Loading...
HomeMy WebLinkAboutBuilding Permit ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED zao 3--0 Date:,• ( Permit Number: ��16�n A Building Permit Applicatioa�, Planning and Development Services � Building and Code Regulation Division 2300 Virginia Avenue,Fort Pierce FL 34982 Phone: (772)462-1553 Fax: (772)462-1578 Commercial X Residential PERMIT APPLICATION FOR: Shutter P.ROPQSED�IMPROVEMENT"LOCATION , Address: 4250 N HIGHWAY A1A 902 Legal Description: OCEAN HARBOR SOUTH BLDG A UNIT 902 AND UND INTEREST IN COMMON ELEMENTS Property Tax ID#: 1423-501-0066-000-0 Lot No. Site Plan Name: Block No. Project Name: Nobre Setbacks Front Back: X Right Side: Left Side: DETAILED DESCRIPTION,Of WORK Install 1 accordion & 1 roll shutter CONSTRUCTION INFORMATION Additional work to ❑_ e e orme under this permit-check h a Vappy: HVAC � Gas Tank ❑Gas Piping Shutters ❑Windows/�Do ors Electric ❑ Plumbing Sprinklers M Generator Roof Roof pitch Total Sq. Ft of Construction: S Ft. of First Floor: Cost of Construction:$ 3,674.00 Utilities,-.In Septic Building Height: OWNER/LESSEE CONTRACTOR Name Ramiro J Nobre Name: Michael Heissenberg Address:4250 N Highway Al Apt 902 Company: Expert Shutter Services City: Fort Pierce State:FL Address: 668 SW Whitmore Dr Zip Code: 34949 Fax: City: Port Saint Lucie State:FL Phone No.860-995-9089 Zip Code: 34984 Fax: 772-871-0990 E-Mail: Phone No. 772-871-1915 Fill in fee simple Title Holder on next page(if different E-Mail: Callexpert@aol.com from the Owner listed above) State or County License: 16572 If value of construction is$2500 or more,a RECORDED Notice of Commencement is required. SUPPLEMENTAL CO`NSTRtJCTION LIEN LA1N INFORMATION ..., r.,_ DESIGNER/ENGINEER: Not Applicable MORTGAGE COMPANY: X Not Applicable Name: Tittecolnc. Name: Address:6355 NW 36th St Suite 305 Address: City: Virginia Gardens State: FL City: State: Zip: 33166 Phone: Zip: Phone: FEE SIMPLE TITLE HOLDER: X Not Applicable BONDING COMPANY: _Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will,in all respects, perform the work in accordance with the approved plans,the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review:room additions, accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an att ey before commencing work prrfcof-oing 'ur Notice of Commence OKI- s Signature of Owner/Lessee/Contractor as Ag nt for Owner Signature of Contractor/License Holder STATE OF FLORIDA STATE OF FLORIDA COUNTY OF St.Lucie COUNTY OF St.Lucie The forgoiinginstruP2.Pqt was acknowledge efore me The forgoing instru nt was acknowledged before me this day of 20by this r ( day of 200 by Michael Heissenb&g Michael Heissenberg (Name of person acknowledging) (Name of person acknowledging) &Y &wA_ o` ft�m (Signature of Notary Public-State of Florida) (Signature of Notary Public-State o 'Florida) Personally Known x OR Produced Identification Personally Known x OR Produced Identification Type of Identification Produced Type of Identification Produced AR Shanon O'Shea til Y (�Sh on O'Shea Commission No. GG258036 ,4I� Commission No. GGz5so3s �a ,���� aer OTARY PUBLIC ARY PUBLIC c% STATE OF FLORID STATE OF FLORIDA GOMM#GG25803 uOmm GG258038 Revised 07/15/2014 OTNCF Expires 9/12/2022 s�NQ110� ' Expires 9/12/2022 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPOWNTS A CLADDING (&S- BASIC P SBASIC WIND SPEED = 170 mph-RISK CATEGORY l/ BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, RF *q,? Fo o 01 �i D � p dass l°p ?rn PEAK L" LESS THAN 7'-9" L GREATER OR EQUAL THAN 7'-9" AND L,_ bDh eft ROOF LESS THAN 12'-3n HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE. A.S.D. ULTI 0' - 15' 76.4 45.8 102.4 61.4 73.0 43.8 95.5 57.3 68 > 15'-20' 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72 > 20'-25' 83.6 50.2 -111.9 67.1 79.8 47.9 104.4 62.6 74 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 77 > 30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113 3 68.0 81 > 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84 > 50'-60' 97.3 58.4 130.3 78.2 1 92.9 55.7 121.5 72.9 87 BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS A CLADDING (6SF.)F.) FOR BASIC WIND SPEED = 170 mph RISK CATEGORY I/ BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, Wl PEAK L- LESS THAN 12-3" LY' GREATER OR EQUAL It. ROOF HEIGHT POSITIVE NEGATIVE POSITIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIM > 60' - 70' 91.5 54.9 167.7 100.6 84.3 50.6 141 > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 15 > 80' - 90' 95.6 57.4 175.2 105.1 88.0 52.8 151 REVIEWED 0R > 90' - 100' 97.3 58.4 178.4 107.4 89.7 53.8 15; �a A > 160'.-7120' 100.5 60.3 ' 184.2 110.5-" 92.5 55.5 16, CODE COPLIA ' NCY >izo' - 140' 103.2 61.9 189.2 1135 95.1 57.1 16; T4 L CIE COUNTY > 140' - 160' 105.6 63 4 193.6 - 116.2 97.3 58.4 171 > 16o' - 180' 107.8 64.7 1976 118.6 99.3 59.6 174 BOCC > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 176 > 200' - 250' 114.1 68.5 209.2 125.5 105.2 63.1 185 > 250' - 300' 1178 70.1. 216.0 129.6 108.5 65.1 191 > 300' - 350' 121.0 72.6 221.9 133.1 111.5 66.9 196 > 350' - 400' 123.9 74.3 227.1 136.3 114.1 68.5 20C > 400' - 450' 126.4 75.8 231.8 139.1 116.5 69.9 205 > 450' - 500'1 128.8 1 773 I 236.1 141.7 118.6 71.2 208 File C®I) NOTES: I.) THIS CER7IFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES, 1S COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMAT70N FOR A SITE SPECIFIC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED 8Y THIS ENGINEER IF USED TO OBTAIN A ONE 77ME BUILDING PERMIT: 3.) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELEC77ON OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART KIND PRESSURES ARE UL7j'M47F AND A.S.D. PRESSURES 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREP. THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET- OPENING SCHEDULE/TAKE OFF SHEET, ETC.). 10 - PEAK ROOF HEIGHT LESS THAN OR EQUAL TO 60 FEET =SALE) 47ER OR EQUAL THAN 12'-3" VE NEGATIVE A.S.D. ULTIMATE A.S.D. 41 1INDICATED DESIGN WIND PRESSURES 86.4 51.8 CORRESPOND TO THE MAXIMUM END 43 2 ZONE AND INTERIOR ZONE CONDITIONS 90.8 54.5 AND FOR ALL ROOF -44-994.4 94.4 56.6 46.4 97.4 58.4 * L = STORM PANEL ACCORDION SHUTTER 7 102.4 61.4 BLADE LENGTH OR BAHAMA SHUTTER HE7GHT. � 50.6 106.5 63.9 _ 52.3 109.9 65.9 M/AMIUDADE COUNTY OR A STATE OF FLORIDA APPROVAL 7-10 - PEAK ROOF•HEIGHT GAM TER THAN 60 FEET aK ILE) Of E A.S.D. 89.0 BUILDING SCHEMATIC 91.1 93.0 94.7 97.8 100.4 102.8 ��eg°'•���A..rrt<j`eom� 106.9 111:1 No.4416 ' 114.7liza 8 so 8 ° 120.5 s a STATED o 123.1 0��®�•'°•��®A�® °° ��� �� 125.3 ®� �'' °•°.,°°. �� - .. . 2017 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RIVER COUNTIES ASCE 7-10 / WIND PRESSURE CHART L.C. STORM PANELS, ACCORDION-& BAHAMA SHUTTERS *** DRAWN BY RISK CAT. II BLDGS 08/09/17 Z����� WIND PRESSURE CHART DA IF TILLIT TESTING & ENGINEERING COMPANY BASIC WIND SPEED = 170 mph 17_.194 Y 6355 N-W- 36th. St Ste.a05, WRGiNN cwDaa R.33166 EXPOSURE D, Kd = 0.85 Phone: (305)871-1530.F-:(3Q5)871-1531 DRAWING No EB-0006719 REK N° DESfR1Pl10N DAff I REV.R. DL46B0•DDN DAZE WALTER A. TILUT 1r. P.E. 1 I DID 15-188 JEA.91171 3 FLORIDA Llc. 1/ 44167 2 1 1 1 SHEET 1 OF 1