June 12, 2007
S1. Lucie Building Department
2300 Virginia Ave.
Fort Pierce, FL 34982
This letter in regards to the following permitted jobs for South Florida Aluminum
Products:
Permit # 0704-0558:
Project: 70-29
3617 Red· Tailed Hawk Dr.
Port S1. Lucie, FL
Permit # 0704-0554
Project: 70-31
3609 Red-Tailed Hawk Dr.
Port S1. Lucie, FL
After careful review and analysis of these jobs the following changes will be made:
1) In lieu of the "U" strap, top and bottom on the sidewall that has a 209 lb. uplift rating; we
will allow the use of the Simpson 2.5 Hunicane Clip, top and bottom with 475lb uplift
rating.
2) 3/8" wedge bolts on 32" centers, also meets the uplift rating.
3) We will allow a single 2"x 4" top plate for walls up to 16' in length.
4) After doing the calculations, we find that using (3) #14 x I" S.M.S. on each side of a 3" x
3" post (6 total) to the "U-Clip" or insert, meets or exceeds the uplift required.
The future engineering sheet for South Florida Aluminum Products will have these details
on them.
Please call if you have any questions.
Thank You,
Mike Edgerly, P.E.
Skyline Engin~
3048 Industrial 33 S 1.
Ft. Pierce, FL 34946