:c: .~':' :ß'''~..,:~' .:!;.' '7' ~ ,...
Total number of pages, including cover sheet: (2)
Message:
Dear Mr. Arnold:
Please find attached inspection results for electric rough (238) for
Runways End Phase I (0510-0102).
If you have any questions or comments regarding the attached
inspections, please call me at (561) 689-4299, ext. 210.
Thank you,
Rita Gorman
Hard Copy
o Will Follow Via
D u.s. Mail
DDHL
D Hand Delivery
D Will Not Follow
If you did not receive the entire fax or if you have any questions, please do not
hesitate to contact us at (561) 689-4299.
Port St. Lucie
52.'M Northwest Enterprise Drive
Port St. Lucie. Florida 34986
Phone: (772) 343-9787
Fax.: (772) 343-9404
Sarasota
8260 Vieo Court, Unit B
Sarasota, Florida 34240
Phone: (941) 379-0621
Fax: (941) 379-5061
West Palm Beach
1225 Omar Road
West Palm Beach, FlDrida 33405
Phone: (561) 689-4299
Fax: (561) 689-5955
DET 02A
1)1:8 T
DUNKELBERGER ENGINEERING & TESTING, INC.
Trimcraft
1335 Neptune Drive
Boynton Beach, Florida 33426
June 5, 2007
Project No. 05-23-5665
Inspection Report No. 16
Attention: Mr. Robert R. Kipp, Jr.
Subject: Private Provider Inspection Services
Runways End - Building 2
WindowlDoor (148)
Fort Pierce, Florida
Permit No. 0512-0569
Dear Mr. Kipp:
As requested, Dunkelberger Engineering & Testing, Inc. (DEBT) is performing Private Provider
Inspection Services in accordance with Florida Statue (F.S.) 553.791 at the subject project.
Attached is a copy of our daily inspection report summarizing the results of our inspection
performed on May 31, 2007. As reported in the field at the time of our inspection or
reinspection, the elements observed during this period have been constructed in accordance with
the project plans and specifications.
_000_
DEBT appreciates the opportunity to provide our services on this project. If we can answer any
questions, please contact us at (561) 689-4299.
Very truly yours,
DUNKELBERGER ENGINEERING & TESTING, INC.
onnor, P.E.
cutive Vice President
egistration No. 44082
Christopher S. Throop
Inspection Services Manager
FL License No. BN4338
5665 IR16:rrg
cc: St. Lucie Building Department
Attn.: Mr. Dennis Grimm, Building Official
1225 Omar Road, West Palm Beach, Florida 33405 . Phone (561) 689-4299 . Fax (561) 689-5955
,,~1·
,
Ul:e , DUNKELBERGER EN9INEF~ING & TESTING, INC.
REPORT OF FRAMING, WINDOW AND
SHEATHING INSPECTION
JOB NA"ME:
JOB ADDRESS:
CLIENT:
CONTRACTOR:
ENGINEER:
.4. RCHITECT:
,,'
DA TE:
SHEET:
PROJECT NO.:
BUILDING NO.:
PERMIT NO.:
SUMMARY OF INSPECTIONS/STATUS OF WORK
, 1 Framing
I J Sheating
I J FiJ-e Walls
r 1 hj~e Penetrations
I vr Windows .
I 1 Exterior Doors
Othe r:
I 1 Initial Inspection
l J Pa.·tis) Inspection
1 Work in PI·ogress
I 1 Reinspection
LOCATION
RESULTS OF INSPECTION ÞI!-SS-'
,
=
CORRESPONDENCE RECEIVED FROM CONTRACTOR
~
DEFiCIENCIES OBSERVED:
I
/
[0NO
r 1 YES (See Above)
o Rej eeted
cc: Contractor (Site)
1225 On1a1" Road, West Palm Beach, orida 33405
Phone: (561) 689-4299 . Fax: (561) 689-5955
.1)ET70. Tn'~~