Loading...
HomeMy WebLinkAbout07040554 P.E. No. 65276 - Audit No. 0507-029661 304i'industriã'33nrSi::";'" Ft. Pierce, FL 34946""""""';' """PhOne'(772)"429:'iooo""""';""Fãx'(772)'46S:5442 June 12, 2007 St. Lucie Building Department 2300 Virginia Ave. Fort Pierce, FL 34982 This letter in regards to the following permitted jobs for South Florida Aluminum Products: Permit # 0704-0558: Project: 70-29 3617 Red-Tailed Hawk Dr. Port St. Lucie, FL Permit # 0704-0554 Project: 70-31 3609 Red-Tailed Hawk Dr. Port St. Lucie, FL RECEIVED JUN 2 5 2007 PUblic Works St. Lucie County, FL EY After careful review and analysis of these jobs the following changes will be made: 1) In lieu of the "U" strap, top and bottom on the sidewall that has a 209 lb. uplift rating; we will allow the use of the Simpson 2.5 Hurricane Clip, top and bottom with 475lb uplift rating. 2) 3/8" wedge bolts on 32" centers, also meets the uplift rating. 3) We will allow a single 2"x 4" top plate for walls up to 16' in length. 4) After doing the calculations, we find that using (3) #14 xl" S.M.S. on each side of a 3" x 3" post (6 total) to the "u -Clip" or insert, meets or exceeds the uplift required. The future engineering sheet for South Florida Aluminum Products will have these details on them. Please call if you have any questions. Thank You, Mike Edgerly, P .E. Skyline Engine~ 3048 Industrial 33 S t. Ft. Pierce, FL 34946 (772) 465-5441 ~ JUN 1 3 2001